Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Functionally Graded”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Functional and anatomical characteristics of the nerve-brown adipose interaction in the rat

Experiments were conducted on 12 male rats to study the coupling of signals from the sympathetic nervous system to the brown adipose tissue. Analysis of electron photomicrographs revealed considerable morphological heterogeneity among the nerves entering and leaving the interscapular fat pad. In response to electrical simulation of the nerves, the temperature of the brown fat increased following a rapid but transient temperature drop. Such changes were observed only on the ipsilateral side, indicating that the innervation to the interscapular brown fat of the rat is functionally bilateral rather than diffuse. The finding that brown fat is capable of responding in a graded fashion correlates well with observations suggesting that clusters of brown adipocytes may be electrically coupled.

Flaim, K. E.↗

Parametric performance of circumferentially grooved heat pipes with homogeneous and graded-porosity slab wicks at cryogenic temperatures

A recently developed, potentially high-performance nonarterial wick has been extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 K and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: (1) maximum heat pipe performance as a function of fluid inventory, (2) maximum performance as a function of operating temperature, (3) maximum performance as a function of evaporator elevation, and (4) influence of slab wick orientation on performance. The experimental data was compared with theoretical predictions obtained with the computer program GRADE.

Groll, M.↗

Changes in Global Function and Regional Ventilation and Perfusion on SPECT During the Course of Radiotherapy in Patients With Non-Small-Cell Lung Cancer

Purpose: This study aimed to (1) examine changes in dyspnea, global pulmonary function test (PFT) results, and functional activity on ventilation (V)/perfusion (Q) single-photon emission computerized tomography (SPECT) scans during the course of radiation (RT), and (2) factors associated with the changes in patients with non-small-cell lung cancer (NSCLC). Methods and Materials: Fifty-six stage I to III NSCLC patients treated with definitive RT with or without chemotherapy were enrolled prospectively. Dyspnea was graded according to Common Terminology Criteria for Adverse Events version 3.0 prior to and weekly during RT. V/Q SPECT-computed tomography (CT) and PFTs were performed prior to and during RT at approximately 45 Gy. Functions of V and Q activities were assessed using a semiquantitative scoring of SPECT images. Results: Breathing improved significantly at the third week (mean dyspnea grade, 0.8 vs. 0.6; paired t-test p = 0.011) and worsened during the later course of RT (p > 0.05). Global PFT results did not change significantly, while regional lung function on V/Q SPECT improved significantly after {approx}45 Gy. The V defect score (DS) was 4.9 pre-RT versus 4.3 during RT (p = 0.01); Q DS was 4.3 pre-RT versus 4.0 during RT (p < 0.01). Improvements in V and Q functions were seen primarily in the ipsilateral lung (V DS, 1.9 pre-RT versus 1.4 during RT, p < 0.01; Q DS, 1.7 pre-RT versus 1.5 during RT, p < 0.01). Baseline primary tumor volume was significantly correlated with pre-RT V/Q DS (p < 0.01). Patients with central lung tumors had greater interval changes in V and Q than those with more peripheral tumors (p <0.05 for both V and Q DS). Conclusions: Regional ventilation and perfusion improved during RT at 45 Gy. This suggests that adaptive planning based on V/Q SPECT during RT may allow sparing of functionally recoverable lung tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ATM Polymorphisms Are Associated With Risk of Radiation-Induced Pneumonitis

Purpose: Since the ataxia telangiectasia mutated (ATM) protein plays crucial roles in repair of double-stranded DNA breaks, control of cell cycle checkpoints, and radiosensitivity, we hypothesized that variations in this gene might be associated with radiation-induced pneumonitis (RP). Methods and Materials: A total of 253 lung cancer patients receiving thoracic irradiation between 2004 and 2006 were included in this study. Common Terminology Criteria for Adverse Events version 3.0 was used to grade RP. Five haplotype-tagging single nucleotide polymorphisms (SNPs) in the ATM gene were genotyped using DNA from blood lymphocytes. Hazard ratios (HRs) and 95% confidence intervals (CIs) of RP for genotypes were computed by the Cox model, adjusted for clinical factors. The function of the ATM SNP associated with RP was examined by biochemical assays. Results: During the median 22-month follow-up, 44 (17.4%) patients developed grade {>=} 2 RP. In multivariate Cox regression models adjusted for other clinical predictors, we found two ATM variants were independently associated with increased RP risk. They were an 111G > A) polymorphism (HR, 2.49; 95% CI, 1.07-5.80) and an ATM 126713G > A polymorphism (HR, 2.47; 95% CI, 1.16-5.28). Furthermore, genotype-dependent differences in ATM expression were demonstrated both in cell lines (p < 0.001) and in individual lung tissue samples (p = 0.003), which supported the results of the association study. Conclusions: Genetic polymorphisms of ATM are significantly associated with RP risk. These variants might exert their effect through regulation of ATM expression and serve as independent biomarkers for prediction of RP in patients treated with thoracic radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portable Intravenous Fluid Production Device For Ground Use Project

Several medical conditions require the administration of intravenous (IV) fluids,but limitations of mass, volume, shelf-life, transportation, and local resources can restrict the availability of these important fluids. Such limitations are expected in long-duration space exploration missions and in remote or austere places on Earth. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endo - toxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (≈25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters. The device contains one battery powered electric mini-pump. Alternatively, a manually powered pump can be attached and used. Drinking water enters the device from a source water bag, flows through two filters, and final sterile production water exits into a sealed, medical-grade collection bag. The collection bag contains pre-placed crystalline salts to mix with product water to form isotonic intravenous medical solutions. Alternatively, a hypertonic salt solution can be injected into a filled bag. The filled collection bag is detached from the device and is ready for use or storage. This device currently contains one collection bag, but a manifold of several pre-attached bags or replacement of single collection bags under sterile needle technique is possible for the production of multiple liters. The entire system will be flushed, sealed, and radiation-sterilized. Operation of the device is easy and requires minimal training. Drinking water is placed into the collection bag. Inline stopcock flow valves at the source and collection bags are opened, and the mini-pump is turned on by a switch to begin fluid flow. When the collection bag is completely filled with the medical- grade water, the pump can be turned off. The pump is designed so it cannot pump air, and overfilling of the collection bag with fluid is avoided by placing an equal amount of water in the source bag. Backflow is avoided by inline check valves. The filled collection bag is disconnected from its tubing and is ready for use. The source bag can be refilled for production of multiple liters, or the source bag can be replaced with an input tube that can be placed in a larger potable water source if the device is attended. The device functions in all orientations independent of any gravity fields. In addition to creating IV fluids, the device produces medical-grade water, which can be used for mixing with medications for injection, reconstituting freeze-dried blood products for injection, or for wound hydration or irrigation. Potential worldwide use is expected with medical activities in environments that have limited resources, storage, or resupply such as in military field operations, humanitarian relief efforts, submarines, commercial cruise ships, etc.

Technology Portfolio System↗

Quality of Life and Toxicity From Passively Scattered and Spot-Scanning Proton Beam Therapy for Localized Prostate Cancer

Purpose: To report quality of life (QOL)/toxicity in men treated with proton beam therapy for localized prostate cancer and to compare outcomes between passively scattered proton therapy (PSPT) and spot-scanning proton therapy (SSPT). Methods and Materials: Men with localized prostate cancer enrolled on a prospective QOL protocol with a minimum of 2 years' follow-up were reviewed. Comparative groups were defined by technique (PSPT vs SSPT). Patients completed Expanded Prostate Cancer Index Composite questionnaires at baseline and every 3-6 months after proton beam therapy. Clinically meaningful differences in QOL were defined as ≥0.5 × baseline standard deviation. The cumulative incidence of modified Radiation Therapy Oncology Group grade ≥2 gastrointestinal (GI) or genitourinary (GU) toxicity and argon plasma coagulation were determined by the Kaplan-Meier method. Results: A total of 226 men received PSPT, and 65 received SSPT. Both PSPT and SSPT resulted in statistically significant changes in sexual, urinary, and bowel Expanded Prostate Cancer Index Composite summary scores. Only bowel summary, function, and bother resulted in clinically meaningful decrements beyond treatment completion. The decrement in bowel QOL persisted through 24-month follow-up. Cumulative grade ≥2 GU and GI toxicity at 24 months were 13.4% and 9.6%, respectively. There was 1 grade 3 GI toxicity (PSPT group) and no other grade ≥3 GI or GU toxicity. Argon plasma coagulation application was infrequent (PSPT 4.4% vs SSPT 1.5%; P=.21). No statistically significant differences were appreciated between PSPT and SSPT regarding toxicity or QOL. Conclusion: Both PSPT and SSPT confer low rates of grade ≥2 GI or GU toxicity, with preservation of meaningful sexual and urinary QOL at 24 months. A modest, yet clinically meaningful, decrement in bowel QOL was seen throughout follow-up. No toxicity or QOL differences between PSPT and SSPT were identified. Long-term comparative results in a larger patient cohort are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Genetic Variants of NPAT-ATM and AURKA are Associated With an Early Adverse Reaction in the Gastrointestinal Tract of Patients With Cervical Cancer Treated With Pelvic Radiation Therapy

Purpose: This study sought to associate polymorphisms in genes related to cell cycle regulation or genome maintenance with radiotherapy (RT)-induced an early adverse reaction (EAR) in patients with cervical cancer. Methods and Materials: This study enrolled 243 cervical cancer patients who were treated with pelvic RT. An early gastrointestinal reaction was graded using the National Cancer Institute Common Toxicity Criteria, version 2. Clinical factors of the enrolled patients were analyzed, and 208 patients were grouped for genetic analysis according to their EAR (Grade {<=}1, n = 150; Grade {>=}2, n = 58). Genomic DNA was genotyped, and association with the risk of EAR for 44 functional single-nucleotide polymorphisms (SNPs) of 19 candidate genes was assessed by single-locus, haplotype, and multilocus analyses. Results: Our analysis revealed two haplotypes to be associated with an increased risk of EAR. The first, comprising rs625120C, rs189037T, rs228589A, and rs183460G, is located between the 5' ends of NPAT and ATM (OR = 1.86; 95% CI, 1.21-2.87), whereas the second is located in the AURKA gene and comprises rs2273535A and rs1047972G (OR = 1.75; 95% CI, 1.10-2.78). A third haplotype, rs2273535T and rs1047972A in AURKA, was associated with a reduced EAR risk (OR = 0.42; 95% CI, 0.20-0.89). The risk of EAR was significantly higher among patients with both risk diplotypes than in those possessing the other diplotypes (OR = 3.24; 95% CI, 1.52-6.92). Conclusions: Individual radiosensitivity of intestine may be determined by haplotypes in the NPAT-ATM and AURKA genes. These variants should be explored in larger association studies in cervical cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypofractionated Intensity Modulated Radiation Therapy in Combined Modality Treatment for Bladder Preservation in Elderly Patients With Invasive Bladder Cancer

Purpose/Objective(s): To review our experience with bladder-preserving trimodality treatment (TMT) using hypofractionated intensity modulated radiation therapy (IMRT) for the treatment of elderly patients with muscle-invasive bladder cancer. Methods and Materials: Retrospective study of elderly patients treated with TMT using hypofractionated IMRT (50 Gy in 20 fractions) with concomitant weekly radiosensitizing chemotherapy. Eligibility criteria were as follows: age ≥70 years, a proven diagnosis of muscle-invasive transitional cell bladder carcinoma, stage T2-T3N0M0 disease, and receipt of TMT with curative intent. Response rate was assessed by cystoscopic evaluation and bladder biopsy. Results: 24 patients with a median age of 79 years were eligible. A complete response was confirmed in 83% of the patients. Of the remaining patients, 1 of them underwent salvage cystectomy, and no disease was found in the bladder on histopathologic assessment. After a median follow-up time of 28 months, of the patients with a complete response, 2 patients had muscle-invasive recurrence, 1 experienced locoregional failure, and 3 experienced distant metastasis. The overall and cancer-specific survival rates at 3 years were 61% and 71%, respectively. Of the surviving patients, 75% have a disease-free and functioning bladder. All patients completed hypofractionated IMRT, and 19 patients tolerated all 4 cycles of chemotherapy. Acute grade 3 gastrointestinal or genitourinary toxicities occurred in only 4% of the patients, and acute grade 3 or 4 hematologic toxicities, liver toxicities, or both were experienced by 17% of the cohort. No patient experienced grade 4 gastrointestinal or genitourinary toxicity. Conclusions: Hypofractionated IMRT with concurrent radiosensitizing chemotherapy appears to be an effective and well-tolerated curative treatment strategy in the elderly population and should be considered for patients who are not candidates for cystectomy or who wish to avoid cystectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal Binding Affinity for Sieving Separation of Propylene from Propane in an Oxyfluoride Anion-Based Metal–Organic Framework

Highly efficient adsorptive separation of propylene from propane offers an ideal alternative method to replace the energy-intensive cryogenic distillation technology. Molecular sieving-type separation via high-performance adsorbents is targeted for superior selectivity, but the limit in adsorption capacity remains a great challenge. Here, we report an oxyfluoride-based ultramicroporous metal–organic framework UTSA-400, [Ni(WO 2 F 4 )(pyz) 2 ] (pyz = pyrazine), featuring one-dimensional pore channels that can accommodate the propylene molecules with optimal binding affinity while specifically excluding the propane molecules. The exposed oxide/fluoride pairs in UTSA-400 serve as strong functional sites for strengthened propylene–host interactions, accounting for a significantly enhanced propylene uptake, while the propane molecules are excluded due to the regulated host framework dynamics. The strong propylene binding enables near-saturation of propylene in the pore confinement at ambient conditions, leading to full utilization of pore space and superior packing density. Combined in situ infrared spectroscopy measurements and dispersion-corrected density functional theory calculations clearly unveil the nature of boosted host–guest binding. Direct production of polymer-grade (>99.5%) propylene with remarkable dynamic productivity is demonstrated by column breakthrough experiments. Furthermore, this work presents an example of pore engineering with atomic precision to break the trade-off in adsorptive separation through guest binding optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Damage Tolerance of Advanced SiC/SiC Composites after Neutron Irradiation

Silicon carbide composites (SiC/SiC) are attractive candidate materials for structural and functional components in fusion energy systems. The effect of neutron irradiation on damage tolerance of the nuclear grade SiC/SiC composites (plain woven HiNicalon™ Type-S reinforced CVI matrix composites multilayer interphase and unidirectional Tyranno™-SA3 reinforced NITE matrix with carbon mono-layer interphase) was evaluated by means of miniaturized single-edged notched beam test. No significant changes in crack extension behavior and in the load-loadpoint displacement characteristics such as the peak load and hysteresis loop width were observed after irradiation to 5.9 × 1025 n/m2 (E > 0.1 MeV) at 800oC and to 5.8 × 1025 n/m2 at 1300oC. By applying a global energy balance analysis based on non-linear fracture mechanics, the energy release rate for these composite materials was found to be unchanged by irradiation with a value of 3±2 kJ/m2. This has led to the conclusion that, for these fairly aggressive irradiation conditions, the effect of neutron irradiation on the fracture resistance of these composites appears insignificant.

Ozawa, Kazumi↗

Functional Data Analysis in NTCP Modeling: A New Method to Explore the Radiation Dose-Volume Effects

Purpose/Objective(s): To describe a novel method to explore radiation dose-volume effects. Functional data analysis is used to investigate the information contained in differential dose-volume histograms. The method is applied to the normal tissue complication probability modeling of rectal bleeding (RB) for patients irradiated in the prostatic bed by 3-dimensional conformal radiation therapy. Methods and Materials: Kernel density estimation was used to estimate the individual probability density functions from each of the 141 rectum differential dose-volume histograms. Functional principal component analysis was performed on the estimated probability density functions to explore the variation modes in the dose distribution. The functional principal components were then tested for association with RB using logistic regression adapted to functional covariates (FLR). For comparison, 3 other normal tissue complication probability models were considered: the Lyman-Kutcher-Burman model, logistic model based on standard dosimetric parameters (LM), and logistic model based on multivariate principal component analysis (PCA). Results: The incidence rate of grade ≥2 RB was 14%. V{sub 65Gy} was the most predictive factor for the LM (P=.058). The best fit for the Lyman-Kutcher-Burman model was obtained with n=0.12, m = 0.17, and TD50 = 72.6 Gy. In PCA and FLR, the components that describe the interdependence between the relative volumes exposed at intermediate and high doses were the most correlated to the complication. The FLR parameter function leads to a better understanding of the volume effect by including the treatment specificity in the delivered mechanistic information. For RB grade ≥2, patients with advanced age are significantly at risk (odds ratio, 1.123; 95% confidence interval, 1.03-1.22), and the fits of the LM, PCA, and functional principal component analysis models are significantly improved by including this clinical factor. Conclusion: Functional data analysis provides an attractive method for flexibly estimating the dose-volume effect for normal tissues in external radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Snakelike nonautonomous solitons in a graded-index grating waveguide

We present a series of analytical solutions which describe nonautonomous solitons in a planar waveguide with an additional periodical structure, that is, a long-period grating. The explicit functions which describe the evolution of the width, peak, and trajectory of the soliton's wave center are presented exactly. The gain parameter has no effects on the motion of the soliton's wave center or its width; it affects just the evolution of the soliton's peak. The grating term affects the motion of the soliton's wave center without changing its shape. The evolution of the soliton under the propagation-distance-dependent gain term is investigated too. It is reported that an arbitrary additional structure can be added on the graded-index waveguide to control the motion of the soliton without affecting its shape.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-Dimensional Reconstruction and Microstructure Modeling of Porosity-Graded Cathode Using Focused Ion Beam and Homogenization Techniques

In this study, microstructure of a porosity-graded lanthanum strontium manganite (LSM) cathode of solid oxide fuel cells (SOFCs) has been characterized using focused ion beam (FIB) and scanning electron microscopy(SEM) combined with image processing. Two-point correlation functions of the two-dimensional (2D) images taken along the direction of porosity gradient are used to reconstruct a three-dimensional (3D) microstructure. The effective elastic modulus of the two-phase porosity-graded cathode is predicted using strong contrast (SC) and composite inclusion (CI) homogenization techniques. The effectiveness of the two methods in predicting the effective elastic properties of the porositygraded LSM cathode is investigated in comparison with the results obtained from the finite element model (FEM).

25 ENERGY STORAGE↗

Mutual Information and Information Gating in Synfire Chains

Here, coherent neuronal activity is believed to underlie the transfer and processing of information in the brain. Coherent activity in the form of synchronous firing and oscillations has been measured in many brain regions and has been correlated with enhanced feature processing and other sensory and cognitive functions. In the theoretical context, synfire chains and the transfer of transient activity packets in feedforward networks have been appealed to in order to describe coherent spiking and information transfer. Recently, it has been demonstrated that the classical synfire chain architecture, with the addition of suitably timed gating currents, can support the graded transfer of mean firing rates in feedforward networks (called synfire-gated synfire chains—SGSCs). Here we study information propagation in SGSCs by examining mutual information as a function of layer number in a feedforward network. We explore the effects of gating and noise on information transfer in synfire chains and demonstrate that asymptotically, two main regions exist in parameter space where information may be propagated and its propagation is controlled by pulse-gating: a large region where binary codes may be propagated, and a smaller region near a cusp in parameter space that supports graded propagation across many layers.

59 BASIC BIOLOGICAL SCIENCES↗

Preoperative Intensity-Modulated Radiotherapy Combined with Temozolomide for Locally Advanced Soft-Tissue Sarcoma

Purpose: To evaluate the toxicity and efficacy of preoperative intensity-modulated radiotherapy (IMRT) combined with temozolomide to improve local tumor control in soft-tissue sarcoma (STS). Patients and Methods: A cohort of 15 consecutive patients with nonmetastasized, primary high-grade or locally recurrent Stage III (n = 14) or IIb (n = 1) STS not amenable to surgical resection without significant organ or extremity function loss was prospectively investigated. Median tumor size was 9.8 cm, and most tumors were non-extremity sarcomas. Patients preoperatively received 50 mg/m{sup 2} of temozolomide during IMRT (50.4 Gy). Resection was intended 6 weeks thereafter. Toxicity was assessed by the National Cancer Institute Common Terminology Criteria for Adverse Events version 3.0, and response was assessed by Response Evaluation Criteria in Solid Tumors. Results: Of 15 patients, 14 completed preoperative treatment. No Grade 4 toxicities occurred. Nausea and vomiting were the most frequent Grade 3 toxicities. The most frequent toxicities of any grade were dermatologic, gastrointestinal, and hematologic. Response was partial response in 5, stable disease in 7, and progressive disease in 2 patients. Ten patients underwent surgery: 7 were resected with clear margins (R0), and 2 patients had an R1 resection; in 1 patient the tumor was not resectable. Postoperative complications occurred in 4 patients. Five patients did not undergo surgery because of intercurrent metastatic disease, unresectable disease, or refusal. Conclusions: Preoperative chemoradiation with temozolomide and IMRT can be administered safely and with promising efficacy in patients with locally advanced STS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-Institutional Experience of Ductal Carcinoma In Situ in Black vs White Patients Treated With Breast-Conserving Surgery and Whole Breast Radiation Therapy

Purpose: Given the paucity of data on racial disparities in ductal carcinoma in situ (DCIS), the data from a multi-institutional cohort of DCIS patients treated with breast-conserving surgery and whole breast radiation therapy (RT) were analyzed to determine whether racial disparities or differences exist. Methods and Materials: A total of 533 white and 76 black DCIS patients from 3 university-based cancer centers were uniformly treated with breast-conserving surgery and RT. All patient data were collected and analyzed as a function of race. Results: The median follow-up was 5.2 years. No significant racial differences were seen in tumor size, age at diagnosis, estrogen receptor status, necrosis, or grade (all P>.05). Of the treatment parameters, the RT dose delivered, boost, positive margin rates, frequency of hormone receptor status assessment, and receipt of hormonal therapy for the 2 cohorts did not significantly differ (all P>.05). The local relapse-free survival was similar at 5 years (96.1% and 98.1%, P=.399) and 10 years (92.8% vs 95.8%, P=.360), with no significant overall survival difference at 10 years (94.0% vs 88.9%, P=.290) between the white and black patients, respectively. On multivariate analysis, race was not an independent predictor of local relapse-free survival or overall survival when accounting for age, grade, and margin status. Conclusion: In our large cohort of DCIS patients uniformly treated at 3 institutions with breast conservation without any apparent differences in treatment delivery parameters, we demonstrated that the clinical and pathologic features and local survival outcomes did not differ as a function of race. Our results suggest that when black patients with DCIS are appropriately selected for breast conservation and receive adjuvant RT without racial disparities in the treatment parameters, differences in the outcomes as a function of race do not exist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of Coherent Lidar Performance Using Graded- Reflectance Transmitter Resonator Optics in the Low Equivalent Fresnel Number Region

Using a diffractive eigenmode treatment to model the laser output, we show that graded-reflectance resonator optics offer significant efficiency benefits over conventional hard-edge coupled unstable resonators in the context of coherent detection lidar applications. Extending previous work pertinent to the high equivalent Fresnel number regime, we have modelled the optimum performance of a notional super-Gaussian coupled cavity as a function of the key resonator parameters in the low equivalent Fresnel number regime.

lidar graded-reflectance transmitter resonator↗