Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONSULTANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

WE-D-204-04: Learning the Ropes: Clinical Immersion in the First Month of Residency

Speakers in this session will present overview and details of a specific rotation or feature of their Medical Physics Residency Program that is particularly exceptional and noteworthy. The featured rotations include foundational topics executed with exceptional acumen and innovative educational rotations perhaps not commonly found in Medical Physics Residency Programs. A site-specific clinical rotation will be described, where the medical physics resident follows the physician and medical resident for two weeks into patient consultations, simulation sessions, target contouring sessions, planning meetings with dosimetry, patient follow up visits, and tumor boards, to gain insight into the thought processes of the radiation oncologist. An incident learning rotation will be described where the residents learns about and practices evaluating clinical errors and investigates process improvements for the clinic. The residency environment at a Canadian medical physics residency program will be described, where the training and interactions with radiation oncology residents is integrated. And the first month rotation will be described, where the medical physics resident rotates through the clinical areas including simulation, dosimetry, and treatment units, gaining an overview of the clinical flow and meeting all the clinical staff to begin the residency program. This session will be of particular interest to residency programs who are interested in adopting or adapting these curricular ideas into their programs and to residency candidates who want to learn about programs already employing innovative practices. Learning Objectives: To learn about exceptional and innovative clinical rotations or program features within existing Medical Physics Residency Programs. To understand how to adopt/adapt innovative curricular designs into your own Medical Physics Residency Program, if appropriate.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-00: Advances in Image-Guided Neurointerventions-Clinical Pull and Technology Push

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-01: Parallels in the Evolution of X-Ray Angiographic Systems and Devices Used for Minimally Invasive Endovascular Therapy

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-02: Advances in Cone Beam CT Anatomical and Functional Imaging in Angio-Suite to Enable One-Stop-Shop Stroke Imaging Workflow

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-03: Recent Advances in Devices Used in Neuro--Interventions

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-04: Advances in Radiological Neuro-Endovascular Interventional Imaging

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

TH-AB-201-07: Filmless Treatment Localization QA for the CyberKnife System

Purpose: Accuray recommends daily evaluation of the treatment localization and delivery systems (TLS/TDS) of the CyberKnife. The vendor-provided solution is a Winston-Lutz-type test that evaluates film shadows from an orthogonal beam pair (known as AQA). Since film-based techniques are inherently inefficient and potentially inconsistent and uncertain, this study explores a method which provides a comparable test with greater efficiency, consistency, and certainty. This test uses the QAStereoChecker (QASC, Standard Imaging, Inc., Middleton, WI), a high-resolution flat-panel detector with coupled fiducial markers for automated alignment. Fiducial tracking is used to achieve high translational and rotational position accuracy. Methods: A plan is generated delivering five circular beams, with varying orientation and angular incidence. Several numeric quantities are calculated for each beam: eccentricity, centroid location, area, major-axis length, minor-axis length, and orientation angle. Baseline values were acquired and repeatability of baselines analyzed. Next, errors were induced in the path calibration of the CK, and the test repeated. A correlative study was performed between the induced errors and quantities measured using the QASC. Based on vendor recommendations, this test should be able to detect a TLS/TDS offset of 0.5mm. Results: Centroid shifts correlated well with induced plane-perpendicular offsets (p < 0.01). Induced vertical shifts correlated best with the absolute average deviation of eccentricities (p < 0.05). The values of these metrics which correlated with the threshold of 0.5mm induced deviation were used as individual pass/fail criteria. These were then used to evaluate induced offsets which shifted the CK in all axes (a clinically-realistic offset), with a total offset of 0.5mm. This test provided high and specificity and sensitivity. Conclusion: From setup to analysis, this filmless TLS/TDS test requires 4 minutes, as opposed to 15–20 minutes for film-based methods. The techniques introduced can potentially isolate errors in individual joints of the CK robot. Spectrum Medical Physics, LLC of Greenville, SC has a consulting contract with Standard Imaging of Middleton, WI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-EF-BRC-00: TG-100 Workshop

This Hands-on Workshop will be focused on providing participants with experience with the principal tools of TG 100 and hence start to build both competence and confidence in the use of risk-based quality management techniques. The three principal tools forming the basis of TG 100’s risk analysis: Process mapping, Failure-Modes and Effects Analysis and fault-tree analysis will be introduced with a 5 minute refresher presentation and each presentation will be followed by a 30 minute small group exercise. An exercise on developing QM from the risk analysis follows. During the exercise periods, participants will apply the principles in 2 different clinical scenarios. At the conclusion of each exercise there will be ample time for participants to discuss with each other and the faculty their experience and any challenges encountered. Learning Objectives: To review the principles of Process Mapping, Failure Modes and Effects Analysis and Fault Tree Analysis. To gain familiarity with these three techniques in a small group setting. To share and discuss experiences with the three techniques with faculty and participants. Director, TreatSafely, LLC. Director, Center for the Assessment of Radiological Sciences. Occasional Consultant to the IAEA and Varian.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRC-01: Process Mapping

This Hands-on Workshop will be focused on providing participants with experience with the principal tools of TG 100 and hence start to build both competence and confidence in the use of risk-based quality management techniques. The three principal tools forming the basis of TG 100’s risk analysis: Process mapping, Failure-Modes and Effects Analysis and fault-tree analysis will be introduced with a 5 minute refresher presentation and each presentation will be followed by a 30 minute small group exercise. An exercise on developing QM from the risk analysis follows. During the exercise periods, participants will apply the principles in 2 different clinical scenarios. At the conclusion of each exercise there will be ample time for participants to discuss with each other and the faculty their experience and any challenges encountered. Learning Objectives: To review the principles of Process Mapping, Failure Modes and Effects Analysis and Fault Tree Analysis. To gain familiarity with these three techniques in a small group setting. To share and discuss experiences with the three techniques with faculty and participants. Director, TreatSafely, LLC. Director, Center for the Assessment of Radiological Sciences. Occasional Consultant to the IAEA and Varian.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRC-02: FMEA

This Hands-on Workshop will be focused on providing participants with experience with the principal tools of TG 100 and hence start to build both competence and confidence in the use of risk-based quality management techniques. The three principal tools forming the basis of TG 100’s risk analysis: Process mapping, Failure-Modes and Effects Analysis and fault-tree analysis will be introduced with a 5 minute refresher presentation and each presentation will be followed by a 30 minute small group exercise. An exercise on developing QM from the risk analysis follows. During the exercise periods, participants will apply the principles in 2 different clinical scenarios. At the conclusion of each exercise there will be ample time for participants to discuss with each other and the faculty their experience and any challenges encountered. Learning Objectives: To review the principles of Process Mapping, Failure Modes and Effects Analysis and Fault Tree Analysis. To gain familiarity with these three techniques in a small group setting. To share and discuss experiences with the three techniques with faculty and participants. Director, TreatSafely, LLC. Director, Center for the Assessment of Radiological Sciences. Occasional Consultant to the IAEA and Varian.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRC-03: Fault Tree Analysis

This Hands-on Workshop will be focused on providing participants with experience with the principal tools of TG 100 and hence start to build both competence and confidence in the use of risk-based quality management techniques. The three principal tools forming the basis of TG 100’s risk analysis: Process mapping, Failure-Modes and Effects Analysis and fault-tree analysis will be introduced with a 5 minute refresher presentation and each presentation will be followed by a 30 minute small group exercise. An exercise on developing QM from the risk analysis follows. During the exercise periods, participants will apply the principles in 2 different clinical scenarios. At the conclusion of each exercise there will be ample time for participants to discuss with each other and the faculty their experience and any challenges encountered. Learning Objectives: To review the principles of Process Mapping, Failure Modes and Effects Analysis and Fault Tree Analysis. To gain familiarity with these three techniques in a small group setting. To share and discuss experiences with the three techniques with faculty and participants. Director, TreatSafely, LLC. Director, Center for the Assessment of Radiological Sciences. Occasional Consultant to the IAEA and Varian.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRC-04: Quality Management Program

This Hands-on Workshop will be focused on providing participants with experience with the principal tools of TG 100 and hence start to build both competence and confidence in the use of risk-based quality management techniques. The three principal tools forming the basis of TG 100’s risk analysis: Process mapping, Failure-Modes and Effects Analysis and fault-tree analysis will be introduced with a 5 minute refresher presentation and each presentation will be followed by a 30 minute small group exercise. An exercise on developing QM from the risk analysis follows. During the exercise periods, participants will apply the principles in 2 different clinical scenarios. At the conclusion of each exercise there will be ample time for participants to discuss with each other and the faculty their experience and any challenges encountered. Learning Objectives: To review the principles of Process Mapping, Failure Modes and Effects Analysis and Fault Tree Analysis. To gain familiarity with these three techniques in a small group setting. To share and discuss experiences with the three techniques with faculty and participants. Director, TreatSafely, LLC. Director, Center for the Assessment of Radiological Sciences. Occasional Consultant to the IAEA and Varian.

60 APPLIED LIFE SCIENCES↗

Sci-Thur PM – Colourful Interactions: Highlights 05: Opal–the Oncology Patient Application

We describe Opal (Oncology portal and application), the mobile phone app and patient portal that we have developed and are deploying for Radiation Oncology patients at our cancer centre. Opal is a novel tool to empower patients with their own personal medical data, including appointment schedules, consultation notes, test results, radiotherapy treatment planning information and wait time management. Furthermore, due to its integration with our electronic medical record and treatment planning database, Opal will allow us to collect patient reported outcomes from consenting patients and link them directly with dose volume histograms and other treatment data.

60 APPLIED LIFE SCIENCES↗

Sci-Fri AM: Quality, Safety, and Professional Issues 04: Predicting waiting times in Radiation Oncology using machine learning

We describe a method for predicting waiting times in radiation oncology. Machine learning is a powerful predictive modelling tool that benefits from large, potentially complex, datasets. The essence of machine learning is to predict future outcomes by learning from previous experience. The patient waiting experience remains one of the most vexing challenges facing healthcare. Waiting time uncertainty can cause patients, who are already sick and in pain, to worry about when they will receive the care they need. In radiation oncology, patients typically experience three types of waiting: Waiting at home for their treatment plan to be prepared Waiting in the waiting room for daily radiotherapy Waiting in the waiting room to see a physician in consultation or follow-up These waiting periods are difficult for staff to predict and only rough estimates are typically provided, based on personal experience. In the present era of electronic health records, waiting times need not be so uncertain. At our centre, we have incorporated the electronic treatment records of all previously-treated patients into our machine learning model. We found that the Random Forest Regression model provides the best predictions for daily radiotherapy treatment waiting times (type 2). Using this model, we achieved a median residual (actual minus predicted value) of 0.25 minutes and a standard deviation residual of 6.5 minutes. The main features that generated the best fit model (from most to least significant) are: Allocated time, median past duration, fraction number and the number of treatment fields.

60 APPLIED LIFE SCIENCES↗

Virus species names have been standardized; virus names remain unchanged

Virus taxonomy, comprising classification and nomenclature, is regulated by the International Committee on Taxonomy of Viruses (ICTV). Taxon names are standardized to facilitate recognition and communication, with defined suffixes for each rank (e.g., the names of orders, families, and genera end in -virales, -viridae, and -virus, respectively). However, until recently, a standard format for species names was lacking. In 2021, following extensive discussion and community consultation, the ICTV decided to adopt a standardized binomial (Linnaean) format for virus species names, consisting of the genus name followed by a "freeform" species epithet. Previously assigned virus species names that were non-compliant with the binomial format have been fully updated. In contrast to taxon names regulated by the ICTV, the names of viruses, or "common" names, such as yellow fever virus or human immunodeficiency virus, are not under the remit of the ICTV and have not been changed.

Zerbini, F Murilo↗

Neutrinos: Determination of masses and mixing

The purpose of these lectures is to quantitatively summarize the present status of the determination of the massesand mixing of neutrinos. The field of neutrino phenomenology and its forward-looking perspectives is rapidly evolving and these lectures are only a partial introduction. For more details I suggest to consult the review articles [1–12], and text books [13–19].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards Rapid Interactive Machine Learning: Evaluating Tradeoffs of Classification without Representation

Our contribution is the design and evaluation of an interac- tive machine learning interface that rapidly provides the user with model feedback after every interaction. To address visual scalability, this interface communicates with the user via a “tip of the iceberg” approach, where the user interacts with a small set of recommended instances for each class. To address computational scalability, we developed an O(n) classification algorithm that incorporates user feedback incrementally, and without consulting the underlying data’s representation matrix. Our computational evaluation showed that this algorithm has similar accuracy to several off-the-shelf classification algo- rithms with small amounts of labeled data. Empirical evalu- ation revealed that users performed better using our design compared to an equivalent active learning setup.

Arendt, Dustin L.↗

Climate Services for Agriculture: Tools for Informing Decisions Relating to Climate Change and Climate Variability in the Wine Industry

Australia’s changing climate is already impacting the agriculture sector and will continue to do so in the future. To help respond to these impacts, the Climate Services for Agriculture (CSA) platform presents readily accessible climate data, including future climate projections, relevant to specific agricultural commodities. This wine industry example aims to demonstrate the functionality and utility of the CSA for national use across a broad range of commodities. Methods and Results. The platform includes commodity-relevant climate indices designed in consultation with experts to ensure that they are as salient to producers as possible; the wine-grape specific indices include measures of growing season temperature, rainfall, extreme heat, and frost. Here, we describe the research behind the wine-grape specific indices and present sample outputs from the CSA platform for a site within a selected winegrowing region. We note the CSA platform has been developed through an extensive and continuing user engagement initiative, ensuring it meets the needs of the agriculture community as they grapple with how to make decisions based on longer term climate projections. Conclusions. Provision of past, seasonal outlook, and future climate information for Australia and for a range of important agricultural commodities can help improve on-farm planning and decision-making to respond to climate risks. The wine industry provides a leading example of how to use these data for decision-making, noting ongoing adjustments will be needed. Significance of the Study. The CSA platform brings together historical climate data, seasonal climate outlooks, and future climate projections to assist agricultural producers to better manage climate variability and climate change. It aims to nationalise this information for all major agricultural commodities in Australia. We use wine production as a demonstration case here.

54 ENVIRONMENTAL SCIENCES↗