Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Surface diffusion activation energy determination using ion beam microtexturing

The activation energy for impurity atom (adatom) surface diffusion can be determined from the temperature dependence of the spacing of sputter cones. These cones are formed on the surface during sputtering while simultaneously adding impurities. The impurities form clusters by means of surface diffusion, and these clusters in turn initiate cone formation. Values are given for the surface diffusion activation energies for various materials on polycrystalline Cu, Al, Pb, Au, and Ni. The values for different impurity species on each of these substrates are approximately independent of impurity species within the experimental uncertainty, suggesting the absence of strong chemical bonding effects on the diffusion.

Rossnagel, S. M.↗

Energy Intensity Baselining and Tracking Guidance

Each company joining the U.S. Department of Energy’s (DOE’s) Better Buildings, Better Plants Program (Better Plants) commits to establishing an energy consumption and energy intensity (EI) baseline and to tracking its energy performance over a 10-year period against that baseline. The baseline must reflect a company’s energy consumption over a 12-month period, covering all its U.S.-based operations. Energy consumption is calculated by fuel type in terms of primary energy (also known as source energy). EI is broadly defined as the amount of energy consumed per unit of output produced. For this guidance document and for the program, the term energy performance represents an evaluation of a facility’s capacity to use energy efficiently. Metrics used to assess a facility’s energy performance can include EI, energy consumption, improvements in EI, etc. Establishing an energy baseline and tracking system is a critical first step in effectively managing energy use. Developing a baseline can help a company understand energy use within the corporation and give it a point of comparison to evaluate future efforts to improve energy performance. It can also support efforts to validate a company’s energy management activities, improve comparative analyses when using benchmarks, and help in predicting future energy needs. In addition, a company that normalizes its performance data can determine highly defensible measures of energy savings generated through implemented energy efficiency projects. Establishing a baseline and tracking energy performance is also a requirement for ISO 50001 certification. Although basic energy data can be collected through utility bills, most manufacturers will have to perform additional analyses to develop accurate and robust energy baselines and tracking systems. Energy is consumed in many ways within the manufacturing sector and can come from multiple sources. Energy is sometimes generated and sold to other parties or captured and reused on-site. External events can exert a significant impact on a facility or company’s energy use independent of any purposeful efforts to improve energy efficiency. Operational changes, such as production shifts—which may be inevitable for some companies over the 10-year period covered by the program—can also make a big difference in energy use. Since Better Plants asks companies to account for all their U.S.-based operations, mergers, acquisitions, and divestitures can also have significant implications for a company’s energy metrics. This document aims to demystify the sometimes complex baselining process. It devotes special attention to the task of normalizing and adjusting energy consumption to account for external factors, such as weather and production changes. A key recommendation is that companies use regression analysis to normalize their energy consumption data whenever possible. Regression analysis is a statistical technique that estimates the dependence of a variable (i.e., energy use in the context of Better Plants) on one or more independent variables such as ambient temperature, while controlling for the influence of other variables at the same time. A properly developed regression analysis can provide a reliable estimate of energy savings resulting from energy improvement strategies and projects by accounting for the effects of variables such as annual production levels and weather. DOE has developed a companion Energy Performance Indicator software tool (EnPI) to simplify the baselining process. This tool can run regression models, calculate changes in EI at the facility level, and automatically compile facility-level data into a corporate-wide metric. Note that although the relevant equations used to calculate EI are provided in this document, the EnPI tool will automatically perform most calculations for the user. Additionally, Better Plants Partners (Partners) can call on their Technical Account Manager (TAM) to help them establish a baseline and assist with the necessary calculations to track progress.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 2 Biomass Currently Used for Energy and Coproducts

Jacobson, R., and S. Curran. 2024. “Chapter 2: Biomass Currently Used for Energy and Coproducts.” In 2023 Billion‐Ton Report. M. H. Langholtz (Lead). Oak Ridge, TN: Oak Ridge National Laboratory. doi: 10.23720/BT2023/2316167.

BT23↗

Concepts of flywheels for energy storage using autostable high-T(sub c) superconducting magnetic bearings

A flywheel for energy storage using autostable high-T(sub c) superconducting magnetic bearings has been built. The rotating disk has a total weight of 2.8 kg. The maximum speed is 9240 rpm. A process that allows accelerated, reliable and reproducible production of melt-textured superconducting material used for the bearings has been developed. In order to define optimum configurations for radial and axial bearings, interaction forces in three dimensions and vertical and horizontal stiffness have been measured between superconductors and permanent magnets in different geometries and various shapes. Static as well as dynamic measurements have been performed. Results are being reported and compared to theoretical models.

Bornemann, Hans J.↗

Renewable Energy SCADA/Training Using NASA's Advanced Technology Communication Satellite

The lack of electrical energy in the rural communities of developing countries is well known, as is the economic unfeasibility of providing much needed energy to these regions via electric grids. Renewable energy (RE) can provide an economic advantage over conventional forms in meeting some of these energy needs. The use of a Supervisory Control and Data Acquisition (SCADA) arrangement via satellite could enable experts at remote locations to provide technical assistance to local trainees while they acquire a measure of proficiency with a newly installed RE system through hands-on training programs using the same communications link. Upon full mastery of the technologies, indigenous personnel could also employ similar SCADA arrangements to remotely monitor and control their constellation of RE systems. Two separate ACTS technology verification experiments (TVEs) have demonstrated that the portability of the Ultra Small Aperture Terminal (USAT) and the versatility of NASA's Advanced Communications Technology Satellite (ACTS), as well as the advantages of Ka band satellites, can be invaluable in providing energy training via distance education (DE), and for implementing renewable energy system SCADA. What has not been tested is the capabilities of these technologies for a simultaneous implementation of renewable energy DE and SCADA. Such concurrent implementations will be useful for preparing trainees in developing countries for their eventual SCADA operations. The project described in this correspondence is the first effort, to our knowledge, in this specific TVE. The setup for this experiment consists of a one-Watt USAT located at Florida Solar Energy Center (FSEC) connected to two satellite modems tuned to different frequencies to establish two duplex ACTS Ka-band communication channels. A short training program on operation and maintenance of the system will be delivered while simultaneously monitoring and controlling the hybrid using the same satellite communications link. The trainees will include faculty and students from Savannah State University, and staff from FSEC. An interactive internet link will be used to allow faculty from the University of West Indies to participate in the training session.

Kalu, A.↗

Remote Alaska Communities Energy Efficiency Competition: Energy Efficiency for the Gem of the Yukon (Final Report)

Over the past decade, the City of Ruby has been proactive in working to reduce cost and energy use in the community. Ruby (Tl’aa’ologhe) is a remote city in Alaska located on the south bank of the Yukon River near the Kilbuck-Kuskokwim Mountains, about 50 air miles east of Galena and 230 air miles west of Fairbanks. As of 2019, the community has a population of over 150 people and most of Ruby’s residents are Koyukon Athabascan. Ruby has a long history of promoting local efficiency and clean energy in an effort to become more sustainable. Between 2007-2010, the community hosted Alaska’s first demonstration of an in-river hydrokinetic test project, sponsored by the Yukon River Inter-Tribal Watershed Council. In 2011, a 5kW solar photo-voltaic (PV) array was installed by the Interior Regional Housing Authority. In 2012, the community had a new power plant constructed by the Alaska Energy Authority that supplies waste heat to the washeteria, clinic and public safety garage, saving the community more than 4,000 gallons of heating fuel per year. The clinic, constructed by the Tanana Chiefs Conference, is one of the most energy efficient buildings in the interior and utilizes new building efficiency standards that were passed by the tribes. It has a 5kW solar PV array that provides energy into the local electric grid and offsets approximately 20% of the annual energy use. Building on this legacy, the City of Ruby entered into Department of Energy’s (DOE’s) Remote Alaska Communities Energy Efficiency Competition (RACEE) in 2016, pledging to reduce per-capita energy use 15% by 2020. During the second phase of the competition, 13 communities including Ruby were provided funding for tailored technical assistance to measure energy use and create energy efficiency plans.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Geological Thermal Energy Storage Using Solar Thermal and Carnot Batteries: Techno-Economic Analysis

Energy storage is increasingly necessary as variable renewable energy technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological thermal energy storage (GeoTES) is proposed as a solution for long-term energy storage. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. In this article, we describe a techno-economic model that has been developed to evaluate GeoTES systems. The models are developed by combining the output of specialist models, which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models are developed so that the performance can be evaluated at each hour of the year. GeoTES can be charged with two different energy sources: (1) concentrating solar thermal and (2) renewable electricity using heat pumps (henceforth known as a "Carnot Battery"). The stored thermal energy can be used to generate electricity and, uniquely, also directly produce heat that can be used by industrial processes. Furthermore, Carnot Battery GeoTES can also be used to form a cold storage reservoir. Preliminary results that quantify the technical and economic performance of these two GeoTES systems are presented.

carnot battery↗

Overcoming significant challenges in extracting off-stoichiometric thermodynamics using the compound energy formalism through complementary use of experimental and first principles data: A case study of Ba 1-x Sr x FeO 3-δ

The compound energy formalism (CEF) is a powerful framework to describe the thermodynamics of metal oxides as a function of off-stoichiometry, temperature, and composition. The thermodynamic properties are crucial materials design attributes in metal oxide-based oxygen-exchange chemical processes. Despite the richness of information an accurate CEF model provides, a method to determine a unique and accurate fit for oxygen exchange materials remains elusive. This contribution details a method for fitting the CEF model that overcomes the current fitting challenges through three innovations: 1) the combination of density functional theory calculations with experimental data decorrelates excess terms and delineates the enthalpic/entropic contributions to the Gibbs free energy; 2) a systematic determination of the important CEF model terms, removing thermodynamic predetermining human intervention; 3) a self-consistent solution of the starting oxygen offstoichiometry (δ 0 ) of thermogravimetric measurements. Thus, our method enables the reliable extraction of off-stoichiometric metal oxide thermodynamic properties and facilitates rapid materials compositional screening, and reliable process design of systems dependent on off-stoichiometric redox-active metal oxides. We apply this method to a Ba x Sr 1-x FeO 3-δ test case. We find by systematically examining the performance of the CEF model fit with and without each innovation that all three innovations are necessary for an accurate fit. We determined that reduction enthalpy is higher and more sensitive to off-stoichiometry when the Sr fraction is large (139.5 and 185.3 kJ/mol O 2 for SrFeO 3 at δ = 0 and δ = 0.5, respectively vs. nearly constant 83 kJ/mol O 2 for BaFeO 3 ). However, the reduction entropy is mostly insensitive to Sr fraction, but highly dependent on δ suggesting larger contributions in the non-configurational entropy parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal energy storage using large hollow steel ingots

High temperature thermal energy storage (to 500 C = 930 F) using hollow steel ingots is investigated. Preliminary studies indicate that the system should be reliable, be characterized by low operation and maintenance costs, and be associated with low development risk. The estimated installed system energy unit storage cost is $13.50/kWh-t.

Turner, R. H.↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

Enabling Principles for Dual Participation by Energy Storage as a Transmission and Market Asset

Because the electric transmission system is sized to meet the highest levels of customer demand, much of its designed capacity goes unused during average operating conditions. As a uniquely flexible and scalable asset capable of providing multiple grid services, energy storage can be deployed to support the transmission system and then also provide services to energy markets when not needed for transmission. This paper reviews the technical barriers in transmission planning practices and energy market design that prevent the realization of dual-use energy storage projects that provide both regulated transmission and competitive market services. Current practices create barriers against the identification of energy storage in the transmission planning process and against the participation of a regulated transmission asset in competitive energy markets. A review of regional transmission plans identifies best practices for including energy storage in the planning process by directing planners to proactively identify such projects or by providing clear mechanisms for stakeholders to propose them. Creating a market participation model for dual-use energy storage assets requires establishing when an asset will be allowed to participate in the market, how it will participate in the market, and where it will recover its costs. In answering these questions, key principles must be satisfied, such as prioritizing reliability, incrementally building on existing market design, and balancing competing objectives. Several policy options exist for satisfying those principles, giving grid operators and stakeholders significant flexibility in developing a dual-use participation model in accordance with regional policies and conditions. By objectively framing the issue and identifying policy options, this paper may inform subsequent proceedings on dual-use energy storage and be a resource to regional market operators, utilities, developers, regulators, policymakers, and other stakeholders as they collectively work on this complex issue.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary survey of propulsion using chemical energy stored in the upper atmosphere

Ram-jet cycles that use the chemical energy of dissociated oxygen for propulsion in the ionosphere are presented. After a review of the properties and compositions of the upper atmosphere, the external drag, recombination kinetics, and aerodynamic-heating problems of an orbiting ram jet are analyzed. The study indicates that the recombination ram jet might be useful for sustaining a satellite at an altitude of about 60 miles. Atmospheric composition and recombination-rate coefficients were too uncertain for more definite conclusions. The ram jet is a marginal device even in the optimistic view.

Baldwin, Lionel V↗

ResStock Dataset 2024.1 Documentation

Public ResStock datasets provide credible, relevant, and accessible information on energy use and related non-energy metrics to a variety of stakeholders in the residential buildings space. The current public datasets include baseline building characteristics, timeseries (15-minute) energy consumption, and timeseries carbon emissions for the baseline (existing) U.S. housing stock and the U.S. housing stock with 10 "what-if" energy measure packages applied. This report documents a new public ResStock dataset to complement and build upon the existing public datasets. This dataset is specifically intended to be a resource for state and local decision-makers considering options for energy retrofits for their housing stock to reduce carbon emissions, energy use, and/or utility bills. These data consist of housing stock characteristics and modeled full-year energy consumption, carbon emission, energy bill, and energy burden data for the baseline U.S. housing stock as well as the U.S. housing stock with 260 "what-if" energy measure packages applied. These measure packages include measures related to the building envelope, appliances, pools and spas, lighting, water heating, and HVAC (including efficiency improvements and fuel switching with equipment at a range of performance levels) in a variety of combinations. This report provides methodology information on the generation of this dataset and serves as a key part of the dataset's public documentation.

buildings↗

Geological Thermal Energy Storage Using Solar Thermal and Carnot Batteries: Techno-Economic Analysis: Preprint

Energy storage is increasingly necessary as Variable Renewable Energy (VRE) technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological Thermal energy storage (GeoTES) is proposed as a solution for long-term energy storage. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. In this article, we describe a techno-economic model that has been developed to evaluate GeoTES systems. The models are developed by combining the output of specialist models which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models are developed so that the performance can be evaluated at each hour of the year. GeoTES can be charged with two different energy sources: (1) concentrating solar thermal and (2) renewable electricity using heat pumps (henceforth known as a "Carnot Battery"). The stored thermal energy can be used to generate electricity and - uniquely - also directly produce heat that can be used by industrial processes. Furthermore, Carnot-Battery-GeoTES can also be used to form a cold storage reservoir. Preliminary results that quantify the technical and economic performance of these two GeoTES systems are presented.

carnot battery↗

Dehumidification energy storage using a stratified liquid desiccant tank

Liquid desiccants can play an important role in reducing dehumidification energy requirements in the built environment. Because they are in a liquid state, the desiccant can be easily stored and then used to dehumidify buildings during peak energy consumption periods. By maintaining stratification between concentrated and diluted desiccant solutions, a single tank can be used to store liquid desiccant for energy storage purposes. Using a stratified tank instead of separate tanks for dilute and concentrated solutions will reduce storage costs and increase energy storage densities for liquid desiccant systems. This paper describes the experimental validation and one-dimensional modeling of a stratified liquid desiccant tank. The stratified tank prototype developed achieved 80 % of the theoretical energy storage density based on an imposed desiccant concentration change. Here, the stratified tank model was able to reasonably reproduce the experimental results. Using this model, the impact of varying operational conditions on the energy density of the stratified liquid desiccant energy storage was evaluated. Depending on the operating conditions, stratified liquid desiccant energy storage using aqueous LiCl up to 40 wt% can achieve energy storage densities in excess of 330 kWh/m 3 .

25 ENERGY STORAGE↗

Consumer Guide to Energy-Efficient Lighting

Learn how to reduce energy use from lighting and choose energy efficient light bulbs, as well as why it pays to make energy efficient lighting choices. This fact sheet from Energy Saver includes information on the history of lighting, today's LED lights and how to choose the best ones for your needs, and how to reduce your energy use from lighting.

lighting, light bulbs, LED lights, lumens, dayligh↗

Surrogate model evaluation and building energy benchmarking for commercial buildings

Building energy consumption benchmarking involves challenges associated with various energy patterns for different building types; heating, ventilating, and air-conditioning (HVAC) system types; and climates. Given significant variation in energy use patterns, accurate prediction of long-term energy use using surrogate models remains challenging. Multiple linear regression (MLR) is commonly used for building energy benchmarking because of its simple structure; however, it lacks accuracy compared to other black-box models. Although many studies have compared surrogate models and offer guidance on model selection based on metrics, they do not provide detailed analysis on improving the surrogate model accuracy. In this paper, we implement a surrogate model using polynomial ridge regression (i.e., MLR with interaction terms combined with ridge regularization) for small office and retail strip mall buildings across six HVAC system types and all climate zones, for electricity and natural gas in baseline and proposed scenarios. A simulation workflow is developed using OpenStudio TM /EnergyPlus TM to generate simulation data using measures over a wide range of efficiency inputs. Enhancements based on statistical insights are used for improving the model accuracy using filters, input transformations, and change points. Surrogate models achieved average coefficient of variation of the root mean squared error (CVRMSE) values of 2.17, 1.06, 2.05, and 3.26 for proposed electricity, proposed natural gas, baseline electricity, and baseline natural gas, respectively, with enhancements reducing CVRMSE by an average of 14.9% across all combinations. We provide model interpretation via Shapley additive explanations to determine which input variables most influence energy consumption and provide supportive arguments for enhancements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lighting and visual comfort performance of commercially available tubular daylight devices

Tubular daylight devices (TDDs) require a much smaller roof opening than conventional skylights and, because of their highly reflective tube, they can deliver daylight farther away from the building envelope. This can provide lighting energy savings, increasing resilience in new and existing buildings. Different types and configurations are available amongst commercially available TDDs, including domes/diffusers with varying optical properties and the diameter of the TDD. This paper presents a comprehensive experimental evaluation of the lighting and visual comfort performance of multiple configurations of commercially available TDDs, varying dome type (prismatic and clear), diffuser type (Fresnel and prismatic), and diameter (53 and 35 cm), under a range of environmental conditions (different times of day/year, sky cover). Based on illuminance measurements, estimated lighting energy use is also presented. Results indicate that, for clear sky, light levels increase and energy use decreases with solar altitude (e.g., 16 Wh/m 2 daily energy use intensity on a high maximum daily solar altitude (MDSA) day and 34 Wh/m 2 on a low MDSA day) and TDD diameter (e.g., 34 Wh/m 2 and 69 Wh/m 2 for 53 cm and 35 cm TDDs, respectively, for low MDSA). The daily illuminance profile is more rounded for prismatic domes and has higher peaks for clear domes; this translates into a somewhat higher average daily useful daylight illuminance (DUDI) for prismatic domes (86 %) when compared to clear domes (80 %). No clear impact of diffuser type was apparent. In conclusion, measurements indicated no discomfort glare for any of the conditions tested.

14 SOLAR ENERGY↗