At least 487 records · Page 27

Influence of Insulation Monitoring Devices on the Operation of DC Control Circuits

The insulation level of DC control circuits is an important safety-critical factor and, thus, should be subject to continuous and periodic monitoring. The methods used for monitoring the insulation in live circuits may, however, disturb the reliable operation of control relays. The risks of misoperation and failure to reset of relays posed by the operation of various insulation monitoring and fault location systems are evaluated.

42 ENGINEERING↗

Hybrid spin Hall nano-oscillators based on ferromagnetic metal/ferrimagnetic insulator heterostructures

Abstract Spin-Hall nano-oscillators (SHNOs) are promising spintronic devices to realize current controlled GHz frequency signals in nanoscale devices for neuromorphic computing and creating Ising systems. However, traditional SHNOs devices based on transition metals have high auto-oscillation threshold currents as well as low quality factors and output powers. Here we demonstrate a new type of hybrid SHNO based on a permalloy (Py) ferromagnetic-metal nanowire and low-damping ferrimagnetic insulator, in the form of epitaxial lithium aluminum ferrite (LAFO) thin films. The superior characteristics of such SHNOs are associated with the excitation of larger spin-precession angles and volumes. We further find that the presence of the ferrimagnetic insulator enhances the auto-oscillation amplitude of spin-wave edge modes, consistent with our micromagnetic modeling. This hybrid SHNO expands spintronic applications, including providing new means of coupling multiple SHNOs for neuromorphic computing and advancing magnonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Data-Driven Voltage Control Strategy for Distribution Grids With Distributed Energy Resources

Traditionally, distribution system control approaches have been model-based. The deployment of advanced metering infrastructure has provided electric utilities with the capability of data-driven control with real-time measurements. The shift from model-based to data-driven control represents a significant advancement in the management of distribution systems, offering a more adaptive approach to system control because of the ability to dynamically adapt to changing conditions without the need for system modeling. Here, in this paper, a behavioral data-driven control method is developed to provide voltage regulation to an actual distribution system by controlling the legacy devices and distributed energy resource (DER) assets. The studied distribution system has a load tap changer and three capacitor banks as the legacy devices and photovoltaic systems as the DERs. The performance of the proposed control algorithm is validated using a laboratory test bed setup considering multiple scenarios. The results show that the proposed control achieved 99% voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Weather responsive smart ventilation system using multiple optimization parameters

A smart ventilation system which uses outdoor temperature and moisture to optimize control of the system. The main principle is to shift ventilation from time periods that have large indoor-outdoor temperature and moisture differences to periods when these differences are smaller, and their energy and comfort impacts are expected to be less. Fan flow rates are reduced when the outside temperature and moisture falls outside of optimum levels, yet overall air exchange is maintained to ensure chronic and acute exposure to pollutants remains relative to best practice. Online weather and smart thermostat data can be used as control inputs, so no specific measurement devices are needed to control ventilation fans.

Parker, Danny↗

Assessing Energy Infrastructure Devices for Vulnerabilities

Industrial control systems prove to be vital to the health and security of the nation in our critical infrastructure. Critical infrastructure includes the most foundational systems to support modern civilization which includes water and wastewater systems, communications, and the electricity we use to name a few sectors. However, these devices' overall composition remains largely unknown and are untested from a cyber security perspective. As part of the Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, I analyzed one such energy infrastructure device to better understand how it functions, what hardware and software components are present within it, and assess it for security vulnerabilities. To achieve this, I reverse engineered binary files using Ghidra to understand system functionality and learned more about how to collaborate with other researchers on a shared Ghidra project. I learned more about how web sockets function and how to interact with them through Python to test if they are secure or not. This work led me to assess possible vulnerabilities in this device and provide a better understanding of its composition and function, which are essential to INL's mission of securing our nation's energy infrastructure.

99 - GENERAL AND MISCELLANEOUS↗

Controlling the stability of both the structure and velocity of domain walls in magnetic nanowires

For magnetic nanowire devices, the precise control of both domain wall (DW) motion and pinning behaviour is essential for reliable functional performance. The domain wall velocity and wall structure are typically sensitive to the driving field or spin-polarized current, and the pinning behaviour depends on the walls' structure and chirality, leading to variability in behaviour. Here, a systematic study combining experimental measurements and micromagnetic simulations of planar nanowires with small fixed-angle structural modulations on both edges was undertaken to study the domain wall reversal regime. A phase diagram for the reversal field as a function of modulation amplitude was obtained that shows that three DW reversal regime. A range of field and modulation amplitudes were identified in which stable DW reversal occurs, where the wall velocity is constant as a function of field and the wall structure is stable, which is well suited to applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Policy-based secure communication with automatic key management for industrial control and automation systems

A method includes generating at least one access vector associated with a specified device in an industrial process control and automation system. The specified device has one of multiple device roles. The at least one access vector is generated based on one or more communication policies defining communications between one or more pairs of devices roles in the industrial process control and automation system, where each pair of device roles includes the device role of the specified device. The method also includes providing the at least one access vector to at least one of the specified device and one or more other devices in the industrial process control and automation system in order to control communications to or from the specified device.

47 OTHER INSTRUMENTATION↗

Inertia Emulation Control using Demand Response via 5G Communications

Building energy equipment is moving rapidly towards Internet of Things (IoT)-driven devices to provide consumer connectivity and device management. These device-level interfaces along with 5G communications will be leveraged to develop control architectures to engage a large number of monitoring and control devices and provide real-time and reliable energy services. Emerging 5G networks have high potential to provide the communication technology for demand response, with fast transfer speed, high reliability, and high number of connections. Guaranteed inertial response to limit frequency fluctuations is one of the main challenges in modern power systems due to the increased penetration of renewable generation, and it is largely affected by communication delays and packet losses. This paper analyzes inertial response and rate of change of frequency in a power system model with inverter-interfaced air conditioners. The control loop considers time delays and packet losses to show the need to switch to 5G networks in future smart grids.

Morovati, Samaneh↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A comparison of WEC control strategies

The operation of Wave Energy Converter (WEC) devices can pose many challenging problems to the Water Power Community. A key research question is how to significantly improve the performance of these WEC devices through improving the control system design. This report summarizes an effort to analyze and improve the performance of WEC through the design and implementation of control systems. Controllers were selected to span the WEC control design space with the aim of building a more comprehensive understanding of different controller capabilities and requirements. To design and evaluate these control strategies, a model scale test-bed WEC was designed for both numerical and experimental testing (see Section 1.1). Seven control strategies have been developed and applied on a numerical model of the selected WEC. This model is capable of performing at a range of levels, spanning from a fully-linear realization to varying levels of nonlinearity. The details of this model and its ongoing development are described in Section 1.2.

30 DIRECT ENERGY CONVERSION↗

Federation of UML models for cyber physical use cases

This method employs the concept of federation, which is defined as the use of existing models that represent aspects of a system in specific domains (such as physical and cyber security domains) and building interfaces to link all of domain models. Federation seeks to build on existing bodies of work. Some examples include the Common Information Models (CIM) maintained by the International Electrotechnical Commission Technical Committee 57 (IEC TC 57) for the electric power industry. Another relevant model is the CIM maintained by the Distributed Management Task Force (DMTF)? this CIM defines a representation of the managed elements in an Information Technology (IT) environment. The power system is an example of a cyber-physical system, where the cyber systems, consisting of computing infrastructure such as networks and devices, play a critical role in the operation of the underlying physical electricity delivery system. Measurements from remote field devices are relayed to control centers through computer networks, and the data is processed to determine suitable control actions. Control decisions are then relayed back to field devices. It has been observed that threat actors may be able to successfully compromise this cyber layer in order to impact power system operation. Therefore, future control center applications must be wary of potentially compromised measurements coming from field devices. In order to ensure the integrity of the field measurements, these applications could make use of compromise indicators from alternate sources of information such as cyber security. Thus, modern control applications may require access to data from sources that are not defined in the local information model. In such cases, software application interfaces will require integration of data objects from cross-domain data models. When incorporating or federating different domains, it is important to have subject matter experts work together, recognizing that not everyone has the same knowledge, responsibilities, focus, or skill set.

Source record↗

Resilience of High-Efficiency CdSeTe:As and CdSeTe:Cu Solar Cells to Proton Irradiation

Power generation in space is currently dominated by expensive III-V multi-junction photovoltaic (PV) devices and cheap crystalline silicon (c-Si) PV devices. Both of these technologies degrade rapidly in proton-radiation-rich space environments, such as the Van Allen belt. The present study of cadmium selenide telluride- (CdSeTe-) based PV devices exposed to 150-to-1500 keV proton irradiation with fluences up to 9 x 1013 cm-2 reveal a more radiation-hard alternative to III-V and c-Si PV technologies. We report on measurement and analysis of current density vs voltage (JV), external quantum efficiency (EQE), external radiative efficiency, and capacitance vs voltage (CV) characteristics. JV characteristics of As-doped CdSeTe devices show 80% remaining power conversion efficiency (PCE) relative to unexposed controls when exposed to 650 keV protons at a fluence of 1012 cm-2. Under these same irradiation conditions, Cu-doped CdSeTe devices demonstrate an even better 95% PCE retention compared with unirradiated control devices. Evidence of radiation-induced absorber p-type doping compensation is observed in the glass-side EQE at 0 V and CV characteristics of most of the irradiated CdSeTe:As devices, but clear compensation is evident only for the most heavily irradiated CdSeTe:Cu devices. Elevated blue-green photocurrent in the film-side 0 V EQE suggests a buried junction in the most heavily irradiated CdSeTe:As devices. Although CdSeTe:Cu devices are the more resilient of the CdSeTe structures, both CdSeTe-based technologies are radiation-hard when compared to c-Si and III-V multi-junction PV.

14 SOLAR ENERGY↗

Atomic-scale control of tunneling in donor-based devices

Atomically precise donor-based quantum devices are a promising candidate for solid-state quantum computing and analog quantum simulations. However, critical challenges in atomically precise fabrication have meant systematic, atomic scale control of the tunneling rates and tunnel coupling has not been demonstrated. Here using a room temperature grown locking layer and precise control over the entire fabrication process, we reduce unintentional dopant movement while achieving high quality epitaxy in scanning tunnelling microscope (STM)-patterned devices. Using the Si(100)2 × 1 surface reconstruction as an atomically-precise ruler to characterize the tunnel gap in precision-patterned single electron transistors, we demonstrate the exponential scaling of the tunneling resistance on the tunnel gap as it is varied from 7 dimer rows to 16 dimer rows. We demonstrate the capability to reproducibly pattern devices with atomic precision and a donor-based fabrication process where atomic scale changes in the patterned tunnel gap result in the expected changes in the tunneling rates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Unraveling the fundamental mechanisms of solvent-additive-induced optimization of power conversion efficiencies in organic photovoltaic devices

The realization of controllable morphologies of bulk heterojunction (BHJ) in organic photovoltics (OPVs) is one of the key factors in obtaining high-efficiency devices. Here via simultaneous monitoring of the three-dimensional nanostructural modifications in BHJ correlated with the optical analysis and theoretical modeling of charge transport, we provide new insights into the fundamental mechanisms essential for the optimization of (power conversion efficiency) PCEs with additive processing. Our results demonstrate how a trace amount of diiodooctane (DIO) remarkably changes the vertical phase morphology of the active layers resulting in formation of a well-mixed donor-acceptor compact film, augments charge transfer and PCEs. In contrast, excess amount of DIO promotes a massive reordering and results loosely packed mixed phase vertical phase morphology with large clusters leading to deterioration in PCEs. Theoretical modeling of charge transport reveals that DIO increases the mobility of electrons and holes (the charge carriers) by affecting the energetic disorder and electric field dependence of the mobility. Our results show the significant of phase separation and carrier transport pathways to achieve optimal device performances.

14 SOLAR ENERGY↗

Investigating Electric Field and Light Induced Degradation in Perovskite Solar Cells through Nanometer-Scale Potential Imaging

Electric field and light induced degradations in perovskite solar cells were evaluated through nanometer-scale potential imaging across the device by using in-situ Kelvin probe force microscopy (KPFM). We derived the electric field profile from potential profiles at different bias voltages to evaluate the locations and quality of junctions across the device. We found relative changes in electric field peak intensity at the HTL/perovskite and perovskite/ETL interfaces upon stressing devices separately under voltage or light. KPFM results during 12-hour stress/rest cycling under electrical bias show both reversible and irreversible changes in the device's interfacial fields. We also observed change in the electric field profile between control and degraded devices after 100 hours of stress/rest cycling under light. Our results demonstrate how nanometer-scale potential imaging can be used to understand the impacts of external electric fields and light soaking on both irreversible degradation and reversible metastability in perovskite solar cells.

Kelvin probe force microscopy↗

Attacking the IEC-61131 Logic Engine in Programmable Logic Controllers in Industrial Control Systems

In industrial control systems (ICS), programmable logic controllers (PLCs) directly monitor and control a physical process such as nuclear power plants, gas pipelines, and water treatment. They are equipped with a control logic written in IEC-61131 languages (e.g., ladder logic and structured text) that defines how a PLC should control a physical process. A PLC's control logic is a usual target of a cyberattack to sabotage a physical process. For instance, Stuxnet targets a control logic of a Siemens S7-300 PLC to damage a nuclear facility's centrifuges. The existing attacks in the literature generally focus only on injecting malicious control logic into a PLC. This paper presents a new dimension of control logic attacks that target the control logic engine (responsible for running a control logic) of a PLC. It demonstrates that a cyberattack can disable the control logic engine successfully by exploiting inherent PLC features such as program mode and starting/stopping engine. We develop two novel case studies on control logic engine attacks by employing the MITRE ATT\&CK knowledge base on the real-world PLCs used in industry settings, i.e., 1) Schweitzer Engineering Laboratory (SEL)'s Real-Time Automation Controller (SEL-3505 RTAC) equipped with security features such as encrypted traffic and device-level access control, and 2) traditional PLCs, i.e., Schneider Electric's Modicon M221, Allen-Bradley's MicroLogix 1400 and 1100 that do not have security features. The case studies present the internals of the logic engine attacks and facilitate the ICS research community and industry to understand the attack vectors on the control logic engine. We evaluate the effectiveness of the control engine attacks on a power substation, a 4-floor elevator, and a conveyor belt to demonstrate their real-world impact of halting a physical process.

Ali qasim, Syed↗