Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHARTS - ENGINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Exploring Dynamic P-Q Capability and Abnormal Operations of Inverter-Based Resources

Nowadays, inverter-based resources are rapidly growing in electric power systems. On the other side, abnormal inverter operations are also occurring more often. Traditionally, inverter PQ capability charts are employed by electric utility companies to ensure safe and reliable operations of inverter-based resources. However, it is found in this paper that existing inverter PQ capability charts do not address the operating characteristics of an inverter correctly, which can result in irregular and unstable inverter operations. Here in this paper, a novel study is conducted to investigate inverter PQ capability charts, where constraints that are specific to an inverter are considered. It is found in this paper that the inverter PQ capability charts exhibit a unique dynamic nature under uncertain grid conditions. This dynamic nature has not been considered by the industry in managing, designing, and controlling an inverter as well as in developing international standards for inverter-based resources. Via both electromagnetic transient simulation and hardware experimental investigations, it is found that the dynamic PQ capability nature, together with the limitations of the existing control methods, are the underlying causes of many unusual inverter operations that have been reported in the literature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Entanglement negativity in the multiverse

We explore quantum entanglement between two causally disconnected regions in the multiverse. We first consider a free massive scalar field, and compute the entanglement negativity between two causally separated open charts in de Sitter space. The qualitative feature of it turns out to be in agreement with that of the entanglement entropy. We then introduce two observers who determine the entanglement between two causally disconnected de Sitter spaces. When one of the observers remains constrained to a region of the open chart in a de Sitter space, we find that the scale dependence enters into the entanglement. We show that a state which is initially maximally entangled becomes more entangled or less entangled on large scales depending on the mass of the scalar field and recovers the initial entanglement in the small scale limit. We argue that quantum entanglement may provide some evidence for the existence of the multiverse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC)

The aim of this study is to introduce tools to improve the security of each IMRT patient treatment by determining action levels for the dose delivery process. To achieve this, the patient-specific quality control results performed with an ionization chamber--and which characterize the dose delivery process--have been retrospectively analyzed using a method borrowed from industry: Statistical process control (SPC). The latter consisted in fulfilling four principal well-structured steps. The authors first quantified the short term variability of ionization chamber measurements regarding the clinical tolerances used in the cancer center ({+-}4% of deviation between the calculated and measured doses) by calculating a control process capability (C{sub pc}) index. The C{sub pc} index was found superior to 4, which implies that the observed variability of the dose delivery process is not biased by the short term variability of the measurement. Then, the authors demonstrated using a normality test that the quality control results could be approximated by a normal distribution with two parameters (mean and standard deviation). Finally, the authors used two complementary tools--control charts and performance indices--to thoroughly analyze the IMRT dose delivery process. Control charts aim at monitoring the process over time using statistical control limits to distinguish random (natural) variations from significant changes in the process, whereas performance indices aim at quantifying the ability of the process to produce data that are within the clinical tolerances, at a precise moment. The authors retrospectively showed that the analysis of three selected control charts (individual value, moving-range, and EWMA control charts) allowed efficient drift detection of the dose delivery process for prostate and head-and-neck treatments before the quality controls were outside the clinical tolerances. Therefore, when analyzed in real time, during quality controls, they should improve the security of treatments. They also showed that the dose delivery processes in the cancer center were in control for prostate and head-and-neck treatments. In parallel, long term process performance indices (P{sub p}, P{sub pk}, and P{sub pm}) have been analyzed. Their analysis helped defining which actions should be undertaken in order to improve the performance of the process. The prostate dose delivery process has been shown statistically capable (0.08% of the results is expected to be outside the clinical tolerances) contrary to the head-and-neck dose delivery process (5.76% of the results are expected to be outside the clinical tolerances).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-BRD-06: Creating a Safety Net for a Fully Automated, Script Driven Electronic Medical Record

Purpose: Demonstrate the effectiveness of in-house software in ensuring EMR workflow efficiency and safety. Methods: A web-based dashboard system (WBDS) was developed to monitor clinical workflow in real time using web technology (WAMP) through ODBC (Open Database Connectivity). Within Mosaiq (Elekta Inc), operational workflow is driven and indicated by Quality Check Lists (QCLs), which is triggered by automation software IQ Scripts (Elekta Inc); QCLs rely on user completion to propagate. The WBDS retrieves data directly from the Mosaig SQL database and tracks clinical events in real time. For example, the necessity of a physics initial chart check can be determined by screening all patients on treatment who have received their first fraction and who have not yet had their first chart check. Monitoring similar “real” events with our in-house software creates a safety net as its propagation does not rely on individual users input. Results: The WBDS monitors the following: patient care workflow (initial consult to end of treatment), daily treatment consistency (scheduling, technique, charges), physics chart checks (initial, EOT, weekly), new starts, missing treatments (>3 warning/>5 fractions, action required), and machine overrides. The WBDS can be launched from any web browser which allows the end user complete transparency and timely information. Since the creation of the dashboards, workflow interruptions due to accidental deletion or completion of QCLs were eliminated. Additionally, all physics chart checks were completed timely. Prompt notifications of treatment record inconsistency and machine overrides have decreased the amount of time between occurrence and execution of corrective action. Conclusion: Our clinical workflow relies primarily on QCLs and IQ Scripts; however, this functionality is not the panacea of safety and efficiency. The WBDS creates a more thorough system of checks to provide a safer and near error-less working environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-TeP4-08: Automating the Verification of Patient Treatment Parameters

Purpose: To automate the daily verification of each patient’s treatment by utilizing the trajectory log files (TLs) written by the Varian TrueBeam linear accelerator while reducing the number of false positives including jaw and gantry positioning errors, that are displayed in the Treatment History tab of Varian’s Chart QA module. Methods: Small deviations in treatment parameters are difficult to detect in weekly chart checks, but may be significant in reducing delivery errors, and would be critical if detected daily. Software was developed in house to read TLs. Multiple functions were implemented within the software that allow it to operate via a GUI to analyze TLs, or as a script to run on a regular basis. In order to determine tolerance levels for the scripted analysis, 15,241 TLs from seven TrueBeams were analyzed. The maximum error of each axis for each TL was written to a CSV file and statistically analyzed to determine the tolerance for each axis accessible in the TLs to flag for manual review. The software/scripts developed were tested by varying the tolerance values to ensure veracity. After tolerances were determined, multiple weeks of manual chart checks were performed simultaneously with the automated analysis to ensure validity. Results: The tolerance values for the major axis were determined to be, 0.025 degrees for the collimator, 1.0 degree for the gantry, 0.002cm for the y-jaws, 0.01cm for the x-jaws, and 0.5MU for the MU. The automated verification of treatment parameters has been in clinical use for 4 months. During that time, no errors in machine delivery of the patient treatments were found. Conclusion: The process detailed here is a viable and effective alternative to manually checking treatment parameters during weekly chart checks.

60 APPLIED LIFE SCIENCES↗

Fox Trails

1. This software utilizes python pandas to pull data from P6 databases or XER files. The software transforms the datasets into multiple main tables by joining, filtering, iteratively flattening hierarchical structured data, and pivoting datasets to give simple flat output tables. The activity table includes all of the information related to an activity including activity codes, global, EPS, and project codes, UDFs, and WBS information as separate columns. This includes the code id, code value and sequence number for all levels in hierarchical codes. The resource table is similar to the activity table and includes all of the information related to resources on activities including UPFs and resource codes. The resource time phased table takes the resource information and time phases it for the budget, forecast, late, and actual dates/units/costs that closely matches P6's user interface's values as it implements the resource curve and calendars. The wbs table contains the WBS structure broken out by levels and includes UDFs, codes, and notebook topics. The final P6 data table is the relationships table which simply contains the relationships. 2. When a user updates the tool with data (via giving it P6 project names with database username/password information or XER files) the system creates the data in #1, then creates a networkx graph with the activity data imbedded in the node data and the relationships added as edges. Each edge also has it's float calculated (working time distance between the predecessor and successor) and attached to the edge. Activities are also tagged as a potential start of a path based on their constraints, constraint dates, remaining start date, and activity status. When a user enters an activity ID into the UI, it runs a shortest path calculation on the network graph between each node tagged as potential start to the entered activity id based on the float tagged on the edge. Each path returned by the algorithm contains all of the nodes on the path in order, as well as the total float of the edges that make the path. This data is then collected and returned to the user in the form of a gantt chart with groupings for each path that includes the total float for each group. 3. Similar to 2, if the user passes through a reference dataset each activity set in the path is checked to see if it had a path in the reference dataset, if that path was the primary path between the start and end activities, and what has changed regarding logic and durations. These changes are color coded and summarized before sent to the user to be displayed by the UI for simple discovery. 4. Utilizing the data from #1, the user can submit desired grouping code(s) and filters to the system. The system will then pull the activities, resources, and relationships and create a gantt chart based on the groupings sent and filtered based on the filters sent. 5. The system will produce a gantt chart in a similar method to #4, but allows interactivity with the data. As the user interacts with the gantt chart, the software captures the changes and stores it with the user making the change so that project controls and implement those changes in P6.

Fox, Ben↗

Preliminary description of a new creep-fatigue design method that reduces over conservatism and simplifies the high temperature design process

The report provides the initial description of a new creep-fatigue design method for structural components in high temperature nuclear service. The new method is based on an integrated elastic-perfectly plastic (EPP) analysis and Simplified Model Test (SMT) approach that reduces over conservatism, improves the treatment of elastic follow up, and simplifies the design procedure, when compared with the current creep-fatigue design methods in ASME Boiler and Pressure Vessel Code. Developing the design charts for the EPP-SMT design method requires extrapolating SMT test data as a function of hold time and follow up factor. The report develops the preliminary design charts for Alloy 617 at temperatures between 800°C and 950°C by combining two extrapolation approaches developed in a previous work. The report also presents a comparative analysis between the EPP-SMT design method and the current ASME creep-fatigue design methods by evaluating design life of two sample geometries under different loading conditions. Results from the comparative analysis verify the EPP-SMT design charts but suggest the requirement of additional test data in the low strain range regime for improving the extrapolation procedure that will further reduce the over conservatism in the creep-fatigue damage evaluation. The report also concludes that the EPP-SMT design procedure can account for effect of primary load on creep-fatigue life by using a fixed, bounding value of follow up in constructing the design charts. The conclusions to this report describe the future work required to complete this new design method so it can be codified through a nuclear Code Case.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluate the application of ERTS-A data for detecting and mapping snow cover

The author has identified the following significant results. It is concluded from data analysis that the amount of information in ERTS-1 imagery with practical application to snow mapping is substantial. For the Arizona and California test sites, it appears that the extent of the mountain snowpacks can be mapped from ERTS-1 data in more detail than is depicted in aerial survey snow charts. In the Salt-Verde watershed, the agreement between the percentage of the area snow covered as measured from the ERTS-1 data and from aerial survey charts is generally well within 10%. In nearly all of the areas in which greater discrepancies occur, the differences can be explained by changes in snow cover during the interval between the two observations. In the southern Sierra Nevada, the agreement between ERTS-1 data and aerial survey charts is of the order of 5% in all cases, except for the Kaweah Basin on one date. In addition to comparative analysis with aerial snow charts, the ERTS-1 data have also been compared with high altitude aircraft photography. The ERAP data have provided an excellent source of correlative information. The results of the comparative analysis indicate that although small details in the snow line that cannot be detected in the ERTS-1 data can be mapped from higher resolution aircraft data, the boundaries of snow cover can be mapped just as accurately from ERTS-1 data.

Barnes, J. C.↗

Spacesuit guidebook

This guidebook is designed to supplement the Spacesuit wall chart (WAL-114) published by the Education Affairs Division, January 1990. The wall chart depicts Astronaut Bruce McCandless on his historic first untethered spacewalk using the manned maneuvering unit. He flew on Shuttle mission 41-B, and ventured 100 meters for the Shuttle's cargo bay and returned safely. This guidebook explains in depth the elements depicted on the wall chart in see-through and cut-away perspectives. Together the wall chart and guidebook show as well as explain the inside workings of the spacesuit and its various components. Forty separate elements are identified with an accompanying numerical legend. Those elements are further explained in this guidebook along with their functions and how they work in relation to other elements. Additional chapters discuss essential components of the spacesuit such as the primary life support system and the manned maneuvering unit, and the method for donning the spacesuit.

Source record↗

CRN5EXP: Expert system for statistical quality control

The purpose of the Expert System CRN5EXP is to assist in checking the quality of the coils at two very important mills: Hot Rolling and Cold Rolling in a steel plant. The system interprets the statistical quality control charts, diagnoses and predicts the quality of the steel. Measurements of process control variables are recorded in a database and sample statistics such as the mean and the range are computed and plotted on a control chart. The chart is analyzed through patterns using the C Language Integrated Production System (CLIPS) and a forward chaining technique to reach a conclusion about the causes of defects and to take management measures for the improvement of the quality control techniques. The Expert System combines the certainty factors associated with the process control variables to predict the quality of the steel. The paper presents the approach to extract data from the database, the reason to combine certainty factors, the architecture and the use of the Expert System. However, the interpretation of control charts patterns requires the human expert's knowledge and lends to Expert Systems rules.

Hentea, Mariana↗

Tables for the Rapid Estimation of Downwash and Sidewash Behind Wings Performing Various Motions at Supersonic Speeds

Equations for the downwash and sidewash due to supersonic yawed and unswept horseshoe vortices have been utilized in formulating tables and charts to permit a rapid estimation of the flow velocities behind wings performing various steady motions. Tabulations are presented of the downwash and sidewash in the wing vertical plane of symmetry due to a unit-strength yawed horseshoe vortex located at 20 equally spaced spanwise positions along lifting lines of various sweeps. (The bound portion of the yawed vortex is coincident with the lifting line.) Charts are presented for the purpose of estimating the spanwise variations of the flow-field velocities and give longitudinal variations of the downwash and sidewash at a nuMber of vertical and spanwise locations due to a unit-strength unswept horseshoe vortex. Use of the tables and charts to calculate wing downwash or sidewash requires a knowledge of the wing spanwise distribution of circulation. Sample computations for the rolling sidewash and angle-of-attack downwash behind a typical swept wing are presented to demonstrate the use of the tables and charts.

Bobbitt, Percy J.↗

Simulator Evaluation of a New Cockpit Descent Procedure

An experiment was conducted to evaluate flight crew performance of the "Precision Descent," a new cockpit procedure designed to support the Descent Advisor (DA), one of the components in a new air traffic control advisory system called the "Center-TRACON Automation System" (CTAS). The DA predicts when aircraft will reach a specific waypoint on the arrival route, and presents controllers with clearance advisories designed to improve the sequencing of arriving aircraft. The effectiveness of the DA depends on the aircraft's descent trajectory: where it begins descent, what speed it maintains, how fast and at what altitude it crosses the bottom-of-descent waypoint. The Precision Descent allows controllers to assign these descent parameters to the flight crew. A Field Evaluation of the DA was conducted in Denver in 1995. Three separate clearances using standard ATC phraseology were used to support the cockpit descent procedure during this evaluation. The number and length of these clearances caused problems for both controllers and flight crews, causing readback errors, repeat requests and procedure misunderstandings. These observations led to a focus group meeting in which controller and pilot participants in the 1995 FE assisted in the redesign of the procedure. The Precision Descent eliminates one clearance used in the earlier study, and greatly reduces the length of the remaining clearances. This was accomplished by using non-standard clearance phraseology that relies on a published procedure chart for correct interpretation. Eight type-rated flight crews flew eight Precision Descents in a Boeing 747-400 simulator. No training was provided: crews received either a procedure chart or a procedure chart with a flight manual bulletin describing procedure techniques. Video and digital data were recorded for each descent. Preliminary results indicate that moving information from the verbal clearance to the chart was successful: the shorter clearances and the procedure's default crossing restriction were understood, and procedure compliance of 81% was observed across all descents on six independent compliance measures. Some readback errors and procedure misunderstandings were still observed, however; particularly when descent clearances deviated from the normative procedure.

Crane, Barry↗

A Brief Study of the Speed Reduction of Overtaking Airplanes by Means of Air Brakes, Special Report

As an aid to airplane designers interested in providing pursuit airplanes with decelerating devices intended to increase the firing time when overtaking another airplane, formulas are given relating the pertinent distances and speeds in horizontal flight to the drag increase required. Charts are given for a representative parasite-drag coefficient from which the drag increase, the time gained, and the closing distance may be found. The charts are made up for three values of the ratio of the final speed of the pursuing airplane to the speed of the pursued airplane and for several values of the ratio of the speed of the pursued airplane to the initial speed of the pursuing airplane. Charts are also given indicating the drag increases obtainable with double split flaps and with conventional propellers. The use of the charts is illustrated by an example in which it is indicated that either double split flaps or, under certain ideal conditions, reversible propellers should provide the speed reductions required.

Pearson, H. A.↗

NIGMS Fluorine Detection

Please note that these charts were not presented at the CCMPP July 2015 Workshop; however, we would like to include these charts in the Workshop Proceedings.These charts present an overview of the NGIMS fluorine evaluation conducted for the MAVEN mission. The charts show that fluorine may be generated by the following mechanisms:-Reaction with water-Elevated temperature-Radiation, atomic oxygen, ultraviolet, spacecraft charging, and vacuum-Space environmental synergy

spacecraft contamination↗

The Sun and Space Weather

Audio and video provided as separate files. • CHART 3 audio – “SrFeb022013_1954ut28.21_Ashcraft.mp3” • CHART 9 Sun video – “IA18167_304Whip_best.mpg” • CHART 15 sun animation – “Sun_Animation_Mar23A.mp4” • CHART 33 SDO plus SOHO C2 video – “X2_C2_combo.mov”

Sun↗

NIRP Core Software Suite v. 1.0

The NIRP Core Software Suite is a core set of code that supports multiple applications. It includes miscellaneous base code for data objects, mathematic equations, and user interface components; and the framework includes several fully-developed software applications that exist as stand-alone tools to compliment other applications. The stand-alone tools are described below. Analyst Manager: An application to manage contact information for people (analysts) that use the software products. This information is often included in generated reports and may be used to identify the owners of calculations. Radionuclide Viewer: An application for viewing the DCFPAK radiological data. Compliments the Mixture Manager tool. Mixture Manager: An application to create and manage radionuclides mixtures that are commonly used in other applications. High Explosive Manager: An application to manage explosives and their properties. Chart Viewer: An application to view charts of data (e.g. meteorology charts). Other applications may use this framework to create charts specific to their data needs.

Whitener, Dustin Heath↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Variation and Control of Process Behavior

The purpose of this work was to highlight the importance of controlling process variability for successful quality assurance (QA). We describe the method of statistical process control for characterizing and controlling a process. Traditionally, QA has been performed by comparing some important measurement (e.g., linear accelerator output) against a corresponding specification. Although useful in determining the fitness of a particular measurement, this approach does not provide information about the underlying process behavior over time. A modern view of QA is to consider the time-ordered behavior of a process. Every process displays characteristic behaviors that are independent of the specifications imposed on it. The goal of modern QA is, not only to ensure that a process is on-target, but that it is also operating with minimal variation. This is accomplished by way of a data-driven approach using process behavior charts. The development of process behavior charts, historically known as control charts, and process behavior (action) limits are described. The effect these concepts have on quality management is also discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗