Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Extended fine structures in the electron energy loss spectrum of InAs

The possibility of using electron energy loss fine structure (EELFS) for the characterization of thin pseudomorphic quantum wells of InAs and GaAs(100) is investigated. It is shown that the EELFS technique can yield reliable radial distribution functions for bulk InAs, provided beam-induced sample degradation is controlled stringently. Additional improvements in the data collection procedures, including better control of the sample condition, are required as well as more detailed work on separating contributions from multiple edges in the data analysis.

Schowengerdt, F. D.↗

FE Simulation of SMA Seal for Mars Sample Return

Several NASA rovers and landers have been on Mars and performed successful in-situ exploration. Returning Martian samples to Earth for extensive analysis is of great interest to the planetary science community. Current Mars sample return architecture would require leaving the acquired samples on Mars for years before being retrieved by subsequent mission. Each sample would be sealed securely to keep its integrity. A reliable seal technique that does not affect the integrity of the samples and uses a simple low-mass tool is required. The shape memory alloy (SMA) seal technique is a promising candidate. A study of the thermal performances of several primary designs of a SMA seal for sample tubes by finite element (FE) simulation are presented in this paper. The results show sealing the sample tube by SMA plugs and controlling the sample temperature below the allowed temperature level are feasible.

seal↗

More Than a Decade of International Space Station Microbial Sampling in the Environmental Control and Life Support Systems

Microbial monitoring has taken place in major units belonging to the Environmental Control and Life Support Systems (ECLSS) of the International Space Station (ISS). For at least a decade multiple modules including US and RU segments were sampled. In the US ECLSS, water reclamation and air systems combine their microbial contents downstream where biofilm incidents have been recorded. Understanding the microbial contents of segments provides a longitudinal perspective to microbiome changes in the system that contribute to this issue. The US ECLSS have been consistently sampled, especially in the Potable Water Bus (PWB) where bacteria from upstream sources have been observed.

Yo-Ann Velez Justiniano↗

More Than a Decade of International Space Station Microbial Sampling in the Environmental Control and Life Support Systems

Microbial monitoring has taken place in major units belonging to the Environmental Control and Life Support Systems (ECLSS) of the International Space Station (ISS). For at least a decade multiple modules including US and RU segments were sampled. In the US ECLSS, water reclamation and air systems combine their microbial contents downstream where biofilm incidents have been recorded. Understanding the microbial contents of segments provides a longitudinal perspective to microbiome changes in the system that contribute to this issue. The US ECLSS have been consistently sampled, especially in the Potable Water Bus (PWB) where bacteria from upstream sources have been observed.

Yo-Ann Velez Justiniano↗

Analysis of Tank 38H (HTF-38-23-95, -96) and Tank 43H (HTF-43-23-93, -94) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory analyzed samples from Tank 38H and Tank 43H to support Enrichment Control Program (ECP) and Corrosion Control Program (CCP). The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased significantly from the previous Tank 38H surface sample. The current Tank 38H subsurface sample shows similar Na, free hydroxide, and anions versus the previous subsurface sample. However, the 38H subsurface sample shows higher concentrations of Al, Ca, Fe, Mn, and Si vs. the previous Tank 38H subsurface sample. The current Tank 38H subsurface sample contained visible sludge solids in excess of the previous sample based on visual appearance. Weight percent solids measurements indicate presence of 3.0 ± 0.1 wt.% insoluble solids in the Tank 38H subsurface sample. The significant differences in the concentrations of major components between the Tank 38H surface and subsurface samples indicate significant stratification of solution species between these two locations within the Tank 38H. Savannah River Mission Completion (SRMC) personnel indicated that there were no tank-to-tank transfers into Tank 38H since early January 2023 and the 2H (16H) Evaporator was shut down on 3/26/2023 and has not operated since that time. There have been many pumped non-waste transfers of water from the H-Area diversion box 7 (HDB-7) sump into Tank 38 since the 3/26/2023 date.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of TMT Labeling Efficiency in Large-Scale Quantitative Proteomics: The Critical Effect of Sample pH

Isobaric labeling via tandem mass tag (TMT) reagents enables sample multiplexing prior to LC–MS/MS, facilitating high-throughput large-scale quantitative proteomics. Consistent and efficient labeling reactions are essential to achieve robust quantification; therefore, embedded in our clinical proteomic protocol is a quality control (QC) sample that contains a small aliquot from each sample within a TMT set, referred to as “Mixing QC.” This Mixing QC enables the detection of TMT labeling issues by LC–MS/MS before combining the full samples to allow for salvaging of poor TMT labeling reactions. While TMT labeling is a valuable tool, factors leading to poor reactions are not fully studied. We observed that relabeling does not necessarily rescue TMT reactions and that peptide samples sometimes remained acidic after resuspending in 50 mM HEPES buffer (pH 8.5), which coincided with low labeling efficiency (LE) and relatively low median reporter ion intensities (MRIIs). To obtain a more resilient TMT labeling procedure, we investigated LE, reporter ion missingness, the ratio of mean TMT set MRII to individual channel MRII, and the distribution of log 2 reporter ion ratios of Mixing QC samples. We discovered that sample pH is a critical factor in LE, and increasing the buffer concentration in poorly labeled samples before relabeling resulted in the successful rescue of TMT labeling reactions. Moreover, resuspending peptides in 500 mM HEPES buffer for TMT labeling resulted in consistently higher LE and lower missing data. By better controlling the sample pH for labeling and implementing multiple methods for assessing labeling quality before combining samples, we demonstrate that robust TMT labeling for large-scale quantitative studies is achievable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of nonlinear discrete-time controllers using a parameter space sampling procedure

The design of nonlinear discrete-time controllers is investigated where the control algorithm assumes a special form. State-dependent control actions are obtained from tables whose values are the design parameters. A new design methodology capable of dealing with nonlinear systems containing parameter uncertainty is used to obtain the controller design. Various controller strategies are presented and illustrated through an example.

Young, G. E.↗

Analysis of Tank 38H (HTF-38-24-53, -56) and Tank 43H (HTF-43-24-54, -55) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory analyzed samples from Tank 38H and Tank 43H to support the Enrichment Control Program (ECP) and Corrosion Control Program (CCP). The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased from the previous Tank 38H surface sample. The current Tank 38H subsurface sample shows similar Na, free hydroxide, and anions in comparison to the previous subsurface sample. However, the 38H subsurface sample shows lower concentrations of Al, Ca, Fe, Mn, and Si in comparison to the previous Tank 38H subsurface sample. Measurement of the wt.% insoluble solids in the Tank 38H subsurface sample and associated uncertainty analysis indicates that the calculated average wt.% insoluble solids is 0.45 ± 0.75 wt.%. Significant differences in the concentrations of major components between the Tank 38H surface and subsurface samples indicate significant stratification of solution species between these two locations within Tank 38H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Design of Robotic Control Software for Mars Sample Return - Capture, Containment, and Return System

The Mars Sample Return (MSR) campaign aims to acquire and return to Earth a set of Mars samples for investigation in terrestrial laboratories. Mars 2020 has collected an adequate number of samples and deposited them in sealed sample tubes at a designated Martian depot. Sample tubes will be placed in cylindrical containers called Orbiting Samples (OS) by the Perseverance Rover, and later brought to Earth by the Earth Return Orbiter (ERO) and the MSR - Capture, Containment, and Return System (CCRS). Robot Software (RSW) is a set of software processes for commanding and monitoring the avionics that controls robotic mechanisms designed to sterilize and install OS into Earth Entry System (EES) for return to Earth. This paper describes a preliminary design of RSW including motion modes, architecture, and finite state machine. Additionally, software engineering procedures and testing of RSW is provided. A preliminary performance analysis is presented and the paper concludes with future work and a discussion of design decisions.

MSR↗

Controlled freezing of biological samples

Apparatus consists of thermocouple connected to semiconductor reference junction. Junction is connected to amplifier that boosts signal by 1,000. High-level signal is displayed on recorder and fed into second amplifier where it is compared with signal from potentiometer of programmed dc reference in bag-temperature programer. Difference in signals indicates output voltage. Remaining circuitry provides zero-phase, time-proportion control of heaters such that heater power is directly proportional to error signal.

Cygnarowicz, T. A.↗

Repair and Utilization of the Kratos XSAM 800 X-Ray Photoelectron Spectrometer (XPS)

The objectives for this summer faculty fellowship were first to repair the Kratos XSAM 800 X-ray Photoelectron Spectrometer (XPS) and then to utilize the instrument to participate in ongoing research projects at KSC and in the researcher's own laboratory at UCF. The first 6 weeks were used in repairing the instrument. Working both alone and with the Kratos service engineer, a number of hardware problems, largely associated with the sample stage control system, were corrected. Defective parts were identified and fixed in the computer driver boards, the stage power supply, and the driver interface. The power supply was completely replaced. After four weeks of work, the instrument was functional. This occurred on a Wednesday. The following Friday the instrument had to be completely shut down because the power to the O & C Building was to be turned off. The instrument was properly secured. On Monday, the instrument was powered up and the original problems returned. After another 2 weeks of work, a software problem was identified. This problem caused the computer to use a defective port for the sample stage control. It was circumvented by rewriting the startup routine. The final 3 weeks of the fellowship were spent using the XPS to analyze samples being studied in the Langley materials project (Martha Williams) and a catalyst project (Dr. Orlando Melendez). During this time, several sample analysis requests from other groups at KSC also came in and those samples were run as well. The summer faculty fellowship also allowed many contacts to be made. After meeting with the sensors group, two projects were identified for collaboration and white papers are being prepared. One project aims to develop small, very sensitive hydrogen detectors and the other to develop a broad area, easily monitored, zero power consumption hydrogen detector. In addition to the work mentioned above, the XPS was utilized in a study underway in Dr. Hampton's laboratory at UCF.

Hampton, Michael D.↗

Sample Delivery and Computer Control Systems for Detecting Leaks in the Main Engines of the Space Shuttle

The main engines of the Space Shuttle use hydrogen and oxygen as the fuel and oxidant. The explosive and fire hazards associated with these two components pose a serious danger to personnel and equipment. Therefore prior to use the main engines undergo extensive leak tests. Instead of using hazardous gases there tests utilize helium as the tracer element. This results in a need to monitor helium in the ppm level continuously for hours. The major challenge in developing such a low level gas monitor is the sample delivery system. This paper discuss a system developed to meet the requirements while also being mobile. Also shown is the calibration technique, stability, and accuracy results for the system.

Griffin, Timothy P.↗

Optimal regulation in systems with stochastic time sampling

An optimal control theory that accounts for stochastic variable time sampling in a distributed microprocessor based flight control system is presented. The theory is developed by using a linear process model for the airplane dynamics and the information distribution process is modeled as a variable time increment process where, at the time that information is supplied to the control effectors, the control effectors know the time of the next information update only in a stochastic sense. An optimal control problem is formulated and solved for the control law that minimizes the expected value of a quadratic cost function. The optimal cost obtained with a variable time increment Markov information update process where the control effectors know only the past information update intervals and the Markov transition mechanism is almost identical to that obtained with a known and uniform information update interval.

Montgomery, R. C.↗

Experimental measurement of the plasma conductivity of Z93 and Z93P thermal control paint

Two samples each of Z93 and Z93P thermal control paint were exposed to a simulated space environment in a plasma chamber. The samples were biased through a series of voltages ranging from -200 volts to +300 volts and electron and ion currents measured. By comparing the currents to those of pure metal samples of the same size and shape, the conductivity of the samples was calculated. Measured conductivity was dependent on the bias potential in all cases. For Z93P, conductivity was approximately constant over much of the bias range and we find a value of 0.5 micro-mhos per square meter for both electron and ion current. For Z93, the dependence on bias was much more pronounced but conductivity can be said to be approximately one order of magnitude larger. In addition to presenting these results, this report documents all of the experimental data as well as the statistical analyses performed.

Hillard, G. Barry↗

Deep reinforcement learning with online data augmentation to improve sample efficiency for intelligent HVAC control

Deep Reinforcement Learning (DRL) has started showing success in real-world applications such as building energy optimization. Much of the research in this space utilized simulated environments to train RL-agent in an offline mode. Very few research have used DRL-based control in real-world systems due to two main reasons: 1) sample efficiency challenge---DRL approaches need to perform a lot of interactions with the environment to collect sufficient experiences to learn from, which is difficult in real systems, and 2) comfort or safety related constraints---user's comfort must never or at least rarely be violated. In this work, we propose a novel deep Reinforcement Learning framework with online Data Augmentation (RLDA) to address the sample efficiency challenge of real-world RL. We used a time series Generative Adversarial Network (TimeGAN) architecture as a data generator. We further evaluated the proposed RLDA framework using a case study of an intelligent HVAC control. With a ≈28% improvement in the sample efficiency, RLDA framework lays the way towards increased adoption of DRL-based intelligent control in real-world building energy management systems.

Kurte, Kuldeep↗

Analysis of Tank 38H (HTF-38-25-36, -32) and Tank 43H (HTF-43-25-33, -35) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory (SRNL) analyzed samples from Tank 38H and Tank 43H to support the Enrichment Control Program (ECP) and Corrosion Control Program (CCP). The results indicate the concentrations of most soluble species in the Tank 38H surface sample are similar to the previous Tank 38H surface sample. The current Tank 38H subsurface sample shows similar Na, free hydroxide, and anions in comparison to the previous subsurface sample. The current Tank 38H subsurface sample appears brown in color. Measurement of the wt.% insoluble solids in the Tank 38H subsurface sample and associated uncertainty analysis indicates that the calculated average wt.% insoluble solids is 5.5 ± 3.6 wt.%. Significant differences in the concentrations of major components between the Tank 38H surface and subsurface samples indicate stratification of solution species between these two locations within the Tank 38H. The current Tank 43H surface sample is ~ 10% diluted versus the previous Tank 43H surface sample and the Tank 43H subsurface sample is similar in composition to the previous Tank 43H subsurface sample. Information provided by SRMC on tank additions since the last ECP sampling indicates that a total of about 4,062 gallons of water was added to Tank 43H. This addition could account for the observed relatively small dilution of ~ 10% in the Tank 43H surface sample. Similar solution compositions measured in the current Tank 43H surface and subsurface samples indicate a minimal stratification within the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗