Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Independent technical review of the building 100 plume, former doe pinellas site (young - rainey star center), largo, florida

Contaminated groundwater associated with Building 100 at the Young-Rainey Science, Technology, and Research Center, formerly the DOE Pinellas plant, is the primary remedial challenge that remains to be addressed at the site. Currently, Building 100 is an active industrial facility that is now owned and operated by the Pinellas county government. Groundwater samples collected from monitoring wells recently installed near the southern boundary of the site suggest that contaminated groundwater has migrated off the plant site. In response to the challenges presented by the Building 100 plume, the Office of Legacy Management (LM) requested assistance from the DOE Office of Groundwater and Soil Remediation (EM-32) to provide a review team to make technical recommendations so that they can efficiently and effectively address characterization and remediation of the plume. The review team was unanimous in the conclusion that a dynamic strategy that combines a phased implementation of direct push samplers, sensors, and tools can be used to better delineate the extent of contamination, control plume migration, and rapidly remediate the contaminated groundwater at the site. The initial efforts of the team focused on reviewing the site history and data, organizing the information into a conceptual model, identifying appropriate technologies, and recommending an integrated strategy. The current groundwater data from the site indicate a two-lobed plume extending to the east and south. To the east vinyl chloride is the primary contaminant of concern, to the south, vinyl chloride and cis1, 2-DCE are the primary contaminants. The limited data that are available suggest that reductive dechlorination of the TCE is already occurring but is not sufficient to prevent offsite migration of low concentrations of TCE daughter products. The team recommends that DOE pursue a strategy that builds on the natural cleansing capacity of the subsurface with reductive methods including biostimulation and/or bioaugmentation to provide a sustainable remediation system within the flow path of the plume. Additional data will be required to implement this approach and will include: (1) Better delineation of the nature and extent of contamination; (2) Demonstration the plume is currently stable or shrinking; and (3) Demonstration the full reductive dechlorination is occurring. The technical team recommends that DOE use a phased approach to identify residual contamination and to provide rapid installation of remedies. Matrices of characterization and remediation sensors, technologies, and tools were developed by the team in order to match the specific conditions and requirements of the site. The team provides a specific example of remedy that includes the incorporation of a dynamic characterization strategy moving from minimally invasive to more aggressive field techniques, the consideration of multiple complementary remediation approaches based on a spatiotemporally phased approach keyed to the different demands of different parts of the plume, and the integration and sequencing of the characterization and remediation activities.

54 ENVIRONMENTAL SCIENCES↗

Unofficial Road Building in the Brazilian Amazon: Dilemmas and Models for Road Governance

Unofficial roads form dense networks in landscapes, generating a litany of negative ecological outcomes, but unofficial roads in frontier areas are also instrumental in local livelihoods and community development. This trade-off poses dilemmas for the governance of unofficial roads. Unofficial road building in frontier areas of the Brazilian Amazon illustrates the challenges of 'road governance.' Both state-based and community based governance models exhibit important liabilities for governing unofficial roads. Whereas state-based governance has experienced difficulties in adapting to specific local contexts and interacting effectively with local interest groups, community-based governance has a mixed record owing to social inequalities and conflicts among local interest groups. A state-community hybrid model may offer more effective governance of unofficial road building by combining the oversight capacity of the state with locally grounded community management via participatory decision-making.

Perz, Stephen G.↗

COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM

In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

15 GEOTHERMAL ENERGY↗

High-Capacity Hydrogen and Hydrogen Isotope Getters

Hydrogen can quietly build up inside sealed devices and industrial systems, shortening equipment life and creating safety risks. Los Alamos National Laboratory has developed a new class of high-capacity hydrogen getters that permanently remove hydrogen before it causes damage. Compared with conventional getters, this technology stores more hydrogen, operates across a wider range of conditions, and can be manufactured in multiple forms for easy integration into commercial products.

36 MATERIALS SCIENCE↗

Land use and turbine technology influences on wind potential in the United States

As clean energy ambitions have expanded, critically evaluating renewable energy supply has become increasingly important to the energy research community and stakeholders. This study examines the onshore wind resource potential for the conterminous United States and its sensitivity to siting constraints and turbine technology innovation. We compile localized regulatory information and use high-resolution data to present multiple siting regimes covering relatively constrained to unconstrained potentials. Our efforts reveal high sensitivity to these variables and sizable uncertainty in the overall wind energy resource potential. Specifically, we find that siting constraints may shift the total capacity available to commercial wind energy by 2.3–15.1 TW. Furthermore, our results illustrate that technology advancement could require larger setbacks from buildings and infrastructure, reducing the total available capacity potential by 20% relative to estimates using current technology, but that this reduction is largely offset by increased generation such that the net effect on generation is 1%. The observed sensitivity to and uncertainty resulting from the variables we analyze suggest there is value in continued study and development of increasingly sophisticated approaches to characterizing wind resource potential.

14 SOLAR ENERGY↗

What is the Right Size for a Residential Building Parcel Locker?

Common-carrier parcel lockers present a solution for decreasing delivery times, traffic congestion, and emissions in dense urban areas through consolidation of deliveries. Multi-story residential buildings with large number of residents, and thus a high volume of online package orders, are one of the best venues for installing parcel lockers. But what is the right size for a residential building locker that would suit the residents’ and building managers’ needs? Because of the novelty of parcel lockers, there is no clear guideline for determining the right locker size and configuration for a residential building given the resident population. A small locker would result in packages exceeding capacity and being left in the lobby, increasing the building manager’s workload and confusing and inconveniencing users. On the other hand, a large locker is more expensive, more difficult to install, and unappealing to residents. To answer this question, we installed a common-carrier parcel locker in a residential building in downtown Seattle, WA, U.S.A. Through collecting detailed data on locker usage from the locker provider company, we studied and quantified carriers’ delivery patterns and residents’ online shopping and package pickup behaviors. We then used this information to model the locker delivery and pickup process, and simulated several locker configurations to find the one that best suits the delivery needs of the building. These findings could aid urban planners and building managers in choosing the right size for residential building lockers that meet delivery demand while minimizing costs and contributing to environmental benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building energy efficiency and load flexibility optimization using phase change materials under futuristic grid scenario

This work investigates the energy savings and load flexibility capacity of phase change material (PCM) integrated into building envelope under a future energy generation scenario, where 80% of the energy load comes from renewable sources. Using community-scale modeling, we first determine the net thermal storage required to fully manage the demand variability at a utility grid, and then using whole-building simulations we optimize operating parameters - such as PCM thickness, latent heat, interior setpoint profile, PCM distribution, and heat transfer coefficient - to determine the optimal conditions required for maximum energy reduction and load flexibility without compromising occupants' thermal comfort. The optimal PCM-integrated envelope proposed in this study can provide annual load flexibility up to 33.6% and annual energy savings up to 10.8% in a lightweight residential building located in Baltimore, MD. This study is relevant given the increasing contributions of renewable energy in the total energy generation mix, leading to a significant time-imbalance between peak energy demand and peak energy production. While thermal energy storage using PCM is a recognized technique, there is no known prior study dedicated to examining the thermal performance of PCM-integrated envelope under future energy generation scenarios. This study bridges the research gap by investigating a practical way to implement PCMs in the buildings and maximize the energy efficiency as well as load flexibility related benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coordinated microgrid investment and planning process considering the system operator

Nowadays, a significant number of distribution systems are facing problems to accommodate more photovoltaic (PV) capacity, namely due to the overvoltages during the daylight periods. This has an impact on the private investments in distributed energy resources (DER), since it occurs exactly when the PV prices are becoming attractive, and the opportunity to an energy transition based on solar technologies is being wasted. In particular, this limitation of the networks is a barrier for larger consumers, such as commercial and public buildings, aiming at investing in PV capacity and start operating as microgrids connected to the MV network. To address this challenge, this paper presents a coordinated approach to the microgrid investment and planning problem, where the system operator and the microgrid owner collaborate to improve the voltage control capabilities of the distribution network, increasing the PV potential. The results prove that this collaboration has the benefit of increasing the value of the microgrid investments while improving the quality of service of the system and it should be considered in the future regulatory framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Analysis of the Crushing of Honeycomb Cores Under Compression

This paper presents an experimental study of the compressive response of hexagonal honeycomb core from the initial elastic regime to a fully crushed state. To understand the crushing mechanism, aluminum honeycomb core was compressed quasi-statically between rigid platens under displacement control. Honeycomb test specimens made of aluminum alloy with different configurations such as cell size, cell number, core density, and specimen size have been tested. During the crushing, the cells buckle elastically and collapse at a higher stress due to inelastic action, after the cells crush by progressive formation of folds on cell walls. The response densifies when folds consume the whole panel height. The peak load recorded during tests corresponded to the buckling of honeycomb cells. The different specimens showed similar load/displacement curves, and the differences observed were only due to the influence of the core density, number of cells, and specimens size on mechanical behavior of hexagonal honeycomb core which has a very important role in the energy absorption capacity. In addition, this study allowed us to build a database of experimental tests for various configurations and allowed us to know the precise energy absorption capacity.

36 MATERIALS SCIENCE↗

Optimization of a solar cooling system with interior energy storage

This paper focuses on the optimization of the performance of a solar absorption cooling system composed by four units with interior energy storage. A full dynamic simulation model that includes the solar collector field, the absorption heat pump system and the building load calculation has been developed. It has been applied to optimize the coupling of a system based on this new technology of solar powered absorption heat pump, to a bioclimatic building recently constructed in the Plataforma Solar de Almeria (PSA) in Spain. The absorption heat pump system considered is composed by four heat pumps that store energy in the form of crystallized salts so that no external storage capacity is required. Each heat pump is composed of two separate barrels that can charge (store energy from the solar field) and discharge (deliver heat or cold to the building) independently. Different configurations of the four units have been analysed taking into account the storage possibilities of the system and its capacity to respond to the building loads. It has been shown how strong the influence of the control strategies in the overall performance is, and the importance of using hourly simulations models when looking for highly efficient buildings. (author)

14 SOLAR ENERGY↗

Demand Response Potential for California SubLAPs and Local Capacity Planning Areas: An Addendum to the 2025 California Demand Response Potential Study – Phase 2

The 2025 California Demand Response Potential Study Phase 2 Report1 was released on March 1, 2017, and described a range of pathways for Demand Response (DR) to support a clean, stable, and cost-effective electric grid for California. One of the Report’s key findings was that while there appears to be very low future value for untargeted DR Shed aimed at system-wide peak load conditions, there could be significant value for locally focused Shed resources. Although the dynamics of renewable capacity expansion have reduced the pressure to build new thermal generation in general, there are still transmission-constrained areas of the state where load growth needs to be managed with the addition of new local capacity, which could include DERs and/or DR. This Addendum to the Phase 2 Report presents a breakdown of the expected future “Local Shed” DR potential at a finer geographic resolution than what is available in the original report, with results summarized by SubLAP and Local Capacity Area (LCA).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing laboratory capacity during Ebola virus disease (EVD) heightened surveillance in Liberia: lessons learned and recommendations

Following a declaration by the World Health Organization that Liberia had successfully interrupted Ebola virus transmission on May 9th, 2015; the country entered a period of enhanced surveillance. The number of cases had significantly reduced prior to the declaration, leading to closure of eight out of eleven Ebola testing laboratories. Enhanced surveillance led to an abrupt increase in demand for laboratory services. We report interventions, achievements, lessons learned and recommendations drawn from enhancing laboratory capacity. Using archived data, we reported before and after interventions that aimed at increasing laboratory capacity. Laboratory capacity was defined by number of laboratories with Ebola Virus Disease (EVD) testing capacity, number of competent staff, number of specimens tested, specimen backlog, daily and surge testing capacity, and turnaround time. Using Stata 14 (Stata Corporation, College Station, TX, USA), medians and trends were reported for all continuous variables. Our results show that between May and December 2015, interventions including recruitment and training of eight staff, establishment of one EVD laboratory facility, implementation of ten Ebola GeneXpert diagnostic platforms, and establishment of working shifts yielded an 8-fold increase in number of specimens tested, a reduction in specimens backlog to zero, and restoration of turn-around time to 24 hours. This enabled a more efficient surveillance system that facilitated timely detection and containment of two EVD clusters observed thereafter. In conclusion, effective enhancement of laboratory services during high demand periods requires a combination of context-specific interventions. Building and ensuring sustainability of local capacity is an integral part of effective surveillance and disease outbreak response efforts.

60 APPLIED LIFE SCIENCES↗

Rooftop Solar Photovoltaic Technical Potential in the United States

How much energy could we generate if PV modules were installed on all of the suitable roof area in the nation? To answer this question, we first use GIS methods to process a lidar dataset and determine the amount of roof area that is suitable for PV deployment in 128 cities nationwide, containing 23% of U.S. buildings, and provide PV-generation results for a subset of those cities. We then extend the insights from that analysis to the entire continental United States. We develop two statistical models -- one for small buildings and one for medium and large buildings -- and populate them with geographic variables that correlate with rooftop's suitability for PV. We simulate the productivity of PV installed on the suitable roof area, and present the technical potential of PV on both small buildings and medium/large buildings for every state in the continental US. Within the 128 cities covered by lidar data, 83% of small buildings have a location suitable for a PV installation, but only 26% of the total rooftop area of small buildings is suitable for development. The sheer number of buildings in this class, however, gives small buildings the greatest technical potential. Small building rooftops could accommodate 731 GW of PV capacity and generate 926 TWh/year of PV energy, approximately 65% of rooftop PV's total technical potential. We conclude by summing the PV-generation results for all building sizes and therefore answering our original question, estimating that the total national technical potential of rooftop PV is 1,118 GW of installed capacity and 1,432 TWh of annual energy generation. This equates to 39% of total national electric-sector sales.

14 SOLAR ENERGY↗

Overview of Building Electrification Technologies and Market Opportunities

This report provides an overview of building electrification drivers and select building electrification technologies and their markets and performance. Covered topics: Building Electrification Drivers and Context; Heat Pumps for Space Conditioning; Heat Pump Market Opportunities; Life Cycle GHG Emissions Impacts of Heat Pump Space Conditioning Technologies; Heat Pump Water Heaters; Electrification of Gas Loads: Commercial and Residential; Residential Panel Capacity; Electric Vehicle Impacts and Connections to Buildings; and Building Envelope Improvements and Thermal Energy Storage (TES) Opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A High-Performance Na-Al Battery Based on Reversible NaAlCl4 Catholyte

This work demonstrates a high-capacity and safe Na-Al battery pairing sodium metal anode and reversible NaAlCl4 catholyte for grid scale energy storage applications. The energy-rich sodium anode allows the full play of the aluminum cathode, resulting in a full-cell capacity of 308 mAh/g at a discharge voltage of 1.6 V. Benefiting from the use of ??-alumina solid electrolyte (BASE), molten sodium anode and reversible Al deposition/stripping from NaAlCl4 catholyte, the battery presents a stable Coulombic efficiency of 100% and energy efficiency of ~95%. At a rate of C/3 (6.77 mA/cm2), the cell maintains 282 mAh/g (447 Wh/kg) after 200 cycles with an excellent capacity retention of 97.6%. Moreover, we elucidate pathways to build sodium-anode-free cells from the discharged state under dry air, which further extends the feasibility of this battery for stationary storage applications. These findings are expected to provide a new platform for the development of practical Al batteries.

Zhan, Xiaowen↗

Prioritization and Implementation Plan for Collaborative Case Study on RPV Steels During Extended Service

Nuclear power currently provides a significant fraction of the United States non-carbon emitting power generation. In future years, nuclear power must continue to generate a significant portion of the nation's electricity to meet the growing electricity demand, clean energy goals, and ensure energy independence. New reactors will be an essential part of the expansion of nuclear power. However, given limits on new builds imposed by economics and industrial capacity, the extended service of the existing fleet will also be required. Ensuring public safety and environmental protection is a prerequisite to all nuclear power plant operating and licensing decisions at all stages of reactor life. This includes the original license period of 40 years, the first license extension to 60 years, and certainly for any consideration of life beyond 60 years. For extended operating periods, it must be shown that adequate aging management programs are present or planned and that appropriate safety margins exist throughout the subsequent license renewal periods. Materials degradation can impact reactor reliability, availability, and potentially, safe operation. Components within a reactor must tolerate the harsh environment of high temperature water, stress, vibration, and/or an intense neutron field. Degradation of materials in this environment can lead to reduced performance, and in some cases, sudden failure. Clearly, understanding materials degradation and accounting for the effects of a reactor environment in operating and regulatory limits is essential. The Light Water Reactor Sustainability (LWRS) Program is designed to support the long-term operation (LTO) of existing domestic nuclear power generation with targeted collaborative research programs into areas beyond current short-term optimization opportunities. Within the LWRS program, two pathways have been initiated to perform research essential to informing relicensing decisions. The Materials Aging and Degradation Pathway is designed to help develop the scientific basis for understanding and predicting long-term environmental degradation behavior of materials in nuclear power plants and to provide data and methods to assess performance of systems, structures, and components essential to safe and sustained operation. The Risk-Informed Safety Margins Characterization Pathway (RISMC) seeks to merge fundamental scientific understanding of critical phenomenological conditions and deterministic predictions of nuclear power plant performance with risk-informed characterization tools. This will provide an integrated characterization of public safety margins in an optimization of nuclear safety, plant performance, and long-term asset management. Clearly, these two pathways have many synergies in goals and outcomes. The data and mechanisms generated in the Materials Pathway may feed into and mold efforts within the RISMC Pathway. In addition, insights from the characterization tools developed in RISMC tasks may inform materials testing needs and experiments. To demonstrate this potentially powerful interaction, a joint case study has been proposed and initiated. This document describes the initial planning for a coordinated study between the Materials and the RISMC Pathways. A brief description of each Pathway is presented along with a more detailed description of the needs and requirements of this collaborative task. A list of criteria for any case-study candidate are then listed, along with the rationale for choosing pressurized thermal shock as the prime candidate an inter-pathway collaboration. A proposed timeline and organization of future interactions on this subject area is also presented.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

§Section 1603 Treasury Grant Expiration: Industry Insight on Financing and Market Implications

In the wake of the 2008-2009 financial crises, tax equity investors largely withdrew from the market, resulting in stagnation of project development. In response, Congress established the Treasury grant program pursuant to Section 1603 of the American Recovery and Reinvestment Act (..Section..1603 Program) to offer a cash payment in lieu of a production and investment tax credit. This studyaddresses the likely project financing and market impacts from the expiration of the ..Section..1603 Program. The authors assembled an array of insights offered by financial executives active in the renewable energy (RE) market during conference panel discussions and in presentations, direct interviews, and email correspondences. This analysis found that the ..Section..1603 Program alleviatedthe need to monetize the tax credit incentives through specialized investors, helped lower the transaction and financing costs associated with renewable electricity projects, and generally supported an extensive build-out of renewable power generation capacity. With the expiration of the ..Section..1603 Program, smaller or less-established renewable power developers will have more difficultyattracting needed financial capital and completing their projects, development of projects relying on newer or 'innovative' technologies will likely slow as traditional tax equity investors are known to be highly averse to technology risk in the projects they fund, and, finally, projects relying on tax equity may be more expensive to develop due to higher transaction costs and potentially higheryields required to attract tax equity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Proof of Concept: Grizzly, the LWRS Program Materials Aging and Degradation Pathway Main Simulation Tool

Nuclear power currently provides a significant fraction of the United States’ non-carbon emitting power generation. In future years, nuclear power must continue to generate a significant portion of the nation’s electricity to meet the growing electricity demand, clean energy goals, and ensure energy independence. New reactors will be an essential part of the expansion of nuclear power. However, given limits on new builds imposed by economics and industrial capacity, the extended service of the existing fleet will also be required.

99 GENERAL AND MISCELLANEOUS↗