Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Anti-Icing Coatings using Ionomer Film Layer Structuring

This research effort examined the application of Nafion polymers in alcohol solvents as an anti-ice surface coating, as a mixture with hydrophilic polymers and freezing point depressant salt systems. Co-soluble systems of Nafion, polymer and salt were applied using dip coating methods to create smooth films for frost observation over a Peltier plate thermal system in ambient laboratory conditions. Cryo-DSC was applied to examine freezing events of the Nafion-surfactant mixtures, but the sensitivity of the measurement was insufficient to determine frost behavior. Collaborations with the Fog Chamber at Sandia-Albuquerque, and in environmental SAXS measurements with CINT-LANL were requested but were not able to be performed under the research duration. Since experimental characterization of these factors is difficult to achieve directly, computational modeling was used to guide the scientific basis for property improvement. Computational modeling was performed to improve understanding of the dynamic association between ionomer side groups and added molecules and deicing salts. The polyacrylic acid in water system was identified at the start of the project as a relevant system for exploring the effect of varying counterions on the properties of fully deprotonated polyacrylic acid (PAA) in the presence of water. Simulations were modeled with four different counterions, two monovalent counterions (K+ and Na+) and two divalent counterions (Ca2+ and Mg2+). The wt% of PAA in these systems was varied from ~10 to 80 wt% PAA for temperatures from 250K to 400K. In the second set of simulations, the interpenetration of water into a dry PAA film was studied for Na+ or Ca2+ counterions for temperatures between 300K and 400K. The result of this project is a sprayable Nafion film composite which resists ice nucleation at -20 °C for periods of greater than three hours. It is composed of Nafion polymer, hydrophilic polyethylene oxide polymer and CaCl2 anti-ice crosslinker. Durability and field performance properties remain to be determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field Testing of Self-Healing Metallic Coatings for Internal Corrosion Protection of Natural Gas Pipelines

Internal corrosion occurs in natural gas pipelines primarily due to the presence of water, carbon dioxide, and hydrogen sulfide. Internal corrosion can eventually result in leakage, cracks, and rupture of the pipeline. The objective of this work is to mitigate internal corrosion in steel pipelines transporting natural gas using cold spray coatings. The corrosion behavior of carbon steel coated with self-healing zinc chromium (ZnCr) and zinc niobium (ZnNb) cold spray coatings was investigated in a natural gas environment. For comparison purposes, hot-dip galvanized steel (HDGS) was tested under the same conditions as cold spray coatings. The field test was performed at the NW Natural gas storage facility in Mist, Oregon. The field test was conducted in a 6-inch diameter pipe transporting wet natural gas out of an underground storage well at 500 psi and 4.4 °C. The coupons were tested for 15 and 32 days under stagnant and flow conditions, respectively. Weight loss method was used to measure the corrosion rate of metallic coatings. Post-corrosion surface characterization was performed on the specimen using a scanning electron microscopy (SEM) equipped with energy dispersive X-ray spectroscopy (EDS). Crystalline phases were determined by X-ray diffraction (XRD). The field-test results confirmed that the metallic coatings provided corrosion protection of carbon steel exposed to wet natural gas under stagnant and flow conditions. The formation of the ZnCO 3 layer on top of ZnNb and ZnCr coatings led to passivation of the coatings which helps to reduce the self-corrosion. These layers form a barrier for diffusion of corrosive species to the surface.

03 NATURAL GAS↗

Enhanced Tritium Retention in LiAlO2 Pellets via Engineered Glazes: Tritium Science Project

This project investigated the impact of adding a thin (10 – 50 µm) layer of amorphous glaze to the surface of a TPBAR pellet on its retention of helium, hydrogen (as a surrogate for tritium), and water (as a surrogate for tritiated water). The hypothesis was that the glaze would significantly reduce permeation of hydrogen species with a lesser impact on hindering helium permeation. A non-crystallizing soda-lime-silicate glass, known as SCN-1, was selected for this proof-of-concept study. It was found that continuous glaze layers of the desired thickness could be applied to the pellets with two or more dip coats, depending on the targeted thickness. At 330°C, the glaze was found to have a permeability that was lower than that of the pellet by a factor of ~10 6 , implying that a thin 10 – 50 µm layer can significantly increase pellet retention of hydrogen. Meanwhile, the permeation rate of helium through the glaze was found to be ~20 times higher than that of hydrogen or water. An unanticipated outcome of the study was that unglazed pellets were measured to have hydrogen diffusivities that are a factor of ~105 greater than the diffusivity value used in the TPBAR COMSOL model to achieve observed tritium retention rates. When the higher measured diffusivity was substituted into the model and the model was run with all tritium species in the pellet in the form of T 2 O at a partial pressure of 20 Pa in equilibrium with LiOT, the resulting retention was 50% after 500 days.

36 MATERIALS SCIENCE↗

Experimental and Theoretical Evaluation of Feed Flow Collar Design for Shell Fed Hollow Fiber Membrane Modules

An experimental and theoretical study of module collar design is presented here. Hollow fiber membranes are prepared by dip coating a poly(vinylidene) (PVDF) support with a polydimethylsiloxane (PDMS) gutter layer and a Pebax 2533 selective layer. Fiber bundles with a well-defined fiber packing are prepared using a 3D printed module. A parallel fiber bundle consisting of 4-9 uniformly spaced fibers is created with printed tabs that align the fibers and create a tubesheet. The tabs are sealed within a printed case that possesses a series of external ports for gas introduction and removal. Uniquely, both port location and the use of a collar to assist fluid distribution in the shell can be varied for the same fiber bundle. Experimental measurements are compared to computational fluid dynamics (CFD) simulations. The experimental module design allows high-fidelity representation of the fiber bundle and module case in the simulations. Comparisons between experiment and simulation are in good agreement over a broad range of experimental conditions. The detrimental effect of having ports located too close, leading to stagnation regions, is captured as well as the beneficial effects of using a collar for shell-side fluid distribution around the fiber bundle. Such results help validate the use of CFD to develop high-performance module designs.

Tran, Thien↗

High Values of the Arctic Amplification in Early Decades of the 21st Century: Causes of Discrepancy by CMIP6 Models Between Observation and Simulation

Arctic Amplification (AA) in the first decade of the 21st century has reached values between 4 and 5, with a subsequent decrease to current values of about 3.6, while the value was from 2 to 3 during the twentieth century. The ensemble mean of the CMIP6 models has difficulty in reproducing the recently observed high values of the AA. In this report, we identify the main reason for this difficulty to be the CMIP6 models overestimate of the mean global temperature trend since about 1990. The largest values of the AA are observed in winter and spring. A sharp AA peak in 1987 spring was caused by a peak in the Arctic temperature trend occurring at the same time as a dip in the trend of mean global temperature. The winter AA has increased almost monotonically since 1990. Dividing the AA between the Arctic land and ocean areas shows that the ocean area makes a larger contribution to the AA. Our future projection of the AA suggests an increasing AA for about the next decade, followed by a slow decrease to about 3.5 in the 2050s.

54 ENVIRONMENTAL SCIENCES↗

Innovations in Direct Air Capture: Unveiling a Simple and Robust Synthesized Fibrous Amine-functionalized Matrix (FAM) Sorbent for Commercial Scale-up

The escalating challenge of climate change necessitates innovative solutions in the realm of carbon management, particularly in mitigating the impact of fossil fuel emissions. Direct Air Capture (DAC) technology emerged as a critical component within the spectrum of Carbon Capture and Sequestration (CCS) solutions, offering the distinct advantage of directly removing CO2 from the atmosphere irrespective of the source. This attribute grants DAC systems unparalleled flexibility in deployment locations and the potential to make substantial contributions to lowing atmospheric CO2 levels. The success of DAC technologies significantly depends on the development of an efficient, economical sorbent capable of selective and durable CO2 capture from ambient air. Recent advancements in material science have led to the exploration of amine-functionalized sorbents, hollow fiber sorbents and membranes, and other novel materials designed to meet these criteria. This study explores a novel Fibrous Amine-functionalized Matrix (FAM) sorbent. The FAM sorbent distinguished itself through its mechanical robustness, a streamlined synthesis process, and the capability for low-temperature regeneration (is 90 oC really low temperature?). FAM’s exceptional adsorption-desorption kinetics enable swift CO2 capture and release, crucial for the viability of DAC on a commercial scale. The synthesis process involves a simple dip-coating technique, allowing crosslinked amines to coat glass substrates.

Wang, Qiuming↗

AEOLIAN INTERDUNE FACIES OF THE NAVAJO SANDSTONE, UTAH

During the Early Jurassic an extensive desert environment covered a large area of the Western Interior of the USA. The Navajo Sandstone erg is thought to be one of the largest dunefields preserved in the rock record, estimated to have covered well over 500,000 km2, though the preserved extent is less due to erosion. The Navajo Sandstone outcrops extensively in eastern and southern Utah, forming spectacular domes and arches, including those in Arches National Park. Navajo Sandstone aeolian dunes consist of stacked, tabular sandstone bodies, displaying steeply dipping crossbedding, and are on average 15 m thick, with high porosity and permeability. In addition to these extensive paleodunes, interdune deposits are also documented, consisting of lensoid sandstone or pale grey limestone, of approximately 1-7 m thick. This research forms part of a broader investigation into the Navajo Sandstone in Utah, focusing on its potential as a CO2 reservoir. The internal stratigraphy of the Navajo Sandstone can be complex, with multiple types of aeolian surfaces present including discontinuous inter-dune contacts, and inclined bedding planes associated with large climbing dunes. Interdune deposits may be associated with more laterally extensive stratigraphic surfaces, highlighting their importance in the internal stratigraphic framework of the Navajo Sandstone erg. Here we interpret facies and depositional processes of aeolian interdune deposits of the Navajo Sandstone throughout Utah, using well log, outcrop, and thin sections. Interdune deposits range in type from short lived, small ponds of predominantly reworked aeolian sediment, to comparatively long-lived oases consisting of lakes with extensive ecosystems. This project aims to increase our understanding of an important potential CO2 reservoir, and enhance understanding of stratigraphic complexity within one of the world's most significant aeolian systems.

Mahon, Elizabeth (ORCID:0000000252692454)↗

Modeling 2p-2h Interactions in Neutrino-Nucleus Scattering: A Comparative Overview of the Valencia and SuSAv2-MEC Models

2p-2h interactions are crucial for describing ν-A scattering, especially in the "dip region" between the Quasi-Elastic (QE) peak and Δ-resonance production. They involve the ejection of two nucleons, leading to two holes in the nuclear ground state. The underlying nuclear dynamics involve short-range correlations (SRC), long-range correlations (Random Phase Approximation, RPA), and the interplay of one- and two-body currents. Several models attempt to describe 2p-2h interactions, including Microscopic Models (e.g., Valencia), Scaling-Based Models (e.g., SuSAv2-MEC), and Transport Models (e.g., GiBUU). Despite progress, discrepancies exist between models and with data. I Will give an overview of 2p2h from the perspective of two Models Valencia and SuSAv2-MEC.

Hassinin, Karim [Houston U.]↗

Salt Sampling FY21 Technical Report

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches to enable high-precision in-process salt sample analysis to improve the timeliness of sampling-based accountancy measurements. Tools currently under development in support of this goal include (1) a modular vacuum sampler with an accompanying sample handling method for coupling vacuum sampling with high-precision at-line sample analysis, (2) a pneumatic sample generator that enables high-throughput sample analysis to improve the precision of existing analytical techniques, and (3) a windowless flow cell to enable on-line optical analysis of molten salt in a sampling loop. Compared to point sampling approaches (i.e., dip probes), vacuum sampling systems and on-line sampling loops facilitate access to a larger cross-section of a process fluid. This is known to improve the characterization of the process fluid by producing more representative samples and by enabling the analysis of a larger cross section of the fluid. A vacuum sampling approach for molten salts eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. In FY21, two methods for integrating a vacuum sampler with a pneumatic sample generator were tested. These included direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the extreme conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampler and pneumatic sample generator, respectively. While the charging mechanism will be deployed in FY22, the tube transfer method and discharge mechanism were tested in FY21. These were deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The method was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques. This will enable significant reductions in the time delay for sampling-based accountancy measurements by eliminating the need for manual off-line sample processing and analysis. On-line optical analysis of molten salt in a sampling loop would provide complementary information to at-line and in-situ techniques. In FY21, an open-aperture molten salt gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the refinement and performance testing of the on-line and at-line sampling tools, integration of additional analysis techniques, stakeholder outreach and collaboration, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Deployment of salt sample extraction system at an engineering-scale electrorefiner

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness of sampling-based accountancy measurements. Two technologies under development in support of this goal are a vacuum sampling loop module and a high-throughput pneumatic sample generator module. Compared to traditional point sampling approaches (i.e., dip probes), the vacuum sampling loop facilitates the collection of a larger cross-section of the bulk salt in order to collect more representative samples. The vacuum sampling approach also eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. The pneumatic sample generator module is used to facilitate high-throughput sample analysis to improve the measurement precision of any given analytical technique by averaging out random sampling and measurement errors. In FY21, two methods for integrating these two modules were tested including direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampling loop and pneumatic sample generator modules, respectively. While the charging mechanism will be deployed in FY22, the discharge mechanism was tested in FY21 and is described here. The solid salt tube transfer method was deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The approach was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. To discharge salt from the sample tubes at the sampler generator, tube segments were inserted directly into the sample generator’s Helmholtz chamber and pressure pulse actuations were used to generate precision molten salt samples directly from the tube segments. The direct insertion of sample tubes into the sample generator enabled rapid loading of the salt and prevented salt from contacting most of the interior surfaces of the sample generator, which eliminated cross-contamination between runs. The vacuum sampling-loop tube charging mechanism will support high-throughput tube sampling operations by employing a dynamic vacuum filling process to fill short charge tubes that are configured to be rapidly connected and disconnected from the loop. The dynamic vacuum sampling operation will be automated, and sample tube handling can be executed with simple overhead actuation. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques which will enable significant reductions in the time delay for sampling-based high-precision accountancy measurements.

42 ENGINEERING↗

Utilizing the Quantum Zeno Effect in superconducting qubit based particle sensors

Superconducting qubit sensors are a compelling option for detecting faint signals from dark matter or low energy neutrino interactions. Improving their reach calls for both signal amplification and background suppression. The Quantum Zeno Effect (QZE)--which governs how entanglement reshapes a quantum system's time evolution--addresses both needs. By quantifying these modified time dynamics, we can better predict a qubit's response to a genuine particle event while suppressing coherence dips from other local disturbances. We present a new QZE-based protocol that could mitigate a dominant source of coherence fluctuations from Two Level Systems, show initial measurements of the QZE in superconducting qubits, and discuss additional opportunities where understanding and exploiting the effect are critical for building robust, high-sensitivity qubit detectors.

Seidel, Olivia [Fermilab]↗

MEC modeling

2p-2h interactions are crucial for describing ν-Ar scattering, especially in the "dip region" between the Quasi-Elastic (QE) peak and Δ-resonance production. They involve the ejection of two nucleons, leading to two holes in the nuclear ground state. The underlying nuclear dynamics involve short-range correlations (SRC), long-range correlations (Random Phase Approximation, RPA), and the interplay of one- and two-body currents. Several models attempt to describe 2p-2h interactions like Valencia and SuSAv2-MEC. Despite progress, discrepancies exist between models and with data. I Will give an overview of 2p2h from the perspective of two Models Valencia and SuSAv2-MEC. I will introduce my current work to apply reweighting from SuSAv2 to Valencia on argon which will help improving the systematic uncertainty on MEC for SBN and DUNE.

Hassinin, Karim [Houston U.] (ORCID:00090009778353↗

Studying the Impact of Momentary Cessation of IBRs Compliant With IEEE Std. 2800-2022 on Transmission Line Protection Elements

This paper examines the impact of inverter-based resource (IBR) momentary cessation timing on transmission system protection relays. IEEE Std. 2800 mandates voltage ride-through, requiring IBRs to remain online during voltage disturbances. However, for severe voltage dips (|V| = 0.1 p.u.), the standard permits current blocking. In practice, vendors implement momentary cessation with varying delays, potentially affecting relay operation if IBRs cease too early. This article studies the impact of the time IBRs enter momentary cessation on transmission line protective relays. Using an electromagnetic transient (EMT) simulation, this study models IBR momentary cessation with tunable delays in a realistic transmission network. COMTRADE files generated from EMT simulations are analyzed in MATLAB using detailed protective relay models. Results indicate that IBRs must sustain operation for at least one cycle to ensure proper relay response; otherwise, relays may fail to oper- ate. These findings guide IBR vendors in optimizing momentary cessation settings to enhance transmission line protection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Signals of a New Gauge Boson from IceCube and Muon g-2

Gauging the muon lepton flavor minus the tau lepton flavor number, which is a global symmetry of the SM, introduces a new gauge boson Z' upon symmetry breaking. Interestingly, it offers an economical solution to the long-standing g_µ-2 anomaly, confirmed and strengthened by recent measurements at Fermilab. Here, we revisit the impact of such a Z' on the spectrum of high-energy astrophysical neutrinos, as measured by the IceCube experiment. This spectrum has been observed to exhibit a dip-like feature at sub-PeV energies, which could plausibly arise from the physics of the sources themselves, but could also be the consequence of high-energy neutrinos resonantly scattering with the cosmic neutrino background, mediated by a Z' with a mass on the order of m_Z’ ~ 10 MeV. In this study, we calculate the impact of such a Z' on the high-energy neutrino spectrum for a variety of model parameters and source distributions. For couplings that can resolve the g-2 anomaly, we find that this model could self-consistently produce a spectral feature that is consistent with IceCube's measurement, in particular if the neutrinos observed by IceCube predominantly originate from high-redshift sources. We also briefly discuss a possible scenario where Z' could act as a portal to a dark sector.

79 ASTRONOMY AND ASTROPHYSICS↗

The propagation of seismic waves, misinformation, and disinformation from the 2024-10-05 M 4.5 Iran earthquake

The 2024-10-05 Iran M 4.5 earthquake took place at a time of heightened tensions in the Middle East. We perform a discrimination and moment tensor analysis and identify a shallow-dipping, reverse fault source commensurate with the compressional setting of the Iranian interior. Nonetheless, the event's aftermath saw widespread dissemination of misinformation, and potentially active disinformation, concluding that it was in fact a test of an Iranian nuclear weapon. The 'evidence' for many of these claims was based on inaccurate interpretation of seismic data. In this paper, we analyze how geophysical 'fake news' propagated through social media (mainly Twitter/X) following this event, eventually gaining traction in mainstream, earned media. This event is an illustrative warning of how seismic data can be misinterpreted and/or manipulated in public discourse.

58 GEOSCIENCES↗

Assessment of Weld Microstructure Through Sound Velocity Measurements for Power Plant Applications

Here, this research study employed an immersion-based micro-resolution ultrasonic velocity measurement technique (MUVT) to evaluate Grade 91 (9Cr-1Mo-V) steel welds. This process utilized a 20 MHz focused ultrasonic beam with a spot size of 250 µm, a 6 µm laser vibrometer spot size for detection, and an automated 3-axis raster scanner to accurately collect ultrasonic velocity data from two Grade 91 steel welds fabricated using cold metal transfer (CMT) and flux-cored arc welding (FCAW) processes. By analyzing the MUVT data, the Poisson’s ratio (υ) and modulus of elasticity (E), which are important mechanical properties for weldments, were calculated. The correlation between mechanical properties and ultrasonic velocity was examined. The results indicated that longitudinal ultrasonic velocity could effectively identify base metal, heat-affected zone (HAZ), and weld metal areas, showing a strong correlation with hardness. In particular, the distinctive V-shaped dip in velocity and hardness data across the HAZ areas of both samples highlighted changes in the microstructure of creep strength–enhanced ferritic steel welds. Importantly, the immersion-based MUVT demonstrated high accuracy in small sections of the weld, surpassing the conventional contact ultrasonic testing method in spatial resolution detection.

arc welding↗

Enhanced Bottom Anode Monitoring in DC Electric Arc Furnaces Using Fiber-Optic Sensors

A pin style bottom anode employs conductive steel rods that serve as the pathway for the high electrical power through rammed refractory at the bottom of a DC Electric Arc Furnace (EAF). Anode wear during operation is important to monitor, as anode replacement is expensive and impacts EAF productivity. Liquid steel penetration into the un-sintered refractory layer can result from rapid electrical power ramp-up, dips in furnace temperature, or operating the anode for too long between EAF campaigns. In extreme cases, the liquid steel may penetrate the bottom of the furnace when anode wear progresses too close to the bottom shell, which is extremely dangerous and must be avoided. The current state of the art for monitoring bottom anode wear employs thermocouples imbedded in the anode pins at points in the anode. However, this approach is not sensitive enough to detect localized damage to the anode, especially when cracking occurs. Here, the present work utilizes fiber optic sensors to monitor the health of the anode, by creating a real-time spatially distributed temperature map of the anode. Unlike the traditional thermocouples, these sensors can be mounted at significantly greater depths, provide distributed temperature measurements, and can withstand temperatures of up to 900°C. Additionally, they are able to perform temperature measurements with a spatial resolution of 1.3 mm at a 5 Hz acquisition rate, providing unprecedented high-density real time monitoring of anode health and increasing the efficiency, and safety of EAF operation.

Bottom Anode↗