Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Conditional Normalizing Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Investigation of Operating Characteristics of an Engine Equipped with Modifications to Eliminate Fuel-Evaporation Icing

Two modified fuel-injection systems, a drilled-inducer type and a spinner type, that prevent serious fuel-evaporation icing were installed on a V-type, liquid-cooled aircraft engine and a preliminary investigation was conducted to determine the effect on engine operating characteristics. The spinner system was also ground - and flight tested on a twin-engine fighter airplane. Flight measurements of cylinder-head temperature over a range of fuel-air ratios and engine power conditions were made at an altitude of approximately 10,000 feet. Starting and accelerating of the engine on the ground were unaffected by the fuel-injection modifications. During the flight investigation, no appreciable variation occurred between the maximum and minimum cylinder-head temperature with the standard and modified system for the same power condition and no irregularity of mixture distribution could be detected throughout the power range of the engine. Normal mixture distribution was also indicated by a similar response of cylinder-head temperature for variations of fuel-air ratio at manifold pressures of 25 and 35 inches of mercury absolute. Both modified fuel-injection systems required less fuel-nozzle pressure than the standard system to obtain the desired fuel-air ratio for given air-flow condition.

Mulholland, Donald R.↗

Review of the Scientific Understanding of Radioactive Waste at the U.S. DOE Hanford Site

This paper reviews the origin and chemical and rheological complexity of radioactive waste at the U.S. Department of Energy’s Hanford Site. The waste, stored in underground tanks, was generated via three distinct processes over decades of plutonium extraction operations. Although close records were kept of original waste disposition, tank-to-tank transfers and conditions that impede equilibrium complicate our understanding of the chemistry, phase composition, and rheology of the waste. Tank waste slurries comprise particles and aggregates from nano to micron scales, with varying densities, morphologies, heterogeneous compositions, and complicated responses to flow regimes and process conditions. Further, remnant or changing radiation fields may affect the stability and rheology of the waste. These conditions pose challenges for transport through conduits or pipes to treatment plants for vitrification. Additionally, recalcitrant boehmite degrades glass quality and must be reduced prior to vitrification, but dissolves much more slowly than predicted given surface normalized rates. Existing empirical models based on ex situ experiments and observations lack true predictive capabilities. Recent advances in in situ microscopy, aberration corrected TEM, theoretical modeling across scales, and experimental methods for probing the physics and chemistry at mineral-fluid and mineral-mineral interfaces are being implemented to build robustly predictive physics-based models.

Environmental Molecular Sciences Laboratory↗

Implementation of In-Situ Impedance Techniques on a Full Scale Aero-Engine System

Determination of acoustic liner impedance for jet engine applications remains a challenge for the designer. Although suitable models have been developed that take account of source amplitude and the local flow environment experienced by the liner, experimental validation of these models has been difficult. This is primarily due to the inability of researchers to faithfully mimic the environment in jet engine nacelles in the laboratory. An in-situ measurement technique, one that can be implemented in an actual engine, is desirable so an accurate impedance can be determined for future modeling and quality control. This paper documents the implementation of such a local acoustic impedance measurement technique that is used under controlled laboratory conditions as well as on full scale turbine engine liner test article. The objective for these series of in-situ measurements is to substantiate treatment design, provide understanding of flow effects on installed liner performance, and provide modeling input for fan noise propagation computations. A series of acoustic liner evaluation tests are performed that includes normal incidence tube, grazing incidence tube, and finally testing on a full scale engine on a static test stand. Lab tests were intended to provide insight and guidance for accurately measuring the impedance of the liner housed in the inlet of a Honeywell Tech7000 turbofan. Results have shown that one can acquire very reasonable liner impedance data for a full scale engine under realistic test conditions. Furthermore, higher fidelity results can be obtained by using a three-microphone coherence technique that can enhance signal-to-noise ratio at high engine power settings. This research has also confirmed the limitations of this particular type of in-situ measurement. This is most evident in the installation of instrumentation and its effect on what is being measured.

Gaeta, R. J.↗

One-way nesting for a primitive equation ocean model

Prognostic numerical models for atmospheric and oceanic circulations require initial fields, boundary conditions, and forcing functions in addition to a consistent set of partial differential equations, including a state relation and equations expressing conservation of mass, momentum, and energy. Depending on the horizontal domain to be modeled, the horizontal boundary conditions are either physically obvious or extremely difficult to specify consistently. If the entire atmosphere is modeled, periodic horizontal boundary conditions are appropriate. On the other hand, the physical horizontal boundaries on the entire ocean are solid walls. Obviously, the normal velocity at a solid wall is zero while the specification of the tangential velocity depends on the mathematical treatment of the horizontal viscous terms. Limitations imposed by computer capacity and cost, as well as research interests, have led to the use of limited area models to study flows in the atmosphere and ocean. The limited area models do not have physical horizontal boundaries, merely numerical ones. Correctly determining these open boundary conditions for limited-area numerical models has both intrigued and frustrated numerical modelers for decades. One common approach is to use the closed or solid wall boundary conditions for a limited-area model. The argument given for this approach is that the boundary conditions affect flow near the walls but that none of these effects are propagated into the interior. Therefore, one chooses a big enough domain that the central region of interest is not corrupted by the boundary flow. Research in progress to model the North Atlantic circulation vividly illustrates the pitfalls of this approach. Two model runs are compared: (1) the southern boundary at 20S between latitudes 0 and 40W is artificially closed; and (2) the same boundary is specified as open with an inward transport of 15 Sv (determined from a global model with the same physics) uniformly spread across the boundary. A comparison of both runs is presented.

Blake, D. W.↗

In-flight leading-edge extension vortex flow-field survey measurements on a F-18 aircraft at high angle of attack

Flow-field measurements on the leading-edge extension (LEX) of the F-18 High Alpha Research Vehicle (HARV) were obtained using a rotating rake with 16 hemispherical-tipped five-hole probes. Detailed pressure, velocity, and flow direction data were obtained through the LEX vortex core. Data were gathered during 1-g quasi-stabilized flight conditions at angles of attack alpha from 10 degrees to 52 degrees and at Reynolds numbers based on mean aerodynamic cord up to 16 x 10(exp 6). Normalized dynamic pressures and crossflow velocities clearly showed the primary vortex above the LEX and formation of a secondary vortex at higher angles of attack. The vortex was characterized by a ring of high dynamic pressure surrounding a region of low dynamic pressure at the vortex core center. The vortex core, subcore diameter, and vertical location of the core above the LEX increased with angle of attack. Minimum values for static pressure were obtained in the vortex subcore and decreased nearly linearly with increasing angle of attack until vortex breakdown. Rake-measured static pressures were consistent with previously documented surface pressures and showed good agreement with flow visualization flight test results. Comparison of the LEX vortex flight test data to computational solutions at alpha approximately equals 19 degrees and 30 degrees showed fair correlation.

David M Richwine↗

Propulsion Aeroelastic Analysis Developed for Flutter and Forced Response

The NASA Glenn Research Center at Lewis Field develops new technologies to increase the fuel efficiency of aircraft engines, improve the safety of engine operation, reduce emissions, and reduce engine noise. With the development of new designs for fans, compressors, and turbines to achieve these goals, the basic aeroelastic requirements are that there should be no flutter (self-excited vibrations) or high resonant blade stresses (due to forced response) in the operating regime. Therefore, an accurate prediction and analysis capability is required to verify the aeroelastic soundness of the designs. Such a three-dimensional viscous propulsion aeroelastic analysis capability has been developed at Glenn with support from the Advanced Subsonic Technology (AST) program. This newly developed aeroelastic analysis capability is based on TURBO, a threedimensional unsteady aerodynamic Reynolds-averaged Navier-Stokes turbomachinery code developed previously under a grant from Glenn. TURBO can model the viscous flow effects that play an important role in certain aeroelastic problems such as flutter with flow separation, flutter at high loading conditions near the stall line (stall flutter), flutter in the presence of shock and boundary-layer interaction, and forced response due to wakes and shock impingement. In aeroelastic analysis, the structural dynamics representation of the blades is based on normal modes. A finite-element analysis code is used to calculate these in-vacuum vibration modes and the associated natural frequencies. In an aeroelastic analysis using the TURBO code, flutter and forced response are modeled as being uncoupled. To calculate if a blade row will flutter, one prescribes the motion of the blade to be a harmonic vibration in a specified in-vacuum normal mode. An aeroelastic analysis preprocessor is used to generate the displacement field required for the analysis. The work done by aerodynamic forces on the vibrating blade during a cycle of vibration is calculated. If this work is positive, the blade is dynamically unstable, since it will extract energy from the flow, leading to an increase in the blade s oscillation amplitude. The forced-response excitations on a blade row are calculated by modeling the flow through two adjacent blade rows using the TURBO code. The blades are assumed to be rigid. As an option, a single blade row can be modeled with the upstream blade row influence represented by a time-varying disturbance (gust) at the inlet boundary. The unsteady forces on a blade row from such analyses are used in a structural analysis along with the blade structural dynamics characteristics and aerodynamic damping associated with blade vibration to calculate the resulting dynamic stresses on the blade.

Bakhle, Milind A.↗

Improving air leakage prediction of buildings using the fan pressurization method with the Weighted Line of Organic Correlation

In many countries, the fan pressurization method is the most frequently chosen approach for measuring the air leakage of houses. The measurements are usually performed at pressures that far exceed pressures to which buildings are exposed to under normal conditions. A fit of these tests to the power-law formulation allows an extrapolation to data points outside the measured pressure range. With the Ordinary Least Square (OLS) fitting method, the pressure exponent and flow coefficient can be determined. However, the measurement results are highly sensitive to uncertainties induced by external factors like changing wind conditions during the tests, which is neglected by OLS. This may lead to errors in the prediction of flows at lower pressures. The Weighted Line of Organic Correlation (WLOC) is an alternative approach and takes measurement uncertainty into account. In this paper, a statistical analysis of an extensive data set of pressurization measurements has been performed. Both regression techniques have been compared for almost 7500 fan pressurization measurements of six houses in 109 different house leak configurations. The variability in predicting pressure exponent and flow coefficient for both WLOC and OLS regression was analyzed using probability density functions. It was found that the Weighted Line of Organic Correlation significantly decreases the uncertainty in predicting pressure exponent, flow coefficient, and other low-pressure air leakage metrics compared to the Ordinary Least Square fitting. Here, the authors highly recommend the implementation of WLOC in current measurement standards and test equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurements in ducted flows by laser-Doppler anemometry

The merits of small-scale, water-flow experiments with measurements by laser-Doppler anemometry are indicated in relation to previously reported results. New measurements are reported in a square-to-round transition duct and show that, for example, the pressure forces overwhelm any small normal-stress driven secondary flows in the inlet plane to given maximum values of around 0.07 of the bulk velocity in the exit plane. The precision of manufacture of the ducts means that the geometric boundary conditions are accurately known and the results are therefore suitable for calculation purposes. Similarly, the instrumentation allows the flow boundary conditions to be accurately determined.

Taylor, A. M. K. P.↗

Magnetized thermal conduction fronts

The evolution of planar thermal conduction fronts in the presence of a dynamically weak, but otherwise self-consistent, magnetic field is considered. The field is assumed to be connected and untangled. In the diffusion limit for the thermal conductivity, these fronts exhibit self-similar behavior, even in the presence of a field. The role of the field is restricted to channeling the heat flux along its lines of force, and it enters into the problem as a dimensionless angle variable. 'Combing' (or opening) of insulating field lines by the evaporative flow is explicitly demonstrated. Unless the field is nearly perpendicular to the front normal in the hot gas, insulating effects are not profound. Self-similarity breaks down if the front becomes saturated, and under certain conditions magnetized saturated conduction fronts cannot propagate: the solution characteristics of the wave equation form caustics. The physical resolution is the advent of two-fluid (nonlocal) heating. Such Coulomb-heated fronts are expected to be relatively rare in typical astrophysical systems. The large-scale effects of a magnetic field on cloud evaporation in the interstellar medium are briefly discussed, and it is suggested that these fields preclude the presence of time-independent evaporative solutions. Thermal interfaces may then continue to evolve until radiative cooling halts their development; large tracts of warm 10,000 K gas may result.

Balbus, S. A.↗

Kinetic structure of slow shocks - Effects of the electromagnetic ion/ion cyclotron instability

The structure of slow magnetosonic shocks in the low beta regime is analyzed with attention given to ion heating and the effects of waves upstream of the electromagnetic ion/ion cyclotron (EMIIC) instability. Shock formation is assessed by means of three methods - a relaxation method and two based on dynamic flow interactions - to determine the effects of initialization and boundary conditions on the formation. Good solutions are found with the piston method and the similar flow-flow method in which the plasma is injected from two boundaries to form two slow shocks. Plasma parameters and shock normal angle are found to be the key variables dictating the structure of the magnetosonic shocks. Four unique classes of resultant shock structures are described in which classical, steady, or nonsteady behavior is found. The analysis also yields insight into the relationship between EMIIC instability and ion dissipation.

Omidi, N.↗

Fluid Creep Effects on Near-Wall Solute Transport for Non-Isothermal Ampoules

There is a growing practical and theoretical interest in developing accurate macroscopic modelling for flows arising in chemical or physical vapor transport (VT) crystal growth experiments, including those conducted in reduced gravity environments. Rosner was the first person to point out that previously neglected rarefield gas dynamics phenomena (Stefan and bouyancy-driven flows) become rather important sources of convection. In particular, the combination of rarefaction and strong gradients of temperature (and/or concentration) tangential to the side-walls of the ampoule induces convective flows known as thermal (and concentration) 'creep' respectively. His order-of-magnitude estimates revealed that thermal creep effects can be non-negligible even at normal gravitational levels. On the macroscopic level, the bulk fluid mechanics can be adequately described by the familiar macroscopic equations as long as the boundary conditions are modified to account for the integrated effect of kinetic boundary layers adjacent to solid boundaries. Motivated by the growing importance of these phenomena, we have embarked on a series of computational studies to elucidate these fundamental creep-induced effects for a rarefied gas in simple, two-dimensional confined geometries. However, unlike previous related studies, we resort to a microscopic description of the gas, mathematically expressed by the Boltzmann integro-differential equation. We employ the direct simulation Monte Carlo (DSMC) method of Bird, the theoretical foundations and several practical applications. In the case of thermally induced flows, the no-time counter method of Bird is used, as implemented for a hard-sphere gas. The scheme has been also extended to account for realistic molecular interaction models, an extension necessary if the diffusion physics underlying concentration creep are to be captured.

Papadopoulos, Dimitrios↗

Unsteady subsonic compressible flow around finite thickness wings.

A general formulation for the unsteady subsonic compressible potential flow around aircraft having arbitrary configurations is presented. An integral representation of the velocity potential is obtained. From this a linear integral equation relating the perturbation potential and its normal derivative (which is known from the boundary conditions) is derived. For the numerical solution of the integral equation, the surface of the aircraft is divided into small elements and the potential is assumed to be constant within each element. Numerical results are obtained for an oscillating finite-thickness wing and indicate good convergence and excellent agreement with existing lifting surface solutions.

Morino, L.↗

Determination of boundary shape of cooled porous region

The shape of a cooled porous wall section is found that will provide a uniform surface temperature, as dictated by material limitations, when the surface is subjected to spatially nonuniform heating. In the analysis, local temperatures and pressures in the porous material are expressed in terms of a potential function. From the imposed thermal conditions, this potential function is governed by the dual constraints of both its value and its normal derivative being specified along the heated surface. The unknown shape of this surface is obtained by meeting these dual conditions. The analytical method uses a generalized conformal mapping procedure that includes a curved boundary. The coolant flow can be compressible or incompressible, and its viscosity can depend on temperature.

Snyder, A.↗

Investigation of the validity of Reynolds averaged turbulence models at the frequencies that occur in turbomachinery

Turbulent flows subjected to various kinds of unsteady disturbances were simulated using a large-eddy-simulation computer code for flow in a channel. The disturbances were: a normal velocity expressed as a traveling wave on one wall of the channel; staggered blowing and suction distributions on the opposite walls of the channel; and oscillations of the mean flow through the channel. The wall boundary conditions were designed to simulate the effects of wakes of a stator stage passing through a rotor channel in a turbine. The oscillating flow simulated the effects of a pressure pulse moving over the rotor blade boundary layer. The objective of the simulations was to provide better understanding of the effects of time-dependent disturbances on the turbulence of a boundary layer and of the underlying physical phenomena regarding the basic interaction between the turbulence and external disturbances of the type found in turbomachinery. Results showed that turbulence is sensitive to certain ranges of frequencies of disturbances. However, no direct connection was found between the frequency of imposed disturbances and characteristic burst frequency of turbulence. New insight into the nature of turbulence at high frequencies was found. The viscous phenomena near solid walls was found to be the dominant influence for high frequency perturbations. At high frequencies, the turbulence was found to be undisturbed, remaining the same as for the steady mean flow. A transition range exists between the high frequency range and the low, or quasi-steady, range in which the turbulence is not predictable by either quasi-steady models or the steady flow model. The limiting lowest frequency for use of the steady flow turbulence model is that for which the viscous Stokes layer based on the blade passing frequency is thicker than the laminar sublayer.

Kuhn, Gary D.↗

Studies of two phase flow

The development of instrumentation for the support of research in two-phase flow in simulated microgravity conditions was performed. The funds were expended in the development of a technique for characterizing the motion and size distribution of small liquid droplets dispersed in a flowing gas. Phenomena like this occur in both microgravity and normal earth gravity situations inside of conduits that are carrying liquid-vapor mixtures at high flow rates. Some effort to develop a conductance probe for the measurement of liquid film thickness was also expended.

Witte, Larry C.↗

Estimation of the Unsteady Aerodynamic Load on Space Shuttle External Tank Protuberances from a Component Wind Tunnel Test

At the wake of the Columbia (STS-107) accident it was decided to remove the Protuberance Aerodynamic Load (PAL) Ramp that was originally intended to protect various protuberances outside of the Space Shuttle External Tank from high buffet load induced by cross-flows at transonic speed. In order to establish the buffet load without the PAL ramp, a wind tunnel test was conducted where segments of the protuberances were instrumented with dynamic pressure transducers; and power-spectra of sectional lift and drag forces at various span-wise locations between two adjacent support brackets were measured under different cross flow angles, Mach number and other conditions. Additionally, frequency-dependent spatial correlations between the sectional forces were also established. The sectional forces were then adjusted by the correlation length to establish span-averaged spectra of normal and lateral forces that can be suitably "added" to various other unsteady forces encountered by the protuberance. This paper describes the methodology used for calculating the correlation-adjusted power spectrum of the buffet load. A second part of the paper describes wind-tunnel results on the difference in the buffet load on the protuberances with and without the PAL ramp. In general when the ramp height is the same as that of the protuberance height, such as that found on the liquid Oxygen part of the tank, the ramp is found to cause significant reduction of the unsteady aerodynamic load. However, on the liquid Hydrogen part of the tank, where the Oxygen feed-line is far larger in diameter than the height of the PAL ramp, little protection is found to be available to all but the Cable Tray.

Panda, J.↗

Estimation of the Unsteady Aerodynamic Load on Space Shuttle External Tank Protuberances from a Component Wind Tunnel Test

At the wake of the Columbia (STS-107) accident it was decided to remove the Protuberance Aerodynamic Load (PAL) Ramp that was originally intended to protect various protuberances outside of the Space Shuttle External Tank from high buffet load induced by cross-flows at transonic speed. In order to establish the buffet load without the PAL ramp, a wind tunnel test was conducted where segments of the protuberances were instrumented with dynamic pressure transducers; and power-spectra of sectional lift and drag forces at various span-wise locations between two adjacent support brackets were measured under different cross flow angles, Mach number and other conditions. Additionally, frequency-dependent spatial correlations between the sectional forces were also established. The sectional forces were then adjusted by the correlation length to establish span-averaged spectra of normal and lateral forces that can be suitably "added" to various other unsteady forces encountered by the protuberance. This paper describes the methodology used for calculating the correlation-adjusted power spectrum of the buffet load. A second part of the paper describes wind-tunnel results on the difference in the buffet load on the protuberances with and without the PAL ramp. In general when the ramp height is the same as that of the protuberance height, such as that found on the liquid Oxygen part of the tank, the ramp is found to cause significant reduction of the unsteady aerodynamic load. However, on the liquid Hydrogen part of the tank, where the Oxygen feed-line is far larger in diameter than the height of the PAL ramp, little protection is found to be available to all but the Cable Tray.

Panda, Jayatana↗

Slip and Dilation Tendency Analysis of the Tuscarora Geothermal Area

Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an indication of which faults or fault segments within a geothermal system are critically stressed and therefore likely to transmit geothermal fluids. The slip tendency of a surface is defined by the ratio of shear stress to normal stress on that surface: Ts = T / on (Morris et al., 1996). Dilation tendency is defined by the stress acting normal to a given surface: Td = (o1-on) / (o1-o3) (Ferrill et al., 1999). Slip and dilation were calculated using 3DStress (Southwest Research Institute). Slip and dilation tendency are both unitless ratios of the resolved stresses applied to the fault plane by ambient stress conditions. Values range from a maximum of 1, a fault plane ideally oriented to slip or dilate under ambient stress conditions to zero, a fault plane with no potential to slip or dilate. Slip and dilation tendency values were calculated for each fault in the focus study areas at, McGinness Hills, Neal Hot Springs, Patua, Salt Wells, San Emidio, and Tuscarora on fault traces. As dip is not well constrained or unknown for many faults mapped in within these we made these calculations using the dip for each fault that would yield the maximum slip tendency or dilation tendency. As such, these results should be viewed as maximum tendency of each fault to slip or dilate. The resulting along-fault and fault-to-fault variation in slip or dilation potential is a proxy for along fault and fault-to-fault variation in fluid flow conduit potential. Stress Magnitudes and directions Stress field variation within each focus area was approximated based on regional published data and the world stress database (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2010; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012; Moeck et al., 2010; Moos and Ronne, 2010 and Reinecker et al., 2005) as well as local stress information if applicable. For faults within these focus systems we applied either a normal faulting stress regime where the vertical stress (sv) is larger than the maximum horizontal stress (shmax) which is larger than the minimum horizontal stress (sv>shmax>shmin) or strike-slip faulting stress regime where the maximum horizontal stress (shmax) is larger than the vertical stress (sv) which is larger than the minimum horizontal stress (shmax >sv>shmin) depending on the general tectonic province of the system. Based on visual inspection of the limited stress magnitude data in the Great Basin we used magnitudes such that shmin/shmax = .527 and shmin/sv= .46, which are consistent with complete and partial stress field determinations from Desert Peak, Coso, the Fallon area and Dixie valley (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2011; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012). Slip and dilation tendency for the Tuscarora geothermal field was calculated based on the faults mapped Tuscarora area (Dering, 2013). The Tuscarora area lies in the Basin and Range Province, as such we applied a normal faulting stress regime to the Tuscarora area faults, with a minimum horizontal stress direction oriented 115, based on inspection of local and regional stress determinations, as explained above. Under these stress conditions north-northeast striking, steeply dipping fault segments have the highest dilation tendency, while north-northeast striking 60 degrees dipping fault segments have the highest tendency to slip. Tuscarora is defined by a left-step in a major north- to-north northeast striking, west-dipping range-bounding normal fault system. Faults within the broad step define an anticlinal accommodation ...

15 GEOTHERMAL ENERGY↗