Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Power efficiency improvements with the radio frequency H{sup −} ion source

CW 13.56 MHz radio frequency-driven H{sup −} ion source is under development at the University of Jyväskylä for replacing an existing filament-driven ion source at the MCC30/15 cyclotron. Previously, production of 1 mA H{sup −} beam, which is the target intensity of the ion source, has been reported at 3 kW of RF power. The original ion source front plate with an adjustable electromagnet based filter field has been replaced with a new front plate with permanent magnet filter field. The new structure is more open and enables a higher flux of ro-vibrationally excited molecules towards the plasma electrode and provides a better control of the potential near the extraction due to a stronger separation of the main plasma from the plasma electrode. While the original system provided better control over the e{sup −}/H{sup −} ratio, the new configuration has led to a higher production efficiency of 1 mA H{sup −} at 1.75 kW RF power. The latest results and upgrade plans are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compton Imaging Capabilities of AGATA for Background Rejection

In this work we present the results of the test performed at the Laboratori Nazionali di Legnaro (LNL) aiming to characterize the capabilities of the AGATA detectors to discriminate between different gamma source locations. AGATA detectors are position sensitive to the interaction points through Pulse Shape Analysis allowing location of the gamma sources by using Compton imaging algorithm. The final goal is to increase the array sensitivity reducing the background originated outside the AGATA target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical study of plasma generation process and internal antenna heat loadings in J-PARC RF negative ion source

A numerical model of plasma transport and electromagnetic field in the J-PARC (Japan Proton Accelerator Research Complex) radio frequency ion source has been developed to understand the relation between antenna coil heat loadings and plasma production/transport processes. From the calculation, the local plasma density increase is observed in the region close to the antenna coil. Electrons are magnetized by the magnetic field line with absolute magnetic flux density 30–120 Gauss which leads to high local ionization rate. The results suggest that modification of magnetic configuration can be made to reduce plasma heat flux onto the antenna.

43 PARTICLE ACCELERATORS↗

4th TDAMM Workshop White Paper

Time-Domain and Multi-Messenger Astrophysics (TDAMM) is entering a fundamentally new phase characterized by an unprecedented increase in the rate and diversity of astrophysical transient detections. The community is transitioning from a discovery-limited to a follow-up-limited era, driven by major investments across electromagnetic, gravitational-wave, and neutrino observatories. Upcoming facilities such as the Vera C. Rubin Observatory, the Nancy Grace Roman Space Telescope, and wide-field survey instruments will produce a deluge of time-domain alerts, reaching millions of events per night. Simultaneously, upgrades to the gravitational-wave network (LVK O5 and beyond) and neutrino observatories (IceCube Gen2) will significantly increase the detection rates of non-electromagnetic messengers. New high-energy missions and expansions of the InterPlanetary Network (IPN) will further enhance discovery capabilities across the gamma-ray and X-ray regimes. This convergence of capabilities represents a transformative opportunity: for the first time, the community will routinely detect rare and high-impact events across multiple messengers. However, the scientific return from these discoveries will depend critically on the ability to rapidly identify, prioritize, and coordinate follow-up observations across a heterogeneous and globally distributed set of facilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Construction and performance of the barrel electromagnetic calorimeter for the Gluex experiment

The barrel calorimeter is part of the new spectrometer installed in Hall D at Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013, commissioned in 2014 and has been operating routinely since early 2015. The detector configuration, associated Monte Carlo simulations, calibration and operational performance are described in this paper. The calorimeter records the time and energy deposited by charged and neutral particles created by a multi-GeV photon beam. It is constructed as a lead and scintillating-fiber calorimeter and read out with 3840 large-area silicon photomultiplier arrays. Particles impinge on the detector over a wide range of angles, from normal incidence at 90 degrees down to 11.5 degrees, which defines a geometry that is fairly unique among calorimeters. The response of the calorimeter has been measured during a running experiment and performs as expected for electromagnetic showers below 2.5 GeV. Finally, we characterize the performance of the BCAL using the energy resolution integrated over typical angular distributions for π 0 and η production of σ E / E = 5 . 2 % / E ( GeV ) ⊕ 3 . 6 % and a timing resolution of σ = 150 ps at 1 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning tunneling microscope design with a confocal small field permanent magnet.

The field of ultra-sensitive measurements with scanning probes requires the design and construction of novel instruments. For example, the combination of radio frequency detection and scanning probe can be exploited to measure thermal properties and mechanical resonances at a very low scale. Very recent results by Komeda and Manassen (2008 Appl. Phys. Lett. 92 212506) on the detection of spin noise with the scanning tunneling microscopy (STM) have further expanded previous results reported by one of the authors of this manuscript (Messina et al 2007 J. Appl. Phys. 101 053916). In a previous publication, one of the authors used a new STM instrument (Messina et al J. Appl. Phys. 2007 101 053916 and Mannini et al 2007 Inorg. Chim. Acta 360 3837-42) to obtain the detection of electron spin noise (ESN) from individual paramagnetic adsorbates. The magnetic field homogeneity at the STM tip-sample region was limited. Furthermore, vacuum operation of the STM microscope was limited by the heat dissipation at the electromagnet and the radio frequency (RF) recovery electronics. We report here on a new STM head that incorporates a specially designed permanent magnet and in-built RF amplification system. The magnet provides both a better field homogeneity and freedom to operate the instrument in vacuum. The STM microscope is vacuum compatible, and vertical stability has been improved over the previous design (Messina et al 2007 J. Appl. Phys. 101 053916), despite the presence of a heat dissipative RF amplifier in the close vicinity of the STM tip.

47 OTHER INSTRUMENTATION↗

Flight test techniques for validating simulated nuclear electromagnetic pulse aircraft responses

An attempt has been made to determine the effects of nuclear EM pulses (NEMPs) on aircraft systems, using a highly instrumented NASA F-106B to document the simulated NEMP environment at the Kirtland Air Force Base's Vertically Polarized Dipole test facility. Several test positions were selected so that aircraft orientation relative to the test facility would be the same in flight as when on the stationary dielectric stand, in order to validate the dielectric stand's use in flight configuration simulations. Attention is given to the flight test portions of the documentation program.

Winebarger, R. M.↗

Electron transport and charge induction in cadmium zinc telluride detectors with space charge build up under intense x-ray irradiation

Under intense x-ray irradiation, wide band gap semiconductor radiation detectors fabricated from crystals with low hole transport properties develop a steady-state space charge distribution that results from a dynamic equilibrium between charge carrier dynamics and the incident photon field. At a high enough x-ray flux, this space charge can collapse the electric field within the detector, resulting in the paralyzation of photon counting (i.e., high-flux polarization). However, well before polarization causes a catastrophic device failure, there can be enough space charge present to significantly modify the electric field. A modified field affects the electron transport and, therefore, signal generation within the sensor, which can ultimately degrade the performance of high-rate photon counting electronics. In this study, we analytically solve the fundamental equation of charge conservation to derive the modified electron transport in the presence of an exponential space charge distribution that results from the incident x-rays. We use these space-time solutions to calculate and study the time dependence of the resulting charge-induced signals. The predicted induced signals are compared throughout with numerical solutions of the full charge transport equation. In addition, we present analogous closed-form signals for a uniform distribution relevant to a broader class of {gamma}-ray applications. Finally, we use these solutions to derive a two-parameter family of modified Hecht curves that naturally predict a voltage offset that appears due to the space charge.

36 MATERIALS SCIENCE↗

Port Impedance Measurement and Current Injection Response Analysis for PLCs

Programmable Logic Controllers (PLCs) are used to control devices throughout the power system since they have fast control capabilities and can utilize multiple types of communication interfaces. Therefore, studying and mitigating their vulnerabilities to electromagnetic pulse is important for the reliability of PLC operations. Here, in this paper, an effective impedance measurement scheme is proposed and demonstrated for three PLCs to estimate their susceptibility to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then different parameters of the impedance measurement setup are explored. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulsed Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of the PLC.

42 ENGINEERING↗

Electromagnetic diffraction efficiencies for plane reflection diffraction gratings

The theory and computer programs, based on electromagnetic theory, for the analysis and design of echelle gratings were developed. The gratings are designed for instruments that operate in the ultraviolet portion of the spectrum. The theory was developed so that the resulting computer programs will be able to analyze deep (up to 30 wavelengths) gratings by including as many as 100 real or homogeneous diffraction orders. The program calculates the complex amplitude coefficient for each of the diffracted orders. A check on the numerical method used to solve the integral equations is provided by a conservation of energy calculation.

Marathay, A. S.↗

Basic research in meteorology and atmospheric physics

The effect was studied of the variations of the electromagnetic properties of the three phases of water on measurements of atmospheric and oceanographic parameters by microwave instruments aboard satellites. Other studies reported include: orbital detection of extrasolar planets, detection of stratospheric aerosols from earth orbit, chemistry of Jupiter's atmosphere, and stratospheric ozone.

Miller, J. E.↗

Examination of silicon solar cells by means of the Scanning Laser Acoustic Microscope (SLAM)

The Scanning Laser Acoustic Microscope produces images of internal structure in materials. The acoustic microscope is an imaging system based upon acoustic rather than electromagnetic waves. Variations in the elastic propertis are primarily responsible for structure visualized in acoustic micrographs. The instrument used in these investigations is the SONOMICROSCOPE 100 which can be operated at ultrasonic frequencies of from 30 MHz to 500 MHz. The examination of the silicon solar cells was made at 100 MHz. Data are presented in the form of photomicrographs.

Vorres, C.↗

Artificial Crater Formation on Satellite Surfaces Using an Orbiting Railgun

The specification of greater than 45kW of disposable power available on the JIMO spacecraft raises the possibility of a new class of instrumentation that has utility at such power levels. In this presentation we discuss the concept of an electromagnetic mass driver that can launch projectiles from orbit around one of the Galilean satellites directed on a trajectory that will impact the satellite surface. The resulting impact will create a crater that will provide information on the mechanical properties of surface and near-surface materials, expose subsurface materials for remote spectral identification, and form a vapor cloud that can be sensed for composition either remotely or in-situ. An analog for such a controlled cratering experiment is Deep Impact, a mission to observe the crater and ensuing ejecta cloud formed by a ballistic projectile into a comet surface in July, 2005.

Dissly, R. W.↗

STROBE-X: X-ray Timing & Spectroscopy on Dynamical Timescales from Milliseconds to Years

We describe a probe-class mission concept that provides an unprecedented view of the X-ray sky, performing timing and 0.2-30 keV spectroscopy over timescales from microseconds to years. The Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X) has three key science drivers: (1) measuring the spin distribution of accreting black holes, (2) understanding the equation of state of dense matter, and (3) exploring the properties of the precursors and electromagnetic counterparts of gravitational wave sources. To perform these science investigations, STROBE-X comprises three primary instruments. The first uses an array of lightweight optics (3-m focal length) that concentrate incident photons onto solid state detectors with CCD-level (85-130 eV) energy resolution, 100 ns time resolution, and low background rates to cover the 0.2-12 keV band. This technology is scaled up from NICER, with enhanced optics to take advantage of the longer focal length of STROBE-X. The second uses large-area collimated silicon drift detectors, developed for ESA's LOFT, to cover the 2-30 keV band. These two instruments each provide an order of magnitude improvement in effective area compared with its predecessor (NICER and RXTE, respectively). Finally, a sensitive sky monitor triggers pointed observations, provides high duty cycle, high time resolution, high spectral resolution monitoring of the X-ray sky with ~20 times the sensitivity of the RXTE ASM, and enables multi-wavelength and multi-messenger studies on a continuous, rather than scanning basis. The STROBE-X mission concept is a rapidly repointable observatory in low-Earth orbit, similar to RXTE or Swift, and will be presented to the 2020 Astrophysics Decadal Survey for consideration as a probe-class mission.

STROBE-X: X-ray↗

As Seen by Parker Solar Probe: In-Situ Signatures of Wave-Particle Interactions Driven by Solar Ejecta

Parker Solar Probe (PSP) is sampling regions of the inner heliosphere never seen before to address where and why energy flows between the Sun and earth. With the onset of solar maximum, recent encounters have witnessed the increase in solar activity. We present in-situ signatures of coronal mass ejections and other smaller transients of coronal origin. Using simultaneous measurements from the SWEAP and FIELDS instrument suite, both ion and electron-scale dynamics are investigated in coincidence with both lower frequency electromagnetic and higher frequency electrostatic waves. We present an overview of these wave-particle interaction observations and hypothesize on their role in plasma energization and subsequent solar wind heating.

J. L. Verniero↗

Active multispectral imaging system for photodiagnosis and personalized phototherapies

The proposed system has been designed to identify dermatopathologies or to apply personalized phototherapy treatments. The system emits electromagnetic waves in different spectral bands in the range of visible and near infrared to irradiate the target (skin or any other object) to be spectrally characterized. Then, an imaging sensor measures the target response to the stimulus at each spectral band and, after processing, the system displays in real time two images. In one of them the value of each pixel corresponds to the more reflected wavenumber whereas in the other image the pixel value represents the energy absorbed at each band. The diagnosis capability of this system lies in its multispectral design, and the phototherapy treatments are adapted to the patient and his lesion by measuring his absorption capability. This “in situ” absorption measurement allows us to determine the more appropriate duration of the treatment according to the wavelength and recommended dose. The main advantages of this system are its low cost, it does not have moving parts or complex mechanisms, it works in real time, and it is easy to handle. For these reasons its widespread use in dermatologist consultation would facilitate the work of the dermatologist and would improve the efficiency of diagnosis and treatment. In fact the prototype has already been successfully applied to pathologies such as carcinomas, melanomas, keratosis, and nevi.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction and response of a highly granular scintillator-based electromagnetic calorimeter

Here, a highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future linear collider experiments. A prototype of 21.5 X 0 depth and 180 × 180 mm 2 transverse dimensions was constructed, consisting of 2160 individually read out 10 × 45 × 3 mm 3 scintillator strips. This prototype was tested using electrons of 2–32 Ge V at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1%, and the intrinsic energy resolution was determined to be ( 12 . 5 ± 0 . 1 ( stat. ) ± 0 . 4 ( syst. ) ) % / E [ Ge V ] ⊕ ( 1 . 2 ± 0 . 1 ( stat. ) - 0 . 7 + 0 . 6 ( syst. ) ) % , where the uncertainties correspond to statistical and systematic sources, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗