Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Integrating Energy Efficiency Strategies with Industrialized Construction for Our Clean Energy Future: Preprint

NREL’s Industrialized Construction Innovation Team has developed an ambitious plan to accelerate the integration of energy efficiency (EE) strategies with Industrialized Construction (IC). The United States (U.S.) construction industry is beginning to use IC methods to build multifamily apartment buildings to address affordability and labor shortages. Apart from reducing cost of construction and delivery times, the IC method of permanent modular construction has the potential to facilitate the integration of a wide range of EE strategies and advanced controls into such buildings. While there may be unintended EE benefits to IC such as a tighter envelope due to higher construction quality, the process has not been leveraged specifically to enhance EE. NREL aims to claim this missed opportunity and integrate IC benefits with EE as well as advanced controls, distributed energy resources, and grid-friendly design strategies. The paper proposes an ‘IC Assessment Framework’ to achieve affordable zero-energy modular multifamily buildings. Through the selection criteria of Design for Manufacturing and Assembly, the framework aims to distill a broad range of proven EE strategies for site-built into a set of strategies that qualify as easy to integrate for off-site. The output is a Factory Information Model (FIM) that represents a process-based digital twin to enable advanced time-and-motion study, plugs into open source building energy modeling platform (EnergyPlus), and serves as a vital tool facilitating wider adoption of EE integration. Conclusively, the paper delineates next steps for upcoming pilots with NREL’s IC partners towards developing a transformational pathway for our Clean Energy Future.

30 DIRECT ENERGY CONVERSION↗

VOLTTRON™ Agent Development for Enabling Reactive Power Support of Non-Utility DERs by Integrating Transactive Energy Approach

To enable better voltage regulation in power systems with high penetration of photovoltaics (PV) and other distributed energy resources (DERs), future inverters are required to provide reactive power support to the grid in addition to providing real power generated by PV panels. This paper develops a framework that coordinates the support from DER-based inverters, which are grid-connected non-utility assets, by using a transactive energy approach. Results of the implementation demonstrate participation of DER-based inverters can be achieved by using the coordination between distributed controllers and a centralized controller. With the transactive energy approach, both the customer and utility can achieve benefits that meet their individual needs.

Kritprajun, Paychuda↗

Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100)

Puerto Rico has committed to meeting its electricity needs with 100% renewable energy by 2050, along with realizing interim goals of 40% by 2025, 60% by 2040, the phaseout of coal-fired generation by 2028, and a 30% improvement in energy efficiency by 2040 as established in Puerto Rico Energy Public Policy Act (Act 17). To meet these goals and support widespread end-use electrification, Puerto Rico is exploring renewable energy and innovative technologies for energy storage, distributed generation, distribution control, electric vehicles, and energy efficient and responsive loads that can be deployed in each of Puerto Rico's cities and communities. Launched in February 2022, a two-year study entitled Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy (PR100) will perform a comprehensive analysis of stakeholder-driven pathways to Puerto Rico's clean energy future. This fact sheet describes the five activities this robust and objective energy analysis entails.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Darlington tritium removal facility and station upgrading plant dynamic process simulation

Ontario Power Generation Nuclear (OPGN) has a 4 x 880 MWe CANDU nuclear station at its Darlington Nuclear Div. located in Bowmanville. The station has been operating a Tritium Removal Facility (TRF) and a D{sub 2}O station Upgrading Plant (SUP) since 1989. Both facilities were designed with a Distributed Control System (DCS) and programmable logic controllers (PLC) for process control. This control system was replaced with a DCS only, in 1998. A dynamic plant simulator was developed for the Darlington TRF (DTRF) and the SUP, as part of the computer control system replacement. The simulator was used to test the new software, required to eliminate the PLCs. The simulator is now used for operator training and testing of process control software changes prior to field installation. Dynamic simulation will be essential for the ITER isotope separation system, where the process is more dynamic than the relatively steady-state DTRF process. This paper describes the development and application of the DTRF and SUP dynamic simulator, its benefits, architecture, and the operational experience with the simulator. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Potential applications of industrial wireless technologies in the future HTR - 18505

High Temperature Reactor (HTR) is a kind of promising nuclear reactor for supplying electricity and heat with inherent safety. The High Temperature Reactor-Pebble bed Modular reactor (HTR-PM) in China is equipped with the Distributed Control System (DCS) where wired network is applied mainly based on fiber. Considering the difficulty and cost of implementation, the flexibility of network configuration and maintenance, the industrial wireless network might be potential for some cases in the network of the next generation of HTR. Nowadays, there are several technologies available for choice, such as wireless HART, WIA-PA and ZigBee. Characteristics of these technologies are introduced. The most important factors for choice of the technology of network are the required reliability and latency tolerance of communication. Analysis and classification of the communications needed in the network of the HTR are carried out, and a comparison of popular industrial wireless technologies, including the reliability, the latency, the communication distance, and the difficulty and cost of implementation is made. Generally speaking, considering the low latency, high reliability and the compatibility with HART devices, wireless HART is promising. WIA-PA could be applied if redundant gateway is required. ZigBee might show its advantages in power consumption and cost. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DCIS integration tests for Lungmen nuclear power plant - 370

The factory acceptance tests (FAT) for distributed control and information systems (DCIS) of Lungmen nuclear power plant (LMNPP) Units 1 and 2 were separately performed by individual suppliers for their supplied scopes. The FAT also included overlap interface tests between the separately supplied scopes, but did not include an overall integration test. There were concerned by the regulator and the public over the lack of an integration test, which was believed to be indispensable to verify the correctness and completeness of a digital system of such large scale ever applied by Taiwan Power Company (Taipower). To address these concerns and enhance confidence in the DCIS, the DCIS integration tests, including reactor water level integration test, reactor pressure integration test, integration test for turbine generator and reactor protection system, integration test for proper plant response to safety and non-safety network equipment failures, and DCIS dynamic integration test, were performed at site during Unit 1| site tests. It is to be noted that these tests were beyond the post construction tests, the pre-operational tests, and the start-up tests, which are the normal industry practice and formally required by the regulator. A common goal for these integration tests is to verify the capability of the DCIS to transmit signal/data properly across various suppliers' equipment to actuate the final equipment. The methods and principle, the test purpose/test items/acceptance criteria and the test results for these tests are described. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Upscaling of Bio-mediated Soil Improvement

As demand for soil improvement continues to increase, new, sustainable, and innocuous methods are needed to alter the mechanical properties of soils. Recent research has demonstrated the potential of bio-mediated soil improvement for geotechnical applications (DeJong et al. 2006, Whiffin et al. 2007). Upscaling the bio-mediated treatment process for in situ implementation presents a number of challenges to be addressed, including soil and pore fluid interactions, bioaugmentation versus biostimulation of microbial communities, controlled distribution of mediated calcite precipitation, and permanence of the cementation. Current studies are utilizing large-scale laboratory experiments, non-destructive geophysical measurements, and modeling, to develop an optimized and predictable bio-mediated treatment method.

54 ENVIRONMENTAL SCIENCES↗

Grid-Edge resource controller to enhance distribution grid resilience [SWR-19-70]

This Grid-Edge resource controller provides an unprecedented operational resilience enhancement solution for distribution grids to achieve the lowest system degradation and fast service restoration during extreme events. Specifically, it involves integrated planning and operation approaches that provide distribution grids with a self-evolving capability on dynamically altering system topology and adjusting the operations of edge-intelligent resources in response to dynamic weather disruptions.

Ding, Fei↗

Improving Advanced Inverter Control Convergence in Distribution Power Flow

Simulation of modern distribution system powerflow increasingly requires capturing the impact of advanced PV inverter voltage regulation on powerflow. With Volt/var control, the inverter adjusts its reactive power flow as a function of the point of common coupling (PCC) voltage. Similarly, Volt/watt control curtails active power production as a function of PCC voltage. However, with larger systems and higher penetrations of PV, this active/reactive power flow itself can cause significant changes to the PCC voltage potentially introducing oscillations that slow the convergence of system simulations. Improper treatment of these advanced inverter functions could potentially lead to incorrect results. This paper explores a simple approach to speed such convergence by blending in the previous iteration's reactive power estimate to dampen these oscillations. Results with a single large (5MW) PV system and with multiple 500kW advanced inverters show dramatic improvements using this approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Numerical investigations on hot-zone modified DS furnace for mc-Si growth process

A transient global numerical model has been carried out to simulate the multi-crystalline silicon growth process by the directional solidification method using CGSim 15.1. A two dimensional axisymmetric model was used. The conductive, convective, and radiative heat transfer problems were coupled with our model and these problems were solved iteratively using the finite volume method. In the present work we have modified the heater element to produce a high quality ingot from multi-crystalline silicon. The change has been made to control the temperature distribution. By controlling the temperature distribution, we can also control the melt crystal interface of the ingot. The shape of the melt-crystal interface of the ingot, the temperature distribution in the crucible and the heat flux from the melt as well as from the crystal have been studied. Finally, the simulation results show that the modification in the heater element keeps the melt-crystal interface as planar in the DS system, also it gives better results than conventional system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Controlled quantum key distribution with three-photon polarization-entangled states via the collective noise channel

Using three-photon polarization-entangled GHZ states or W states, we propose controlled quantum key distribution protocols for circumventing two main types of collective noise, collective dephasing noise, or collective rotation noise. Irrespective of the number of controllers, a three-photon state can generate a one-bit secret key. The storage technique of quantum states is dispensable for the controller and the receiver, and it therefore allows performing the process in a more convenient mode. If the photon cost in a security check is disregarded, then the efficiency theoretically approaches unity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive Reinforcement Learning Control for Power Distribution in Multi-Output Resonant Converters

This paper presents an adaptive reinforcement learning (ARL)-based control framework for efficient power distribution in a multi-output resonant converter for UAV applications. The proposed system is based on a high-frequency isolated resonant architecture, where a single energy source supplies multiple propulsion loads through independently controlled output rectifiers, addressing the need for coordinated multi-motor power management. The ARL framework dynamically allocates output power by learning optimal phase-shift control actions under varying load demands and operating conditions. The agent autonomously determines control parameters that maximize conversion efficiency while ensuring accurate power sharing among multiple outputs. In addition, the proposed approach enables adaptive operation without requiring detailed system modeling or manual tuning. Experimental results demonstrate stable and efficient performance over a wide range of operating conditions, confirming the effectiveness and robustness of the learning-based control strategy for multi-output resonant converter system.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Advanced Distributed Wind Turbine Controls Series: Part 4-Wind Energy in Microgrids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years, the technical capabilities and requirements for distributed wind turbines to provide ancillary services beyond maximum energy production has increased. Ancillary services, leveraged through advanced wind turbine controls, can support grid stability, reliability, and resilience. In the context of a microgrid, wind turbines can provide ancillary services that are useful in both islanded and grid-connected modes, as demonstrated in previous parts of this report series. This report focuses on how wind turbines with advanced controls and power electronics can support the stability of the microgrid during transitions from grid-connected to island mode, and back. This report documents simulation results from a model of the National Renewable Energy Laboratory (NREL) Flatirons Campus containing NREL's 600-kilowatt Controls Advanced Research Turbine. Using this turbine, we demonstrate through desktop simulation how a wind turbine can support the voltage and frequency of a microgrid during transitions - from making planned transitions seamless to keeping all loads online during some unplanned transitions to supporting black start in the event of an open transition (blackout).

17 WIND ENERGY↗

Synthetic, Realistic Transmission and Distribution Co-Simulation for Voltage Control Benchmarking

As distributed energy resources (DERs) play an increasing role in generation and grid services, control and market paradigms will need to be tested with models that incorporate transmission and distribution systems. The test systems will need to be realistic and accessible for researchers to form conclusions about realistic behaviors and maintain comparability and repeatability of results. These test systems also must have high resolution models of sufficient size for realistic distribution and transmission interaction. This paper demonstrates the tightly coupled HELICS-based co-simulation of realistic synthetic distribution and transmission models for the Austin metropolitan area and how this framework can be used to analyze resultant behaviors from distributed resources and their controls. These results are compared to the same distribution system run without co-simulation using a fixed feed-in voltage. Results show that even without advanced voltage controls, the feed-in voltage response when coupled to the transmission system results a lower level of voltage excursions, suggesting the importance of using this type of realistic, tightly coupled, transmission and distribution cosimulation when assessing DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

Synthetic, Realistic Transmission and Distribution Co-Simulation for Voltage Control Benchmarking

As distributed energy resources (DERs) play an increasing role in generation and grid services, control and market paradigms will need to be tested with models that incorporate transmission and distribution systems. The test systems will need to be realistic and accessible for researchers to form conclusions about realistic behaviors and maintain comparability and repeatability of results. These test systems also must have high resolution models of sufficient size for realistic distribution and transmission interaction. This paper demonstrates the tightly coupled HELICS-based co-simulation of realistic synthetic distribution and transmission models for the Austin metropolitan area and how this framework can be used to analyze resultant behaviors from distributed resources and their controls. These results are compared to the same distribution system run without co-simulation using a fixed feed-in voltage. Results show that even without advanced voltage controls, the feed-in voltage response when coupled to the transmission system results a lower level of voltage excursions, suggesting the importance of using this type of realistic, tightly coupled, transmission and distribution co-simulation when assessing DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

Using field emission to control the electron energy distribution in high-pressure microdischarges at microscale dimensions

Particle simulations of high-pressure microdischarges at gaps below 10 μm show that the electron energy distribution becomes non-continuous, with discrete peaks corresponding to specific inelastic collisions. The relative magnitude of these peaks and shape of the energy distribution can be directly controlled by the parameter pressure times distance (pd) and the applied potential across the gap. These parameters dictate inelastic collisions experienced by electrons and as both increase the distribution smooths into a Maxwellian-like distribution. By capitalizing on field emission at these dimensions, it is possible to control the energy distribution of free electrons to target specific, energy dependent reactions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-Agent Deep Reinforcement Learning for Realistic Distribution System Voltage Control Using PV Inverters

Over the last few decades, the deployment of distributed solar photovoltaic (PV) systems has increased consistently. High PV penetration could cause adverse effects on the grid, such as voltage violations. This paper proposes a new distributed soft actor-critic based multi-agent deep reinforcement learning (SAC-MADRL) control solution to minimize the PV real power curtailment while keeping the grid voltage in an acceptable range. New reward functions have been designed to coordinate different agents during the learning process, yielding improved convergence. Comparison results with other control methods on a real feeder in western Colorado U.S. with 80% penetration of PVs demonstrate that the proposed method has better capability of effectively regulating voltage while minimizing the PV real power curtailment.

distribution system↗

Advanced Distributed Wind Turbine Controls Series: Part 3-Wind Energy in Grid-Connected Deployments – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years the technical ability and requirement for distributed wind turbines to provide grid support services beyond maximum energy production has increased. Ancillary services leveraged through advance controls of a wind turbine support grid reliability and resilience. One ancillary service that is significant to a grid-connected wind turbine deployment is fault ride through (FRT) in response to the voltage and frequency events in the power system. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, the wind turbine's FRT capabilities to support stable grid operation. We establish that the wind turbine models exceed FRT performance requirements stipulated in IEEE 1547-2018, regarding interconnection and interoperability of distributed energy resources. Utilizing a standalone CART2 (600 kW) wind turbine connected to the NREL's Flatirons Campus grid, we study voltage and frequency FRT utilizing various test cases. One of the test cases under study is a Category III voltage fault defined in IEEE 1547-2018 and derived from CA Rule 21. Some distributed wind turbines were unable to connect to the grid following the Rule 21 enforcement in California. Even if this is not a general requirement elsewhere, the grid codes might evolve in this direction. This study illustrates how a distributed wind turbine can provide some of these FRT services and enable a pathway toward a higher contribution of renewable energy in a distribution grid.

17 WIND ENERGY↗