Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Application and evaluation of a pattern-based building energy model calibration method using public building datasets

Building performance simulation has been adopted to support decision making in the building life cycle. An essential issue is to ensure a building energy simulation model can capture the reality and complexity of buildings and their systems in both the static characteristics and dynamic operations. Building energy model calibration is a technique that takes various types of measured performance data (e.g., energy use) and tunes key model parameters to match the simulated results with the actual measurements. This study performed an application and evaluation of an automated pattern-based calibration method on commercial building models that were generated based on characteristics of real buildings. A public building dataset that includes high-level building attributes (e.g., building type, vintage, total floor area, number of stories, zip code) of 111 buildings in San Francisco, California, USA, was used to generate building models in EnergyPlus. Monthly level energy use calibrations were then conducted by comparing building model results against the actual buildings' monthly electricity and natural gas consumption. The results showed 57 out of 111 buildings were successfully calibrated against actual buildings, while the remaining buildings showed opportunities for future calibration improvements. Enhancements to the pattern-based model calibration method are identified to expand its use for: (1) central heating, ventilation and air conditioning (HVAC) systems with chillers, (2) space heating and hot water heating with electricity sources, (3) mixed-use building types, and (4) partially occupied buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using discrete Bayesian networks for diagnosing and isolating cross-level faults in HVAC systems

Fault detection and diagnosis (FDD) technologies are critical to ensure satisfactory building performance, such as reducing energy wastes and negative impacts on occupant comfort and productivity. Existing FDD technologies mainly focus on component-level FDD solutions, which could lead to mis-diagnosis of cross-level faults in heating, ventilating, and air-conditioning (HVAC) systems. Cross-level faults are those faults that occur in one component or subsystem, but cause operational abnormalities in other components or subsystems, and result in a building level performance degradation. How to effectively diagnose the root cause of a cross-level fault is the focus of this study. Here, this paper presents a novel discrete Bayesian Network (DisBN)-based method for diagnosing cross-level faults in an HVAC system commonly used in commercial buildings. A two-level DisBN structure model is developed in this study. The parameters used in the DisBN model are obtained either from expert knowledge or through machine-learning strategies from normal system operation data. Meanwhile, the probability parameters are discretized to incorporate the uncertainties associated with typical expert knowledge. Thus, the developed DisBN method addresses the challenges many other BN based FDD methods face, i.e., the lack of fault data for BN parameter training. The developed DisBN represents causal relationships between a fault and its cross-level system impacts (i.e., fault symptoms or fault indicators) by considering how fault impacts propagate across different levels in an HVAC system. A weather and schedule information-based Pattern Matching (WPM) method is employed to automatically create WPM baseline data sets for each incoming real time snapshot data from the building systems. Consequently, BN inference and real-time diagnostics are achieved by comparing incoming snapshot data and the WPM baseline data set. The proposed method is evaluated using experimental fault data collected in a campus building. Fault diagnosis results demonstrate that the WPM-DisBN method is effective at locating the root causes of cross-level faults in an HVAC system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Updated U.S. Low-Temperature Heating and Cooling Demand by County and Sector

This dataset includes U.S. low-temperature heating and cooling demand at the county level in major end-use sectors: residential, commercial, manufacturing, agricultural, and data centers. Census division-level end-use energy consumption, expenditure, and commissioned power database were dis-aggregated to the county level. The county-level database was incorporated with climate zone, numbers of housing units and farms, farm size, and coefficient of performance (COP) for heating and cooling demand analysis. This dataset also includes a paper containing a full explanation of the methodologies used and maps. Residential data were updated from the latest Residential Energy Consumption Survey (RECS) dataset (2015) using 2020 census data. Commercial data were baselined off the latest Commercial Building Energy Consumption Survey (CBECS) dataset (2012). Manufacturing data were baselined off the latest Manufacturing Energy Consumption Survey (MECS) dataset (2021).

15 GEOTHERMAL ENERGY↗

Electrical Switching of Nematic Plasmonic Nanocolloids for Infrared Solar Gain Control

Controlling solar gain is essential to reduce the energy consumption by residential and commercial buildings, which are responsible for ≈40% of all energy generated globally. However, the dynamic control of solar gain in the near-infrared that corresponds to ≈50% of the overall Sun's energy at the Earth's surface, separately from the visible spectral range has been a challenge, albeit commercial coatings provide passive control while retaining highly visible transmission. To address this problem, in this paper switchable silver colloids (SSCs) are demonstrated, colloidal analogs of the common silver coatings used for solar gain control. When dispersed in a nematic liquid crystal, orientations of such plasmonic silver nanoplates are controlled by ≈1 V low-voltage electric fields, allowing for sub-second switching of the near-infrared-based solar gain. Installed and retrofit products made from thin films of such nanoplate dispersions confined between glass and plastic substrates, respectively, exhibit electrically controlled infrared-based solar gain while retaining high visible-range transparency, low haze, and high color rendering index. Furthermore, this study's findings reveal a great potential of soft-matter systems in addressing energy-related problems.

36 MATERIALS SCIENCE↗

Learning-Based Demand Response in Grid Interactive Buildings via Gaussian Processes

This paper presents a predictive controller for a grid-interactive multi-zone building where the temperature dynamics are learned via Gaussian Process (GP) regression. We investigate the development of a learning-based predictive control with two main objectives: (i) continuously learn the temperature dynamics of the building based on data; and, (ii) use the learned dynamics to solve a multi-objective predictive control problem to guarantee occupants' comfort and energy efficiency during normal conditions and demand response events. We leverage the probabilistic non-parametric properties of GPs to estimate the (unknown) non-linear temperature dynamics of the building and to incorporate the uncertainty of those predictions in a multi-objective optimization problem. The GP-based predictive control is solved via a zero-order primal-dual projected-gradient algorithm. We evaluate numerically the performance of the proposed controller using a five-zone commercial building.

demand response↗

Climate benefits and building energy efficiency gains from improved roofing insulation in cold climates

The high thermal resistivity of polyisocyanurate insulation is attributed to its closed cell structure that is filled with low-thermal-conductivity blowing agent vapor. However, existing polyisocyanurate products exhibit a decrease in their thermal-resistance values at lower temperatures due to the condensation of the blowing agent vapor. Because use of insulation with higher thermal resistivity can lead to improved energy efficiency of commercial buildings, which results in lower operational greenhouse gas emissions, there is a clear need to address this reduced performance at lower temperatures through product innovation.

54 ENVIRONMENTAL SCIENCES↗

Operational Energy Life Cycle Data Development for the National Institute of Standards And Technology (NIST) Building Industry Reporting and Design for Sustainability (BIRDS) Neutral Environmental Software Tool (NEST)

For this analysis, regionalized life cycle assessment (LCA) results for environmental impacts (using the Tool for Reduction and Assessment of Chemicals and Other Environmental Impacts [TRACI] 2.1) and cumulative energy demand (using the Federal Life Cycle Analysis Commons Elementary Flow List [FEDEFL] Inventory Methods v1.0.0) were evaluated for the production and utilization of electricity, natural gas, fuel oil, and propane as commodities within residential and commercial buildings. These results can used as a framework for future research into net zero, high-performance buildings, such as done here for the Building Industry Reporting and Design for Sustainability (BIRDS) database by the National Institute of Standards and Technology (NIST) Engineering Laboratory. The geographical results were assigned to each United States (U.S.) Zone Improvement Plan (ZIP) code based on the ZIP code location and corresponding Balancing Authority Area, natural gas basin, and Petroleum Administration for Defense Districts (PADDs). Additionally, previously developed models were utilized to develop future life cycle profiles. Projections were based on data available from the U.S. Energy Information Administration Annual Energy Outlook 2022 through 2050 (AEO 2022). Electricity LCA models were updated based on AEO 2022 projected annual generation mixes, while the natural gas baseline model was updated based on projected shares of natural gas types (conventional, shale, tight, and coalbed methane). Projections of crude oil production rates and export rates were applied to the petroleum baseline model in five-year increments to investigate their effects on the life cycle profile of fuel oil and propane. While only 100-year Global Warming Potential (GWP-100) with climate carbon feedback (CC-FB) and Cumulative Energy Demand are shown in Section 4: Results, the complete results, including Acidification Potential, Eutrophication Potential, Freshwater Ecotoxicity Potential, GWP-100 without inclusion of CC-FB, Human Health Impacts Potentials (Cancer, Non-Cancer), Ozone Depletion Potential, Particulate Matter Formation Potential, and Photochemical Smog Formation Potential, are tabulated for each ZIP code in the Excel worksheets that accompany this analysis. For the Excel spreadsheet tools associated with this report, please go to https://www.netl.doe.gov/energy-analysis/details?id=f8890fac-be55-44ac-aaa9-e2888bfabe93

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A critical review of cyber-physical security for building automation systems

Modern Building Automation Systems (BASs), as the brain that enable the smartness of a smart building, often require increased connectivity both among system components as well as with outside entities, such as the cloud, to enable low-cost remote management, optimized automation via outsourced cloud analytics, and increased building-grid integrations. As smart buildings move towards open communication technologies, providing access to BASs through the building's intranet, or even remotely through the Internet, has become a common practice. However, increased connectivity and accessibility come with increased cyber security threats. BASs were historically developed as closed environments with limited cyber-security considerations. As a result, BASs in many buildings are vulnerable to cyber-attacks that may cause adverse consequences, such as occupant discomfort, excessive energy usage, and unexpected equipment downtime. Therefore, there is a strong need to advance the state-of-the-art in cyber-physical security for BASs and provide practical solutions for attack mitigation in buildings. However, an inclusive and systematic review of BAS vulnerabilities, potential cyber-attacks with impact assessment, detection & defense approaches, and cyber resilient control strategies is currently lacking in the literature. This review paper fills the gap by providing a comprehensive up-to-date review of cyber-physical security for BASs at three levels in commercial buildings: management level, automation level, and field level. The general BASs vulnerabilities and protocol-specific vulnerabilities for the four dominant BAS protocols (i.e., BACnet, KNX, LonWorks, and Modbus) are reviewed, followed by a discussion on four attack targets and seven potential attack scenarios. Furthermore, the impact of cyber-attacks on BASs is summarized as signal corruption, signal delaying, and signal blocking. The typical cyber-attack detection and defense approaches are identified at the three levels. Cyber resilient control strategies for BASs under attack are categorized into passive and active resilient control schemes. Open challenges and future opportunities are finally discussed.

97 MATHEMATICS AND COMPUTING↗

Exploration of Domain Aware Machine Learning for Grid Analytics: Transfer-Learnt Energy Models to Assist Buildings Control with Sparse Field Data

Buildings are a primary consumer of energy in the United States and are also increasingly being perceived as providers of grid services such as load shifting, shedding and modulation. High fidelity models of building energy consumption are needed to set appropriate baselines for measurement and verification (M&V) of controllers designed for energy efficient operation of buildings and to enable buildings to provide grid services via. participation in demand response programs. State-of-the-art building energy modeling techniques either rely on Physics based models, or extensive instrumentation of the building envelope to gather “big” data to train machine learning based models such as deep neural networks. While Physics based models are often limited by their accuracy, it is not always feasible to gather a significant amount of field data required to train machine learning based models with sufficient accuracy. In this paper, we explore the use of transfer learning-based strategies to address unsatisfactory accuracy of models for estimating building energy consumption when available field data for training is sparse or of unacceptable quality. In particular, we transfer knowledge in the form of data and parameters, from Physics based simulation frameworks to the field to improve the model accuracy, thus resulting in a Physics-informed Machine Learning framework. We evaluated the efficacy of our approach on field data collected from six commercial buildings and our results indicate that the proposed transfer learning based models provide comparative (and in some cases better) accuracy than state-of-the-art machine learning and deep learning solutions, with just one month of field data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model Energy Codes End-Use Opportunity Analysis

Model energy codes (ASHRAE Standard 90.1 and IECC) has significantly impacted programs and policies aimed at improving energy efficiency both in United States and across the globe. Standard 90.1, first published in 1975 (originally referred to as Standard 90) provides minimum energy efficiency guidelines for designing, constructing, operating, and maintaining new construction and renovated buildings. It is updated continuously, with new editions published every 3 years. Pacific Northwest National Laboratory (PNNL) conducts simulated energy and cost savings analysis of model energy codes to determine their expected impact and to track progress toward net-zero goals and efficiency targets. Additionally, the simulation outputs are examined to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles. This end-use opportunity analysis of model energy codes provides ASHRAE technical committees and other interested parties a better understanding of how the Standard affects various building systems and end uses, specifically, those in the Standard that most prominently influence energy efficiency. Additionally, findings provide industry stakeholders guidance in identifying building types and end-uses with the most potential for energy efficiency improvements through energy codes and those that may require beyond code measures to meet energy use reduction targets. This paper summarizes features and functionalities of a webtool created by PNNL to explore and visualize the End-Use opportunity analysis.

ASHRAE 90.1, Energy Codes, Tableau↗

A Numerical Study on the Energy Performance of a Novel Furnace With Acidic Gas Trap Absorbers

Natural gas furnaces are widely used in US residential and commercial building markets. An important issue for natural gas furnaces is serious corrosion and fouling problems caused by acidic gas, such as SOx. An advanced adsorption technology based on acidic gas trap (AGT) absorbers offers the possibility to remove SOx acidic gas from natural gas furnaces with high efficiency and low cost, thereby enabling the development of condensing furnaces without the use of expensive corrosion resistant materials in the heat exchanger. A three-dimensional (3D) computational fluid dynamics (CFD) model has been developed to evaluate the heat transfer performance of a furnace with AGT absorbers and to compare it with a baseline conventional furnace without the AGT. Moreover, an axisymmetric model has been built focusing on the absorbing process in the AGT. The baseline conventional furnace used for the study is a commercial condensing furnace (Rheem 92% AFUE 84,000 BTU Multi-Position Gas Furnace). This furnace was completely disassembled, and the dimensions of each part were carefully measured and used to build a detailed CFD model. A model representing the new furnace, incorporating the AGT absorbers, was developed by adding the AGT system to the conventional furnace model. For the CFD analysis, a mixture model was employed to characterize the heat and mass transfer during the condensing process in the furnace while considering three components—air, water vapor and liquid water. Condensation takes place in the condensing heat exchanger, where water vapor changes phase to liquid water, and the latent heat is thus used in the furnace for useful heating. The simulation results characterize the energy performance of both the conventional furnace and the novel furnace with AGT absorbers, as well as the reactive processing in the AGT. These results provide insightful guidance for the development of the AGT absorber-based furnace from the perspective of its energy performance and will be used to further optimize this novel furnace design.

Laclair, Tim↗

Dysfunctionality Hazard Curve: Risk-Based Tool to Support the Resilient Design of Systems Subjected to Multihazards

While resilience metrics have been proposed and studied given a functionality recovery curve, they have not emphasized enough on accounting for the uncertainties in the multihazard occurrences and intensities. Moreover, these resilience metrics are not risk-based (i.e., they do not express the system's resilience loss as a frequency of exceedance), leading to inconsistencies in system performance description when compared to performance-based engineering frameworks. A risk-based tool termed dysfunctionality hazard curve is proposed to assess the resilience of systems subjected to single hazards or multihazards with inter-event dependencies. Dysfunctionality hazard curve expresses system resilience performance as frequency of exceedance of time to full functionality. In doing so, it characterizes system recovery as a sequence of repair activities and also considers the uncertainties in the multihazard occurrences and intensities. Dysfunctionality hazard curve is demonstrated for a residential building susceptible to earthquake and hurricane hazards. Results indicate that Dysfunctionality hazard curve for earthquakes is greater than that for hurricane winds under single hazards. Under multihazards, considering inter-event dependencies during system recovery leads to larger dysfunctionality hazard curve than ignoring them. Finally, the concept of dysfunctionality hazard curve is also extended to a system-of-systems consisting of residential and commercial buildings.

42 ENGINEERING↗

HVAC Duct Pressure Optimization System

The US Department of Energy, the California Energy Commission, and other public and private entities including the venture capital community are seeking technical solutions that include “smart, grid-interactive, efficient buildings - to best serve the needs of building occupants and the grid while reducing energy consumption overall.” In this paper, a systems engineering approach is used to examine elements of a prior proof-of-concept project along with new ideas seeking to justify additional research funding to further advance the technology. With additional research and development funding, the technology described here has the potential to achieve success toward development of a commercially viable product. These types of projects provide financial and environmental benefit to American taxpayers and investors. Cost effectiveness and return on investment are key criteria for energy efficiency projects. By evaluating the end-to-end processes including manufacturing, installation, commissioning and comparing various options, we arrived at a proposed implementation concept of a HVAC Duct Pressure Optimization System that saves energy in commercial buildings and improves the return on investment by a factor of 6X compared to previous research projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tides on South Mill Apartment Complex

This dataset includes data from the building management system for a large multi-family rental property located in Tempe, Arizona. The name of this rental property is “Tides on South Mill” and it is owned by the FCP which is a real-estate investment company based in Maryland with a large portfolio of rental properties that spreads out throughout the U.S. FCP’s portfolio includes large multi-family housing and commercial buildings. The property is split into four quadrants. Each quadrant has roughly 130 apartments. The total floor area of each Quadrant is about 94,000 sq. ft. The campus of Solara spreads over 27 acres. The mechanical system consists of a 2-pipe system that runs chilled or hot water thru individual Fan Coil Units depending upon the season. The gas-fired boiler will supply hot water when seasonal change-over will take place. This dataset spans October to December 2021 and includes time-series measurements corresponding electricity meter data (Cooling Tower Fan, Pumps, Chillers,) with 1-minute resolution, chilled water temperature data and outside air data with 5-minute resolution etc. as CSV files. In addition to the measurements, a metadata .json file, and a .pdf dataset description file are also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensor and Actuator Attacks on Hierarchical Control Systems with Domain-Aware Operator Theory

Cyber-Physical Systems (CPSs) provide opportunities for cyber attacks to have physical impacts. Advanced Persistent Threats (APTs) are a subclass of cyber threats that act stealthily to avoid detection and enable long-term attacks. Here, we build on our past work in APT modelling to combine deception-based sensor bias attacks and direct actuator manipulations in attacks against a hierarchical control system. That past work used the Koopman operator to develop a data-driven, domain-aware, optimization-based attacker model. Using an expansion of this model, we compute several different attacks, including multiple simultaneous attacks, against a high-fidelity commercial building emulator and compare the impacts of those attacks to each other. One next step of interest is to construct a defender system, built on the same modelling approach, designed to detect and mitigate such attacks.

koopman operator, Cyber-Physical Security, machine↗

Design and Fabrication of Polyisocyanurate Foams toward Significantly Enhanced Thermal Resistivity

Developing high-performance thermal insulation is vital for addressing the ongoing global demand for reduced energy costs. Polyisocyanurate (PIR) foams are commonly used in residential and commercial buildings and in various industrial applications owing to their relatively high thermal insulation properties and fire resistivity. Here, this study aims to further improve the thermal resistivity of PIR foams by (1) incorporating low thermal conductivity blowing agents; (2) tailoring the anisotropy of their cells; (3) tuning polymeric isocyanate quantities; and (4) incorporating a facer barrier, while using steps that easily integrate into current manufacturing processes for PIR foams. The resulting PIR foams exhibit a significant enhancement in thermal resistivity, achieving initial values as high as 8.3 h·ft 2 ·°F/Btu/in., commonly abbreviated as R-8.3/in., which is a 20% improvement compared with that of commercially used PIR foams that achieve approximately R-7/in. The detailed analysis of thermal conductivity measurements, mechanical testing, and morphological characterization elucidates the structure–property relationships. The developed high-performance PIR foams provide a critical pillar for next-generation high-performance insulation, offering promising thermal insulation for buildings and many other applications that have a significant effect on global energy costs.

Anisotropic pores↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Comparing the economic performance of ice storage and batteries for buildings with on-site PV through model predictive control and optimal sizing

Integrating renewable energy and energy storage systems provides a way of operating the electrical grid system more energy efficiently and stably. Thermal storage and batteries are the most common devices for integration. However, it is not clear which integrated storage system performs better in terms of overall economics. Ice storage has low initial and maintenance costs, but there is an efficiency penalty for charging of storage and it can only shift electrical loads associated with building cooling requirements. A battery's round-trip efficiency, on the contrary, is quite consistent and batteries can be used to shift both HVAC and non-HVAC loads. However, batteries have greater initial costs and a shorter life. Finally, this research presents a tool, using model predictive control and optimal sizing, and provides a case study for comparing life-cycle economics of battery and ice storage systems for commercial buildings that have chillers for cooling and an on-site photovoltaic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗