Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Criticality Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by Lawrence Livermore National Laboratory (LLNL), with key participants from L’Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements were planned and executed. The primary aim of this research was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods.

Criticality↗

Estimating β eff from static, late-time Feynman neutron noise measurements

The effective delayed neutron fraction, β eff , is a kinematic parameter describing the contribution of delayed neutrons to the effective multiplication factor, $\kappa$ eff , and is of great interest to the nuclear criticality safety community and beyond. In fact, $\kappa$ eff presently must be inferred (as opposed to directly measured) since variables like β eff must be obtained from simulation, reference tables, or a dynamic or pulsed measurement where the assembly of fissile material is perturbed and not in steady state. Several recent works have proposed neutron noise techniques to estimate β eff from static measurements (such as benchmark experiments). This work experimentally investigates an approach based on looking at late-time (up to thousands of seconds) correlated neutrons in Feynman histograms. This work utilizes measurements of weapons grade plutonium and highly enriched uranium to construct late-time Feynman histograms and investigate a proposed methodology of estimating β eff from a fit of the distribution. Data is shown from both He-3 detectors and an organic scintillator array. This work is preliminary in nature, demonstrating some experimental feasibility and proposing improvements for future investigations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity-based Similarity Metrics for New Experiment Design Optimization

The nuclear data used in advanced reactor simulations requires validation. Data from nuclear criticality experiments can provide this validation. New nuclear criticality experiment design requires extensive knowledge and expert judgement such that the experimental design parameters are selected in such a way to keep the experiment subcritical. To aide in this experimental design process, professionals can utilize sensitivity and uncertainty analysis. Sensitivity and uncertainty analysis relies on matching new application experiments with currently existing benchmark experiments. Currently, there is functionality in the Whisper 1.1 software package to calculate a similarity metric based on neutron multiplication factor sensitivity coefficients between a new application designed by the user and existing International Criticality Safety Benchmark Experiment Project (ICSBEP) benchmarks. The Whisper 1.1 software package is included in Monte Carlo N-Particle ® Code Version 6.21 (MCNP ® 6.2). This work is geared toward expanding this capability to new similarity metrics based on beta-effective sensitivity coefficients and reactivity coefficient sensitivity coefficients. While the investigation of these sensitivity coefficients is presented in detail in separate works at this same conference, this work will be primarily focused on studying the similarity metrics in more detail. These similarity metrics will then be incorporated into the optimization algorithms used for experiment design in EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data), which is a Los Alamos National Laboratory (LANL) project designed to constrain nuclear data of interest, such that adjustments can be made to possible inaccuracies. A more detailed optimization can be subsequently performed by breaking down these similarity metrics by isotope, reaction, and energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

140,142 Ce Neutron Cross Section Resolved Resonance Region Evaluation [Abstract]

A resolved resonance region evaluation of 140,142 Ce has been carried out by Oak Ridge National Laboratory. Requested by the US Nuclear Criticality Safety Program, this evaluation is based on recent high-resolution transmission and capture high-resolution measurements of nat Ce and 142 Ce conducted at JRC-GEEL at the Geel Linear Accelerator facility, as well as recently measured thermal constants available from the EXFOR database. Starting from the resonance parameters from the ENDF/B-VIII.0 library and following a preliminary R-matrix analysis, an updated set of resonance parameters and corresponding covariance information was derived by the fit of these experimental datasets using the Reich-Moore approximation of the R-matrix theory as implemented in the SAMMY code system. The resolved resonance region upper energy limit for 140 Ce was kept at 200 keV while the 142 Ce resonance region was extended from 13 to 26 keV. This new evaluation was found to be in good agreement not only with several integral quantities of interest to the reactor physics community, but also with the stellar Maxwellian-averaged cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data Testing of Polyethylene Thermal Scattering Law with New Thermal Epithermal eXperiments (TEX) Plutonium Baseline Benchmark, PU-MET-MIXED-002

Five plutonium baseline experiments completed in September of 2018 from the Thermal Epithermal eXperiments (TEX) program have been accepted by the International Criticality Safety Benchmark Evaluation Project as PU-MET-MIXED-002 and will be included in the 2020 version of the handbook. The experiments were made up of stacked layers of plutonium Zero Power Physics Reactor (ZPPR) plates moderated by polyethylene (PE, chemical formula C2H4) to varying degrees to create configurations with five different neutron spectra, including one fast configuration, one thermal configuration, and three mixed configurations. Calculations of the benchmark show overprediction of k eff when using the most recent release of the Evaluated Nuclear Data File Version B (ENDF/B) library release (VIII.0) cross sections, particularly when compared to the previous ENDF/B-VII.1 results. One potential source of overprediction was hypothesized to be the new Molecular Dynamics (MD) generated PE Thermal Scattering Law (TSL). The overprediction was shown via calculation to not be caused by the new ENDF/B-VIII.0 thermal scattering law, and in fact the overprediction was mitigated by the new PE TSL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of SCALE Criticality and Sensitivity Calculations for Reflected HEU Cylinders

The SCALE code package offers multiple nuclear data libraries and sensitivity and uncertainty (S/U) methods supporting and derived from Monte Carlo (MC) transport. The CSAS and TSUNAMI-3D sequences use KENO MC, utilizing either continuous-energy (CE) cross sections or multigroup (MG) cross section libraries. TSUNAMI-3D has two CE calculational methods: the iterated fission probability (IFP) method, and the Contribution-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) method. Previous work has shown poor agreement between CLUTCH and confirmatory direct perturbation calculations in specific applications (e.g., fissionable and polyethylene reflectors). The HEU-MET-FAST-084 (HMF-084) International Criticality Safety Benchmark Evaluation Project evaluation consists of 27 cylindrical highly enriched uranium metal cores with 14 unique reflector materials of 0.5 and 1 in. thicknesses. Included in this list of reflector materials are natural uranium and polyethylene. This work utilized SCALE 6.2.4 models of the HMF-084 evaluation, with additional non-physical configurations to test both the MG bias and CLUTCH functionality across a variety of reflector material thicknesses. The evaluation’s use of concentric cylinders allowed for examination of several MG self-shielding methods: infinite homogenous, cylindrical, and spherical. The results indicate that the use of polyethylene reflectors with CLUTCH is not fundamentally impossible but sensitive to geometry. The poor performance of CLUTCH with fissionable reflectors was reaffirmed. The 2 in. and greater polyethylene-reflected calculations demonstrate the necessity of using the 302-group library for fast systems. The nickel MG bias was substantial, as discussed in a companion paper, as were cobalt and iron.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Future of the MUSiC Experiment Data

The Measurements of Uranium Subcritical and Critical (MUSiC) experiment was a highly enriched uranium (HEU) experiment performed at the National Criticality Experiments Research Center (NCERC) executed between December 2020 and April 2021. The experiment intended to measure criticality and reactor kinetics parameters in a bare HEU system. The experiment concurrently measured radiation signatures from the system while utilizing different neutron source types. This was an attempt to benchmark both detectors and analysis techniques against one another for identical measurements. The experiment consisted of the Rocky Flats HEU hemi-shells constructed into ten configurations spanning between deeply subcritical (about 14 kgs) to supercritical (about 60 kgs). Two of the ten configurations were supercritical and the other eight were subcritical. The two supercritical configurations, often referred to as the critical configurations, were documented into an International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmark evaluation and submitted to the technical review group (TRG). The subcritical configurations of the MUSiC experiment were examined using three different detection systems. The systems include: the NoMAD He-3 neutron detector which consists of 15 He-3 tubes surrounded by a polyethylene matrix, a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD), and a trans-stilbene organic scintillator array (OSCAR) provided by the University of Michigan. The NoMAD and RAM-RODD data are planned to be evaluated in two separate ICSBEP evaluations utilizing neutron noise methods such as Feynman Variance-to-Mean, Rossi-α and the pulsed neutron source method. Each of the subcritical configurations were examined using three different source types including: a Cf-252 source in the center, with only the intrinsic neutron source in the HEU, and with an external D-T neutron generator.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Chlorine Validation through Critical Integral Experiments

An increased interest in the validation of chlorine nuclear data, specifically 35Cl, in recent years has led to the prioritization of conducting chlorine critical experiments for nuclear data validation and criticality safety evaluations. A previous experiment was conducted with PVC and CPVC (chlorinated polyvinyl chloride) to reduce the margin of subcriticality for PF-4 operations with aqueous plutonium chloride solutions. Challenges in determining the composition of specific polymers, namely the CPVC, made it difficult to characterize, and therefore benchmark. Additional materials that were utilizable for chlorine validation were not immediately clear, as form, strength, purity, and composition are all important. A series of possible absorber materials were identified and studied, but ultimately granular sodium chloride was chosen. In addition to the needs of LANL’s PF-4 other industry collaborators have brought attention to the need for chlorine validation. Specifically, the need for HEU electrorefining with LiCl salts at Y-12 was taken into consideration for this experiment, with the experimental configurations being finely tuned to best meet their needs. Needs for validation were also presented by Idaho National Lab (INL) and TerraPower for validation of their Molten Chloride Reactor Experiment (MCRE) and Molten Chloride Fast Reactor (MCFR) and have also been considered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MCNP ® Code V.6.3.0 Release Notes

The Monte Carlo N-Particle ® (MCNP ® ) code is a general-purpose, continuous-energy, generalized geometry, time-dependent, radiation transport code developed by the MCNP development team. The MCNP calculations provide predictive capabilities that can replace expensive or impossible-to perform experiments. Specific application problems include simulations of experimental diagnostics, intrinsic radiation, radiation detection and measurement, criticality safety, nuclear threat reduction and response, radiation health protection, nuclear weapons effects, and nuclear forensics. This MCNP code, version 6.3.0, follows the MCNP6.2.0 version. Since the release of MCNP6.2.0, many changes have been made to the MCNP code. These changes include new or improved features, a new build system, code enhancement and modernization, and bug fixes. The MCNP code, version 6.3.0, theory and user input information is documented in MCNP ® Code Version 6.3.0 Theory & User Manual, the build guidance for various platforms is documented in MCNP ® Code Version 6.3.0 Build Guide, and the verification and validation testing for various application benchmark test suites is documented in MCNP ® Code Version 6.3.0 Verification & Validation Testing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

$\mathcal{R}$ -matrix analysis of η + nat Cl reactions relevant to molten-salt reactor designs [Abstract]

Performed with support from the U.S. Nuclear Criticality Safety Program in an effort to provide improved chlorine cross section and corresponding covariance data, the R-matrix analysis of neutron induced reactions for two stable chlorine isotopes, 35,37 Cl, was performed in the energy range of thermal up to 1.2 MeV. Starting from the repository of the ENDF/B-VIII.0 library and following recent measurement campaigns, this work represents a significant improvement in the evaluation of the ( η , p ) reaction channel. The evaluation methodology uses the $\mathcal{R}$ -matrix code SAMMY to generate a set of Reich-Moore resonance parameters. As predicted by recently measured 35 Cl( η , p ) data, the presented evaluation features a dramatic increase in the magnitude of the ( η , p ) reaction channel over the ENDF/B-VIII.0 and previous nuclear data ENDF/B released libraries. Together with details of the evaluation procedure, the impact of the updates in the outgoing proton emissions on reactivity coefficients for different molten-salt reactor designs is presented and discussed.

charged-particle↗

R-matrix Resolved Resonance Region Evaluation of 140,142 Ce

Oak Ridge National Laboratory completed the resolved resonance region (RRR) evaluation of the two most abundant cerium isotopes, 140 Ce (88.45%) and 142 Ce (11.11%), as requested by the US Nuclear Criticality Safety Program. These evaluations are based on recent high-resolution transmission and capture measurements performed on nat Ce and highly enriched 142 Ce samples at the JRC-Geel Linear Accelerator facility, as well as measured thermal constants available from the EXFOR database. Starting from the resonance parameters of the ENDF/B-VIII.0 library followed by a preliminary R-matrix analysis, an updated set of resonance parameters and corresponding covariance information were derived by fitting these measured data using the Reich–Moore approximation of the R -matrix theory, as implemented in the SAMMY code system. The 140 Ce RRR upper energy limit was kept at 200 keV, whereas the 142 Ce resonance region was extended from 13 to 26 keV. Updated statistical properties were obtained for the new evaluations and compared to those derived from the ENDF/B-VIII.0 nuclear data library. The new evaluation work improved some of the discrepancies found in previous work, such as the capture resonance integral and stellar Maxwellian-averaged cross sections. These integral quantities were mainly derived from the fit of the latest measured data, especially the neutron capture yield data for 142 Ce isotope.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Godiva IV Central Cavity Neutron Environment Characterization with Threshold Neutron Detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235 U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of Hydrogen Bonding on Nuclear Data Development of Liquid Anhydrous HF

Anhydrous Hydrogen Fluoride (HF) at high temperatures and pressures is used to process and manufacture nuclear fuel. As HF is often used directly with uranium, correct neutron thermal scattering cross sections are crucial to criticality safety applications. Classical molecular dynamics (CMD) simulation of the flexible HF system was used to create the thermal scattering law (TSL) and cross sections. The initial 2-site model is used in LAMMPS, and it can not capture the H-bond. To correctly represent the H-bond effects, a second, 3-site model was constructed in GROMACS. The 3-site model handled H-bonds by connecting a massless charge to the molecule. Key model parameters were compared to experimental data to verify the approach and models. To get the normalized VACF, the model was compared using hydrogen and fluorine bond length, density, potential energy, and diffusion coefficient. The phonon DOSs for both models were derived from the normalized VACF. DOSs were used to estimate the TSL ( S ( α, β )) and neutron thermal scattering cross sections for hydrogen in HF. The TSLs were evaluated using the FLASSH code with the Schofield diffusion model. It was observed that the representation of the hydrogen bonding changes the TSL's diffusional contributions. This is represented in the low energy scattering cross section, where intermolecular binding effects shift the cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verifying MCNP Models of the TEX High 240 Plutonium Benchmark

Computational modeling programs are invaluable tools that allow us to understand systems, safely develop new processes, and make reliable predictions about future designs. However, the effectiveness of these codes is limited by the degree to which their parameters match the real world. In the field of nuclear engineering, cross section data is one of these vital parameters. Accurate cross section data on important fissile and fissionable isotopes promotes the design of safer and more efficient fabrication, transportation, storage, and stockpiling of nuclear fuel. Unfortunately, there are knowledge gaps in data on key isotopes. In 2011, a multinational meeting hosted by the US Department of Energy Nuclear Criticality Safety Program ranked the priority of certain cross section data needs. In response, Lawrence Livermore National Lab (LLNL) designed the Thermal and Epithermal eXperiment (TEX) series of benchmark experiments. Benchmark experiments are used to validate current cross section data. They validate data by comparing the results of an actual experiment to the predicted results from a computational model. The data a benchmark applies to depends on the isotope and energy range the experiment’s neutron multiplication factor ( k eff ) is most sensitive to. The development and testing of the TEX High 240 Plutonium Benchmark will help validate 240 Pu cross section data. The configuration and materials of this benchmark are designed to be most sensitive to 240 Pu's intermediate energy range (from 0.625 ev to 100 keV ). MCNP® models of the assembly have been developed by LLNL and the results have been written in the final design report. In order for the discrepancies between benchmark models and experiments to be attributed to cross section inaccuracies, the accuracy of the models needs to be verified. The goal of this project is to verify of the results of LLNL's modeling by creating a new set of MCNP models and comparing the results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of ( n, γ ) cross section of 90 Zr [Abstract]

The isotopes of Zr with A = [90, 91, 92, 94] make up more than 97% of naturally occurring Zr and are important to many nuclear applications such as nuclear reactors. One of the attractive qualities of naturally occurring Zr isotopes is that they have a low σγ/σt ratio at most neutron energies, such that they improve the neutron economy in reactors by preferentially scattering neutrons rather than absorbing them. This same quality also presents a challenge to measuring the capture cross section, σγ, of Zr isotopes. The ENDF/B-VIII.0 library has a relative uncertainty of approximately 10-20% for incident neutron energies < 0.1 MeV, and uncertainty greater than 20% for energies > 0.1 MeV for the majority of natural Zr isotopes. This motivated the Nuclear Criticality Safety Program (NCSP) to embark on a campaign to accurately measure and evaluate these isotopes of Zr. Here we will show energy-dependent neutron capture cross section measurements for the first enriched sample to be measured: 90 Zr. The measurements of isotopically enriched samples are being carried out at the Geel Electron Linear Accelerator (GELINA) facility of the Joint Research Center - Geel (JRC-Geel) of the European Union. As isotopic enrichment is a costly process we are careful not to activate any of the samples, as this may hinder future radiation-sensitive measurements. The activation analysis is presented in a report by Brown et al.. Once we were satisfied that the Zr samples would not be activated by the measurements, the 90 Zr sample was fabricated at Oak Ridge National Laboratory (ORNL) and shipped to GELINA. The dimensions of the cylindrical sample are approximately 0.12 cm thick and a radius of 2.5 cm. Since 90 Zr is not chemically reactive to air, bare metallic samples were employed. The sample was measured at a flight path (FP) length of 60 m, using four C 6 D 6 detectors on FP14. The final paper will include experimental details and measured cross section data for 90 Zr compared to current evaluated nuclear data libraries.

07 ISOTOPE AND RADIATION SOURCES↗

Validation of the two-region Rossi-alpha model for reflected assemblies

Nuclear criticality safety, nonproliferation and safeguards, emergency response, and stockpile stewardship utilize estimates of the k eff multiplication factor. The value of k eff cannot be directly measured, but it can be inferred from the prompt neutron period. One modality of measuring the prompt neutron period is the Rossi-alpha method, which is predicated on fitting a histogram of detection time differences due to the nonrandom temporal distribution of same-fission-chain neutrons. Recent works have developed the motivation and theory to expand traditional one-region point kinetic models resulting in one-exponential histogram fits to two-region models that result in two-exponential fits. This paper validates the new two-region model using organic scintillator measurements of copper-reflected weapons-grade plutonium (0:83 ≤ k eff ≤ 0:94) and high-density- polyethylene-reflected highly enriched uranium (0:73 ≤ k eff ≤ 0:95). Furthermore, the results show that more thermal systems have shorter prompt neutron periods in the core region due to increased induced-fission probabilities for moderated neutrons. Here, a new parameter introduced by the two- region model is also shown to be correlated to the amount of reflection, and may be used to infer assembly properties such as type and amount of reflector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗