Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Effect of Electron Irradiation with an Energy of 0.9 MeV on the I–V Characteristics and Low-Frequency Noise in 4H–SiC pin Diodes

It is established experimentally that noticeable changes in the I–V characteristics and low-frequency noise in 4H-SiC pin diodes irradiated by electrons with an energy of 0.9 MeV are observed after doses of Φ ≥ 1.4 × 10{sup 15} cm{sup –2}. The currents in the forward and reverse branches of the I–V characteristics vary nonmonotonically at voltages lower than 2 V with increasing dose, which is explained by the interaction between the excited electronic subsystem and metastable defects. In this case, a steady increase in the ideality factor and the series resistance of diodes in the region of exponential growth of the I–V characteristics at voltages exceeding 2 V is observed. The reliable operation of microwave devices with low-noise 4H-SiC pin diodes under conditions of electron irradiation is possible up to a cumulative dose of Φ ≤ 10{sup 15} cm{sup –2}. In microwave devices, the level of low-frequency noise in which is irrelevant but the stabile regime of parameters is of importance, the dose can be increased to Φ ≈ 8 × 10{sup 15} cm{sup –2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measuring the Electronic Bandgap of Carbon Nanotube Networks in Non-Ideal p-n Diodes

The measurement of the electronic bandgap and exciton binding energy in quasi-one-dimensional materials such as carbon nanotubes is challenging due to many-body effects and strong electron–electron interactions. Unlike bulk semiconductors, where the electronic bandgap is well known, the optical resonance in low-dimensional semiconductors is dominated by excitons, making their electronic bandgap more difficult to measure. In this work, we measure the electronic bandgap of networks of polymer-wrapped semiconducting single-walled carbon nanotubes (s-SWCNTs) using non-ideal p-n diodes. We show that our s-SWCNT networks have a short minority carrier lifetime due to the presence of interface trap states, making the diodes non-ideal. We use the generation and recombination leakage currents from these non-ideal diodes to measure the electronic bandgap and excitonic levels of different polymer-wrapped s-SWCNTs with varying diameters: arc discharge (~1.55 nm), (7,5) (0.83 nm), and (6,5) (0.76 nm). Our values are consistent with theoretical predictions, providing insight into the fundamental properties of networks of s-SWCNTs. The techniques outlined here demonstrate a robust strategy that can be applied to measuring the electronic bandgaps and exciton binding energies of a broad variety of nanoscale and quantum-confined semiconductors, including the most modern nanoscale transistors that rely on nanowire geometries.

36 MATERIALS SCIENCE↗

Charge Collection in Simple EPI Diodes

Charge collection from ion tracks in epi diodes is investigated by computer simulations. As previously noted by others, collected charge can exceed charge liberated in the epi layer. Several cases are compared to illustrate the effect of changing ion LET, epi doping density, and doping types. It is found that the n(sup +)-p-p(sup +) diode displays a funneling regime and a diffusion regime (as previously noted by others),, but the p(sup +)-n-n(sup +) diode does not. Simple models are proposed for quantitative estimates of collected charge. A qualitative two-state picture of funneling is discussed.

epi diodes↗

On the Long-Term Stability of Microwave Radiometers Using Noise Diodes for Calibration

Results are presented from the long-term monitoring and calibration of the National Aeronautics and Space Administration Jason Microwave Radiometer (JMR) on the Jason-1 ocean altimetry satellite and the ground-based Advanced Water Vapor Radiometers (AWVRs) developed for the Cassini Gravity Wave Experiment. Both radiometers retrieve the wet tropospheric path delay (PD) of the atmosphere and use internal noise diodes (NDs) for gain calibration. The JMR is the first radiometer to be flown in space that uses NDs for calibration. External calibration techniques are used to derive a time series of ND brightness for both instruments that is greater than four years. For the JMR, an optimal estimator is used to find the set of calibration coefficients that minimize the root-mean-square difference between the JMR brightness temperatures and the on-Earth hot and cold references. For the AWVR, continuous tip curves are used to derive the ND brightness. For the JMR and AWVR, both of which contain three redundant NDs per channel, it was observed that some NDs were very stable, whereas others experienced jumps and drifts in their effective brightness. Over the four-year time period, the ND stability ranged from 0.2% to 3% among the diodes for both instruments. The presented recalibration methodology demonstrates that long-term calibration stability can be achieved with frequent recalibration of the diodes using external calibration techniques. The JMR PD drift compared to ground truth over the four years since the launch was reduced from 3.9 to - 0.01 mm/year with the recalibrated ND time series. The JMR brightness temperature calibration stability is estimated to be 0.25 K over ten days.

noise diode (ND)↗

Generation of 369.4 nm Radiation by Efficient Doubling of a Diode Laser

The trapped ytterbium ion frequency standard under development at JPL is designed to supply ultra-stable reference signals to be used in spacecraft tests of general relativity and other science experiments. Only diode lasers meet the requirements of low power comsumption and small size for use aboard spacecraft, but diode lasers are not currently available at 369.4 nm wavelength. It is therefore necessary to employ frequency doubling methods to reach this frequency with diode lasers. Here we present the characteristics of the resonant cavity doubling system we have designed and preliminary UV conversion results.

ultra-stable↗

A Nanoscale Vacuum Field Emission Gated Diode with an Umbrella Cathode

A nanoscale field emission vacuum channel gated diode structure is proposed and a tungsten cathode with an umbrella-like geometry and sharp vertical edge is fabricated. The edge of the suspended cathode becomes the field emission surface. Unlike in the traditional transistor with the gate typically located between the source and the drain, the bottom silicon plate becomes the gate here and the anode terminal is located between the umbrella cathode and the gate. The fabricated devices show excellent diode characteristics and the gated diode structure is attractive for extremely low gate leakage.

Vacuum field emission diode↗

X-ray Diode Preparation

A rod pinch x-ray diode assembly culminates in a coaxial anode cathode arrangement where a small anode rod extends through the aperture of a cathode plate. Shotto- shot repeatability in rod placement, and thus x-ray source spot position, has potential to positively affect radiographic image quality. Thus, how to both control and measure, according to a Cartesian coordinate system, anode rod tip displacement (x, y) (off the beam line-of-sight retical) and also anode rod tip extension (z) (along the line-of-sight center line) become salient issues relative to radiographic image set utility. To address these issues both hardware fabrication and x-ray diode assembly methods were reviewed, and additional controls were introduced. A photogrammetric procedure was developed to quantify anode rod tip position in situ. Computer models and mock-up assemblies with precision fiducials were produced to validate this procedure. Therefore, both anode rod tip displacement and anode rod tip extension parameters were successfully controlled. Rod position was measured and met the required specifications: (1) radial displacement <0.25 mm and (2) axial placement of ±0.25 mm. We demonstrated that precision control and measurement of large scale components is achievable in a pulse power system (i.e., hardware and operations). Correlations with diode performance and radiography are presented.

42 ENGINEERING↗

Plasma Measurements in High Intensity Electron Beam Diodes

Experiments are being performed on the Self-Magnetic Pinch (SMP) electron beam diode on the RITS-6 accelerator at Sandia National Laboratories. This diode produces a tightly focused electron beam (< 3mm diameter) which is incident on a high atomic number bremsstrahlung x-ray converter. Typical diode parameters are 120 kA, 7 MeV, and 70ns current pulse, giving a ~45ns x-ray pulse. Plasmas from contaminants on the electrode surfaces propagate into the A-K vacuum gap, affecting the impedance, x-ray spectrum, and pulse width. These plasmas are measured using diagnostics, which include: spectroscopy, optical imaging, and photon detection; to obtain velocity, density, and temperature information. These parameters are measured both spatially, using multi-fiber arrays, and temporally, using streak cameras and avalanche photodiodes. Plasma densities and temperatures are determined from detailed, time-dependent, collisional-radiative (CT) and radiation transport (RT) models, which include Stark broadening of the hydrogen-alpha transition line and carbon ion line ratios. These results are combined with hybrid PIC/fluid simulations to model the plasma’s overall behavior. Densities of up to 10^19 cm-3 have been measured on the electrode surfaces, decreasing by several orders of magnitude both radially and axially across the vacuum gap. Electrode plasma expansion velocities of up to 10 cm/microsecond correlate well with the decreasing impedance profile (~0.5 Ohms/ns) observed during the pulse.

electron beam diodes↗

Data Diodes in Support of Trustworthy Cyber Infrastructure

Interconnections between process control networks and en- terprise networks has resulted in the proliferation of stan- dard communication protocols in industrial control systems which exposes instrumentation, control systems, and the critical infrastructure components they operate to a variety of cyber attacks. Various standards and technologies have been proposed to protect industrial control systems against cyber attacks and to provide them with confidentiality, in- tegrity, and availability. Among these technologies, data diodes provide protection of critical systems by the means of physically enforcing traffic direction on the network. In order to deploy data diodes effectively, it is imperative to un- derstand the protection they provide, the protection they do not provide, their limitations, and their place in the larger security infrastructure. In this work, we briefly review the security challenges in an industrial control system, study data diodes, their functionalities and limitations, and pro- pose a scheme for their effective deployment in trusted pro- cess control networks (TPCNs.)

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

{sup 32}P Brachytherapy Conformal Source Model RIC-100 for High-Dose-Rate Treatment of Superficial Disease: Monte Carlo Calculations, Diode Measurements, and Clinical Implementation

Purpose: A novel {sup 32}P brachytherapy source has been in use at our institution intraoperatively for temporary radiation therapy of the spinal dura and other localized tumors. We describe the dosimetry and clinical implementation of the source. Methods and Materials: Dosimetric evaluation for the source was done with a complete set of MCNP5 Monte Carlo calculations preceding clinical implementation. In addition, the depth dose curve and dose rate were measured by use of an electron field diode to verify the Monte Carlo calculations. Calibration procedures using the diode in a custom-designed phantom to provide an absolute dose calibration and to check dose uniformity across the source area for each source before treatment were established. Results: Good agreement was established between the Monte Carlo calculations and diode measurements. Quality assurance measurements results are provided for about 100 sources used to date. Clinical source calibrations were usually within 10% of manufacturer specifications. Procedures for safe handling of the source are described. Discussion: Clinical considerations for using the source are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fabrication and characterization of n-type aluminum-boron co-doped ZnO on p-type silicon (n-AZB/p-Si) heterojunction diodes

Graphical abstract: - Highlights: • n-AZB/p-Si heterojunction diodes were formed. • n-AZB/p-Si diode annealed at 700 °C showed best rectifying behavior. • Zn{sub 2}SiO{sub 4} was formed at 800 °C. • n and ϕ{sub b} were estimated to be 1.63 and 0.4 eV, respectively, at 700 °C. • Tailoring of BG was attributed to annealing induced stresses in the films. - Abstract: In this paper, the growth of n-type aluminum boron co-doped ZnO (n-AZB) on a p-type silicon (p-Si) substrate by sol–gel method using spin coating technique is reported. The n-AZB/p-Si heterojunctions were annealed at different temperatures ranging from 400 to 800 °C. The crystallite size of the AZB nanostructures was found to vary from 28 to 38 nm with the variation in annealing temperature. The band gap of the AZB decreased from 3.29 to 3.27 eV, with increasing annealing temperature from 400 to 700 °C and increased to 3.30 eV at 800 °C probably due to the formation of Zn{sub 2}SiO{sub 4} at the interface. The band gap variation is explained in terms of annealing induced stress in the AZB. The n-AZB/p-Si heterojunction exhibited diode behavior. The best rectifying behavior was exhibited at 700 °C.

36 MATERIALS SCIENCE↗

Weekly Verification of Dosimetric Data for Virtual Wedge Using a 2D Diode Detector Array

A linac manufacturer has recommended that users measure virtual wedge (VW) angle and VW factor as a weekly quality assurance (QA) procedure. The purpose of this study was to investigate whether a 2D diode detector array (MapCHECK{sup TM}) is a useful tool for the verification of dosimetric data for VW. Measurements were performed on 2 linear accelerators (4, 6, and 10 MV) at 10-cm depth for a field size of 10 x 10 cm{sup 2} and with wedge angles of 15, 30, 45, and 60{sup o}. To verify the VW dose distributions generated by the treatment planning system (TPS), we confirmed that agreement between TPS data and measurements were {<=}2% dose difference or 2-mm distance-to-agreement based on American Association of Physicists in Medicine Task Group Report 53 (AAPM TG-53). We present here the results of a 1-year evaluation of VW by means of a 2D diode detector array. The maximum 2-fold standard deviation of the measured wedge angle turned out to be within 1.0, and all measured VW factors to be 1.00 {+-} 0.03. Although >95% of the points measured for 6 and 10 MV were generally within the tolerance of the dose distribution as mentioned above, the percentage of agreement between the measured data for 4 MV and TPS data were somewhat below 90%. We also verified generally good reproducibility for the dose distribution. The 2-D diode detector array was thus found to be useful as a tool for weekly VW QA.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design optimization of semiconductor piezoresistors with Schottky diode contacts

A modeling theory is developed to predict the performance of piezoresistors which incorporate Schottky diode electrical contacts. This new theory allows the design of high performance gauges which can be fabricated using NonLithographically-Based Microfabrication (NLBM) techniques. These semiconductor piezoresistors can be designed in customizable sizes and fabricated in parallel in order to integrate position sensing into MEMS flexural positioners. Customizable nanopositioning platforms will enable advances in a range of nano-scale fabrication and metrology applications. A semiconductor piezoresistor with Schottky diode contacts was fabricated and attached to a titanium flexure. This device is shown to match predicted electrical performance within about 8% and to show a gauge factor of 116, within 2% of the predicted value. Performance limits for Schottky diode semiconductor piezoresistors are identified to be about 127dB full noise dynamic range for a quarter bridge over a 10kHz sensor bandwidth on a 600µm width titanium flexure, making them ideal for sensing on meso-/micro-scale flexural positioners. Methods of reaching these performance bound are suggested and their impact on the sensor dynamic range are studied.

42 ENGINEERING↗

Highly Rectifying Fluidic Diodes Based on Asymmetric Layer-by-Layer Nanofilms on Nanochannel Membranes

Nanochannel-based fluidic diodes display ion selectivity and ion-current rectification (ICR), which may prove important in energy harvesting and biosensors. This paper reports asymmetric functionalization of the outer surface of a flexible nanochannel polymer membrane to create fluidic diodes that give ICR. Layer-by-layer (LbL) adsorption with cross-linking of only the underlying part of the polyelectrolyte nanofilm leads to a porosity step across the film. The combination of a high effective surface-charge density and the porosity step in the film leads to a remarkable maximum ICR factor of ~200 with a pH gradient across the film. Incorporation of pH-sensitive polyelectrolyte components enables the ICR factor to increase an order of magnitude on going from pH 8 to pH 3. Furthermore, the coated membrane shows excellent anion-selectivity. Thus, LbL adsorption with partial cross-linking provides a simple method for creating coated nanochannel membranes that serve as pH-responsive ionic diodes for potential chemical/biosensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Etched-And-Regrown GaN P–N Diodes with Low-Defect Interfaces Prepared by In Situ TBCl Etching

The ability to form pristine interfaces after etching and regrowth of GaN is a prerequisite for epitaxial selective area doping, which in turn is needed for the formation of lateral PN junctions and advanced device architectures. In this work, we report the electrical properties of etched-and-regrown GaN PN diodes using an in situ Cl-based precursor, tertiary butylchloride (TBCl). We demonstrated a regrowth diode with I–V characteristics approaching that from a continuously grown reference diode. The sources of unintentional contamination from the silicon (Si) impurity and the mediating effect of Si during the TBCl etching are also investigated in this study. Furthermore, this work points to the potential of in situ TBCl etching toward the realization of GaN lateral PN junctions.

36 MATERIALS SCIENCE↗

Investigating underlying mechanism in spectral narrowing phenomenon induced by microcavity in organic light emitting diodes

This paper reports our experimental studies on the underlying mechanism responsible for electroluminescence spectral narrowing phenomenon in the cavity-based organic lightemitting diodes. It is found that the microcavity generates an emerging phenomenon: a magneto-photoluminescence signal in Poly(9,9-dioctylfluorene-alt-benzothiadiazole) polymer under photoexcitation, which is completely absent when microcavity is not used. This provides an evidence that microcavity leads to the formation of spatially extended states, functioning as the intermediate states prior to the formation of Frenkel excitons in organic materials. This is confirmed by the magneto-electroluminescence solely observed from the cavity-based light-emitting diodes under electrical injection. Furthermore, the narrowed electroluminescence output shows a linear polarization, concurrently occurred with magnetoelectroluminescence. This indicates that the spatially extended sates become aligned towards forming coherent light-emitting excitons within the microcavity through optical resonance. Clearly, the spatially extended states present the necessary condition to realize electroluminescence spectral narrowing phenomenon towards lasing actions in cavity-based organic light-emitting diodes.

36 MATERIALS SCIENCE↗

Grain engineering for efficient near-infrared perovskite light-emitting diodes

Metal halide perovskites show promise for next-generation light-emitting diodes, particularly in the near-infrared range, where they outperform organic and quantum-dot counterparts. However, they still fall short of costly III-V semiconductor devices, which achieve external quantum efficiencies above 30% with high brightness. Among several factors, controlling grain growth and nanoscale morphology is crucial for further enhancing device performance. This study presents a grain engineering methodology that combines solvent engineering and heterostructure construction to improve light outcoupling efficiency and defect passivation. Solvent engineering enables precise control over grain size and distribution, increasing light outcoupling to ~40%. Constructing 2D/3D heterostructures with a conjugated cation reduces defect densities and accelerates radiative recombination. The resulting near-infrared perovskite light-emitting diodes achieve a peak external quantum efficiency of 31.4% and demonstrate a maximum brightness of 929 W sr -1 m -2 . These findings indicate that perovskite light-emitting diodes have potential as cost-effective, high-performance near-infrared light sources for practical applications.

42 ENGINEERING↗

A red-light-powered silicon nanowire biophotochemical diode for simultaneous CO 2 reduction and glycerol valorization

A bias-free photochemical diode, in which a p-type photocathode is connected to an n-type photoanode to harness light for driving photoelectrochemical reduction and oxidation pairs, serves as a platform for realizing light-driven fuel generation from CO 2 . However, the conventional design, in which cathodic CO 2 reduction is coupled with the anodic oxygen evolution reaction (OER), requires substantial energy input. Here we present a photochemical diode device that harnesses red light (740 nm) to simultaneously drive biophotocathodic CO 2 -to-multicarbon conversion and photoanodic glycerol oxidation as an alternative to the OER to overcome the above thermodynamic limitation. The device consists of an efficient CO 2 -fixing microorganism, Sporomusa ovata, interfaced with a silicon nanowire photocathode and a Pt–Au-loaded silicon nanowire photoanode. This photochemical diode operates bias-free under low-intensity (20 mW cm –2 ) red light irradiation with ~80% Faradaic efficiency for both the cathodic and anodic products. Finally, this work provides an alternative photosynthetic route to mitigate excessive CO 2 emissions and efficiently generate value-added chemicals from CO 2 and glycerol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗