Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Constraining magnetic fields in the circumgalactic medium

ABSTRACT We study the properties of magnetic fields in the circumgalactic medium (CGM) of z < 1 galaxies by correlating Faraday rotation measures (RMs) of ∼1000 high-redshift radio sources with the foreground galaxy number density estimated from the DESI Legacy Imaging Surveys. This method enables us to extract signals of RMs contributed by intervening gas around multiple galaxies. Our results show that there is no detectable correlation between the distribution of RMs and the number of foreground galaxies, contrary to several previous results. Utilizing the non-detection signals, we estimate 3σ upper limits to the RMs from the CGM of $\sim \!20 \rm \ rad\, m^{-2}$ within 50 kpc and $\sim \!10 \rm \ rad \, m^{-2}$ at separations of 100 kpc. By adopting a column density distribution of ionized gas obtained from absorption-line measurements, we further estimate the strengths of coherent magnetic fields parallel to the line of sight of $\lt \rm 2 \ \mu G$ in the CGM. We show that the estimated upper limits of RMs and magnetic field strengths are sufficient to constrain outputs of recent galaxy magnetohydrodynamic simulations. Finally, we discuss possible causes for the inconsistency between our results and previous works.

79 ASTRONOMY AND ASTROPHYSICS↗

Total internal reflection enabled wide-field Coherent anti-Stokes Raman scattering microscopy

A system is provided. The system has a femtosecond oscillator to generate pulses used for pump and probe beams. A photonic crystal fiber is disposed in a path of the probe beam and produces pulses for a chirped probe beam. A high NA objective receives the pump and the chirped probe beam, redirects the received beams through a dielectric substrate towards an interface between a sample and the dielectric substrate to cause total internal reflection (TIR) at the sample-substrate interface, and produces corresponding evanescent waves in a portion of the sample adjacent to the sample-substrate interface, and collects a backward-propagating beam of pulses of responsive light. The portion of the sample illuminated by the evanescent waves emits responsive light. The dielectric substrate is transparent to the responsive light, the pump and the chirped probe beam. An image is produced having a specific image size using the received backward-propagating beam.

Doughty, Benjamin L.↗

Towards Content Authenticity: Multimodal Fake News Detection and AI-Generated Text Identification

In today’s digital world, the spread of fake news and the rise of AI-generated text have become major threats to content authenticity and public trust. This thesis addresses both challenges through two complementary research directions: detecting fake news using multimodal features, and identifying AI-generated text using semantic and structural reasoning. The first part of the work focuses on fake news detection by introducing a novel model that combines text and image features through a unique rotational attention mechanism. Unlike traditional attention methods, this approach rotates the roles of query, key, and value across modalities to capture deeper interactions. Additionally, the model incorporates external domain information by linking news posts to top-ranked websites from Google search results, which helps assess the credibility of content based on its broader web context. This results in a more reliable and accurate fake news detection system that outperforms existing state-of-the-art methods. The second part presents SGG-ATD, a new framework for detecting AI-generated text. It uses masked language modeling to measure sentence coherence, followed by constructing a graph where keywords—both original and predicted—are connected based on semantic and contextual similarity. A Graph Convolutional Network (GCN) is then used to learn structural relationships within the text for final classification. Experimental results demonstrate that SGG-ATD achieves high F1-scores and consistently outperforms strong baselines. This method contributes to robust AI text detection, supporting accountability and resilience against AI-driven misinformation.

Gupta, Nidhi↗

Quasiparticle Spectroscopy, Transport, and Magnetic Properties of Nb Films Used in Superconducting Qubits

Niobium thin films on silicon substrate used in the fabrication of superconducting qubits have been characterized using scanning and transmission electron microscopy, electrical transport, magnetization, the London penetration depth - based quasiparticle spectroscopy, and real-space real-time magneto-optical imaging. Here we study niobium films to provide an example of a comprehensive analytical set that may benefit superconducting circuits such as those used in quantum computers. The films have a superconducting transition temperature of T c = 9.35 K and a fairly clean superconducting gap. The estimated superfluid density is enhanced at intermediate temperatures. These observations are consistent with the recent theory of anisotropic strong-coupling superconductivity in Nb and indicate outstanding quality. However, the response to the magnetic field is complicated, exhibiting significantly irreversible behavior and insufficient heat dissipation (to a substrate), leading to thermomagnetic instabilities. This may present a challenge for further improvement of transmon quantum coherence. Possible mitigation strategies are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A MUSE source-blind survey for emission from the circumgalactic medium

The recent detection of optical emission lines from the circumgalactic medium (CGM) in combined, large samples of low-redshift, normal galaxy spectra hints at the potential to map the cool (∼10 4 kelvin) CGM in individual, representative galaxies. Using archival data from a forefront instrument (MUSE) on the VLT, we present a source-blind, wide-redshift-range (z∼ 0 to 5) narrowband imaging survey for CGM emission. Our detected, resolved emission line sources are cataloged and include a 30-kiloparsec-wide Hα source likely tracing the CGM of a low-mass galaxy (stellar mass ∼ 10 8.78±0.42 solar mass) atz= 0.1723, a 60-kiloparsec-wide Ly α structure associated with a galaxy atz= 3.9076, and a 130-kiloparsec (∼r vir )–wide [O II] feature revealing an interaction between a galaxy pair atz= 1.2480. The Hα velocity field for the low-mass galaxy suggests that the CGM is more chaotic or turbulent than the galaxy disk, while that for the interacting galaxies shows large-scale (∼50 kiloparsec) coherent motions.

Science & Technology - Other Topics↗

Colossal Terahertz Emission with Ultrafast Tunability Based on Van der Waals Ferroelectric NbOI 2

Abstract Terahertz (THz) technology is critical for quantum material physics, biomedical imaging, ultrafast electronics, and next‐generation wireless communications. However, standing in the way of widespread applications is the scarcity of efficient ultrafast THz sources with on‐demand fast modulation and easy on‐chip integration capability. Here the discovery of colossal THz emission is reported from a van der Waals (vdW) ferroelectric semiconductor NbOI 2 . Using THz emission spectroscopy, a THz generation efficiency an order of magnitude higher than that of ZnTe, a standard nonlinear crystal for ultrafast THz generation is observed. The underlying generation mechanisms associated are further uncovered with its large ferroelectric polarization by studying the THz emission dependence on excitation wavelength, incident polarization, and fluence. Moreover, the ultrafast coherent amplification and annihilation of the THz emission and associated coherent phonon oscillations by employing a double‐pump scheme are demonstrated. These findings combined with first‐principles calculations, inform a new understanding of the THz light–matter interaction in emergent vdW ferroelectrics and pave the way to develop high‐performance THz devices on them for quantum materials sensing and ultrafast electronics.

Subedi, Sujan [Department of Materials Science and↗

Charged Wellbore Casing Controlled Source Electromagnetics (CWC-CSEM) for Reservoir Imaging and Monitoring (Final report)

This project addresses the needs of the U.S. Department of Energy (DOE) to develop advanced monitoring technologies and protocols to track the fate of subsurface carbon dioxide (CO2) plumes for carbon storage. Specifically, the project seeks to develop and test a unique and novel system of technologies consisting of electromagnetic data acquisition, coupled multiphysics imaging, and reservoir model enhancement to understand the migration and long-term distribution of CO2 in the subsurface. The overarching objective is to develop an integrated approach for long term monitoring of carbon storage. The two main components of the project include the methodology development and the test of the method at a field site. The methodology component consists of 1) developing the field procedure and protocol for collecting time-lapse controlled-source electromagnetic (CSEM) data with source electric current injected into the subsurface through wellbore casings; 2) building of background 3D electrical conductivity utilizing multiple sources of data such as supplemental surface transient EM (TEM) surveys, well-logs, and seismic structural information, for enhancing CSEM signal from reservoir depths; and 3) coupled multiphysics simulations and inversion of CSEM data constrained by production data and by structural information from seismic imaging of the reservoir and overlying formations. The testing component used the field site of Bell Creek Oil Field, which served both as a field laboratory for the method development as well as a test site to evaluate the CSEM signal strengths and the methodology developed in this research project. We have accomplished all the proposed tasks and developed the methodology as planned. These include the procedure for time-lapse CSEM data acquisition, data processing techniques, integration with 3D conductivity model building, fast reservoir simulation for history matching using machine learning, and interpreting CSEM data with coupling to the reservoir modeling. Collectively, the outcome of these tasks form a coherent workflow that can be applied to monitor dedicated carbon storage in saline reservoirs. The testing component evaluated the applicability and limitations of the method, and concluded that the method would be ideal for monitoring dedicated carbon storage sites utilizing saline reservoirs.

54 ENVIRONMENTAL SCIENCES↗

Full configuration interaction simulations of exchange-coupled donors in silicon using multi-valley effective mass theory

Abstract Donor spins in silicon have achieved record values of coherence times and single-qubit gate fidelities. The next stage of development involves demonstrating high-fidelity two-qubit logic gates, where the most natural coupling is the exchange interaction. To aid the efficient design of scalable donor-based quantum processors, we model the two-electron wave function using a full configuration interaction method within a multi-valley effective mass theory. We exploit the high computational efficiency of our code to investigate the exchange interaction, valley population, and electron densities for two phosphorus donors in a wide range of lattice positions, orientations, and as a function of applied electric fields. The outcomes are visualized with interactive images where donor positions can be swept while watching the valley and orbital components evolve accordingly. Our results provide a physically intuitive and quantitatively accurate understanding of the placement and tuning criteria necessary to achieve high-fidelity two-qubit gates with donors in silicon.

Joecker, Benjamin (ORCID:0000000302635440)↗

Frequency comb ptychoscopy

Multiheterodyne techniques using frequency combs—radiation sources whose lines are perfectly evenly-spaced—have revolutionized science. By beating sources with the many lines of a comb, their spectra are recovered. Even so, these approaches are fundamentally limited to probing coherent sources, such as lasers. They are unable to measure most spectra that occur in nature. Here we present frequency comb ptychoscopy, a technique that allows for the spectrum of any complex broadband source to be retrieved using a comb. In this approach, the spectrum is reconstructed by unfolding the simultaneous beating of a source with each comb line. We demonstrate this both theoretically and experimentally, at microwave frequencies. This approach can reconstruct the spectrum of nearly any complex source to high resolution, and the speed, resolution, and generality of this technique will allow chip-scale frequency combs to have an impact in a wide swath of new applications, such as remote sensing and passive spectral imaging.

42 ENGINEERING↗

Effect of metal encapsulation on bulk superconducting properties of niobium thin films used in qubits

Niobium metal occupies nearly 100% of the volume of a typical 2D transmon device. While the aluminum Josephson junction is of utmost importance, maintaining quantum coherence across the entire device means that pair-breaking in Nb leads, capacitive pads, and readout resonators can be a major source of decoherence. The established contributors are surface oxides and hydroxides, as well as absorbed hydrogen and oxygen. Metal encapsulation of freshly grown surfaces with non-oxidizing metals, preferably without breaking the vacuum, is a successful strategy to mitigate these issues. While the positive effects of encapsulation are undeniable, it is important to understand its impact on the macroscopic behavior of niobium films. We present a comprehensive study of the bulk superconducting properties of Nb thin films encapsulated with gold and palladium/gold, and compare them to those of bare Nb films. Magneto-optical imaging, magnetization, resistivity, and London and Campbell penetration depth measurements reveal significant differences in encapsulated samples. Both sputtered, and epitaxial Au-capped films exhibit the highest residual resistivity ratio and superconducting transition temperature, as well as the lowest upper critical field, London penetration depth, and critical current. These results are in good agreement with the microscopic theory of anisotropic normal and superconducting states of Nb. We conclude that pair-breaking in the bulk of niobium films, driven by disorder throughout the film rather than just at the surface, is a significant source of quantum decoherence in transmons. We also conclude that gold capping not only passivates the surface but also affects the properties of the entire film, significantly reducing the scattering rate due to defects likely induced by surface diffusion if the film is not protected immediately after fabrication.

Datta, Amlan [Ames Lab; Iowa State U.]↗

Attosecond light science and its application for probing quantum materials

In this paper, we review the development and application of coherent short wavelength light sources implemented using the high harmonic generation (HHG) process. The physics underlying HHG brought quantum physics into the domain of attosecond time-scales for the first time. Here, the observation and manipulation of electron dynamics on such short time-scales—a capability not conceived—of just a few decades ago—is becoming both more-and-more sophisticated and useful as a route to achieve exquisite control over short wavelength light. New experimental techniques are enabling HHG light sources to provide new insights into fundamental quantum interactions in materials, making it possible for the first time to capture the fastest charge, spin, photon and phonon interactions and to achieve diffraction-limited imaging at short wavelengths.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

EdgeAI: Machine learning via direct attached accelerator for streaming data processing at high shot rate x-ray free-electron lasers

We present a case for low batch-size inference with the potential for adaptive training of a lean encoder model. We do so in the context of a paradigmatic example of machine learning as applied in data acquisition at high data velocity scientific user facilities such as the Linac Coherent Light Source-II x-ray Free-Electron Laser. We discuss how a low-latency inference model operating at the data acquisition edge can capitalize on the naturally stochastic nature of such sources. We simulate the method of attosecond angular streaking to produce representative results whereby simulated input data reproduce high-resolution ground truth probability distributions. By minimizing the mean-squared error between the decoded output of the latent representation and the ground truth distributions, we ensure that the encoding layers and resulting latent representation maintains full fidelity for any downstream task, be it classification or regression. We present throughput results for data-parallel inference of various batch sizes, some with throughput exceeding 100 k images per second. We also show in situ training below 10 s per epoch for the full encoder–decoder model as would be relevant for streaming and adaptive real-time data production at our nation’s scientific light sources.

97 MATHEMATICS AND COMPUTING↗

Edge turbulence velocity preceding the L-H transition in NSTX

The low-to-high mode or L-H transition in tokamaks involves a sudden reduction in the edge turbulence level and decrease in the edge plasma transport. The mechanism for the L-H transition is widely believed to be associated changes in the the poloidal velocity of the edge turbulence. Using a gas puff imaging (GPI) diagnostic, the poloidally averaged poloidal turbulence velocity < V pol > pol was measured for a set of 16 shots with L-H transitions in NSTX. These measurements were focused -2 cm inside the separatrix where the relative fluctuation level as seen in GPI decreases significantly and consistently at the transition. Herein, the magnitude of this poloidal velocity preceding the transition varied widely, ranging from |V pol | ~1-4 km/sec during the last 1 msec before the transition, and the magnitude of the radial gradient also had a wide shot-to-shot range of |grad V pol | ~ 0.34 to 1.9 km/sec/cm during this same time. The frequency spectrum of < V pol > pol during the 30 msec before the transition had a near-coherent peak at ~2-5 kHz, but only in about half of these shots. In general, there were no clear and consistent changes in the poloidal velocity of the turbulence preceding the L-H transition in this database.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid time–frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

We demonstrate a hybrid time–frequency spectroscopic method for simultaneous temperature/pressure measurements in nonreacting compressible flows with known gas composition. Hybrid femtosecond–picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an ∼ <#comment/> 5 -mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay ( τ <#comment/> 1 = 0 p s ) and pressure from spectra obtained at probe delays of τ <#comment/> 2 = 150 − <#comment/> 1000 p s , where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded air jet permits evaluation of this hybrid time–frequency domain approach for temperature and pressure measurements across a wide range of low-temperature–low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approaching 1%−2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four ( τ <#comment/> 2 / τ <#comment/> R > <#comment/> 4 ). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapolated high-temperature Q -branch linewidths are presented. Considering all measurements with τ <#comment/> 2 / τ <#comment/> R ≥ <#comment/> 4.0 , measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representing a combination of instrument noise and fluid fluctuations of 5.0%.

Retter, Jonathan E.↗

Non-local detection of coherent Yu–Shiba–Rusinov quantum projections

Probing spatially confined quantum states from afar—a long-sought goal to minimize external interference—has been proposed to be feasible in condensed-matter systems through the coherent projection of the state. This can be achieved by engineering the eigenstates of the electron sea that surrounds the quantum state using cages built atom by atom, the so-called quantum corrals. However, the demonstration of the coherent nature of the projection and manipulation of its quantum composition are still important goals. Here we show this for the coherent projection of a Yu–Shiba–Rusinov quantum state that is induced by a magnetic impurity, using the eigenmodes of corrals on the surface of a superconductor. This enables us to manipulate the particle–hole composition of the projected state by tuning the corral eigenmodes through the Fermi energy. Our results demonstrate a controlled non-local method for the detection of magnet–superconductor hybrid quantum states.

quantum mechanics↗

Designing high-power, octave spanning entangled photon sources for quantum spectroscopy

Entangled photon spectroscopy is a nascent field that has important implications for measurement and imaging across chemical, biology, and materials fields. Entangled photon spectroscopy potentially offers improved spatial and temporal-frequency resolutions, increased cross sections for multiphoton and nonlinear measurements, and new abilities in inducing or measuring quantum correlations. A critical step in enabling entangled photon spectroscopies is the creation of high-flux entangled sources that can use conventional detectors as well as provide redundancy for the losses in realistic samples. Here, we report a periodically poled, chirped, lithium tantalate platform that generates entangled photon pairs with ~10 -7 efficiency. For a near watt level diode laser, this results in a near μW-level flux. The single photon per mode limit that is necessary to maintain non-classical photon behavior is still satisfied by distributing this power over up to an octave-spanning bandwidth. The spectral–temporal photon correlations are observed via a Michelson-type interferometer that measures the broadband Hong–Ou–Mandel two-photon interference. A coherence time of 245 fs for a 10 nm bandwidth in the collinear case and a coherence time of 62 fs for a 125 nm bandwidth in the non-collinear case are measured using a CW pump laser and, essentially, collecting the full photon cone. We outline in detail the numerical methods used for designing and tailoring the entangled photons source, such as changing center wavelength or bandwidth, with the ultimate aim of increasing the availability of high-flux UV–Vis entangled photon sources in the optical spectroscopy community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hybridized Exciton-Photon-Phonon States in a Transition Metal Dichalcogenide van der Waals Heterostructure Microcavity

Excitons in atomically thin transition-metal dichalcogenides (TMDs) have been established as an attractive platform to explore polaritonic physics, owing to their enormous binding energies and giant oscillator strength. Basic spectral features of exciton polaritons in TMD microcavities, thus far, were conventionally explained via two-coupled-oscillator models. This ignores, however, the impact of phonons on the polariton energy structure. Here we establish and quantify the threefold coupling between excitons, cavity photons, and phonons. For this purpose, we employ energy-momentum-resolved photoluminescence and spatially resolved coherent two-dimensional spectroscopy to investigate the spectral properties of a high-quality-factor microcavity with an embedded WSe 2 van der Waals heterostructure at room temperature. Our approach reveals a rich multibranch structure which thus far has not been captured in previous experiments. Simulation of the data reveals hybridized exciton-photon-phonon states, providing new physical insight into the exciton polariton system based on layered TMDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Engineering diamond interfaces free of dark spins

Nitrogen-vacancy (NV) centers in diamond are utilized extensively as quantum sensors for imaging fields at the nanoscale. The ultrahigh sensitivity of NV magnetometers has enabled the detection and spectroscopy of individual electron spins, with potentially far-reaching applications in condensed matter physics, spintronics, and molecular biology. However, the surfaces of these diamond sensors naturally contain electron spins, which create a background signal that can be hard to differentiate from the signal of the target spins. In this study, we develop a surface modification approach that eliminates the unwanted signal of these so-called dark electron spins. Our surface passivation technique, based on coating diamond surfaces with a thin titanium oxide (Ti⁢O 2 ) layer, reduces the dark spin density. The observed reduction in dark spin density aligns with our findings on the electronic structure of the diamond-Ti⁢O 2 interface. The reduction, from a typical value of 2000 μm −2 to a value below that set by the detection limit of our NV sensors (200 μm −2 ), results in a twofold increase in Hahn-echo coherence time of near surface NV centers. Furthermore, we derive a comprehensive spin model that connects dark spin relaxation with NV coherence, providing additional insights into the mechanisms behind the observed spin dynamics. Our findings are directly transferable to other quantum platforms, including nanoscale solid-state qubits and superconducting qubits.

74 ATOMIC AND MOLECULAR PHYSICS↗