Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Focuses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Automatic Focus Adjustment of a Microscope

AUTOFOCUS is a computer program for use in a control system that automatically adjusts the position of an instrument arm that carries a microscope equipped with an electronic camera. In the original intended application of AUTOFOCUS, the imaging microscope would be carried by an exploratory robotic vehicle on a remote planet, but AUTOFOCUS could also be adapted to similar applications on Earth. Initially control software other than AUTOFOCUS brings the microscope to a position above a target to be imaged. Then the instrument arm is moved to lower the microscope toward the target: nominally, the target is approached from a starting distance of 3 cm in 10 steps of 3 mm each. After each step, the image in the camera is subjected to a wavelet transform, which is used to evaluate the texture in the image at multiple scales to determine whether and by how much the microscope is approaching focus. A focus measure is derived from the transform and used to guide the arm to bring the microscope to the focal height. When the analysis reveals that the microscope is in focus, image data are recorded and transmitted.

Huntsberger, Terrance↗

The Focusing Optics X-Ray Solar Imager: FOXSI

The Focusing Optics x-ray Solar Imager (FOXSI) is a sounding rocket payload funded under the NASA Low Cost Access to Space program to test hard x-ray (HXR) focusing optics and position-sensitive solid state detectors for solar observations. Today's leading solar HXR instrument, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) provides excellent spatial (2 arcseconds) and spectral (1 keV) resolution. Yet, due to its use of an indirect imaging system, the derived images have a low dynamic range (typically <10) and sensitivity. These limitations make it difficult to study faint x-ray sources in the solar corona which are crucial for understanding the particle acceleration processes which occur there. Grazing-incidence x-ray focusing optics combined with position-sensitive solid state detectors can overcome both of these limitations enabling the next breakthrough in understanding impulsive energy release on the Sun. The FOXSI project is led by the Space Sciences Laboratory at the University of California, Berkeley. The NASA Marshall Space Flight Center is responsible for the grazing-incidence optics, while the Astro-H team at JAXA/ISAS has provided double-sided silicon strip detectors. FOXSI is a pathfinder for the next generation of solar hard x-ray spectroscopic imagers. Such observatories will be able to image the non-thermal electrons within the solar flare acceleration region, trace their paths through the corona, and provide essential quantitative measurements such as energy spectra, density, and energy content in accelerated electrons.

Krucker, Saem↗

Understanding the Impact of Meteorological Spatiotemporal Variability on Distant Focusing Overpressure Risk

Since the 1950s, the amplification of blast energy from explosions has been understood to be a significant hazard to public safety at launch ranges. Historically, the risk assessment of the Distant Focusing Overpressure (DFO) hazard started with a single temperature and wind profile (e.g., a radiosonde launch) as input to acoustic 1-D ray tracing models. By analyzing rays propagation and performing ray tracing, population centers under high DFO risk can be identified. Although this method is useful, less is known about how the blast waves can be focused when the spatiotemporal variability of the input profiles are considered. In summary, this work aims to consider how realistic atmospheric boundary layer variability (e.g., turbulence, land-surface contrasts) may affect blast waves propagation and focusing and, as a result, DFO risk assessment results.

Blumberg, W. Greg↗

Realistic gravitational focusing of meteoroid streams

A meteor shower can be modeled, to first order, as a parallel stream of particles encountering the Earth. Gravity bends the trajectories of these particles inward, producing an increase in flux both near the planet and along the anti-radiant line. This effect is known as gravitational focusing, and the interception of a portion of meteoroid trajectories by the Earth or another massive body is known as planetary shielding. For a perfectly parallel meteoroid stream, gravitational focusing produces a flux singularity along the anti-radiant line, near which intense enhancements in flux occur. In reality, meteoroids will exhibit some dispersion in their motion that removes this singularity. We present a modified analytic treatment of gravitational focusing and planetary shielding that takes this dispersion into account and discuss its ramifications for several problems in meteor astronomy.

Althea Valkyrie Moorhead↗

Multi-Point Line Focused Laser Differential Interferometer for High-Speed Flow Fluctuation Measurements

A multi-point focused laser differential interferometer (FLDI) has been developed to measure density fluctuations at 16 points along a line. A pair of cylindrical lenses on the transmitter side of a conventional single-point FLDI instrument form two closely spaced (≤200 μm), orthogonally polarized, parallel laser lines at the instrument’s focus. On the receiver side of the instrument, the interference of the beams on a 16-element photodiode array results in a single line of measurements. The further addition of a Nomarski prism creates two separate measurement lines, and the addition of a second photodiode array to the instrument enables simultaneous measurements of density fluctuations along the two lines separated by several millimeters. These two lines of measurement can be conveniently oriented at any azimuthal angle relative to the instrument’s optical axis on the measurement plane, coinciding with the instrument’s focus. Two experiments were performed to demonstrate the capabilities of the instrument. In the first experiment, a laser-induced breakdown spark generated a traveling spherical shock wave, and measurements of the resulting density disturbance and wave velocity were obtained. These results were compared to high-speed schlieren images of the shock wave acquired at 400 kHz. In the second experiment, the multi-point FLDI instrument was used to measure density disturbances in the boundary layer of a flat plate in a Mach 6 freestream flow. The measurements were made along two lines, both approximately 6 mm in length, extending from the surface of the plate through the boundary layer. High-speed schlieren images were acquired at 100 kHz during separate wind tunnel runs at matching unit Reynolds numbers to visualize the unsteady boundary layer flow and compare to the FLDI measurements.

Laser beam shaping↗

Development of a Self-Aligned Compact Focusing Schlieren System for NASA Test Facilities

A novel compact, inherently self-aligned focusing schlieren system is presented for use in experiments that require flow visualization. Unlike existing focusing schlieren systems that require a separate, and precisely aligned, source grid and cutoff grid to achieve sensitivity to density gradients, this system projects an image of a physical grid element onto a background and then reimages this projection back onto the physical grid element thereby achieving self-alignment. Further, unlike existing focusing schlieren systems where the image of the source grid is physically translated relative to the cutoff grid to achieve sensitivity to density gradients, a polarization prism in the system acts on the polarization state of the light of the projected grid element to provide sensitivity adjustment. By adjusting the position of the prism along the optical axis of the instrument, changes to the sensitivity can be realized. Since the outgoing and returning light used to project an image of the grid element are orthogonally polarized to one another, reflections from windows that may be present between the lens and background of the system can be eliminated. The system can also be implemented in test facilities where optical access is limited and/or exists on only one side. A discussion on different aspects of the development of this technology is provided, as are sample images from the system at the different stages of development. Images that demonstrate the ability to make on-the-fly adjustments to the instrument's field-of-view and working distance are also presented.

Brett F Bathel↗

A Science-Focused Artificial Intelligence (AI) Responding in Real-Time to New Information: Capability Demonstration for Ocean World Missions

Introduction: Artificial intelligence (AI) has long been considered a potential mechanism to explore increasingly challenging environments, including those with extreme temperatures and pressures, limited communication capabilities, or those with demanding terrain. We posit that missions in extreme environments could deploy an onboard AI focused on science observations and goals in order to augment a traditional concept(s) of operations (ConOps). An onboard AI capability could perform functions such as data analysis in order to make high-level decisions, including prioritized data transmission for analysis by ground-based teams or autonomously-guided follow-on analyses that maximize science return. Such a capability would empower missions to respond to scientific data of interest in real-time; a mission could make observations and perform a preliminary analysis to alert ground-based scientists to an observation of interest, enabling an informed, rapid response from Earth-based teams. Enceladus Case Study for Onboard AI: We are developing an onboard AI capability for real-time telemetry response that formulates and carries-out informed decisions in service to established mission goals, enabling increased science return of a mission. We focus our AI development for use on a constellation of SmallSats orbiting Enceladus. Our Enceladus case study tests autonomous decision-making capabilities in scenarios with complex orbital dynamics, plume ejecta, extreme cold environments, power restrictions, and a requirement to maximize science return for a potential positive detection of life, while critically evaluating the potential for false positives. Telemetry includes simulated scientific data, spacecraft onboard operational data (e.g., position, velocity, and rotation), and engineering hardware performance data. Enceladus SmallSat Constellation. Our constellation includes eight SmallSat spacecraft in an 8:35 resonant orbit-based formation, leveraging Saturn’s gravitational forces to maintain stable orbits with global coverage around Enceladus. To our knowledge, we simulate the first stable configuration of multiple spacecraft in closed orbits around Enceladus, using a full ephemeris force model (Russell and Lara, 2009). Each spacecraft’s orbit will precess, causing an eastward ground track shift (from an orbiter’s perspective) of each spacecraft for each orbit. However, all spacecraft return to their original positions relative to Enceladus after eight Enceladus revolutions around Saturn. We model communication pathways between SmallSats to understand how information would need to be transmitted across the constellation to enable AI-driven decision-making and resource allocation across the fleet. Capability Demonstration. Our simulated capability demonstration inputs position, velocity, and rotation telemetry from our Enceladus-focused constellation simulations, and mass spectrometry data collected from abiotic and biotic laboratory-analog ocean world experiments (Theiling et al., 2018; Theiling, 2021; Da Poian et al., 2023). Data from these experiments are used to simulate MS measurements and different scenarios of science observations for onboard analysis performed on each of the eight spacecraft. For these demonstrations, we integrate 24 machine learning (ML) algorithms into an onboard intelligence as a ‘knowledge base’, including algorithms evaluating data quality and those predicting (with % confidence) gas composition, ocean aqueous chemistry, and whether the sample was influenced by microbial life. The onboard AI capability is designed to use the knowledge base to come to a consensus-based decision in the interpretation of the observed data in order to request additional action outside of a pre-defined ConOps. Requested actions could include e.g., prioritized downlink to Earth (for analysis by ground-based teams) or follow-on analyses performed across the constellation. The spacecraft’s intelligent onboard planner must then determine whether sufficient resources (e.g., time, power, etc.) are available and weigh the request with mission priorities. In our simulation, the constellation is able to identify potential biosignatures using onboard ML algorithms, evaluate the confidence of that prediction, and perform follow-on analyses across the fleet to confirm the detection, in order to best prepare a transmission of these data to Earth-based teams.

astrobiology↗

High-Lift Prediction Workshop 5: Summary of Reynolds-Averaged Navier–Stokes Technology Focus Group Summary

The fifth High-Lift Prediction Workshop (HLPW-5), which involved the high-lift version of the NASA common research model in several configurations, assessed various computational fluid dynamics methods, including Reynolds-averaged Navier-Stokes (RANS) and hybrid large-eddy simulations. This paper summarizes RANS solutions computed on fixed grids. Case 1, a verification case, considered a simple wing-body configuration and focused on grid convergence of lift, drag, and pitching moment coefficients. Case 2 is a configuration buildup case that focused on predicting the effects of increasing geometric complexity. For buildup configurations with slats, flaps, and a nacelle/pylon (configurations 2.2, 2.3, and 2.4), wind-tunnel data were provided by ONERA. Case 3 focused on the reference landing configuration at four Reynolds-number conditions. For Case 1, grid-converged RANS solutions were achieved using the standard Spalart-Allmaras (SA) turbulence model and the SA model with a quadratic constitutive relation and a rotation correction. Agreement between RANS solutions was observed for the simplest configuration 2.1 of Case 2 with the standard SA model. For other configurations, agreement between RANS solutions was hampered by insufficient iterative and grid convergence, especially at high angles of attack. In comparison with the experiment, RANS solutions qualitatively showed the correct configuration buildup trend but underpredicted lift and overpredicted both drag and pitching moment at high angles of attack.

Boris Diskin↗

Operational Experiences Tuning the ATF2 Final Focus Optics Towards Obtaining a 37nm Electron Beam IP Spot Size

The primary aim of the ATF2 research accelerator is to test a scaled version of the final focus optics planned for use in next-generation linear lepton colliders. ATF2 consists of a 1.3 GeV linac, damping ring providing low-emittance electron beams (< 12pm in the vertical plane), extraction line and final focus optics. The design details of the final focus optics and implementation at ATF2 are presented elsewhere. The ATF2 accelerator is currently being commissioned, with a staged approach to achieving the design IP spot size. It is expected that as we implement more demanding optics and reduce the vertical beta function at the IP, the tuning becomes more difficult and takes longer. We present here a description of the implementation of the tuning procedures and describe operational experiences and performances.

43 PARTICLE ACCELERATORS↗

ASSESMENT OF IMPURITIES IN NP METAL USING DOUBLE-FOCUSING SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards [1]. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing [2], with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture [2]. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of na

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nondispersive neutron focusing method beyond the critical angle of mirrors

This invention extends the Kirkpatrick-Baez (KB) mirror focusing geometry to allow nondispersive focusing of neutrons with a convergence on a sample much larger than is possible with existing KB optical schemes by establishing an array of at least three mirrors and focusing neutrons by appropriate multiple deflections via the array. The method may be utilized with supermirrors, multilayer mirrors, or total external reflection mirrors. Because high-energy x-rays behave like neutrons in their absorption and reflectivity rates, this method may be used with x-rays as well as neutrons.

Ice, Gene E↗

Microfluidic device and method for focusing, segmenting, and dispensing of a fluid stream

A microfluidic device and method for forming and dispensing minute volume segments of a material are described. In accordance with the present invention, a microfluidic device and method are provided for spatially confining the material in a focusing element. The device is also adapted for segmenting the confined material into minute volume segments, and dispensing a volume segment to a waste or collection channel. The device further includes means for driving the respective streams of sample and focusing fluids through respective channels into a chamber, such that the focusing fluid streams spatially confine the sample material. The device may also include additional means for driving a minute volume segment of the spatially confined sample material into a collection channel in fluid communication with the waste reservoir.

47 OTHER INSTRUMENTATION↗

Sagittal focusing Laue monochromator

An x-ray focusing device generally includes a slide pivotable about a pivot point defined at a forward end thereof, a rail unit fixed with respect to the pivotable slide, a forward crystal for focusing x-rays disposed at the forward end of the pivotable slide and a rearward crystal for focusing x-rays movably coupled to the pivotable slide and the fixed rail unit at a distance rearward from the forward crystal. The forward and rearward crystals define reciprocal angles of incidence with respect to the pivot point, wherein pivoting of the slide about the pivot point changes the incidence angles of the forward and rearward crystals while simultaneously changing the distance between the forward and rearward crystals.

47 OTHER INSTRUMENTATION↗

Influence of Nitrogen on Hydrogenated Amorphous Carbon Thin Films Deposited by Plasma Focus Device

To carry out our research, a plasma focus device is used to deposit thin films of nitrogen doped hydrogenated amorphous carbon (a-C:H:N) onto the stainless steel-AISI-304 substrates at room temperature. Thin films are deposited with the same numbers of focus shots, at the same distance from the anode tip and with different partial pressures of nitrogen in the mixtures of acetylene/nitrogen as working gas. The nitrogen contents of deposited films are studied using nuclear reaction analysis (NRA) techniques. The results prove that nitrogen contents of the samples do not increase significantly by increasing partial pressure of nitrogen of the working gas for both sets of the samples. Moreover, NRA results exhibit the limitation of nitrogen incorporated into the samples, when this experimental setup is used. G-peak position and peak intensity ratio of the D-band to G-band (I{sub D}/I{sub G}) are used to investigate the diamond characters. Also, they show that sp{sup 2} clustering is highly dependent on the nitrogen atomic contents and angular position of the samples. Scanning electron microscopy (SEM) shows the granular surface morphology of the films. Furthermore, it shows that angular position of the samples with respect to the anode axis plays an important role in the grain size of the surface of the samples. The thickness of the films decreases significantly by increasing angular position of the samples, while it decreases slightly by increasing partial pressure of nitrogen of the working gas. The Vickers surface hardness of the thin films exhibits significant dependency on the sp{sup 2} clustering.

36 MATERIALS SCIENCE↗

Optical analysis for simplified astigmatic correction of non-imaging focusing heliostat

In the previous work, non-imaging focusing heliostat that consists of m x n facet mirrors can carry out continuous astigmatic correction during sun-tracking with the use of only (m + n - 2) controllers. For this paper, a simplified astigmatic correction of non-imaging focusing heliostat is proposed for reducing the number of controllers from (m + n - 2) to only two. Furthermore, a detailed optical analysis of the new proposal has been carried out and the simulated result has shown that the two-controller system can perform comparably well in astigmatic correction with a much simpler and more cost effective design. (author)

14 SOLAR ENERGY↗

Estimation of the energy transferred from the capacitor bank to the plasma in plasma focus systems

We consider the snowplow model to describe the axial phase of a plasma focus device. We show that, within this framework, the dynamics of a given system can be recovered at different energetic and geometric scales. Then, we consider two different criteria that would plausibly optimize the plasma focus performance. By solving the dynamics equations for the axial phase, we estimate the values of the parameters that do indeed satisfy the aforementioned criteria and compare those values with the corresponding ones attached to few practical devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Studies of Ions Emission in a Small Plasma Focus Device of Hundreds of Joules

Ion beam emission in plasma focus (PF) discharges was originally investigated to explain the strong forward anisotropy observed in the neutron. Several properties of PF emitted deuteron beams have been measured, including their angular distributions and energy spectra in devices operating with energies from 1 kJ to 1 MJ. At present there is a growing interest in the development of very small PF devices operating under 1 kJ. As part of the characterization program of the very low energy PF devices (<1 kJ) developed at the Chilean Nuclear Energy Commission, the charges particle emission in hydrogen (H{sub 2}) and mixture (H{sub 2}+%Ar) are being studied. In order to obtain an estimation of the ions energy spectrum and ionization grade, by using time of flight method, a graphite collector system operating in the bias ion collector mode was constructed and it is being used. Preliminary results of the ion beams measurements in different experimental conditions, at a plasma focus device of 400 joules (PF-400 J) are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗