Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Production of Diesel Engine Turbocharger Turbine from Low Cost Titanium Powder

Turbochargers in commercial turbo-diesel engines are multi-material systems where usually the compressor rotor is made of aluminum or titanium based material and the turbine rotor is made of either a nickel based superalloy or titanium, designed to operate under the harsh exhaust gas conditions. The use of cast titanium in the turbine section has been used by Cummins Turbo Technologies since 1997. Having the benefit of a lower mass than the superalloy based turbines; higher turbine speeds in a more compact design can be achieved with titanium. In an effort to improve the cost model, and develop an industrial supply of titanium componentry that is more stable than the traditional aerospace based supply chain, the Contractor has developed component manufacturing schemes that use economical Armstrong titanium and titanium alloy powders and MgR-HDH powders. Those manufacturing schemes can be applied to compressor and turbine rotor components for diesel engine applications with the potential of providing a reliable supply of titanium componentry with a cost and performance advantage over cast titanium.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Roots Air Management System with Integrated Expander

PEM fuel cells remain an emerging technology in the vehicle market with several cost and reliability challenges that must be overcome in order to increase market penetration and acceptance. The DOE has identified the lack of a cost effective, reliable, and efficient air supply system that meets the operational requirements of a pressurized PEM 80kW fuel cell as one of the major technological barriers that must be overcome. This project leveraged Roots positive displacement development advancements and demonstrated an efficient and low cost fuel cell air management system. Eaton built upon its P-Series Roots positive displacement design and shifted the peak efficiency making it ideal for use on an 80kW PEM stack. Advantages to this solution include: • Lower speed of the Roots device eliminates complex air bearings present on other systems. • Broad efficiency map of Roots based systems provides an overall higher drive cycle fuel economy. • Core Roots technology has been developed and validated for other transportation applications. Eaton modified their novel R340 Twin Vortices Series (TVS) Roots-type supercharger for this application. The TVS delivers more power and better fuel economy in a smaller package as compared to other supercharger technologies. By properly matching the helix angle with the rotor’s physical aspect ratio, the supercharger’s peak efficiency can be moved to the operating range where it is most beneficial for the application. The compressor was designed to meet the 90 g/s flow at a pressure ratio of 2.5, similar in design to the P-Series 340. A net shape plastic expander housing with integrated motor and compressor was developed to significantly reduce the cost of the system. This integrated design reduced part count by incorporating an overhung expander and motor rotors into the design such that only four bearings and two shafts were utilized.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of the LSC microbunching instability in MaRIE linac reference design

In this report we estimate the effect of the microbunching instability in the MaRIE XFEL linac. The reference design for the linac is described in a separate report. The parameters of the L1, L2, and L3 linacs as well as BC1 and BC2 bunch compressors were the same as in the referenced report. The beam dynamics was assumed to be linear along the accelerator (which is a reasonable assumption for estimating the effect of the microbunching instability). The parameters of the bunch also match the parameters described in the referenced report. Additionally, it was assumed that the beam radius is equal to R = 100 m and does not change along linac. This assumption needs to be revisited at later studies. The beam dynamics during acceleration was accounted in the matrix formalism using a Matlab code. The input parameters for the linacs are: RF peak gradient, RF frequency, RF phase, linac length, and initial beam energy. The energy gain and the imposed chirp are calculated based on the RF parameters self-consistently. The bunch compressors are accounted in the matrix formalism as well. Each chicane is characterized by the beam energy and the R56 matrix element. It was confirmed that the linac and beam parameters described previously provide two-stage bunch compression with compression ratios of 10 and 20 resulting in the bunch of 3kA peak current.

43 PARTICLE ACCELERATORS↗

Hydrogen Component Performance Diagnostic Testing (CRADA CRD-18-743 Final Report)

H2@Scale is focused on the wide scale adoption of hydrogen as a flexible energy storage medium. Due to the low volumetric energy density of gaseous hydrogen, compressors are an essential component of hydrogen storage. Hydrogen compressors that support a flexible grid and on-demand vehicle fueling undergo challenging operating conditions, such as a high number of start and stop cycles and wide input and discharge pressure ranges. Equally robust components are required for these conditions while still meeting the financial requirements of sustainable hydrogen compression.

08 HYDROGEN↗

Micro-Environmental Control System (Final Report)

This project developed an innovative micro-environmental control system (µX) that enables office buildings to reduce energy used for heating and cooling by 15% or more. The µX is a compact, quiet, and ergonomic device that is designed to be installed under an office workstation; it is designed to maintain occupant comfort when room thermostat setpoints are incremented by 4°F or more (warmer in the summer and cooler in the winter) to save energy. When ambient room temperatures are outside of the usual comfort range, the µX maintains occupant comfort by delivering personalized cooling or heating locally to each office worker. The µX provides personalized cooling using a micro vapor compression system that includes a new high-performance micro-scroll compressor and a novel thermal storage unit. The vapor compression system operates at night to freeze a phase-change material (PCM). During the workday, the cooling stored in the PCM is released as a cool breeze of air to make occupants more comfortable. The micro-scroll compressor was developed specifically for this application; it is smaller than any of its type, minimizing the amount of power needed. In heating mode, the µX maintains occupant comfort using a foot heating mat with an infrared reflective box. The µX R&D project was conducted by Syracuse University in collaboration with United Technologies Research Center, Air Innovations, Bush Technical, and Cornell University. Over the course of the initial three-year project, the team developed and evaluated four versions of the unit, advancing the concept to Technology Readiness Level 6. The capabilities of individual proof-of-concept prototypes were verified in tests that were conducted with: 1) units in psychrometric chambers, 2) an instrumented manikin in a laboratory, and 3) human subjects in laboratories that simulate office environments. The tests verified that the µX prototypes met or exceeded all performance targets required to enable office buildings to reduce energy used for heating and cooling by 15% or more by maintaining occupant comfort when thermostat setpoints are incremented by 4°F or more.

25 ENERGY STORAGE↗

Enabling CO 2 Isothermal Compression Using Liquid Piston and Integrated Gas Cooler

This report outlines the development of a near-isothermal liquid piston compressor. Initially, a proof-of-concept experiment was conducted to validate the feasibility and potential of near-isothermal compression. A first-of-its-kind near-isothermal liquid piston compressor was then successfully built and tested. Additionally, a Matlab-based transient model was developed to capture performance trends accurately. These efforts laid the groundwork for developing a second-generation prototype with enhanced efficiency and design. Subsequent field tests at the Helix Innovation Center in Ohio demonstrated a cooling capacity of 2 kW with a COP of 1.64 at an ambient temperature of 25°C. An improved model was also created to suggest different heat exchanger geometries for better compression efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Local Dynamic Reactive Power for Correction of System Voltage Problems

Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results are also provided and discussed. The simulations and testing show that local voltage control from DER can prevent local voltage collapse. The results also show that the control can be provided so quickly, within 0.5 seconds, that is does not interfere with conventional utility methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NDA SYSTEM RESPONSE MODELING AND ITS APPLICATION

The Portsmouth gaseous diffusion plant (PORTS) is a uranium enrichment facility that was historically used to enrich uranium to levels that range from 2% to greater than 97%. The feed material for PORTS was obtained from the Paducah Gaseous Diffusion Plant (PGDP) that produced uranium in the form of UF6 that was enriched to about 1 to 2%. The enrichment process involves a multistage process by which gaseous UF{sub 6} passed through a diffusion barrier in each stage. The porous diffusion barrier in each stage retards the rate of the diffusion of the heavier {sup 238}U atoms relative to the diffusion of the lighter {sup 235}U atoms. By this process the product stream is slightly enriched by each stage of the process. Each stage consists of a compressor, converter and a motor. There are more than 4000 stages that are linked together with piping of various diameters to form the PORTS cascade. The cascade spans three interconnected buildings and comprises miles of piping, thousands of seals, converters, valves, motors, and compressors. During operation, PORTS process equipment contained UF{sub 6} gas with uranium enrichment that increased in the process stream from the first to the last stage in a known manner. Gaseous UF{sub 6} moving through the PORTS process equipment had potential to form deposits within the process equipment by several mechanisms, including solidification due to incorrect temperature and pressure conditions during the process, inleakage of atmospheric moisture that chemically reacts with UF{sub 6} to form hydrated uranyl fluoride solids, reduction reactions of UF{sub 6} with cascade metals, and UF{sub 6} condensation on the internal equipment surfaces. As a result, the process equipment of the PORTS contains a variable and unknown quantity of uranium with variable enrichment that has been deposited within the equipment during plant operations. The exact chemical form of this uranium is variable, although it is expected that the bulk of the material is of the form of uranyl fluoride that will become hydrated on exposure to moisture in air when the systems are no longer buffered. The deposit geometry and thickness is uncertain and variable. However, a reasonable assessment of the level of material holdup in this equipment is necessary to support decommissioning efforts. The assessment of nuclear material holdup in process equipment is a complex process that requires integration of process knowledge, nondestructive assay (NDA) measurements, and computer modeling to maximize capabilities and minimize uncertainty. The current report is focused on the use of computer modeling and simulation of NDA measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Addendum to Third Supplemental Cultural Resources Review for the Infrastructure Cleanup on ALE, Hanford Site, HCRC# 2008-600-004D: Documentation of No Adverse Effect from Filling Two Cisterns at the National Register-Eligible Archaeological Site 45BN01032

The Third Supplemental Cultural Resources Review for the Infrastructure Cleanup on the Fitzner/Eberhardt Arid Lands Ecology Reserve, 600 Area, Hanford Site, Benton County, Washington, HCRC#2008-600-004D completed by the Pacific Northwest National Laboratory (PNNL) Cultural Resources Project (CRP) for the U.S. Department of Energy, Richland Operations Office (DOE-RL) identified a National Register-eligible archaeological site 45BN01032, the historic Rattlesnake Hills Gas Field Compressor Station. The compressor station was the core of the Rattlesnake Hills Field gas distribution system which was in operation from 1929 until 1941. Within the industrial component of this site are two large rectangular concrete cisterns that were used for water storage, both located on the southeastern boundary of the site.The original remediation proposed by DOE-RL at this site was to remove t-posts, placed around both cisterns at some point after the gas field was abandoned. This undertaking was addressed in the Third Supplemental Cultural Resources Review for the Infrastructure Cleanup on the Fitzner/Eberhardt Arid Lands Ecology Reserve, 600 Area, Hanford Site, Benton County, Washington, HCRC#2008-600-004D where a recommendation of no adverse effect to 45BN01032 was made because the t-posts are not contributing components of the site. Subsequent to the initial finding of No Adverse Effect, DOE-RL now proposes to fill these two cisterns with basalt rubble for health and safety reasons. This document outlines measures that will allow the two cisterns to be filled with no adverse effects to site 45BN01032.

Arid Lands Ecology Reserve↗

Modeling the Operation of Bulk-Action Hybrid Piston Power Systems

The operation of a bulk-action hybrid piston power unit is described by a mathematical model based on the laws of energy, mass, and momentum conservation and the equation of state. The influence of the pressure in the pump and compressor sections, the gap in the compressor section, and the eccentricity on the relation between the opposing liquid flow rates through the piston seal and on the thickness of the liquid layer above the piston is analyzed.

42 ENGINEERING↗

Generation of Coherent X-Ray Radiation Through Modulation Compression

In this letter, we propose a scheme to generate tunable coherent X-ray radiation for future light source applications. This scheme uses an energy chirped electron beam, a laser modulators, a laser chirper and two bunch compressors to generate a prebunched kilo-Ampere current electron beam from a few tens Ampere electron beam out of a linac. The initial modulation energy wavelength can be compressed by a factor of 1 + h{sub b}R{sub 56}{sup a} phase space, where h{sub b} is the energy bunch length chirp introduced by the laser chirper, R{sub 56}{sup a} is the momentum compaction factor of the first bunch compressor. As an illustration, we present an example to generate more than 400 MW, 170 atto-seconds pulse, 1 nm coherent X-ray radiation using a 60 Ampere electron beam out. of the linac and 200 nm laser seed. Both the final wavelength and the radiation pulse length in the proposed scheme are tunable by adjusting the compression factor and the laser parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam Dynamics Study of X-Band Linac Driven X-Ray FELS

Several linac driven X-ray Free Electron Lasers (XFELs) are being developed to provide high brightness photon beams with very short, tunable wavelengths. In this paper, three XFEL configurations are proposed that achieve LCLS-like performance using X-band linac drivers. These linacs are more versatile, efficient and compact than ones using S-band or C-band rf technology. For each of the designs, the overall accelerator layout and the shaping of the bunch longitudinal phase space are described briefly. During the last 40 years, the photon wavelengths from linac driven FELs have been pushed shorter by increasing the electron beam energy and adopting shorter period undulators. Recently, the wavelengths have reached the X-ray range, with FLASH (Free-Electron Laser in Hamburg) and LCLS (Linac Coherent Light Source) successfully providing users with soft and hard X-rays, respectively. FLASH uses a 1.2 GeV L-band (1.3 GHz) superconducting linac driver and can deliver 10-70 fs FWHM long photon pulses in a wavelength range of 44 nm to 4.1 nm. LCLS uses the last third of the SLAC 3 km S-band (2.856 GHz) normal-conducting linac to produce 3.5 GeV to 15 GeV bunches to generate soft and hard X-rays with good spatial coherence at wavelengths from 2.2 nm to 0.12 nm. Newer XFELs (at Spring8 and PSI) use C-band (5.7 GHz) normal-conducting linac drivers, which can sustain higher acceleration gradients, and hence shorten the linac length, and are more efficient at converting rf energy to bunch energy. The X-band (11.4 GHz) rf technology developed for NLC/GLC offers even higher gradients and efficiencies, and the shorter rf wavelength allows more versatility in longitudinal bunch phase space compression and manipulation. In the following sections, three different configurations of X-band linac driven XFELs are described that operate from 6 to 14 GeV. The first (LOW CHARGE DESIGN) has an electron bunch charge of only 10 pC; the second (OPTICS LINEARIZATION DESIGN) is based on optics linearization of the longitudinal phase space in the first stage bunch compressor and can operate with either a high (250 pC) or low (20 pC) bunch charge; and the third (LCLS INJECTOR DESIGN) is similar to LCLS but uses an X-band linac after the first stage bunch compressor at 250 MeV to achieve a final beam energy up to 14 GeV. Compared with LCLS, these X-band linacs are at least a factor of three shorter.

43 PARTICLE ACCELERATORS↗

UNDERSTANDING METHANE EMISSIONS SOURCES AND VIABLE MITIGATION MEASURES IN THE NATURAL GAS TRANSMISSION SYSTEMS: RUSSIAN AND U.S. EXPERIENCE

This article will compare the natural gas transmission systems in the U.S. and Russia and review experience with methane mitigation technologies in the two countries. Russia and the United States (U.S.) are the world's largest consumers and producers of natural gas, and consequently, have some of the largest natural gas infrastructure. This paper compares the natural gas transmission systems in Russia and the U.S., their methane emissions and experiences in implementing methane mitigation technologies. Given the scale of the two systems, many international oil and natural gas companies have expressed interest in better understanding the methane emission volumes and trends as well as the methane mitigation options. This paper compares the two transmission systems and documents experiences in Russia and the U.S. in implementing technologies and programs for methane mitigation. The systems are inherently different. For instance, while the U.S. natural gas transmission system is represented by many companies, which operate pipelines with various characteristics, in Russia predominately one company, Gazprom, operates the gas transmission system. However, companies in both countries found that reducing methane emissions can be feasible and profitable. Examples of technologies in use include replacing wet seals with dry seals, implementing Directed Inspection and Maintenance (DI&M) programs, performing pipeline pump-down, applying composite wrap for non-leaking pipeline defects and installing low-bleed pneumatics. The research methodology for this paper involved a review of information on methane emissions trends and mitigation measures, analytical and statistical data collection; accumulation and analysis of operational data on compressor seals and other emission sources; and analysis of technologies used in both countries to mitigate methane emissions in the transmission sector. Operators of natural gas transmission systems have many options to reduce natural gas losses. Depending on the value of gas, simple, low-cost measures, such as adjusting leaking equipment components, or larger-scale measures, such as installing dry seals on compressors, can be applied.

03 NATURAL GAS↗

Generation of Coherent X-Ray Radiation through Modulation Compression

In this paper, we propose a scheme to generate tunable coherent X-ray radiation for future light source applications. This scheme uses an energy chirped electron beam, a laser modulator, a laser chirper and two bunch compressors to generate a prebunched kilo-Ampere current electron beam from a few tens Ampere electron beam out of a linac. The initial modulation energy wavelength can be compressed by a factor of 1 + h{sub b}R{sub 56}{sup a} in phase space, where h{sub b} is the energy bunch length chirp introduced by the laser chirper, R{sub 56}{sup a} is the momentum compaction factor of the first bunch compressor. As an illustration, we present an example to generate more than 400 MW, 170 attoseconds pulse, 1 nm coherent X-ray radiation using a 60 A electron beam out of the linac and 200 nm laser seed. Both the final wavelength and the radiation pulse length in the proposed scheme are tunable by adjusting the compression factor and the laser parameters.

43 PARTICLE ACCELERATORS↗

Design of bunch compressing system with suppression of coherent synchrotron radiation for ATF upgrade

One of the operation modes for Accelerator Test Facility (ATF) upgrade is to provide high peak current, high quality electron beam for users. Such operation requires a bunch compressing system with a very large compression ratio. The CSR originating from the strong compressors generally could greatly degrade the quality of the electron beam. In this paper, we present our design for the entire bunch compressing system that will limit the effect of CSR on the e-beam’s quality. We discuss and detail the performance from the start to end simulation of such a compressor for ATF.

43 PARTICLE ACCELERATORS↗

Grid Adaptive Harmonic Adsorption Recuperative Power and Cooling System

We introduce a new non-condensing thermodynamic cycle that uses the chemical adsorption affinity of new nanostructured porous materials in a thermal compressor that eliminates the evaporator, condenser, and high pressure pump in the standard ORC to produce 40% more power from the same temperature heat source and can switch modes to cooling if required. This CCHP system is driven by low-grade heat (T<150 oC) and can operate in ambient temperatures over 40 oC. There is great interest in extracting economic benefit from the vast quantity of low and mid-grade heat rejected to the environment from primary energy conversion sources. In the U.S., this amounts to approximately 59 quads of wasted thermal energy. Geothermal resources at temperatures between 100 and 200 °C represent an additional very large (100 GWth) and widely geographically dispersed resource. Solar PV panels convert the majority of the incident solar radiation to heat as well. The principal reason why these thermal resources are not more fully exploited is cost. Low grade heat sources have modest exergy that can be turned into useful work. This means that standard power generation equipment, heat exchangers, expanders, pumps, etc. are significantly larger for the amount of power generated and efficiency of standard thermodynamic cycles such as the Rankine cycle are inherently low, less than 10% typically. The resulting high capital and operating costs relative to the amount of revenue that can be generated from power sales is rarely very economically attractive, especially today with low costs for natural gas. Hence there is a pressing need for new concepts that can dramatically bend the cost curve of power production from low grade heat sources. In this presentation, we describe a new non-condensing thermal compression cycle that offers potential for transformational improvements in cost and efficiency as compared with standard ORC systems. Although the thermal compressor described herein can be used for cooling, the focus here will be power generation.

adsorption, MOF, thermal compressor, geothermal, s↗

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗

HTTR-GT/H2 test plant - design study on helium gas turbine for the heat utilization system connected to JAEA's HTTR - 18674

In JAEA (Japan Atomic Energy Agency), the program of verification of combined system with helium gas turbine power generation and hydrogen production using nuclear heat which becomes the first in the world, is proceeding. From 2014 to 2015 Japanese Fiscal Year, the design study of the heat utilization system which is arranged in cascade to the heat supply system to supply the hydrogen production system and helium gas turbine system which are installed in the secondary helium-cooling system of High Temperature Engineering Test Reactor (HTTR) was performed and measure technologies of the system have been verified. MHI participated in the design study work of main equipment of this system. This paper reports the result of the design study of a helium gas turbine among those results. Self-sustaining condition (a power generation output is attained) is required for the gas turbine system in three modes of operation such as a) gas turbine individual operation, b) gas turbine + hydrogen production system combined operation, and c) hydrogen production system load loss and gas turbine independent shift operation]. By adopting a multi-stage centrifugal type impeller as a gas turbine and a compressor as a result of design study, it confirmed that all the mode-of-operation self-sustaining can be attained, and can attain a maximum of approx. 1 MWe power generation output on condition of the turbine inlet temperature of 560 deg. C, the turbine flow of 9.8 kg/sec, the compressor inlet temperature of 30 deg. C, and the compression ratio 1.3. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗