Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical signals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

The Polar Plasma Wave Instrument

The Plasma Wave Instrument on the Polar spacecraft is designed to provide measurements of plasma waves in the Earth's polar regions over the frequency range from 0.1 Hz to 800 kHz. Three orthogonal electric dipole antennas are used to detect electric fields, two in the spin plane and one aligned along the spacecraft spin axis. A magnetic loop antenna and a triaxial magnetic search coil antenna are used to detect magnetic fields. Signals from these antennas are processed by five receiver systems: a wideband receiver, a high-frequency waveform receiver, a low-frequency waveform receiver, two multichannel analyzers; and a pair of sweep frequency receivers. Compared to previous plasma wave instruments, the Polar plasma wave instrument has several new capabilities. These include (1) an expanded frequency range to improve coverage of both low- and high-frequency wave phenomena, (2) the ability to simultaneously capture signals from six orthogonal electric and magnetic field sensors, and (3) a digital wideband receiver with up to 8-bit resolution and sample rates as high as 249k samples s(exp -1).

Gurnett, D. A.↗

Signal processing in ultrasound

Signal is the term used to denote the characteristic in the time or frequency domain of the probing energy of the system. Processing of this signal in diagnostic ultrasound occurs as the signal travels through the ultrasonic and electrical sections of the apparatus. The paper discusses current signal processing methods, postreception processing, display devices, real-time imaging, and quantitative measurements in noninvasive cardiology. The possibility of using deconvolution in a single transducer system is examined, and some future developments using digital techniques are outlined.

Le Croissette, D. H.↗

Electrostatic charge buildup and electrostatic discharge monitoring system and method

A system for monitoring electrostatic charge buildup and electrostatic discharge (ESD) remotely comprises a plurality of electrostatic charge measurement units and a data acquisition device. Each electrostatic charge measurement unit includes a primary charge plate, a static sensor device, a secondary charge plate, and a shielded cable. The primary charge plate is positioned proximal to an object. The static sensor device includes an input sensor at which an electric voltage is measured and outputs an electronic signal whose level varies according to the measured electric voltage. The secondary charge plate is positioned in proximity to the input sensor of the static sensor device. The shielded cable includes an inner conductor electrically connected to the primary charge plate and the secondary charge plate and an outer conductor electrically connected to electrical ground. The data acquisition device receives the electronic signal from the static sensor device of each electrostatic charge measurement unit.

Schantz, Eric T.↗

Coherent homodyne detection for amplified cross-beam electric-field induced second harmonic

The electric-field induced second harmonic (E-FISH) signal sensing is commonly used as a nonlinear optical technique to probe electric fields inside a plasma region. Cross-beam E-FISH is being investigated to improve spatial resolution by defining the interaction volume via a controlled geometry of two overlapping noncolinear optical beams. This drastic reduction in interaction length of the electric field and laser region results in a significant signal reduction. Here, to overcome this signal reduction, we introduce coherent amplification of the cross-beam E-FISH signal by mixing the low E-FISH signal with a phase-locked bright local oscillator. We demonstrate enhancement of the signal. By introducing a local oscillator we can now derive the polarity of the measured electric field through the phase of the homodyne signal. To illustrate the technique, we, for the first time, to the best of our knowledge, measure the magnitude and the direction of the electric field in a cold atmospheric pressure plasma jet, which dynamically follows the profile of the applied bias current.

42 ENGINEERING↗

Mathematical Tools for the Analysis of Periodic and Aperiodic Grid Signals

Numerous sensing techniques and instrumentation are used in determining the state of the electric grid. Coupled with such measurements are the methods and analysis tools used. The parameters of interest result in both periodic and aperiodic signals. An examination of appropriate analysis tools is presented

97 MATHEMATICS AND COMPUTING↗

Nonlinear optical response of metal-barrier-metal junctions

The optical response of metal-barrier-metal (MBM) junctions is discussed, with emphasis on the nonlinearity of response associated with reversal of polarity as optical intensity is increased. This nonlinear behavior can be used to measure correlation functions of optical pulses or to generate ultrashort electrical pulses. Expressions for the current flowing through the insulating barrier (junction), and for the rectification current, are given. Pulse signal and polarity of the electrical pulse evolves as the junction bias is varied about the null-signal bias. The apparatus used to obtain rectification pulse signals is described; the calculated evolution of the rectified pulse shape is found to correspond to that of pulse signals obtained experimentally. The generation of pulses six orders of magnitude smaller than a previously-obtained instrument-limited 1.6 nanosecond pulse has been observed.

Fan, B.↗

Solar Eruptive Events

It s long been known that the Sun plays host to the most energetic explosions in the solar system. But key insights into the forms that energy takes have only recently become available. Solar flares have been phenomena of both academic and practical interest since their discovery in 1859. From the academic point of view, they are the nearest events for studying the explosive release of energy in astrophysical magnetized plasmas. From the practical point of view, they disrupt communication channels on Earth, from telegraph communications in 1859 to radio and television signals today. Flares also wreak havoc on the electrical power grid, satellite operations, and GPS signals, and energetic charged particles and radiation are dangerous to passengers on high-altitude polar flights and to astronauts. Flares are not the only explosive phenomena on the Sun. More difficult to observe but equally energetic are the large coronal mass ejections (CMEs), the ejection of up to ten billion tons of magnetized plasma into the solar wind at speeds that can exceed 1000 km/s. CMEs are primarily observed from the side, with coronagraphs that block out the bright disk of the Sun and lower solar atmosphere so that light scattered from the ejected mass can be seen. Major geomagnetic storms are now known to arise from the interaction of CMEs with Earth's magnetosphere. Solar flares are observed without CMEs, and CMEs are observed without flares. The two phenomena often occur together, however, and almost always do in the case of large flares and fast CMEs. The term solar eruptive event refers to the combination of a flare and a CME. Solar eruptive events generate a lot of heat: They can heat plasma to temperatures as high at 50 million Kelvin, producing radiation across the electromagnetic spectrum. But that s not all. A fascinating aspect of solar eruptive events is the acceleration of electrons and ions to suprathermal often relativistic energies. The accelerated particles are primarily observed through their emissions in the higher energy x-ray, gamma-ray, and rf regimes. The radio and x-ray emissions are both from mildly relativistic electrons with energies of tens of keV and above. Gamma-ray line emission comes indirectly from accelerated protons and heavier ions with MeV and higher energies. The difficulty in collecting spatially and spectrally resolved x-ray and gamma-ray data has long been a barrier to learning about the accelerated particles. Considerable progress has been made in the last decade in understanding the relationship between the flare, the CME, energy release, and particle acceleration. But many new questions have also arisen. In this article, I describe those new insights and our evolving understanding of solar eruptive events.

Holman, Gordon D.↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

Electrical Detection of Single-Domain Néel Vector Reorientation across the Spin–Flop Transition in Cr 2 O 3 Crystals

Electrical transport measurements in heterostructures of antiferromagnetic Cr 2 O 3 bulk crystals and a thin Pt layer exhibit sharp responses as the Néel vector of Cr 2 O 3 undergoes the spin−flop transition. This abrupt change can arise from several distinct mechanisms including magnetostriction, proximity-induced anomalous Hall, spin Hall anomalous Hall, and spin Hall planar Hall effects. While large Pt devices sensing multiple up/ down domains can produce indistinguishable Hall signal jumps due to different initial Néel vector orientations, smaller Pt devices that sense single domains isolate the proximity-induced Hall signals. This allows direct electrical detection of Néel vector reorientation across the spin−flop transition in single-domain regions. Furthermore, the single-domain state can be prepared by magnetic field cooling or magnetoelectric cooling. We demonstrate a method to control and characterize the three-dimensional orientation of single-domain Néel vectors by exploiting Hall measurements and cooling techniques, crucial for future antiferromagnetic spintronic applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using Piezoelectric Devices to Transmit Power through Walls

A method denoted wireless acoustic-electric feed-through (WAEF) has been conceived for transmitting power and/or data signals through walls or other solid objects made of a variety of elastic materials that could be electrically conductive or nonconductive. WAEF would make it unnecessary to use wires, optical fibers, tubes, or other discrete wall-penetrating signal-transmitting components, thereby eliminating the potential for structural weakening or leakage at such penetrations. Avoidance of such penetrations could be essential in some applications in which maintenance of pressure, vacuum, or chemical or biological isolation is required. In a basic WAEF setup, a transmitting piezoelectric transducer on one side of a wall would be driven at resonance to excite ultrasonic vibrations in the wall. A receiving piezoelectric transducer on the opposite side of the wall would convert the vibrations back to an ultrasonic AC electric signal, which would then be detected and otherwise processed in a manner that would depend on the modulation (if any) applied to the signal and whether the signal was used to transmit power, data, or both. An electromechanical-network model has been derived as a computationally efficient means of analyzing and designing a WAEF system. This model is a variant of a prior model, known in the piezoelectric-transducer art as Mason's equivalent-circuit model, in which the electrical and mechanical dynamics, including electromechanical couplings, are expressed as electrical circuit elements that can include inductors, capacitors, and lumped-parameter complex impedances. The real parts of the complex impedances are used to account for dielectric, mechanical, and coupling losses in all components (including all piezoelectric-transducer, wall, and intermediate material layers). In an application to a three-layer piezoelectric structure, this model was shown to yield the same results as do solutions of the wave equations of piezoelectricity and acoustic propagation in their full complexity.

Sherrit, Stewart↗

Microfabricated Ion Traps on Sapphire for Larger Trap Areas and Higher Qubit Count

Surface ion traps are a promising platform for quantum computing due to their potential to store large numbers of ions that can be addressed by electrical and optical control signals in order to implement quantum algorithms. Increasing the power of the quantum computer requires increasing the number of ions, but this poses a significant challenge in that it leads to a non-linear increase in on-chip power dissipation. The primary contributor to this power scaling in current devices is the capacitance between the radio frequency (RF) electrode and the metal plane that shields the silicon substrate from the RF signals applied to it. Silicon has traditionally been chosen for the substrate material for compatibility with the processing required for multi-metal-level traps. In this work, we address these capacitance and fabrication challenges by replacing the commonly used silicon substrate with an insulating sapphire substrate to fabricate a multi-metal-level ion trap, while still employing common semiconductor manufacturing techniques. This change in substrate allows the design to remove the metal shielding from the device design, reducing the capacitance of the RF electrode. The electrical characteristics of these traps were measured, specifically trap impedance, capacitance, and voltage breakdown, and compared to nearly identical silicon trap devices. Finally, we used laser cutting techniques to shape a sapphire wafer into bowtie shapes matching silicon traps previously fabricated at Sandia National Labs to explore solutions for integrating sapphire substrates into non-rectangular ion trap designs.

97 MATHEMATICS AND COMPUTING↗

Isolated Fast High-Voltage Switching Circuit

Electrically isolated switching circuit supplies pulses at potentials up to 6.5 kV and currents up to 6.5 A, lasting as long as few microseconds. Turn-on time about 40 ns; turn-off time about 3 microseconds. Electrically isolated from control circuitry by means of fiber-optic signal coupling and isolated power supply. Electrical isolation protects both technician and equipment. This and similar circuits useful in such industrial and scientific applications as high-voltage, high-frequency test equipment; electrostatic-discharge test equipment; plasma-laboratory instrumentation; spark chambers; and electromagnetic-interference test equipment.

Rizzi, Anthony↗

Search for continuous gravitational wave signals from luminous dark photon superradiance clouds with LVK O3 observations

Superradiance clouds of kinetically mixed dark photons around spinning black holes can produce observable multimessenger electromagnetic and gravitational wave signals. The cloud generates electric fields of up to a teravolt-per-meter, which leads to a cascade production of charged particles, yielding a turbulent quasiequilibrium plasma around the black hole, and resulting in electromagnetic fluxes ranging from supernova to pulsar-like luminosities. For stellar mass black holes, such systems resemble millisecond pulsars and are expected to emit pulsating radio waves and continuous gravitational waves (CWs) within the LIGO-Virgo-KAGRA (LVK) sensitivity band. We select 44 sources with approximately coincident frequencies or positive frequency drifts from existing pulsar catalogs as potential candidates of long-lasting superradiance clouds around old Galactic black holes. For a subset of 34 sources that are well measured and have not been previously targeted, we perform the first search for CW emission in LVK data from the third observing run. We find no evidence of a CW signal and place 95% confidence level upper limits on the emitted strain amplitude. We interpret these results, together with limits from previous searches, in terms of the underlying dark photon theory by performing an analysis of the expected signals from superradiance clouds from Galactic black holes. Finally, we find that, even for moderately spinning black holes, the absence of an observed CW signal disfavors a discrete set of dark photon masses between about 10 −13 and 10 −12 eV/c 2 and kinetic mixing couplings in the range of 10 −9 –10 −7 , subject to assumptions about the properties of the black hole population and the cloud’s electromagnetic emission.

astronomical black holes↗

Electrical alternans during rest and exercise as predictors of vulnerability to ventricular arrhythmias

This investigation was performed to evaluate the feasibility of detecting repolarization alternans with the heart rate elevated with a bicycle exercise protocol. Sensitive spectral signal-processing techniques are able to detect beat-to-beat alternation of the amplitude of the T wave, which is not visible on standard electrocardiogram. Previous animal and human investigations using atrial or ventricular pacing have demonstrated that T-wave alternans is a marker of vulnerability to ventricular arrhythmias. Using a spectral analysis technique incorporating noise reduction signal-processing software, we evaluated electrical alternans at rest and with the heart rate elevated during a bicycle exercise protocol. In this study we defined optimal criteria for electrical alternans to separate patients from those without inducible arrhythmias. Alternans and signal-averaged electrocardiographic results were compared with the results of vulnerability to ventricular arrhythmias as defined by induction of sustained ventricular tachycardia or fibrillation at electrophysiologic evaluation. In 27 patients alternans recorded at rest and with exercise had a sensitivity of 89%, specificity of 75%, and overall clinical accuracy of 80% (p <0.003). In this patient population the signal-averaged electrocardiogram was not a significant predictor of arrhythmia vulnerability. This is the first study to report that repolarization alternans can be detected with heart rate elevated with a bicycle exercise protocol. Alternans measured using this technique is an accurate predictor of arrhythmia inducibility.

Clinical Trial↗

Apparatus for and method of eliminating single event upsets in combinational logic

An apparatus for and method of eliminating single event upsets (or SEU) in combinational logic are used to prevent error propagation as a result of cosmic particle strikes to the combinational logic. The apparatus preferably includes a combinational logic block electrically coupled to a delay element, a latch and an output buffer. In operation, a signal from the combinational logic is electrically coupled to a first input of the latch. In addition, the signal is routed through the delay element to produce a delayed signal. The delayed signal is routed to a second input of the latch. The latch used in the apparatus for preventing SEU preferably includes latch outputs and a feature that the latch outputs will not change state unless both latch inputs are correct. For example, the latch outputs may not change state unless both latch inputs have the same logical state. When a cosmic particle strikes the combinational logic, a transient disturbance with a predetermined length may appear in the signal. However, a function of the delay element is to preferably provide a time delay greater than the length of the transient disturbance. Therefore, the transient disturbance will not reach both latch inputs simultaneously. As a result, the latch outputs will not permanently change state in error due to the transient disturbance. In addition, the output buffer preferably combines the latch outputs in such a way that the correct state is preserved at all times. Thus, combinational logic with protection from SEU is provided.

Gambles, Jody W.↗

Electrical conductivity of Sn at high pressure and temperature

To date, temperature and conductivity have many outstanding implications in extreme environments but are yet to be fully understood under high pressure and temperature dynamic conditions. Here, we introduce an approach to provide high quality electrical conductivity results under dynamic loading conditions. Emphasis is given to address the skin depth effect's influence in a dynamic loading experiment by using thin films. The thin film samples in this study were at least 100 times thinner than previous samples in dynamic electrical conductivity experiments, increasing the current density to its full potential across the sample's entire cross section. Consideration of the skin depth accounts for at minimum a 4× scaling factor to the final electrical conductivity result that has been neglected in previous dynamic electrical conductivity studies. We also obtained improved signal-to-noise ratio with custom diagnostics optimized for better electrical impedance matching. Furthermore, these considerations were applied to Sn to assess electrical conductivity at elevated pressure and temperature. The high signal-to-noise ratio with reduced skin depth influence results in Sn allowing observation of the conductivity changes related to solid-to-solid and solid-to-liquid phase transitions. Additionally, we calculate the Sn thermal conductivity using the Wiedemann-Franz law for our experiments and compare against thermal transport dependent temperature measurements from previous work.

36 MATERIALS SCIENCE↗

An assessment of controlled source EM for monitoring subsurface CO 2 injection at the wyoming carbonSAFE geologic carbon storage site

Here we evaluate if electromagnetic (EM) geophysical methods for monitoring geologic carbon storage (GCS) efforts at the Wyoming CarbonSAFE project adjacent to the Dry Fork Station power plant near Gillette, Wyoming. This first involved acquiring both electric and magnetic fields at eleven different locations ranging in distance from immediately adjacent to 4 km from the plant. Passive EM measurements were made to provide spectral EM noise measurements generated by electricity production at the plant and to determine if useful magnetotelluric (MT) data can be successfully collected in the region. The processed data indicate that useful MT data can be collected as long as the site is located more than 2km away from the power plant as well as active roads and rail lines. Controlled source EM data were collected using three different source configurations, two of which connected to steel casings used to complete the injection wells. Comparing the EM noise measurements to the CSEM data show measurable electric and magnetic field signals at all sites. Next a series of three-dimensional (3D) numerical models were built that simulate resistivity changes caused by the proposed CO2 injection at depths ranging from 2.4 to 3.0km. These models were used to simulate various EM measurement configurations. The modeling shows that casing-source CSEM monitoring can provide sensitivity to the injected CO 2 if source electrodes are connected to the bottom of one or both of the injection wells.

58 GEOSCIENCES↗

Multifunctional Silk Fibroin Hydrogels with Strong Adhesion for Tissue Sealing and Wearable Electronic Sensors

Multifunctional hydrogels with excellent adhesion, biodegradability, and conductivity are essential for overcoming the obstacles of postoperative secondary injury, flexible sensing instability, and so on. Herein, we develop a multifunctional silk fibroin (SF) hydrogel modified with poly(acrylic acid). Owing to the stable chemical cross-linking network and the abundant carboxylic acid groups of the SF network, the SF hydrogel exhibits a high tensile strength of 74.34 kPa due to sufficient cohesion and interfacial interactions. Additionally, the tensile strain reaches a maximum of 414.6%, the compressive strength is 0.9 MPa, and the shear adhesive strength for pig skin tissues is as high as 64 kPa. Compared with most hydrogels, our multifunctional SF hydrogel with a low swelling ratio provides excellent adhesion, biodegradation, and conductivity, which shows advantages in terms of invasive tissue sealing. Furthermore, the use of self-adhesive SF hydrogels as conductive hydrogels in flexible sensors also benefits the collection of physiological electricity and human motion signals in the field of wearable and implantable electronic devices.

adhesive↗