Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONDENSATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Off-Gas Condensate and Cast Stone Analysis Results

A sample of off-gas condensate produced during a demonstration test of the direct-feed low-activity waste (DFLAW) Radioactive Waste Test Platform using waste retrieved from Hanford storage tank AP-105 waste was analyzed for major cations, anions, total cyanide, Resource Conservation and Recovery Act (RCRA) metals, selected radionuclides, and selected organic compounds. The remaining off-gas condensate was concentrated through evaporation and then used to produce Cast Stone waste forms. After the solid waste forms cured for 28 days, U.S. Environmental Protection Agency (EPA) Method 1311 (EPA 1992) Toxicity Characteristic Leach Procedure (TCLP) tests were conducted on two samples. The TCLP leachates were analyzed for RCRA metals, fluoride, and total cyanide. These chemical analyses were conducted to collect data on the waste form performance and to determine if the waste form will meet the disposal requirements of the Waste Control Specialists LLC (WCS) Federal Waste Disposal Facility (FWF) in Texas (WCS 2015) and the Integrated Disposal Facility at Hanford. The radionuclide results in the off-gas condensate were used to estimate concentrations in the Cast Stone waste forms; these estimates were then compared to Class C limits (30 TAC 336.362 Appendix E). With the possible exception of U-232, all measured radionuclides were determined to be below their respective Class C limits. Inductively coupled plasma-mass spectrometry (ICP-MS) was used to measure most of the radionuclides. It is not possible to differentiate the isotope measured at mass 232 between U 232 and Th-232 by mass spectroscopy. Class C limit comparisons were made by assuming two maximum possible scenarios; one in which all the isotope at mass 232 occurred as Th-232, and another assigning the entire mass contribution to U-232. If the isotope at mass 232 is all Th-232 then the waste form is well below its Class C limit; however, if the isotope at mass 232 is all U-232, then the Class C limit would be exceeded by more than a factor of 8. A chemical procedure to separate uranium from thorium followed by reanalysis by ICP-MS would be required to resolve this issue. A similar issue occurs at mass 238, which could be U-238 or Pu-238; however, in this case Pu-238 can be ruled out as a contributor to the isotope measured at mass 238 for the following reasons. Pu-238 has a half-life of 87.7 years and its daughter product (U-234) has a half-life of 2.5 × 105 years and a measured concentration of < 0.002 µg/L. If significant concentrations of Pu-238 were present in this waste, then the amount of measurable U 234 would have increased over the decades of storage in the Hanford tanks. Because this was not observed, it is concluded that the isotope measured at mass 238 is all U-238. A total of 68 organic compounds were targeted for analysis in the off-gas condensate. Of these compounds, only nine were measured above their respective minimum reportable concentration. These compounds were acenaphthene, acetone, n-butyl alcohol, p,p’-DDT, methyl ethyl ketone, nitrobenzene, o nitrophenol, pyridine, and toluene. Of the detectable compounds, only acenaphthene, acetone, o nitrophenol, and pyridine were above wastewater standards (40 CFR 268.48 - Universal Treatment Standards). None of the organic compounds exceeded the non-wastewater standards (40 CFR 268.48 - Universal Treatment Standards). Analysis of the TCLP leachates from the Cast Stone waste forms indicated that none of the analytes exceeded the Universal Treatment Standard and, in general, all were well below the standards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of High Rotor Pole Switched Reluctance Motors to Control Condenser Fans in a Commercial Refrigeration System

A high rotor pole switched reluctance motor (HRSRM) designed by Software Motor Corporation was evaluated for use as a condenser fan motor due to its reported high motor efficiency over a broad range of speeds and added advanced control potential. The project was split into two phases; the first of which was to determine the direct energy savings due to the increased motor efficiency, the second was to leverage the additional benefits of the energy efficiency measure (EEM) to create additional energy savings. This report only discusses results from the first phase of the project. Nine 1.5hp HRSRMs were installed parallel to the same number of legacy induction motors of a supermarket commercial refrigeration system located in Lakeside, Colorado. At this site, the 1.5 hp legacy motors had historically adjusted condenser fan speed from 200-870 rpm based on outdoor air temperature and compressor discharge pressure. This type of control is known as variable head pressure control (VHPC). These nine new motors were given a signal from the legacy variable frequency drive (VFD) to match the motor speed of the legacy motors. Determination of the energy savings of the EEM was performed over a two-month period, at which time a correlation between legacy and EEM power consumption was developed based on motor speed. Annual data that had been collected from 2016-2017 (before the two-month test period) was then leveraged to predict the annual energy savings of the EEM for a complete retrofit using both VHPC and constant fan speed control. Table 1 displays the quantitative results. The EEM saved 27% of total energy consumption of the condenser fan motors for constant fan speed control, while the energy savings increased to 32% when using VHPC. This was due to the improved motor efficiency of the HRSR motor at low speeds. While the constant speed fan control kept the motors running at 870 rpm, VHPC adjusted fan speed between 200-870rpm based on the outdoor air temperature and the compressor discharge pressure. These savings are assuming a direct replacement with no additional controls. Retrofitting a constant speed fan control system with HRSRMs and switching to VHPC would provide significant energy savings looking at the condenser alone. Additional considerations of the EEM were noted during the project as well. The HRSRM system made it possible to identify and remotely shutdown an individual motor when a piece of foam locked the fan and thereby the motor. With the traditional system, a locked rotor could have caused motor damage unless a breaker or fuse was activated. Furthermore, due to vibration complaints from the installation technicians, the ramp-up time of the HRSRM had to be increased to a minute. After implementing this change no complaints for excessive vibration were recorded.

15 GEOTHERMAL ENERGY↗

Novel Patterned Surfaces for Improved Condenser Performance in Power Plants

In this project, we seek to improve the thermoelectric power plant performance through engi-neered nonwetting condenser tube surface designs that can enhance heat transfer performance by: (1) promoting dropwise condensation of the steam on the shell side and eliminating flooding of the surface structure by maintaining low droplet adhesion, thus increasing condensation heat transfer coefficient; (2) deterring fouling and corrosion, thereby reducing fouling resistance and improving heat transfer; (3) possibly reducing drag and increasing convective heat transfer inside coolant tubes; and (4) reducing the number of tubes, coolant water usage, and levelized cost of condenser.

20 FOSSIL-FUELED POWER PLANTS↗

Application of Heat Transfer Enhancement (HTE) System for Improved Efficiency of Power Plant Condensers

The mission of the National Energy Technology Laboratory (NETL), a U.S. laboratory under the Department of Energy, is to drive innovation and deliver solutions for an environmentally sustainable and prosperous energy future. Through the U.S. Department of Energy (DOE)/Fossil Energy’s (FE) Crosscutting Research Program, NETL funded Interphase Materials to develop and demonstrate a technology to improve power plant condenser efficiency. From 2018 through 2021, Interphase Materials developed THERMOPHASE, an advanced material applied to the condenser during plant operation to increase efficiency and lower fuel consumption, CO 2 emissions, and water withdrawal. THERMOPHASE was evaluated in controlled environments where improvements to heat transfer and a reduction in fouling were observed. THERMOPHASE was also applied to the main condenser of the Longview Power plant and changes to the plant performance were monitored. After two years following application of THERMOPHASE, a reduction in condenser back pressure of 0.26 ± 0.13 inHg was observed resulting in an estimated $3.35M in fuel savings, 136 million lbs. of decreased CO 2 emissions, and 1,287 million gallons reduced water withdrawal.

01 COAL, LIGNITE, AND PEAT↗

CONVECTION IN CONDENSIBLE-RICH ATMOSPHERES

Condensible substances are nearly ubiquitous in planetary atmospheres. For the most familiar case—water vapor in Earth’s present climate—the condensible gas is dilute, in the sense that its concentration is everywhere small relative to the noncondensible background gases. A wide variety of important planetary climate problems involve nondilute condensible substances. These include planets near or undergoing a water vapor runaway and planets near the outer edge of the conventional habitable zone, for which CO{sub 2} is the condensible. Standard representations of convection in climate models rely on several approximations appropriate only to the dilute limit, while nondilute convection differs in fundamental ways from dilute convection. In this paper, a simple parameterization of convection valid in the nondilute as well as dilute limits is derived and used to discuss the basic character of nondilute convection. The energy conservation properties of the scheme are discussed in detail and are verified in radiative-convective simulations. As a further illustration of the behavior of the scheme, results for a runaway greenhouse atmosphere for both steady instellation and seasonally varying instellation corresponding to a highly eccentric orbit are presented. The latter case illustrates that the high thermal inertia associated with latent heat in nondilute atmospheres can damp out the effects of even extreme seasonal forcing.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental and analytical investigation of 0 G condensation in a mechanical refrigeration system application

Basic equations of momentum and energy are presented and discussed with respect to heat transfer and pressure drop for forced flow condensation in horizontal tubes under 1-g and 0-g conditions. Some experimental results are presented for condensing refrigerant-12 in a system of three parallel-connected quartz tubes (3-mm inside diameter, G = 1.037 to 3.456 x 105 lbm/hr-sq. ft). From high speed photographs, measurements were obtained of film thickness, phase velocities, disturbance wavelengths, and flow regimes and their transitions. Based upon these measurements various dimensionless force ratios (flow and instability parameters) were calculated. Under 0-g conditions a uniformly thick redistribution of liquid condensate about the tube walls was found to result in a lowered heat transfer coefficient as compared with 1-g conditions, based upon fundamental heat transfer theory. A model is proposed that takes into account the difference in heat transfer due to condensate distribution under 1-g and 0-g conditions.

Keshock, E. G.↗

The effect of C/O ratio on the condensation of planetary material

The condensation temperatures of refractory silicates and oxides in a gas of cosmic composition are strongly dependent on the C/O ratio. As the ratio increases from 0.4 to 0.9, condensation temperatures of compounds such as Al2O3, Ca2Al2SiO7, MgAl2O4, Mg2SiO4, and MgSiO3 decrease by 50-100 degrees. As C/O increases from 0.9 to 1.0, these temperatures drop an additional 300-400 degrees. Other chemical differences result when C/O approximately equals or exceeds 0.9. A new suite of high-temperature minerals appears (graphite, CaS, Fe3C, SiC and TiN); the reaction CO + 3H2 yields CH4 + H2O proceeds to the right at higher temperatures; and iron, whose condensation temperature is unaffected, condenses at higher temperatures than any silicate or oxide.

Larimer, J. W.↗

Saturn's rings. II - Condensations of light and optical thickness of Cassini's division

Condensations of light have been observed when Saturn's rings are seen almost edge on, and the sun and the earth are on opposite sides of the ring plane. These condensations are associated with ring C and Cassini's division. If the relative brightness between the two condensations and the optical thickness of ring C are known, we can calculate the optical thickness of Cassini's division. Using Barnard's and Sekiguchi's measurements, we have obtained a range from .01 to .05 for the optical thickness of Cassini's division. A brightness profile of the condensations which agrees well with visual observations is also presented.

Ferrin, I. R.↗

Analysis of axially grooved heat pipe condensers

In an analytical study of the thermal behavior of the condenser section of a heat pipe with axial rectangular grooves under zero-g condition, the condensation rate was determined by studying the motion of the thin liquid film on the land area between grooves. It was found that the local condensation rate depends, among other factors, on the curvature of the liquid meniscus and on the shape of the land top. Computed overall heat transfer rate compares favorably with available experimental data. The liquid meniscus variation along the heat pipe length in the condenser section was also determined.

Kamotani, Y.↗

The possible role of solid surface area in condensation reactions during chemical evolution - Reevaluation

Using surface concentration and reaction rate as the main criteria for the feasibility of condensation reactions, four types of prebiotic environments were analyzed: (1) an ocean-sediment system, (2) a dehydrated lagoon bed produced by evaporation, (3) the surface of a frozen sediment, and (4) a fluctuating system where hydration (rainstorms, tidal variations, flooding) and dehydration (evaporation) take place in a cyclic manner. With the possible exception of nucleotides, low adsorption of organomonomers on sediment surfaces of a prebiotic ocean (pH 8) is expected, and significant condensation is considered unlikely. In dehydrated and frozen systems, high surface concentrations are probable and condensation is more likely. In fluctuating environments, condensation rates will be enhanced and the size distribution of the oligomers formed during dehydration may be influenced by a 'redistribution mechanism' in which adsorbed oligomers and monomers are desorbed and redistributed on the solid surface during the next hydration-dehydration cycle.

Lahav, N.↗

Condensation and its growth down the test-section of the Langley 0.3-m transonic cryogenic tunnel

Four total pressure probes were used to measure the growth of condensation down the test section of the Langley 0.3-m tunnel, and the condensation data were employed to verify a mathematical model which assumes condensation results from heterogeneous nucleation on preexisting seed particles. The onset of effects occurs throughout the test section at the same total temperature but the magnitude of the effects increases with increasing length down the test section. Condensation is important because it determines the minimum operating temperature of transonic cryogenic wind tunnels.

Hall, R. M.↗

An experimental investigation of the condensation of silicate grains

Results are presented for a series of laboratory experiments designed to investigate the nucleation of small silicate grains from a vapor of astrophysically significant elements and compounds. In the experiments, magnesium silicate grains were condensed by simultaneously evaporating Mg and SiO solids into an atmosphere of argon or hydrogen at a pressure of a few torr. The results show that at low temperatures (up to a few hundred degrees C) the condensates are amorphous grains and have widely varying stoichiometries. The thermodynamically most stable compounds (Mg2SiO4, MgSiO3, SiO2) do not form readily, but all initial condensates can be converted to crystalline forsterite (Mg2SiO4) by heating to 1000 C in vacuum. At higher temperatures (above 700 K) it becomes more difficult to nucleate any silicates, and those that do form are amorphous, indicating that surface energies and kinetic effects are very important in determining under what conditions condensation will occur. The IR spectra of the experimentally produced magnesium silicates are found to have a strong resemblance to those observed in many astronomical clouds.

Day, K. L.↗

On the comparison between equilibrium and disequilibrium condensation sequences of meteorites

A definition is presented of a simple formalism for calculating the condensation sequence of meteoritic minerals in a cooling vapor phase in temperature disequilibrium (between the vapor phase and the condensed phase) when such minerals condense congruently. Certain preliminary comments are made about the possibility of judging the relative plausibility of the equilibrium and the disequilibrium models from the observations in meteorites if a monotonic cooling were indeed the course of condensation in either case.

De, B. R.↗

Self-condensation of activated dinucleotides on polynucleotide templates with alternating sequences

Substantial quantities of the alternating polymers poly(U-G) and poly(C-A) have been prepared and used as templates for the self-condensation of ImpApC, ImpCpA, ImpGpU and ImpUpG. It is found that the condensation of ImpGpu and ImpUpG on poly(C-A) is efficient, the condensation of ImpCpA on poly(U-G) is moderately efficient, while the condensation of ImpApC on poly(U-C) proceeds poorly. In many cases, the product is predominantly 3'-5'-linked. These reactions demonstrate unequivocally, for the first time, that template-directed reactions occur in double-helical structures. Furthermore, they describe for the first time a pair of reactions in which each of two complementary polymers facilitates the synthesis of the other. The prebiotic significance of these findings is discussed.

Lohrmann, R.↗

Nucleation and condensation in the primitive solar nebula

It is pointed out that the primitive solar nebula may be modeled using the frictionally induced transport theory of Lynden-Bell and Pringle (1974) if the principal frictional mechanism within the nebula is turbulent viscosity. The present investigation is concerned with the construction of a model of a section of the primitive solar nebula as a basis for the study of nucleation and condensation processes within this section. The construction involves a relatively simple application of the Lynden-Bell and Pringle theory subject to steady mass flow conditions. The calculations which are conducted in connection with the investigation indicate that by the time the gas in the primitive solar nebula has become sufficiently supercooled to nucleate condensation centers, several different compounds, including the magnesium silicates forsterite and enstatite (MgSiO3), will probably be able to condense on the growing condensation center.

Cameron, A. G. W.↗

The function and response of an improved stratospheric condensation nucleus counter

An improved condensation nucleus counter (CNC) for use in the stratosphere is described. The University of Minnesota CNC (UMCNC) has a sequential saturator and condenser and uses n-butyl alcohol as the working fluid. The use of a coaxial saturator flow, with aerosol in the center and filtered, alcohol-laden air around it, speeds the response of this instrument and improves its stability as pressure changes. The counting efficiency has been studied as a function of particle size and pressure. The UMCNC provides an accurate measure of submicron aerosol concentration as long as the number distribution is not dominated by sub-0.02 micron diameter aerosol. The response of the UMCNC is compared with that of other stratospheric condensation nucleus counters, and the results of a (near) comparison with a balloon-borne condensation nucleus counter are presented. The UMCNC has operated 14 times on a NASA U-2 aircraft at altitudes from 8 to 21.5 km.

Wilson, J. C.↗

Pre-existing seed particles and the onset of condensation in cryogenic wind tunnels

The condensation research at NASA Langley Research Center has used a variety of experimental approaches to gather information on seed particles that can act as sites for condensation growth. Total pressure measurements have suggested that condensation growth is caused by impurities in the flow and not by unevaporated liquid nitrogen (LN2) droplets resulting from the LN2 injected to cool the 0.3-Meter Transonic Cryogenic Tunnel. A separate test with an optical droplet sizing probe, which was designed to detect droplets in the 2- to 300-micron range, confirmed the conclusions from the total pressure measurements and also discovered what appears to be solidified oil droplets having diameters of about 3 microns. These oil droplets appear to be the dominant source of seed particles above 2 microns. However, computer simulations of static pressure test data suggest that the measured condensation effects are the result of more numerous, smaller seeds with number densities on the order of 10 to the 12th per kilogram of the gas and diameters on the order of 0.5 microns.

Hall, R. M.↗