Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fuel Cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Meso-Structured Polymer Electrolyte Fuel Cell Electrode

Increasing the utilization of Pt and Pt alloy catalysts in polymer electrolyte fuel cell cathodes is critical to improving the high power density operation, particularly at low Pt loadings. State of the art electrodes are fabricated in an ink deposition process that leads to uncontrolled electrode architecture with random aggregates of functional domains (catalyst, ionomer, and pore volume) (1). The randomness in the domains induces high tortuosity transport pathways for ions and fluids, which cause severe transport resistance during high current density operation. Thin ionomer films cause additional transport resistance and poisoning of the Pt catalyst, which becomes more significant at low Pt loadings. Reducing the amount of ionomer in the catalyst domain without affecting the ionic transport resistance is key to improving the utilization of the Pt and reducing the transport resistance at low Pt loading. Rational design of the electrode structure with controlled low tortuous ionic transport pathways could improve performance. The introduction of the ionomer pathways could also enable reduction of the ionomer volume in the catalyst domain, reducing the transport resistance. Middelmen et al. proposed electrode structures consisting of aligned components in a low tortuosity configuration to improve performance (2). In this work, we present an alternative electrode structure based on a vertically aligned array of Nafion pillars in the cathode catalyst layer, as shown in Figure 1a. Figure 1b shows the SEM image of the Nafion pillars. Furthermore, Pt supported on carbon catalyst was deposited on the Nafion pillars to fabricate a meso-structured electrode. Nafion pillars provide high conductive and low tortuous pathways for protons, reducing the effective transport distance, and enabling reduction of the ionomer binder in the catalyst domain.

25 ENERGY STORAGE↗

Influence of electronic transport on electrochemical performance of (Cu,Mn) 3 O 4 solid oxide fuel cell cathodes

Alkaline Earth free spinel oxides provide a potential benefit over Sr-doped perovskite-based materials commonly used as electrodes in high-temperature electrochemical energy conversion devices, e.g., solid oxide fuel cells (SOFCs). Sr-segregation is a known issue leading to performance degradation. In this study, Cu x Mn 3-x O 4 (x = 1, 1.2, and 1.5) porous electrodes were examined as SOFC cathodes using electrochemical impedance spectroscopy to investigate the oxygen reduction reaction (ORR) kinetics in relation to the material's intrinsic conductivity, the extrinsic electrode structure, and the cell test design. Similar to the electronic conducting (La,Sr)MnO 3 SOFC cathodes, the ORR kinetics of Cu x Mn 3-x O 4 spinel electrodes was governed by the oxygen adsorption and diffusion at the particle surface as well as the charge transfer at the triple phase boundaries. The overall electrode polarization resistance was highly dependent on contact density with the metallic current collector, active material particle connectivity, electrode thickness, and the intrinsic electronic materials conductivity. Here, we describe the importance of effective electronic charge transport parallel to the electrode surface in maximizing the electrochemically active electrode volume and enhancing electrode performance. We discuss an approach to optimize cell and electrode design with respect to active materials properties. This aspect is critical to ensure reliable evaluation of new materials, since laboratory-scale button-cells typically exhibit a high degree of electrode microstructure (e.g. porosity, thickness) and electrical contact density variation from sample to sample.

(Cu,Mn)3O4↗

Multi-Constituent Airborne Contaminants Capture with Low Cost Oxide Getters and Mitigation of Cathode Poisoning in Solid Oxide Fuel Cell

The technical effort and scientific findings, discussed in this report, documents operational barriers and associated long term performance stability challenges posed by the presence of trace airborne multi-constituent contaminants present in high-temperature electrochemical systems, including Solid Oxide Fuel Cells (SOFCs), Solid Oxide Electrolysis Cells (SOECs), Ion Transport Membranes, and Gas Separation systems. Above systems, offering promises for cleanliness and energy efficiency, face challenges with electrode poisoning stemming from the presence of trace contaminants including gaseous Cr/B/Si vapors in the presence of intrinsic contaminants SO 2 /CO 2 /H 2 O gases. The study indicates that the long-term electrical performance degradation in SOFC systems can be traced to electrochemical, structural, and mechanical changes across cell, stack, and balance of plant components resulting from interactions with trace contaminants leading to increase in both ohmic and non-ohmic polarizations. The degradation primarily results from solid-state and gas-phase materials migration, electrode poisoning, and interactions at the cell and stack levels. Cathode degradation emerges as a significant factor impacting overall SOFC performance, especially related to the presence of intrinsic and extrinsic airborne impurities such as SOx, CrOx(OH)y, SOx, Si(OH)x, and HBOx. Although at trace levels, prolong systems operation at higher airflow (3-10X stoichiometric) allow the accumulation of contaminants within the cell components leading to electrical performance degradation through poisoning and electrode deactivation.

20 FOSSIL-FUELED POWER PLANTS↗

Regulating in situ gaseous deposition to construct highly durable Fe–N–C oxygen-reduction fuel cell catalysts

The activity–stability trade-off challenges the design of high-performance atomically dispersed iron–nitrogen–carbon (Fe–N–C) catalysts for the acidic oxygen reduction reaction in polymer electrolyte fuel cells. Here we develop an in situ chemical vapour deposition approach during catalyst synthesis to break the trade-off, producing highly stable Fe–N–C catalysts while maintaining adequate oxygen reduction reaction activity. The optimal catalyst exhibits a half-wave potential of 0.867 V, remaining unchanged after an accelerated stress test (AST) of 100,000 potential cycles in rotating disk electrode tests. In membrane electrode assemblies under H 2 –air conditions, it delivers 93 mA cm −2 at 0.8 V after a standard AST of 30,000 voltage cycles, and shows minimal current density losses (2.9% at 0.6 V; 14.2% at 0.7 V) after an extended AST up to 120,000 cycles. Furthermore, the catalyst’s durability improvement is primarily due to the in situ chemical vapour deposition, which strengthens Fe–N bonds, increases active-site density, mitigates iron aggregates and reduces surface porosity.

Chemical engineering↗

High-performance ionomerless cathode anion-exchange membrane fuel cells with ultra-low-loading Ag–Pd alloy electrocatalysts

Rapid translation of catalysts from fundamental studies to high-performance devices could facilitate the process of developing and commercializing anion-exchange membrane fuel cells (AEMFCs). Traditionally, translation from material screening in three-electrode rotating disk electrode (RDE) cells to AEMFCs is complicated by differences in microenvironments, e.g. solid ionomer/membrane vs liquid electrolyte. Herein, we introduce a platform for translation to devices that utilizes ionomerless ultra-low-loading Ag-Pd alloy electrocatalyst cathodes synthesized by co-physical vapor deposition (PVD). Our ionomerless cathodes allow for systematic H 2 -O 2 AEMFC experiments while demonstrating comparable activity trends to those in three-electrode cells. Furthermore, here we show that our Ag 10 Pd 90 -based AEMFC reaches a peak power density of ~1 W cm$_{geo}^{-2}$ and ~10 W mg$_{PGM Cathode}^{-1}$ satisfying the U.S. Department of Energy’s platinum-group-metal (PGM) loading and cost targets. Our approach shows promise in facilitating the rapid translation between three-electrode studies and AEMFCs, offering a simple and effective design for decreasing PGM loadings.

25 ENERGY STORAGE↗

Fuel cell and electrolyzer hotbox module using conductive zirconia stacks

Modular pressurized hotbox for use and substitution in a variety of pressurized electrochemical applications to include reversible solid oxide electrolyzer and fuel cells, energy storage systems, renewable fuel production, solid-state hydrogen pumping and liquefaction, and oxygen transport membranes. This is enabled by mixed electronic and ionic conducting compositions of vanadia-yttria and vanadia-calcia stabilized zirconia and a dry powder method of manufacture for ceramic core stacks.

McLarty, Dustin↗

Regulating Catalytic Properties and Thermal Stability of Pt and PtCo Intermetallic Fuel-Cell Catalysts via Strong Coupling Effects between Single-Metal Site-Rich Carbon and Pt

Developing low platinum-group-metal (PGM) catalysts for the oxygen reduction reaction (ORR) in proton-exchange membrane fuel cells (PEMFCs) for heavy-duty vehicles (HDVs) remains a great challenge due to the highly demanded power density and long-term durability. Here, this work explores the possible synergistic effect between single Mn site-rich carbon (Mn SA -NC) and Pt nanoparticles, aiming to improve intrinsic activity and stability of PGM catalysts. Density functional theory (DFT) calculations predicted a strong coupling effect between Pt and MnN 4 sites in the carbon support, strengthening their interactions to immobilize Pt nanoparticles during the ORR. The adjacent MnN 4 sites weaken oxygen adsorption at Pt to enhance intrinsic activity. Well-dispersed Pt (2.1 nm) and ordered L1 2 -Pt 3 Co nanoparticles (3.3 nm) were retained on the Mn SA -NC support after indispensable high-temperature annealing up to 800 °C, suggesting enhanced thermal stability. Both PGM catalysts were thoroughly studied in membrane electrode assemblies (MEAs), showing compelling performance and durability. The Pt@Mn SA -NC catalyst achieved a mass activity (MA) of 0.63 A mg Pt –1 at 0.9 V iR-free and maintained 78% of its initial performance after a 30,000-cycle accelerated stress test (AST). The L1 2 -Pt 3 Co@Mn SA -NC catalyst accomplished a much higher MA of 0.91 A mg Pt –1 and a current density of 1.63 A cm –2 at 0.7 V under traditional light-duty vehicle (LDV) H 2 –air conditions (150 kPa abs and 0.10 mg Pt cm –2 ). Furthermore, the same catalyst in an HDV MEA (250 kPa abs and 0.20 mg Pt cm –2 ) delivered 1.75 A cm –2 at 0.7 V, only losing 18% performance after 90,000 cycles of the AST, demonstrating great potential to meet the DOE targets.

25 ENERGY STORAGE↗

Toward Optimizing Electrospun Nanofiber Fuel Cell Catalyst Layers: Polymer–Particle Interactions and Spinnability

We investigate the effect of the poly(acrylic acid) (PAA) carrier polymer concentration on the microstructure and rheological properties of catalyst inks for electrospun polymer–electrolyte membrane fuel-cell catalyst layers. Characterization of an ink microstructure using oscillatory shear rheology showed that the catalyst particles (platinum on carbon) are significantly agglomerated in the absence of PAA or an ionomer. Both the ionomer and PAA promoted the stability of the particles against agglomeration via electrosteric stabilization by adsorbing onto the particle surface. Increasing the PAA concentration increased the stability of the particles (or reduced the agglomerated structure) due to increasing PAA coverage onto the free surface area of the particles. However, beyond a certain increase in concentration, PAA was found to predominantly remain as an excess free polymer in the ink due to an insufficient free/available surface area on the particles for further PAA coverage. Extensional rheology measurements demonstrated that PAA enhances the extensional viscosities of the inks. Consequently, increasing the PAA concentration in the ink promoted the evolution of uniform nanofibers. However, beyond a certain concentration, a significant increase in the shear viscosities of the inks led to defective fiber morphologies because of the onset of flow instabilities. Electrochemical performance comparisons between catalyst layers with different PAA concentrations showed maximum performance at the PAA concentration that led to the least agglomerated structure of the catalyst, most uniform fiber morphologies, and low concentrations of free (non-adsorbing) PAA in the electrode. These results provide a rationale for optimization of electrospun catalyst nanofibers for both spinnability and electrochemical performance.

25 ENERGY STORAGE↗

Carbon Corrosion in Polymer Electrolyte Fuel Cells: A Complex Interplay between Morphological Changes and Electrochemical Performance

Due to the high gravimetric energy density of hydrogen, the focus of implementation of polymer electrolyte fuel cells (PEFCs) has shifted from light duty passenger vehicles to heavy duty vehicles such as buses, trucks, locomotives and marine vessels. A mechanistic understanding of degradation is therefore necessary to improve durability and efficiency. During start-up and shut-down (SUSD) of PEFC systems, the catalyst (Pt nanoparticles embedded on carbon support) undergoes local potentials ~ 1 - 1.5 V caused by a combination of fuel (H 2 ) starvation, mixed fuel region and cell reversal. This leads to a series of degradation phenomenon including reduction in cathode catalyst layer (cCL) thickness and porosity, loss in electrochemical surface area (ECSA), ionomer degradation and loss in electrical contact, therefore resulting in severe performance loss. The convoluted relationship between these individual degradation mechanisms, their chronology and their effects on electrochemical performance are yet unresolved. Here, the complex interplay between morphological changes due to carbon corrosion and its effects on the electrochemical performance were analyzed using a combination of detailed electrochemical characterization, spectroscopy, and electron microscopy techniques.

25 ENERGY STORAGE↗

Probing Heterogeneous Degradation of Catalyst in PEM Fuel Cells under Realistic Automotive Conditions with Multi-Modal Techniques

The heterogeneity of polymer electrolyte fuel cell catalyst degradation is studied under varied relative humidity and types of feed gas. Accelerated stress tests (ASTs) are performed on four membrane electrode assemblies (MEAs) under wet and dry conditions in an air or nitrogen environment for 30 000 square voltage cycles. The largest electrochemically active area loss is observed for MEA under wet conditions in a nitrogen gas environment AST due to constant upper potential limit of 0.95 V and significant water content. The mean Pt particle size is larger for the ASTs under wet conditions compared to dry conditions, and the Pt particle size under land is generally larger than under the channel. Observations from ASTs in both conditions and gas environments indicate that water content promotes Pt particle size growth. ASTs under wet conditions and an air environment show the largest difference in Pt particle size growth for inlet versus outlet and channel versus land, which can be attributed to larger water content at outlet and under land compared to inlet and under channel. From X-ray fluorescence experiments Pt particle size increase is a local phenomenon as Pt loading remains relatively uniform across the MEA.

25 ENERGY STORAGE↗

High-temperature low-humidity proton exchange membrane with “stream-reservoir” ionic channels for high-power-density fuel cells

The perfluorosulfonic acid (PFSA) proton exchange membrane (PEM) is the key component for hydrogen fuel cells (FCs). We used in situ synchrotron scattering to investigate the PEM morphology evolution and found a “stream-reservoir” morphology, which enables efficient proton transport. The short-side-chain (SSC) PFSA PEM is fabricated under the guidance of morphology optimization, which delivered a proton conductivity of 193 milliSiemens per centimeter [95% relativity humidity (RH)] and 40 milliSiemens per centimeter (40% RH) at 80°C. The improved glass transition temperature, water permeability, and mechanical strength enable high-temperature low-humidity FC applications. Performance improvement by 82.3% at 110°C and 25% RH is obtained for SSC-PFSA PEM FCs compared to Nafion polymer PEM devices. The insights in chain conformation, packing mechanism, crystallization, and phase separation of PFSAs build up the structure-property relationship. In addition, SSC-PFSA PEM is ideal for high-temperature low-humidity FCs that are needed urgently for high-power-density and heavy-duty applications.

25 ENERGY STORAGE↗

Fuel Cell Bus Evaluations

This presentation describes fiscal year 2021 status and accomplishments for NREL's fuel cell bus evaluations project.

bus↗

Status and challenges for the application of platinum group metal-free catalysts in proton-exchange membrane fuel cells

Platinum group metal-free (PGM-free) electrocatalysts are an important class of materials for the sustainable energy economy and significant effort has been made towards developing PGM-free catalysts to replace their costly Pt counterparts in fuel cell electric vehicles. The progress made in activity over the last decade is reviewed, along with synthesis strategies for more controlled active site formation and performance gains achieved through electrode engineering. The increased focus on durability, the growing understanding of degradation mechanisms, and the need for standard performance and accelerated stress test protocols are discussed.

25 ENERGY STORAGE↗

Parametric Study of the Influence of Support Type, Presence of Platinum on Support, and Ionomer Content on the Microstructure of Polymer Electrolyte Fuel Cell Catalyst Layers

We report Ultra-small angle X-ray scattering (USAXS) was employed to investigate the effects of carbon support type, the presence of platinum on carbon, and ionomer loading on the microstructure of polymer electrolyte fuel cell (PEFC) catalyst layers (CLs). Particle size distributions (PSDs), obtained from fitting the measured scattering data were used to interpret the size of carbon aggregates (40–300 nm) and agglomerates (>400 nm) from two-component carbon/ionomer and three-component platinum/carbon/ionomer CLs. Two types of carbon supports were investigated: high surface area carbon (HSC) and Vulcan XC-72. CLs with a range of perfluorosulfonic acid (PFSA) ionomer to carbon (I/C) ratios (0.2–1.2) and also with perfluoroimide acid (PFIA) ionomer were studied to evaluate the effect of ionomer on CL microstructure. The carbon type, the presence of platinum, and ionomer loading were all found to significantly impact carbon agglomeration. The extent of Pt/C agglomeration in the CL was found to increase with increasing ionomer and platinum concentration and to decrease with increasing carbon surface area. Platinum electrochemically-active surface area (ECSA) and local oxygen transport resistance (R nF ) were correlated to the CL microstructure to yield relationships affecting electrode performance.

25 ENERGY STORAGE↗

Modeling Impedance Caused by Ohmic Losses in High Surface Area Carbons in Polymer Electrolyte Fuel Cells

An analytical model for a blocking porous electrode is derived and used to predict how ohmic resistance inside micropores that host catalyst nanoparticles affects impedance. This paper revisits a widely used approach for estimating ionic conductivities of catalyst layers in fuel cells. An interfacial term associated with resistance in micropores is derived and added to the classical expression for the impedance of a blocking porous electrode at low frequency. The revised model predicts a physically realistic rise in the real component of the impedance at low frequency when reasonable pore dimensions and conductivities are used as inputs.

08 HYDROGEN↗