Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHLORIDES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Response to the comment “Uranyl-chloride speciation and uranium transport in hydrothermal brines: Comment on Migdisov et al. (2018)” by Dargent et al.

We welcome the comments provided by Dargent et al. (2018) and appreciate the effort they have made to evaluate our recently reported data on the stability of uranyl(VI) chloride complexes as function of temperature (Migdisov et al., 2018). We also appreciate the opportunity provided by the editor to clarify issues in our paper that were not clearly articulated or in error.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

An experimental study of the solubility and speciation of thorium in chloride-bearing aqueous solutions at temperatures up to 250 °C

In this study, the solubility and speciation of Th in Cl-bearing solutions saturated in ThO2 was investigated experimentally at 150, 175, 200, 225 and 250°C, and saturated water vapor pressure. At these experimental conditions (pH 25°C < 3.8, mNaCl < 2.5), Th-chloride complexation is insignificant, and the solubility of Th is controlled by hydrolysis. The two main species in solution were identified as Th(OH) 2 2+ and Th(OH) 4 ° and formed via the reactions Th 4+ + 2OH - ↔ Th(OH)$2+\atop{2}$ and Th 4+ + 4OH - ↔ Th(OH)$0\atop{4}$. The logarithms of the formation constants determined for the first reaction are 23.91 ± 0.05, 24.79 ± 0.07, 25.78 ± 0.05, and 25.85 ± 0.05 for 175, 200, 225 and 250°C, respectively, and 42.18 ± 0.06, 43.50 ± 0.07, 43.17 ± 0.08, and 43.74 ± 0.11 for the second reaction at the same temperatures. Formation constants could not be determined reliably for 150 °C. Extrapolations of our formation constants to 25°C are in excellent agreement with the values determined at 25 °C by Neck and Kim (2001) and Ekberg et al. (2000). Finally, for natural systems buffered by thorianite (ThO 2 ), the solubility determined in our study likely reflects a minimum, as the presence of additional ligands would lead to higher solubility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New crystal structural families of lanthanide chloride alcohol/water complexes

The exploration of lanthanide chloride compounds as possible scintillation materials for gamma ray and neutron detection has led to the discovery of several new families of crystal structures with the general formula LnCl3(CH3OH)x(H2O)y. The specific crystal structure depends on the water/methanol content and lanthanide ion. The coordination of the light (large) lanthanides is the typical value of 8 and reduces to 7 for the heavier (small) lanthanides. The binding energy of water versus alcohol ligands is comparable, so that if water is present in the system, it is typically incorporated as a ligand in the crystal. In these crystals, the molecular adducts occur as monomers, dimers, and dichloro-bridged chains. These, in turn, form 3-D frameworks through H-bonds to the Cl atoms. Other distinct crystal structures are predicted, given the volume changes due to the lanthanide contraction, the water content of the crystal growth solutions, and the specific halide.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal conductivity measurement using modulated photothermal radiometry for nitrate and chloride molten salts

Molten salts are being used or explored for thermal energy storage and conversion systems in concentrating solar power and nuclear power plants. Thermal conductivity of molten salts is an important thermophysical property dictating the performance and cost of these systems, but its accurate measurement has been challenging, as evidenced by wide scattering of existing data in literature. The corrosive and conducting nature of these fluids also leads to time consuming sample preparation processes of many contact-based measurements. Here, in this work, we report the measurement of thermal conductivity of molten salts using a modulated photothermal radiometry (MPR) technique, which is a laser-based, non-contact, frequency-domain method adopted for molten salts for the first time. By unitizing the advantages of front side sensing of frequency-domain measurements and the vertical holder orientation, the technique can minimize the natural convection and salt creeping effects, thus yielding accurate molten salt thermal conductivity . The MPR technique is first calibrated using standard molten materials including paraffin wax and sulfur. It is then applied on measuring pure nitrate salts (NaNO 3 and KNO 3 ), solar salt (NaNO 3 –KNO 3 mixture), and chloride salt (NaCl–KCl–MgCl 2 ). The measurement results are compared with data from literature, especially those obtained from laser flash analysis (LFA). Our results demonstrate that the MPR is a convenient and reliable technique of measuring thermal conductivity of molten salts. Accurate thermal conductivity data of molten salts will be valuable in developing the next-generation high-temperature thermal energy storage and conversion systems.

14 SOLAR ENERGY↗

Application of an orcinol-ferric chloride colorimetric assay in barley and wheat accessions for water-extractable and total arabinoxylan

Arabinoxylan is an important hemicellulose potentially affecting wheat baking qualities, barley malt quality, and may impart prebiotic benefits. Water-extractable (WEAX) and total arabinoxylan (TOAX) were characterized in 204 wheat and barley accessions, respectively, using an orcinol-ferric chloride assay. WEAX measurement accuracy was optimum when glucose concentration was greater than 12–13 times pentose concentration. The modified method removed enough excess glucose spectral absorbance to make the corrected and uncorrected lines different, but still significantly correlated (p = 0.009, R = 0.94). Mean WEAX (expressed as percentage WEAX of TOAX) for the wheat accessions was 15.90%, ranging from 8.82% to 24.87%, and for barley accessions WEAX the mean was 7.10%, and ranged from 2.98% to 13.86%. Conclusions are 1) the assay is useful for a breeding program because of its semi-high throughput design for the simultaneous analysis of 16 (WEAX) to 40 (TOAX) barley lines or 24 (WEAX) to 40 (TOAX) wheat lines, 2) the trichromatic measurement reduces the impact of glucose, and 3) the broad range of WEAX measured showed that barley and wheat accessions vary in their extractable and unextractable components.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of corrosion coupons exposed to molten-chloride electrorefiner salts long term

Corrosion mitigation has long been considered a challenge in long-term service of both pyrochemical reprocessing and molten salt reactor applications. Corrosion coupons consisting of 2.25Cr 1Mo ASME SA387 Grade 22 Class 2 steel, were installed in a uranium electrorefiner containing molten chloride salt at 500°C. This electrorefiner went into service at Idaho National Laboratory in 1994. Seven of these coupons were removed in 2019 (i.e., submerged in molten salt for 25 years) for analysis and characterization including neutron imaging, optical microscopy, scanning electron microscopy, and wave/energy dispersive x-ray spectroscopy. The results showed that all seven coupons experienced between 30 to 175 µm of surface degradation without evidence of brittle fracture. Meaning there was no evidence of accelerated corrosion or fractures, and the average steel surface loss was of less than 5 µm per year. All indications were that the environmental conditions inside the electrorefiner were favorable for the steel alloy.

36 - MATERIALS SCIENCE↗

Reversible Poisoning of the Nickel/Zirconia Solid Oxide Fuel Cell Anodes by Hydrogen Chloride in Coal Gas

The performance of anode-supported solid oxide fuel cells (SOFC) was evaluated in synthetic coal gas containing HCl in the temperature range 650 to 850oC. Exposure to up to 800 ppm HCl resulted in reversible poisoning of the Ni/zirconia anode by chlorine species adsorption, the magnitude of which decreased with increased temperature. Performance losses increased with the concentration of HCl to ~100 ppm, above which losses were insensitive to HCl concentration. Cell voltage had no effect on poisoning. No evidence was found for long-term degradation that can be attributed to HCl exposure. Similarly, no evidence of microstructural changes or formation of new solid phases as a result of HCl exposure was found. From thermodynamic calculations, solid nickel chloride phase formation was shown to be highly unlikely in coal gas. Further, the presence of HCl at even the highest anticipated concentrations in coal gas would minimally increase the volatility of nickel.

01 COAL, LIGNITE, AND PEAT↗

Novel ternary molten salt electrolytes for intermediate-temperature sodium/nickel chloride batteries

The sodium–nickel chloride (ZEBRA) battery is operated at relatively high temperature (250–350 °C) to achieve adequate electrochemical performance. Reducing the operating temperature in the range of 150200 °C can not only lead to enhanced cycle life by suppressing temperature-related degradations, but also allow the use of lower cost materials for construction. To achieve adequate electrochemical performance at lower operating temperatures, reduction in ohmic losses is required, including the reduced ohmic resistance of β"-alumina solid electrolyte (BASE) and the incorporation of low melting point secondary electrolytes. In present work, planar-type Na/NiCl 2 cells with a thin BASE (600 μm) and low melting point secondary electrolyte were evaluated at reduced temperatures. Molten salts used as secondary electrolytes were fabricated by the partial replacement of NaCl in the standard secondary electrolyte (NaAlCl 4 ) with other lower melting point alkali metal salts such as NaBr, LiCl, and LiBr. Electrochemical characterization of these ternary molten salts demonstrated improved ionic conductivity and sufficient electrochemical window at reduced temperatures. Furthermore, Na/NiCl 2 cells with 50 mol% NaBr-containing secondary electrolyte exhibited reduced polarizations at 175 °C compared to the cell with the standard NaAlCl 4 catholyte. Finally, the cells also exhibited stable cycling performance even at 150 °C.

reduced temperature↗

Strontium-copper selenite-chlorides: Synthesis and structural investigation

Two new complex selenite-chlorides of strontium and copper Sr{sub 2}Cu(SeO{sub 3}){sub 2}Cl{sub 2} (I) and SrCu{sub 2}(SeO{sub 3}){sub 2}Cl{sub 2} (II) were obtained and characterized by X-ray diffraction technique, DTA and IR spectroscopy. Both compounds crystallize in the monoclinic system I: Sp. gr. P2{sub 1}/n, a=5.22996(3) A, b=6.50528(4) A, c=12.34518(7) A, beta=91.3643(2){sup o}, Z=2; II: Sp. gr. P2{sub 1}, a=7.1630(14) A, b=7.2070(14) A, c=8.0430(16) A, beta=95.92(3){sup o}, Z=2. Comparison of the crystal structure of (I) with the structures of Sr{sub 2}M(SeO{sub 3}){sub 2}Cl{sub 2} (M=Co, Ni) was performed. The substitution of strontium atom in the structure of (I) by Cu{sup 2+} ion with a 3d{sup 9} Jahn-Teller distorted surrounding leads to the lowering of the structure symmetry and to the appearance of the noncentrosymmetric structure of (II). The noncentrosymmetric character of the structure of (II) was confirmed by SHG signal (1.2 units relative to an alpha-quartz powder sample). - Graphical abstract: Sr{sub 2}Cu(SeO{sub 3}){sub 2}Cl{sub 2} and SrCu{sub 2}(SeO{sub 3}){sub 2}Cl{sub 2} were obtained and characterized by X-ray diffraction technique, DTA and IR spectroscopy.

36 MATERIALS SCIENCE↗

Sr{sub 4}Ru{sub 6}ClO{sub 18}, a new Ru{sup 4+/5+} oxy-chloride, solved by precession electron diffraction: Electric and magnetic behavior

The crystal structure of Sr{sub 4}Ru{sub 6}ClO{sub 18}, a new Ru{sup 4+/5+} oxo-chloride, has been determined from Precession Electron Diffraction (PED) data acquired on a nanocrystal in a transmission electron microscope using the technique of electron diffraction tomography. This approach is described in details following a pedagogic route and a systematic comparison is made of this rather new method with other experimental methods of electron diffraction, and with the standard single crystal X-ray diffraction technique. Both transport and magnetic measurements, showed a transition at low temperature that may be correlated to Ru{sup 4+}/Ru{sup 5+} charge ordering. - Graphical abstract: Structure of Sr{sub 4}Ru{sub 6}ClO{sub 18}, determined using Precession Electron Diffraction data. - Highlights: • Structure of Sr{sub 4}Ru{sub 6}ClO{sub 18} was solved ab initio using precession electron diffraction. • This was done both on a nanometric sample and on a micrometric one. • Different type of experimental methods of electron diffraction are compared. • Single crystal X-ray diffraction was used to confirm the results. • Transport properties were characterized and show “exotic” behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sn 0.24 WO 3 hexagonal tungsten bronze prepared via the metal chloride route

In this work, we report the synthesis of Sn 0.24 WO 3 single crystals via an alternative, less well-known, solid-state synthetic approach that involves the use of tin chloride as a starting material. The compound adopts an unusual variant of the hexagonal tungsten bronze structure in space group P6/mmm (a = 7.4264(7) Å and c = 3.7843(4) Å) with a previously unreported distribution of Sn cations, disordered over two distinct sites in the tunnels. Sn 0.24 WO 3 shows no signs of superconductivity down to 170 mK and exhibits weakly-metallic conducting behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectroscopic, thermal and mechanical behavior of allylthiourea cadmium chloride single crystals

Allylthiourea cadmium chloride, a promising non-linear optical material was grown from aqueous solution by slow evaporation technique. Single crystal X-ray diffraction studies reveal that the crystal is trigonal structure with R3C space group. The spectroscopic properties were investigated by recording the Fourier transform infrared and optical absorption spectra. The dielectric studies of the sample were carried out at varying temperatures in the frequency range from 50 Hz to 5 MHz. The thermal properties were studied using thermogravimetric analyses and photopyroelectric technique. It is evident from the thermal studies that the decomposition of the crystal begins around 200 deg. C. The microhardness test conducted on the grown crystal suggests that the crystal has a relatively high mechanical strength. The second harmonic generation efficiency of the crystal was studied and found to be nearly 1.5 times that of urea.

36 MATERIALS SCIENCE↗

Molten Lithium-Brass/Zinc Chloride System as High-Performance and Low-Cost Battery

Batteries with high safety, low cost, and reasonable energy density are essential for grid-scale energy storage and still remain elusive. In this paper, we report a solid electrolyte-based liquid lithium-brass/zinc chloride (SELL-brass/ZnCl 2 ) battery using garnet-type lithium-ion solid electrolyte, lithium anode, and brass/ZnCl 2 cathode. The chemistry of the cell reaction and the ability of being assembled in discharged state ensures a high safety. The use of low-cost ZnCl 2 cathode can realize a low cell material cost of $16 kWh –1 . The adoption of lithium anode guarantees a high theoretical energy density of 750 Wh kg –1 and 2,250 Wh L –1 . Moreover, by using brass powder as a Zn source in the cathode, the Zn particle growth issue is successfully solved, and a good cycling stability of the battery can be obtained. As full cell performance and scalability are also verified, our SELL-brass/ZnCl 2 battery shows a high potential for practical use in grid energy storage.

25 ENERGY STORAGE↗

Dielectric relaxation of neodymium chloride in water and in methanol

In this work, an open-ended coaxial probe was used to study the dielectric relaxation of neodymium chloride (NdCl 3 ) in water and in methanol at room temperature over the frequency range 0.2–40.0 GHz. An equivalent circuit model based on the antenna model was used to obtain the dielectric spectra with the effective removal of spurious effects. This extends the use of the open-ended coaxial probe technique for highly conductive substances. The structural and thermodynamic parameters obtained from the dielectric spectra of aqueous NdCl 3 solutions suggest that solvent-separated ion pairs and solvent-shared ion pairs dominate the low-frequency behavior at low concentrations. In methanol, solvent-shared ion pair relaxation modes were detected. No contact pair relaxation was observed in either solvent. Under all conditions, Nd 3+ was strongly solvated, as reflected by its high effective hydration number. The estimated association constant of NdCl 3 in water at infinite dilution was within the literature values and was lower than that observed in methanol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systematic evaluation of fast neutron sensing with Cesium Hafnium Chloride

Cesium Hafnium Chloride (CHC) is a promising new scintillator for dual mode sensing of both neutrons and gamma-rays. The high chlorine content allows for both 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reaction channels leading to reliable detection of fast neutrons. By utilizing pulse shape discrimination (PSD), these neutron interactions may be reliably separated from gamma-ray signals with a high figure-of-merit (FOM) after optimization of the PSD algorithm. Here, in this study, the PSD algorithm settings for CHC were systematically investigated using a bare 252 Cf and a lead shielded plutonium beryllium neutron source. It was found that the PSD algorithm settings affects both the FOM and the neutron detection efficiency, but a FOM as high as 4.5 for alpha particles was observed in one data processing scenario. Further, an intrinsic 5 parts per million alpha emitting contamination was observed in the sample, which we attribute to natural uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Corrosion of alloys in a chloride molten salt (NaCl-LiCl) for solar thermal technologies

Next-generation solar power conversion systems in concentrating solar power (CSP) applications require high-temperature advanced fluids in the range of 600–800 °C. Current commercial CSP plants use molten nitrate salt mixtures as the heat transfer fluid and the thermal energy storage (TES) media while operating with multiple hours of energy capacity and at temperatures lower than 565 °C. At higher temperatures, the nitrates cannot be used because they decompose. Molten chloride salts are candidates for CSP applications because of their high decomposition temperatures and good thermal properties; but they can be corrosive to common alloys used in vessels, heat exchangers, and piping at these elevated temperatures. In this article, we present the results of the corrosion evaluations of several alloys in eutectic 34.42 wt% NaCl – 65.58 wt% LiCl at 650–700 °C in nitrogen atmosphere. Electrochemical evaluations were performed using open-circuit potential followed by a potentiodynamic polarization sweep. Corrosion rates were determined using Tafel slopes and Faraday's law. A temperature increase of as little as 50 °C more than doubled the corrosion rate of AISI stainless steel 310 and Incoloy 800H compared to the initial 650 °C test. These alloys exhibited localized corrosion. Inconel 625 was the most corrosion-resistant alloy with a corrosion rate of 2.80±0.38 mm/year. For TES applications, corrosion rates with magnitudes of a few millimeters per year are not acceptable because of economic considerations. Additionally, localized corrosion (intergranular or pitting) can be catastrophic. Furthermore, corrosion-mitigation approaches are required for advanced CSP plants to be commercially viable.

47 OTHER INSTRUMENTATION↗

Technical and economic feasibility of molten chloride salt thermal energy storage systems

A techno-economic study is performed to assess the feasibility of molten chloride salt thermal energy storage (TES) systems for next generation concentrating solar power. Refractory liners internally insulate tanks to allow tank shells to be constructed from carbon steel. The liner must not be wetted by salt to maintain predictable thermal properties and manageable heat loss out of the tank. The commercial scale tank liner is an anchored brick and mortar design with expansion joints to accommodate thermal expansion. Furthermore, finite element analysis is performed to optimize the thermal and mechanical profile of the tank. Equalizing the shell temperature between the water-cooled foundation and the shell wall is necessary to minimize differential thermomechanical stress and lower overall stress values below industrial allowable limits. The cost of the TES system is estimated to be $60/kWhth, which is four times greater than Department of Energy targets. Solutions to reduce system cost and overall risk are proposed.

14 SOLAR ENERGY↗

Assessment of dissimilar metal corrosion in molten chloride salt

Dissimilar metal corrosion between high nickel alloys and stainless steel was tested in purified molten chloride salt. Preliminary results have shown that corrosion rates are significantly affected for samples both when electrically connected and isolated. Suggesting that galvanic corrosion as well as non-galvanic dissimilar metal corrosion play a role in corrosion processes for multi component systems. Finally, these results suggest that even if efforts to prevent electrical contact are taken, close proximity of structural materials can still change corrosion rates in molten salt environments.

14 SOLAR ENERGY↗