Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Gravitational Wave Symphony from Oscillating Spectator Scalar Fields

We investigate a generic source of stochastic gravitational wave background due to the parametric resonance of oscillating scalar fields in the early Universe. By systematically analyzing benchmark models through lattice simulations and considering a wide range of parameters, we demonstrate that such a scenario can lead to detectable signals in gravitational wave detectors over a broad frequency range and potentially address the recent findings by pulsar timing array experiments. Furthermore, these models naturally yield ultralight dark matter candidates or dark radiation detectable by cosmic microwave background observatories. Published by the American Physical Society 2024

Physics↗

Patterned anodes with sub-millimeter spatial resolution for large-area MCP-based photodetector systems

Micro-channel-plate-based photo-detectors are unique in being capable of covering very large areas such as those required in elementary particle and nuclear physics, while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, and time resolutions of 30 psec–50 psec for single photons. In such systems the electronic channel count is a major cost driver. Incorporating a capacitively-coupled anode allows the use of external pickup electrodes with patterns of individual channels optimized for occupancy, rate, and time/space resolution. The signal pickup antenna can be economically implemented as a printed circuit card with a 2-dimensional array of pads for high-occupancy/high-rate applications such as in particle colliders and medical imaging, or a 1-dimensional array of strips for a lower channel count in low-occupancy/low-rate applications such as large neutrino detectors. In this paper we present pad patterns that enhance signal-sharing between pads to lower the channel count per unit area in large-area systems by factors up to 4, while maintaining spatial resolutions of approximately 100 to 200 μ m for charged particles and 400 to 1000 μ m for single photons. Patterns that use multiple signal layers in the signal-pickup board can lower the channel count even further, moving the scaling behavior in the number of pads versus total area from quadratic to linear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade to Fixed and Translating Scintillation-Based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and op-erational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating de-tectors collected under varying beam conditions validate the utility of the upgrade.

Chen, Erin V. [Fermilab] (ORCID:0000000215467899)↗

Nonlocal metasurface for circularly polarized light detection

Modern-day sensing and imaging applications increasingly rely on accurate measurements of the primary physical quantities associated with light waves: intensity, wavelength, directionality, and polarization. These are conventionally performed with a series of bulky optical elements, but recently, it has been recognized that optical resonances in nanostructures can be engineered to achieve selective photodetection of light waves with a specific set of predetermined properties. Here, we theoretically illustrate how a thin silicon layer can be patterned into a dislocated nanowire-array that affords detection of circularly polarized light with an efficiency that reaches the theoretical limit for circular dichroism of a planar detector in a symmetric external environment. The presence of a periodic arrangement of dislocations is essential in achieving such unparalleled performance as they enable selective excitation of nonlocal, guided-mode resonances for one handedness of light. We also experimentally demonstrate compact, high-performance chiral photodetectors created from these dislocated nanowire-arrays. This work highlights the critical role defects can play in enabling new nanophotonic functions and devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of Sparse Static Detector Networks for City-Scale Radiological/Nuclear Detection

Sparse static detector networks in urban environments can be used in efforts to detect illicit radioactive sources, such as stolen nuclear material or radioactive "dirty bombs." We use detailed simulations to evaluate multiple configurations of detector networks and their ability to detect sources moving through a $6\times 6$ km 2 area of downtown Chicago. A detector network's probability of detecting a source increases with detector density but can also be increased with strategic node placement. Here, we show that the ability to fuse correlated data from a source-carrying vehicle passing by multiple detectors can significantly contribute to the overall detection probability. In this article, we distinguish static sensor deployments operated as networks able to correlate signals between sensors, from deployments operated as arrays where each sensor is operated individually. In particular, we show that additional visual attributes of source-carrying vehicles, such as vehicle color and make, can greatly improve the ability of a detector network to detect illicit sources.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Effects of magnetic fields on HPGe tracking detectors

Here, we present a study of magnetic fields effects on the position resolution and energy response of hyper-pure germanium detectors. Our results provide realistic estimates of the potential impact on the resolving power of tracking-arrays from (fringe) magnetic fields present when operating together with large spectrometers. By solving the equations of motion for the electron and holes in the presence of both electric and magnetic fields, we analyzed the drift trajectories of the charge carriers to determine the deviations in the positions at the end point of the trajectories, as well as changes in drift lengths affecting the energy resolution and peak shift due to trapping. Our results show that the major effect is in the deviation of the transverse (to the electric field direction) position and suggest that, if no corrective action is taken in the pulse-shape and tracking data analysis procedures, a field strength ≳ 0.1 T will start to impact the intrinsic position resolution of 2 mm (RMS). At fields above ~1 T, the degradation of the energy response becomes observable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 28 nm multiply-accumulate ASIC architecture for on-chip data compression in MHz frame rate X-ray and electron pixel detectors

Modern X-ray detector systems urgently require compact, efficient, and fast data compression schemes to handle the transmission of big data from pixel arrays, enabling frame rates in the MHz regime. Here, in this work, a data compression ASIC that implements a streaming fixed-length lossy compression scheme is introduced and analyzed, proving the feasibility and benefits of on-chip compression. The compression scheme utilizes a vector matrix product logic, which performs a number of floating-point multiplications, additions, and accumulations. The logic is verified, synthesized, and shown to fit in the area resource available for the X-ray detector under study, which comprises 192 × 168 pixels each of 12-bit width, and having a total area of 20 mm× 20 mm, about 2 mm× 20 mm of which are available for the digital logic. Several system architectures, precisions, and compression ratios ranging from 100 to 250 were analyzed to pave the way for on-chip fixed-length compression (e.g., principal component analysis, singular value decomposition) and data reduction (e.g., azimuthal integration) for X-ray and electron detectors.

Data compression↗

New measurement of double- β decays of Mo 100 to excited states of Ru 100 with the CUPID-Mo experiment

The CUPID-Mo experiment, located at Laboratoire Souterrain de Modane (France), was a demonstrator experiment for CUPID. It consisted of an array of 20 Li 2 100 MoO 4 (LMO) calorimeters each equipped with a Ge light detector (LD) for particle identification. In this work, we present the result of a search for two-neutrino and neutrinoless double beta decays of 100 Mo to the first 0 + and 2 + excited states of 100 Ru using the full CUPID-Mo exposure (2.71 kg yr of LMO). We measure the half-life of 2νββ decay to the $0^+_1$ state as $T^{2ν→0^+_1}_{1/2}$ = (7.5 ± 0.8 (stat.) $^{+0.4}_{-0.3}$ (syst.)) × 10 20 yr. The bolometric technique enables measurement of the electron energies as well as the gamma rays from nuclear de-excitation and this allows us to set new limits on the two-neutrino decay to the $2^+_1$ state of $T^{2ν→2^+_1}_{1/2}$ > 4.4×10 21 yr (90% c.i.) and on the neutrinoless modes of $T^{0ν→2^+_1}_{1/2}$ > 2.1×10 23 yr (90% c.i.), $T^{0ν→0^+_1}_{1/2}$ > 1.2 × 10 23 yr (90% c.i.). Information on the electrons spectral shape is obtained which allows us to make the first comparison of the single state (SSD) and higher state (HSD) 2νββ decay models for the $0^+_1$ excited state of 100 Ru.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report (Volume II: DUNE Physics)

The Physics volume of the DUNE far detector (FD) Technical Design Report (TDR) presents the science program of DUNE. Within, we describe the array of identified scientific opportunities and key goals. Crucially, we also report our best current understanding of the capability of DUNE to realize these goals, along with the detailed arguments and investigations on which this understanding is based. In the context of the complete set of DUNE TDR volumes, a central role for this volume is to document the scientific basis underlying the conception and design of the LBNF/DUNE experimental configurations. As a result, it is the description of DUNE’s experimental capabilities that constitutes the bulk of the document. Key linkages between requirements for successful execution of the physics program and primary specifications of the experimental configurations are drawn and summarized. This document also serves a wider purpose as a statement on the scientific potential of DUNE as a central component within a global program of frontier theoretical and experimental particle physics research. Thus, the presentation also aims to serve as a resource for the particle physics community at large. In this chapter, the scientific goals, the methodologies utilized to obtain sensitivity projections, the corresponding results for selected elements of the scientific program, and the demands placed on the experiment design and performance are presented in summary form. Together with the two chapters that follow, this summary establishes the context for the detailed descriptions specific to each area of research that comprise the remaining chapters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

System and method for adaptive optical tracking with selectable tracking modes

The present disclosure relates to an adaptive, free-space optical system. The system may have a controller and a digital micromirror (DMM) array responsive to the controller. The digital micromirror may include a plurality of independently controllable micromirror elements forming a receiver for receiving optical signals from an environmental scene. At least two of the plurality of independently controllable micromirror elements are steerable in different directions to receive optical signals emanating from two or more locations within the environmental scene. A beam steering subsystem forms a portion of the micromirror array and is in communication with the controller for receiving control signals from the controller. A detector is used to receive an incoming free space optical signal imaged by at least one of the micromirror elements.

Panas, Robert Matthew↗

A flexible test facility for liquid xenon detector development

As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. Here, we describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.

Dark Matter detectors↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

42 ENGINEERING↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Performance of the Particle-Identification Silicon-Telescope Array coupled with the VAMOS++ magnetic spectrometer

The Particle-Identification Silicon-Telescope Array (PISTA) is a new detection system designed for high-resolution studies of fission process induced by multi-nucleon transfer in inverse kinematics. It is specifically optimized for experiments with the VAMOS++ magnetic spectrometer at GANIL (Grand Accélérateur National d’Ions Lourds). The array comprises eight trapezoidal ΔE-E silicon telescopes arranged in a lamp shade configuration. Each telescope integrates two single-sided stripped silicon detectors, enabling target-like recoil identification, energy loss measurements, and trajectory reconstruction. Positioned in close proximity to the target, PISTA’s compact geometry achieves high-efficiency tracking of target-like recoils produced in multi-nucleon transfer reactions at Coulomb barrier energies. The spatial segmentation of the array allows precise determination of the mass and charge of the target-like nucleus, and excitation energy of fissioning systems. This work presents the particle identification and excitation energy reconstruction performances for the interactions of 238 U beam with 12 C target. An excitation energy resolution of 800 keV (FWHM) was determined together with mass resolution of 1.1% (FWHM). The combination of PISTA and VAMOS++ magnetic spectrometer enables unprecedented investigations of the fission process as a function of the excitation energy of the fissioning nucleus, particularly for exotic systems produced in transfer-induced reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High power density soft x-ray GaAs photodiodes with tailored spectral response

GaAs photodiode arrays have been designed for non-destructive monitoring of x-ray beam position in soft coherent beamline front ends in synchrotron light sources. A shallow p-on-n junction was employed to reduce the device photocurrent density to optimize the operation with beam power densities up to 20 W mm -2 , mainly coming from hard x-rays. With this approach, the photocurrent is primarily defined by the excess carriers generated by low-energy x-ray photons absorbed near the detector surface. The p–n junction structures were grown by molecular beam epitaxy and processed into 64-element linear photodiode arrays. The devices were characterized first in the visible range with a high-power Ar-ion laser and then tested in the soft and hard x-ray regions up to 10 keV at two beamlines of the National Synchrotron Light Source II. The responsivity was measured to be 0.16 A W -1 at 0.7 keV and 0.05 A W -1 at 6 keV in agreement with modeling. At higher x-ray energies the measured responsivity was lower than predicted in the framework of the carrier diffusion model; a possible explanation is discussed.

36 MATERIALS SCIENCE↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗