Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Diamond detector for high rate monitors of fast neutrons beams

A fast neutron detection system suitable for high rate measurements is presented. The detector is based on a commercial high purity single crystal diamond (SDD) coupled to a fast digital data acquisition system. The detector was tested at the ISIS pulsed spallation neutron source. The SDD event signal was digitized at 1 GHz to reconstruct the deposited energy (pulse amplitude) and neutron arrival time; the event time of flight (ToF) was obtained relative to the recorded proton beam signal t{sub 0}. Fast acquisition is needed since the peak count rate is very high ({approx}800 kHz) due to the pulsed structure of the neutron beam. Measurements at ISIS indicate that three characteristics regions exist in the biparametric spectrum: i) background gamma events of low pulse amplitudes; ii) low pulse amplitude neutron events in the energy range E{sub dep}= 1.5-7 MeV ascribed to neutron elastic scattering on {sup 12}C; iii) large pulse amplitude neutron events with E{sub n} < 7 MeV ascribed to {sup 12}C(n,{alpha}){sup 9}Be and 12C(n,n')3{alpha}.

43 PARTICLE ACCELERATORS↗

Diamond neutral particle spectrometer for fusion reactor ITER

A compact diamond neutral particle spectrometer with digital signal processing has been developed for fast charge-exchange atoms and neutrons measurements at ITER fusion reactor conditions. This spectrometer will play supplementary role for Neutral Particle Analyzer providing 10 ms time and 30 keV energy resolutions for fast particle spectra in non-tritium ITER phase. These data will also be implemented for independent studies of fast ions distribution function evolution in various plasma scenarios with the formation of a single fraction of high-energy ions. In tritium ITER phase the DNPS will measure 14 MeV neutrons spectra. The spectrometer with digital signal processing can operate at peak counting rates reaching a value of 10{sup 6} cps. Diamond neutral particle spectrometer is applicable to future fusion reactors due to its high radiation hardness, fast response and high energy resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

STAR FORMATION IN ORION'S L1630 CLOUD: AN INFRARED AND MULTI-EPOCH X-RAY STUDY

X-ray emission is characteristic of young stellar objects (YSOs) and is known to be highly variable. We investigate, via an infrared and multi-epoch X-ray study of the L1630 dark cloud, whether and how X-ray variability in YSOs is related to protostellar evolutionary state. We have analyzed 11 Chandra X-Ray Observatory observations, obtained over the course of four years and totaling ∼240 ks exposure time, targeting the eruptive Class I YSO V1647 Ori in L1630. We used Two Micron All Sky Survey and Spitzer data to identify and classify IR counterparts to L1630 X-ray sources and identified a total of 52 X-ray-emitting YSOs with IR counterparts, including four Class I sources and one Class 0/I source. We have detected cool (<3 MK) plasma, possibly indicative of accretion shocks, in three classical T Tauri stars. A subsample of 27 X-ray-emitting YSOs were covered by 9 of the 11 Chandra observations targeting V1647 Ori and the vicinity. For these 27 YSOs, we have constructed X-ray light curves spanning approximately four years. These light curves highlight the variable nature of pre-main-sequence X-ray-emitting young stars; many of the L1630 YSOs vary by orders of magnitude in count rate between observations. We discuss possible scenarios to explain apparent trends between various X-ray spectral properties, X-ray variance, and YSO classification.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiple-Coincidence Interrogation of Fissionables

The multiple coincidence technique uses 14.1 MeV neutrons to produce (n, multiple-γ) coincidences to detect fissile and fissionable materials. Measurements of n-γ-γ coincidences with targets of depleted uranium (DU), W, and Pb, show that the counting rate for the DU is substantially above that for the non-fissionables. Also, the data involving prompt neutrons and delayed gammas in the DU time spectra provide a signature for fissionables that is distinct from that of non-fissionables.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistics of X-ray flares of Sagittarius A{sup ⋆}: Evidence for solar-like self-organized criticality phenomena

X-ray flares have routinely been observed from the supermassive black hole at our Galactic center, Sagittarius A{sup ⋆} (Sgr A{sup ⋆}). The nature of these flares remains largely unclear, despite many theoretical models. In this paper, we study the statistical properties of the Sgr A{sup ⋆} X-ray flares by fitting the count rate (CR) distribution and the structure function of the light curve with a Markov Chain Monte Carlo method. With the 3-million-second Chandra observations accumulated in the Sgr A{sup ⋆} X-ray Visionary Project, we construct the theoretical light curves through Monte Carlo simulations. We find that the 2–8 keV X-ray light curve can be decomposed into a quiescent component with a constant CR of 6×10{sup −3} count s{sup −1} and a flare component with a power-law fluence distribution dN/dE∝E{sup −α{sub E}} with α{sub E}=1.65±0.17. The duration–fluence correlation can also be modeled as a power law T∝E{sup α{sub E}{sub T}} with α{sub ET}<0.55 (95% confidence). These statistical properties are consistent with the theoretical prediction of the self-organized criticality system with the spatial dimension S = 3. We suggest that the X-ray flares represent plasmoid ejections driven by magnetic reconnection (similar to solar flares) in the accretion flow onto the black hole.

79 ASTRONOMY AND ASTROPHYSICS↗

Proposed electron halo detector system as one of the beam overlap diagnostic tools for the new RHIC electron lens

An electron lens for head-on beam-beam compensation planned for RHIC requires precise overlap of the electron and proton beams which both can have down to 0.3 mm rms transverse radial widths along the 2m long interaction region. Here we describe a new diagnostic tool that is being considered to aid in the tuning and verification of this overlap. Some of ultra relativistic protons (100 or 250 GeV) colliding with low energy electrons (2 to 10 keV) will transfer sufficient transverse momentum to cause the electrons to spiral around the magnetic guiding field in a way that will make them detectable outside of the main solenoid. Time-of-flight of the halo electron signals will provide position-sensitive information along the overlap region. Scattering cross sections are calculated and counting rate estimates are presented as function of electron energy and detector position.

43 PARTICLE ACCELERATORS↗

Fully depleted CMOS pixel sensor development and potential applications

CMOS pixel sensors are often opposed to hybrid pixel sensors due to their very different sensitive layer. In standard CMOS imaging processes, a thin (about 20 μm) low resistivity epitaxial layer acts as the sensitive volume and charge collection is mostly driven by thermal agitation. In contrast, the so-called hybrid pixel technology exploits a thick (typically 300 μm) silicon sensor with high resistivity allowing for the depletion of this volume, hence charges drift toward collecting electrodes. But this difference is fading away with the recent availability of some CMOS imaging processes based on a relatively thick (about 50 μm) high resistivity epitaxial layer which allows for full depletion. This evolution extents the range of applications for CMOS pixel sensors where their known assets, high sensitivity and granularity combined with embedded signal treatment, could potentially foster breakthrough in detection performances for specific scientific instruments. One such domain is the Xray detection for soft energies, typically below 10 keV, where the thin sensitive layer was previously severely impeding CMOS sensor usage. Another application becoming realistic for CMOS sensors, is the detection in environment with a high fluence of non-ionizing radiation, such as hadron colliders. However, when considering highly demanding applications, it is still to be proven that micro-circuits required to uniformly deplete the sensor at the pixel level, do not mitigate the sensitivity and efficiency required. Prototype sensors in two different technologies with resistivity higher than 1 kΩ, sensitive layer between 40 and 50 μm and featuring pixel pitch in the range 25 to 50 μm, have been designed and fabricated. Various biasing architectures were adopted to reach full depletion with only a few volts. Laboratory investigations with three types of sources (X-rays, β-rays and infrared light) demonstrated the validity of the approach with respect to depletion, keeping a low noise figure. Especially, an energy resolution of about 400 eV for 5 keV X-rays was obtained for single pixels. The prototypes have then been exposed to gradually increased fluences of neutrons, from 10{sup 13} to 5x10{sup 14} neq/cm{sup 2}. Again laboratory tests allowed to evaluate the signal over noise persistence on the different pixels implemented. Currently our development mostly targets the detection of soft X-rays, with the ambition to develop a pixel sensor matching counting rates as affordable with hybrid pixel sensors, but with an extended sensitivity to low energy and finer pixel about 25 x 25 μm{sup 2}. The original readout architecture proposed relies on a two tiers chip. The first tier consists of a sensor with a modest dynamic in order to insure low noise performances required by sensitivity. The interconnected second tier chip enhances the read-out speed by introducing massive parallelization. Performances reachable with this strategy combining counting and integration will be detailed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying Transient Uncertainty in the BEAVRS Benchmark Using Time Series Analysis Methods

Advances in computation have brought about significant improvements in creating fast-running high-fidelity simulations of nuclear cores. The BEAVRS benchmark is a highly-detailed PWR specification with two cycles of measured operational data used to validate high-fidelity core analysis methods. This PWR depletion benchmark captures the fine details of the LWR fuel assemblies, burnable absorbers, in-core fission detectors, core loading and shuffling patterns. Specifically, 58 of the 193 assemblies contain in-core detectors with measurements taken over 61 axial positions every month. These detectors are U-235 fission chambers with slightly varying mass of U-235. The collected signals are normalized on a given assembly permitting full core comparisons. The fuel layout for cycle 1 and instrument tube locations for the reactor are given in figures 1 and 2 respectively. Through a series of data processing and comparisons, it was shown that axially integrated radial maps of reaction rates were in close agreement between provided detector data and calculated data. More recently, the focus of the BEAVRS project has been on quantifying uncertainty to further assess the validity of aforementioned results. A close investigation of sources of error shows that uncertainties from operational nuclear data arise primarily from data measurements and processing. While the errors in axial realignment and interpolation seem significant, these sources affect only a small subset of data points near grid spacers and do not persist throughout the entire core. Instead, measurement uncertainty from detector count rates and radial integration dominate the uncertainty in measured data are determined as the most significant sources of error. This uncertainty analysis treated each given burnup step as independent of comparable data at neighboring burnup steps. More recent work has been targeted at understanding how reaction rates vary over time, in order to determine whether calculated reaction rates follow any observable trends. This abstract hones in on transient uncertainty quantification, in order to compare observed data against models for transient behavior. The first section of the paper uses linear regression tools to fit operational data, while the latter portion of the paper explores more complex simulation tools to fit operational data. Ultimately, the BEAVRS benchmark aims to serve as a true non-proprietary international benchmark for the validation of high-fidelity tools. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Passive scheme with a photon-number-resolving detector for monitoring the untrusted source in a plug-and-play quantum-key-distribution system

A passive scheme with a beam splitter and a photon-number-resolving (PNR) detector is proposed to verify the photon statistics of an untrusted source in a plug-and-play quantum-key-distribution system by applying a three-intensity decoy-state protocol. The practical issues due to statistical fluctuation and detection noise are analyzed. The simulation results show that the scheme can work efficiently when the total number of optical pulses sent from Alice to Bob is above 10{sup 8}, and the dark count rate of the PNR detector is below 0.5 counts/pulse, which is realizable with current techniques. Furthermore, we propose a practical realization of the PNR detector with a variable optical attenuator combined with a threshold detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE SPIN-DOWN OF SWIFT J1822.3-1606: A NEW GALACTIC MAGNETAR

On 2011 July 14, a new magnetar candidate, Swift J1822.3-1606, was identified via a rate trigger on the Swift/Burst Alert Telescope. Here we present an initial analysis of the X-ray properties of the source, using data from the Rossi X-ray Timing Explorer, Swift, and the Chandra X-ray Observatory, spanning 2011 July 16-October 8. We measure a precise spin period of P = 8.43771968(6) s and a spin-down rate of P-dot =2.54(22) Multiplication-Sign 10{sup -13}, at MJD 55761.0, corresponding to an inferred surface dipole magnetic field of B = 4.7(2) Multiplication-Sign 10{sup 13} G, the second lowest thus far measured for a magnetar, though similar to those of 1E 2259+586 and several high-magnetic field radio pulsars. We show that the flux decay in the 1-10 keV band is best fit by a double exponential with timescales of 9 {+-} 1 and 55 {+-} 9 days. The pulsed count rate decay in the 2-10 keV band, by contrast, is better fit by a single exponential decay with timescale 15.9 {+-} 0.2 days. After increasing from {approx}35% for {approx}20 days after the onset of the outburst, the pulsed fraction in the 2-10 keV band remained constant at {approx}45%. We argue that these properties confirm this source to be a new member of the class of objects known as magnetars. We consider the distribution of magnetar periods and inferred dipole magnetic field strengths, showing that the former appears flat in the 2-12 s range, while the latter appears peaked in the 10{sup 14}-10{sup 15} G range.

79 ASTRONOMY AND ASTROPHYSICS↗

Temporal dependence of transient dark counts in an avalanche photodiode: A solution for power-law behavior of afterpulsing

This paper offers a theoretical explanation of the temperature and temporal dependencies of transient dark count rates (DCRs) measured for a linear-mode silicon avalanche photodiode (APD) and the dependencies of afterpulsing that were measured in Geiger-mode Si and InGaAs/InP APDs. The temporal dependencies exhibit power-law behavior, at least to some extent. For the transient DCR, the value of the DCR for a given time period increases with decreases in temperature, while the power-law behavior remains unchanged. The transient DCR is attributed to electron emissions from traps in the multiplication layer of the APD with a high electric field, and its temporal dependence is explained by a continuous change in the electron emission rate as a function of the electric field strength. The electron emission rate is calculated using a quantum model for phonon-assisted tunnel emission. We applied the theory to the temporal dependence of afterpulsing that was measured for Si and InGaAs/InP APDs. The power-law temporal dependence is attributed to the power-law function of the electron emission rate from the traps as a function of their position across the p–n junction of the APD. Deviations from the power-law temporal dependence can be derived from the upper and lower limits of the electric field strength.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Second-order Talbot effect with entangled photon pairs

The second-order Talbot effect is analyzed for a periodic object illuminated by entangled photon pairs in both the quantum imaging and quantum lithography configurations. The Klyshko picture is applied to describe the quantum imaging scheme, in which self-images of the object that may or may not be magnified can be observed nonlocally in the photon coincidences but not in the singles count rate. In the quantum lithography setup, we find that the second-order Talbot length is half that of the classical first-order case, thus the resolution may be improved by a factor of 2.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hybrid Enrichment Verification Array: Module Characterization Studies

The work presented in this report is focused on the characterization and refinement of the Hybrid Enrichment Verification Array (HEVA) approach, which combines the traditional 186-keV 235 U signature with high-energy prompt gamma rays from neutron capture in the detector and surrounding collimator material, to determine the relative enrichment and 235 U mass of the cylinder. The design of the HEVA modules (hardware and software) deployed in the current field trial builds on over seven years of study and evolution by PNNL, and consists of a ø3''×3'' NaI(Tl) scintillator coupled to an Osprey digital multi-channel analyzer tube base from Canberra. The core of the HEVA methodology, the high-energy prompt gamma-ray signature, serves as an indirect method for the measurement of total neutron emission from the cylinder. A method for measuring the intrinsic efficiency of this “non-traditional” neutron signature and the results from a benchmark experiment are presented. Also discussed are potential perturbing effects on the non-traditional signature, including short-lived activation of materials in the HEVA module. Modeling and empirical results are presented to demonstrate that such effects are expected to be negligible for the envisioned implementation scenario. In comparison to previous versions, the new design boosts the high-energy prompt gamma-ray signature, provides more flexible and effective collimation, and improves count-rate management via commercially available pulse-processing electronics with a special modification prompted by PNNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bi-Modal Model for Neutron Emissions from PuO{sub 2} and MOX Holdup

The measurement of uranium and plutonium holdup in plants during process activity and for decommissioning is important for nuclear safeguards and material control. The amount of plutonium and uranium holdup in glove-boxes, pipes, ducts, and other containers has been measured for several decades using both neutron and gamma-ray techniques. For the larger containers such as hot cells and glove-boxes that contain processing equipment, the gamma-ray techniques are limited by self-shielding in the sample as well as gamma absorption in the equipment and associated shielding. The neutron emission is more penetrating and has been used extensively to measure the holdup for the large facilities such as the MOX processing and fabrication facilities in Japan and Europe. In some case the totals neutron emission rates are used to determine the holdup mass and in other cases the coincidence rates are used such as at the PFPF MOX fabrication plant in Japan. The neutron emission from plutonium and MOX has 3 primary source terms: 1) Spontaneous fission (SF) from the plutonium isotopes, 2) The (α,n) reactions from the plutonium alpha particle emission reacting with the oxygen and other impurities, and 3) Neutron multiplication (M) in the plutonium and uranium as a result of neutrons created by the first two sources. The spontaneous fission yield per gram is independent of thickness, whereas, the above sources 2) and 3) are very dependent on the thickness of the deposit. As the effective thickness of the deposit becomes thin relative to the alpha particle range, the (α,n) reactions and neutrons from multiplication (M) approach zero. In any glove-box, there will always be two primary modes of holdup accumulation, namely direct powder contact and non-contact by air dispersal. These regimes correspond to surfaces in the glove-box that have come into direct contact with the process MOX powder versus surface areas that have not had direct contact with the powder. The air dispersal of PuO{sub 2} particles has been studied for several decades by health physicists, because the primary health hazard of plutonium is breathing the airborne particles. The air dispersal mechanism results from the smaller particles in the top layer of powder that are lifted into the air by the electrostatic charge buildup from the alpha decay process, and the air convection carries the particles to new more distant locations. If there is open plutonium powder in a glove-box, the surfaces at more distant locations will become contaminated over time. The range of an alpha particle in a solid or powder is a function of the particle energy, the material density, and the atomic number A of the material. The average energy of a plutonium alpha particle is ∼5.2 MeV and the range in air is ∼37 mm. The range in other materials can be estimated via the Bragg-Kleenman equation. For plutonium, A is 94, and the typical density for a single particle is ∼11.5 g/cm{sup 3}, but for a powder, the density would be less because of the air packing fraction. The significance of the small diameter is that the range of the alpha particle is ∼50 μm for powder density 2.5 and significantly less for a single particle with density 11.5, so the thin deposit of separate small particles will have a greatly reduced (α,n) yield. The average alpha transit length to the surface in the isolated MOX particle would be < 2.5 μm; whereas, the range of the alpha particle is much longer. Thus, most of the alpha particles would escape from the MOX particle and be absorbed by the walls and air. The air dispersal particles will have access to a large surface area that includes the walls, whereas, the powder contact surface area will be orders of magnitude smaller. Thus, the vast majority of the glove-box surface area does not produce the full (α,n) reaction neutron yield, even from the O{sub 2} in the PuO{sub 2} as well as any impurity contamination such as H{sub 2}O. To obtain a more quantitative estimate of the neutron (α,n) yields as a function of holdup deposit thickness, we have used MCNPX calculations to estimate the absorption of alpha particles in PuO{sub 2} holdup deposits. The powder thickness was varied from 0.1 μm to 5000 μm and the alpha particle escape probability was calculated. As would be expected, as the thickness approaches zero, the escape probability approaches 1.0, and as the thickness gets much greater than the alpha particle range (∼50 μm), the escape probability becomes small. Typically, the neutron holdup calibration measurement are performed using sealed containers of thick MOX that has all 3 sources of neutrons [SF, (α,n), and M], and no significant impurities. Thus, the calibration counting rates need to include corrections for M and (α,n) yields that are different for the holdup compared with the calibration samples. If totals neutron counting is used for the holdup measurements, the variability of the (α,n) term needs to be considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of molecular sensitivity in positron emission tomography with quantum correlation of γ-ray photons

Enhancement of molecular sensitivity in positron emission tomography (PET) has long been discussed with respect to imaging instrumentation and algorithms for data treatment. Here, the molecular sensitivity in PET is discussed on the basis of 2-dimensional coincident measurements of 511 keV γ ray photons resultant from two-photon annihilation. Introduction of an additional selection window based on the energy sum and difference of the coincidently measured γ ray photons, without any significant instrumental and algorithmic changes, showed an improvement in the signal-to-noise ratio (SNR) by an order of magnitude. Improvement of performance characteristics in the PET imaging system was demonstrated by an increase in the noise equivalent count rate (NECR) which takes both the SNR and the detection efficiency into consideration. A further improvement of both the SNR and the NECR is expected for the present system in real clinical and in-vivo environments, where much stronger positron sources are employed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

METHODS FOR ESTIMATING FLUXES AND ABSORPTIONS OF FAINT X-RAY SOURCES

X-ray sources with very few counts can be identified with low-noise X-ray detectors such as the Advanced CCD Imaging Spectrometer on board the Chandra X-ray Observatory. These sources are often too faint for parametric spectral modeling using well-established methods such as fitting with XSPEC. We discuss the estimation of apparent and intrinsic broadband X-ray fluxes and soft X-ray absorption from gas along the line of sight to these sources, using nonparametric methods. Apparent flux is estimated from the ratio of the source count rate to the instrumental effective area averaged over the chosen band. Absorption, intrinsic flux, and errors on these quantities are estimated from comparison of source photometric quantities with those of high signal-to-noise spectra that were simulated using spectral models characteristic of the class of astrophysical sources under study. The concept of this method is similar to the long-standing use of color-magnitude diagrams in optical and infrared astronomy, with X-ray median energy replacing color index and X-ray source counts replacing magnitude. Our nonparametric method is tested against the apparent spectra of approx2000 faint sources in the Chandra observation of the rich young stellar cluster in the M 17 H II region. We show that the intrinsic X-ray properties can be determined with little bias and reasonable accuracy using these observable photometric quantities without employing often uncertain and time-consuming methods of nonlinear parametric spectral modeling. Our method is calibrated for thermal spectra characteristic of stars in young stellar clusters, but recalibration should be possible for some other classes of faint X-ray sources such as extragalactic active galactic nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral Evolution of Swift Gamma-ray Burst Tails: an Update

The detailed study of the spectral evolution during the steep decay phase of early X-ray light curves of Gamma-ray Bursts (GRBs) is a very important task that can give us information on different emission components contributing to the prompt-to-afterglow transition. Time resolved spectral analysis of bright GRBs detected by Swift has shown that a good modeling of the early X-ray light curves can be obtained with Band or cut-off power-law broad band spectra with evolving parameters (e.g., decaying peak energy). We developed a procedure to simultaneously fit the temporal evolution of all the spectral parameters of a GRB during the prompt to afterglow transition based on the analysis of the Swift Burst Alert Telescope (BAT) and the Swift X-ray Telescope (XRT) count rate and hardness ratio light curves. The procedure has been tested on GRB 060614 and GRB 090618, two very peculiar bright GRB detected by Swift that show a long exponentially decaying tail with strong softening and peak energy crossing the XRT energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

Spin-resolved photoelectron spectroscopy using femtosecond extreme ultraviolet light pulses from high-order harmonic generation

The fundamental mechanism responsible for optically induced magnetization dynamics in ferromagnetic thin films has been under intense debate since almost two decades. Currently, numerous competing theoretical models are in strong need for a decisive experimental confirmation such as monitoring the triggered changes in the spin-dependent band structure on ultrashort time scales. Our approach explores the possibility of observing femtosecond band structure dynamics by giving access to extended parts of the Brillouin zone in a simultaneously time-, energy- and spin-resolved photoemission experiment. For this purpose, our setup uses a state-of-the-art, highly efficient spin detector and ultrashort, extreme ultraviolet light pulses created by laser-based high-order harmonic generation. In this paper, we present the setup and first spin-resolved spectra obtained with our experiment within an acquisition time short enough to allow pump-probe studies. Further, we characterize the influence of the excitation with femtosecond extreme ultraviolet pulses by comparing the results with data acquired using a continuous wave light source with similar photon energy. In addition, changes in the spectra induced by vacuum space-charge effects due to both the extreme ultraviolet probe- and near-infrared pump-pulses are studied by analyzing the resulting spectral distortions. The combination of energy resolution and electron count rate achieved in our setup confirms its suitability for spin-resolved studies of the band structure on ultrashort time scales.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗