Bridging the ICS 'Communication Gap'
Protocol analytics for enabling forensics of industrial control systems.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Protocol analytics for enabling forensics of industrial control systems.
Face recognition technology has advanced significantly in recent years due largely to the availability of large and increasingly complex training datasets for use in deep learning models. These datasets, however, typically comprise images scraped from news sites or social media plat-forms and, therefore, have limited utility in more advanced security, forensics, and military applications. These applications require lower resolution, longer ranges, and ele-vated viewpoints. To meet these critical needs, we collected and curated the first and second subsets of a large multi-modal biometric dataset designed for use in the research and development (R&D) of biometric recognition technolo-gies under extremely challenging conditions. Thus far, the dataset includes more than 350,000 still images and over 1,300 hours of video footage of approximately 1,000 sub-jects. To collect this data, we used Nikon DSLR cameras, a variety of commercial surveillance cameras, specialized long-rage R&D cameras, and Group 1 and Group 2 UAV platforms. The goal is to support the development of algorithms capable of accurately recognizing people at ranges up to 1,000 m and from high angles of elevation. These ad-vances will include improvements to the state of the art in face recognition and will support new research in the area of whole-body recognition using methods based on gait and anthropometry. This paper describes methods used to col-lect and curate the dataset, and the dataset's characteristics at the current stage.
Combined-accelerated stress testing (C-AST) simultaneously combines stress factors of the natural environment (including UV radiation, temperature, humidity, electrical current, and external mechanical force) into a single test that requires fewer modules, fewer chambers, and makes it possible to discover weaknesses in new designs that are not known a-priori. C-AST reduces risk, accelerates time to market, and improves bankability by reducing costly overdesign using test levels not exceeding those seen in the natural environment. This project seeks to evaluate strengths and weaknesses of modern cell interconnect designs with combined-accelerated stress testing (C-AST) to screen multiple climates along with finite element and failure analysis to determine the potential for a 50-year life. Supporting this, we seek to develop methods of characterization to assess the degradation of interconnects, enable predictive rate models with material forensics and FEA and show C-AST's ability to find interconnect failures and benchmark it relative to other accelerated stress test methods like temperature cycling and cyclic dynamic mechanical loading. Examples of modern interconnect designs covered are Canadian Solar Hetero Technology ribbon enabling closer cell interconnections, SmartWire (eg. Meyer-Berger technology), and shingled cells with new interconnect materials.
Cyber Testing for Resilient Industrial Control Systems™ (CyTRICS™) is the Department of Energy’s (DOE’s) program for cybersecurity vulnerability testing, digital subcomponent enumeration, and forensic assessment. CyTRICS leverages best-in-class test facilities and analytic capabilities at six DOE National Laboratories and strategic partnerships with key stakeholders including technology developers, manufacturers, asset owners and operators, and interagency partners. During the program’s development, CyTRICS established a unique methodology for prioritizing digital components within operational technology (OT) and industrial control systems (ICS) in the Energy Sector Industrial Base (ESIB) for cyber vulnerability testing. The CyTRICS prioritization process leverages multiple characteristics of systems, components, and their contextual deployment to calculate a quantification of individual digital components for CyTRICS testing. The initial version of the CyTRICS prioritization process was premised largely upon the impact which could result to an energy sector industrial control system if the digital component under testing was compromised, either through malicious means, faulty engineering, or other modes. CyTRICS has termed this process the “CyTRICS Impact-based Prioritization Process.” This paper describes the factors identified for use in the Impact-based Prioritization process and identifies the rationale for inclusion. During development, three National Laboratories piloted this prioritization process and generated prioritization scores for seven systems. Following the piloting of the process, laboratory subject matter experts (SME) validated that the numerical scores generated by the prioritization process were consistent with their knowledge of the impact that may occur should any of these systems be disrupted. The following document explains how to perform the prioritization process to generate prioritization scores for energy sector systems. After outlining assumptions required to conduct the process, it describes how to identify and elicit data which can be leveraged to evaluate a system and assign numerical values for each factor. The prioritization process uses different weights on different factors; rationale for each weight is included within the paper. Additionally, the paper includes some recommendations for future enhancements to prioritization, including lessons learned from developing and piloting the process. Finally, a comprehensive appendix includes example documents to be leveraged by those looking to execute the prioritization process.
Over the past several years significant work has been performed at Idaho National Laboratory to build an alpha-particle spectrometry capability and expertise for a wide range of applications that include technical nuclear forensics, nuclear safeguards, and environmental monitoring. This development has led to a diverse collection of sample types and preparations measured with varied solid-state detector materials and configurations. Several characteristics of a measured alpha pulse height spectrum make performing localized fits of individual peak shapes unfeasible. Alternatively, the entirety of the spectrum must be fit concurrently to extract isotopic information. An analysis tool has been developed to perform isotopic characterization of alpha spectra. This process included a study of both the mathematical model used to represent the detector response of an alpha-particle as well as the algorithm used to fit the spectrum.
The Nuclear Forensics Analysis Center (NFAC) is a matrixed organization within the Savannah River National Laboratory that supports and is funded by the Federal Bureau of Investigation.
. With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accu rate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and as sociated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.
A method of sample collection includes collecting an analyte from a sampling surface using a rapidly curable liquid gel comprising one or more metal particles; co-aggregating the one or more metal particles from the rapidly curable liquid gel and the analyte from the sampling surface; and rapidly curing the rapidly curable liquid gel. The composition and sample preparation conditions may facilitate improved collection efficiency of analytes during environmental and forensic evidence sampling. In addition, the composition and sample preparation conditions may facilitate enhanced detection and identification of the analyte using e.g., Surface Enhanced Raman Spectrometry (SERS).
As the world looks to underground geological repositories for storing nuclear waste, technologies to safeguard the material are needed. An example of a project that developed a new technology is Tripwire. Tripwire proposes a multi-sensor system approach for geological spent nuclear fuel repositories that relies of radiation, vibration, and electromagnetic detection. Tripwire was developed by the Applied Radiation Measurements and Systems (ARMS) group at INL and sponsored by the National Nuclear Security Administration (NNSA). The ARMS group performs research and development, testing and evaluation, operational support, and training focused on applied ionizing radiation detection and measurement. Application areas include nuclear engineering for advanced reactors and fuel cycle operations, nuclear nonproliferation, nuclear counterproliferation, nuclear forensics, and arms control and disarmament.
HERMES is a novel visualization SAAS platform for achieving real-time visualization of large-scale environments involving cyber-energy devices. The platform receives data from emulated environments which include physical hardware and network devices that represent a complex IT / OT system. The platform is capable of streaming, filtering, storing, and visualizing all data within the environment and scaling vertically and horizontally. This capability enables high fidelity visual analysis of events to be performed in real time as well as the collection and storage of historical data for forensic analysis.
ABSTRACT Objective This study aimed to evaluate the reliability and validity of the Binge Eating Disorder Screener‐7 (BEDS‐7) across 42 countries and 26 languages, assessing its reliability and validity as a screening tool for binge‐eating disorder (BED) in diverse cultural contexts. Specifically, it sought to enhance early recognition of BED symptoms in primary care settings globally, contributing to a standardized framework for assessing BED. Method The International Sex Survey, a cross‐sectional online study, was conducted in 42 countries and 26 languages. A diverse community sample of 82,243 participants, aged 18 years or older, completed the BEDS‐7 and measures of sexuality, mental health, substance use, and sociodemographic characteristics. Confirmatory factor analyses and tests of measurement invariance were employed to evaluate the reliability and validity of the BEDS‐7 across languages, countries, genders, and sexual orientations. Results The BEDS‐7 demonstrated scalar factorial invariance across languages and countries, indicating consistent factor loadings and item intercepts. In contrast, the screener showed residual invariance across gender and sexual orientation groups, supporting its robustness across these demographics. Kruskal–Wallis tests revealed significant differences in BED symptoms across languages, countries, genders, and sexual orientations, with the highest BED scores observed among queer, pansexual, and gender‐diverse individuals. The BEDS‐7 also demonstrated adequate reliability (Cronbach's alpha > 0.80) and moderate criterion validity. Discussion The findings provide further evidence of the reliability and validity of the BEDS‐7 as a potential screening tool for identifying probable cases of BED globally, facilitating early intervention in primary care settings.
Abstract This study presents the development of polychlorinated biphenyl (PCB) background threshold values (BTVs) that statistically characterize ambient background conditions for surface waters in undeveloped and developed landscapes of the Pajarito Plateau in the Rio Grande Basin of New Mexico. Between 2009 and 2018, surface water data were collected at 45 locations under a variety of flow conditions and regimes. A total of 163 samples were collected, with roughly 1/3 of samples and locations being in undeveloped areas (n = 53 from 17 locations), and the remainder being in developed areas (n = 110 from 28 locations). While there are areas on the Pajarito Plateau where PCB point sources are known or likely to have contributed to PCBs in soils, PCB BTVs calculated for undeveloped portions of watersheds (upstream of areas where PCB point sources are known or likely to have contributed to PCBs in soils, and therefore not affected by PCB sources within the watershed) are well above New Mexico's human health organism-only (HH-OO) water quality criterion (0.64 ng/L). Background threshold values are even higher in developed areas upstream of managed soil sites, suggesting that in developed areas, both diffuse ambient PCB sources (e.g., atmospheric deposition) and localized urban sources (e.g., building materials, paints, and electrical equipment) contribute to PCBs in those watersheds. These findings indicate that New Mexico's current HH-OO water quality criterion for PCBs cannot practicably be met due to ambient conditions. It is also impracticable to meet the US Environmental Protection Agency (EPA) criterion continuous concentration (CCC) of 14 ng/L in developed background areas, where the BTV is approximately 1.5 times the CCC. Integr Environ Assess Manag 2023;19:1307–1319. © 2022 SETAC
Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.
Several studies have evaluated the morphology of uranium compounds produced under controlled conditions at the laboratory scale, but it is unclear whether the morphological characteristics of these materials persist in commercially produced uranium ore concentrates (UOCs). To assess the morphology in “real-world” UOCs, we qualitatively evaluated the morphological profile of secondary electron images from over 100 commercial UOCs using a previously published lexicon. We observe differences between samples with differing chemical composition and samples with similar chemical composition and differing provenance. Further, this work contextualizes morphology for commercially produced UOCs and will provide a basis for future machine learning efforts.
Here, the long-lived fission product 151 Sm (T 1/2 ≈ 90 y) present in archived dissolved Trinity nuclear test debris samples was analyzed using liquid scintillation counting and the results were compared to the expected values based upon historical analysis results. The measured 151 Sm activities were found to agree with the expected values within experimental error. This demonstration validates the use of this technique in situations where the sample is too old for traditional shorter half-life radioactive fission product signatures such as 99 Mo (T 1/2 = 2.75 d), 97 Zr (T 1/2 = 16.7 h), 147 Nd (T 1/2 = 10.98 d), and 153 Sm (T 1/2 = 46.3 h), or too dilute for determining fissions through stable isotope ratio measurements.
The distribution coefficients of 41 elements were determined on Eichrom’s Actinide resin in HCl and HNO 3 solutions of molarities between 0.01 M and 9 M. Herein a separation scheme for these 41 elements was designed utilizing these distribution coefficients that combines the Actinide resin with Eichrom’s TRU resin. Overall, these values improve the ability to create separations targeting specific analytes utilizing Actinide resin.
A rapid method to separate Ta, Po, Au, Pt, and W from a sample containing mixed fission and activation products was developed using three commercially available extraction chromatography resins stacked in series. When the separation was tested using all the target activation products, even those with short half-lives were measurable. Finally, combining multiple extraction chromatography resin cartridges in tandem allows for multiple short-lived activation products to be separated from one sample addition without the complication of multiple steps.
A method for depositing actinides directly onto a 4H-SiC Schottky barrier diode (SBD) detector as a field deployable actinides sensor was developed to enable off-site analysis, shortening the time to obtain critical information such as elements, concentration, and/or isotopic ratio related to the radiological situation. A thin film of Hg was first electrodeposited onto the Pt contact of the SiC diode, followed by chronoamperometric deposition of microgram levels of actinides under conventional control conditions. The 4H-SiC diode maintained consistent functionality through the electrodeposition process and showed resolved alpha-energy spectra that contained accurate isotopic information demonstrating the feasibility of a combined chemical and radiological sensor for field actinide detection and quantification.