Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAMERAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Overview of the distributed image processing infrastructure to produce the Legacy Survey of Space and Time

The Vera C. Rubin Observatory is preparing to execute the most ambitious astronomical survey ever attempted, the Legacy Survey of Space and Time (LSST). Currently the final phase of construction is under way in the Chilean Andes, with the Observatory’s ten-year science mission scheduled to begin in 2025. Rubin’s 8.4-meter telescope will nightly scan the southern hemisphere collecting imagery in the wavelength range 320–1050 nm covering the entire observable sky every 4 nights using a 3.2 gigapixel camera, the largest imaging device ever built for astronomy. Automated detection and classification of celestial objects will be performed by sophisticated algorithms on high-resolution images to progressively produce an astronomical catalog eventually composed of 20 billion galaxies and 17 billion stars and their associated physical properties. In this article we present an overview of the system currently being constructed to perform data distribution as well as the annual campaigns which reprocess the entire image dataset collected since the beginning of the survey. These processing campaigns will utilize computing and storage resources provided by three Rubin data facilities (one in the US and two in Europe). Each year a Data Release will be produced and disseminated to science collaborations for use in studies comprising four main science pillars: probing dark matter and dark energy, taking inventory of solar system objects, exploring the transient optical sky and mapping the Milky Way. Also presented is the method by which we leverage some of the common tools and best practices used for management of large-scale distributed data processing projects in the high energy physics and astronomy communities. We also demonstrate how these tools and practices are utilized within the Rubin project in order to overcome the specific challenges faced by the Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Computer Vision-Enabled Smart Traffic Monitoring for Sustainable Transportation Management

Transportation accounts for a significant portion of total global energy consumption. Excessive energy consumption usually occurs in urban traffic environments with congestion and travel delays. With the advancement of remote sensing and computer vision technologies, real-time traffic conditions can be monitored. Therefore, sustainable transportation management strategies can be developed to optimize the overall energy and environment performance and reduce congestion and emissions. This work presents a smart traffic monitoring system based on remote camera sensors. Real-time and historical traffic conditions at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) were monitored and analyzed to develop optimal transportation management strategies for sustainability. Computer vision algorithms were developed and applied to process the real-time camera data to obtain complete traffic information across the ORNL campus. Weeks of historical data were collected and processed to analyze the traffic and identify bottlenecks. The proposed traffic monitoring and management approach can be applied and extended to benefit other campuses or urban areas.

Shao, Yunli↗

Economical Laue x-ray diffraction using photographic film and orientation of single crystals

Many Laue x-ray diffraction systems using the Polaroid XR-7 Land Diffraction Cassette camera became inactive after production of the required high sensitivity Polaroid T-57 instant film ceased. This Tutorial reports on a low-cost solution using the readily available replacement film with push processing to increase the effective film speed. The use of this film in the polaroid camera is described along with film development and digitization. The orientation of single crystals with the obtained data and free software is explained. A simple method to prepare single crystals with surfaces perpendicular to a desired crystallographic orientation is described. The content of this Tutorial may prove beneficial for educational and research laboratories.

47 OTHER INSTRUMENTATION↗

In situ TEM study of crystallization and chemical changes in an oxidized uncapped Ge 2 Sb 2 Te 5 film

Ge 2 Sb 2 Te 5 (GST-225) has been the most used active material in nonvolatile phase-change memory devices. Understanding the kinetics and dynamics involved in crystallization is critical for the optimization of materials and devices. A GST-225 thin film of 20 nm thickness was prepared by sputtering directly onto a Protochip and left uncapped and exposed to atmosphere for approximately 1 year. Here, early stages of crystallization and growth of the film have been studied inside the TEM from room temperature to 140 °C. The morphological and structural transformations have been studied by a C s -corrected environmental TEM, and images have been recorded using a high-speed low electron dose camera (Gatan K3 IS). The amorphous to crystalline transformation has been observed at ~35 °C. From the large field, high-resolution images obtained using the Gatan K3 IS camera early crystallization can be detected and nucleation rates and growth velocities can be obtained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of asymmetric explosive density evolution in the deflagration-to-detonation transition for porous explosives

We report deflagration-to-detonation transition phenomena in cylindrical columns of porous explosives based on octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX). The HMX powder and LX-14 (95.5 wt. % HMX and 4.5 wt. % estane polyurethane) prills were observed with high-speed cameras and flash x rays under conditions that allow for precise scaling and registration of the recorded images. These experimental results test the conventional assumption of axisymmetric, effective one-dimensional burning. Polycarbonate confinement tubes allowed this direct imaging with steel spheres employed as radio-opaque fiducials. Spheres embedded in the explosive column revealed the displacement of the explosive prior to deflagration. X-ray and fast camera images show that a dense plug of compact explosive develops ahead of the deflagration front. The internal fiducials register both internal changes in the plug and changes in the position between successive x-ray images. Tantalum witness strips placed on the inner wall of the explosive channel revealed radial expansion of the tube bore at successive x-ray exposures, indicating the internal pressure of about 100 MPa just before detonation. Images indicate that the deflagration is not only asymmetric but also involves newly observed transient phenomena just before detonation. Furthermore, we typically see a brief but continuous increase in deflagration speed and the formation of a deflagration channel that bypasses the plug just prior to detonation. We hypothesize that these phenomena play an important role in the deflagration-to-detonation transition itself.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectrally resolved polarization angle across the motional Stark effect spectrum

A new diagnostic technique has been developed that couples a spectrometer and an image-intensified camera into the traditional motional Stark effect (MSE) system on DIII-D. The image-intensified camera syncs with the photo-elastic modulators to spectrally resolve the Stokes parameters across the Stark multiplet. Polarization dependent phase shift, likely from a plasma facing mirror, leads to the spectropolarimeter measuring a variation in the polarization angle across the MSE spectrum of ∼8°.

Victor, B. S. (ORCID:0000000212512922)↗

Measurements of dynamic surface changes by digital holography for in situ plasma erosion applications

There are currently few viable diagnostic techniques for in situ measurement of plasma facing component erosion. Digital holography is intended to fill this gap. Progress on the development of single and dual CO 2 laser digital holography diagnostics for in situ plasma facing component erosion is discussed. The dual laser mode’s synthetic wavelength allows the measurable range to be expanded by a factor of ~400 compared to single laser digital holography. This allows the diagnostic to measure surface height changes of up to 4.5 μm in single laser mode and up to 2 mm in dual laser mode. Results include ex situ measurements of plasma eroded targets and also dynamic measurements of nm and μm scale motion of a target mounted on a precision translation stage. Dynamic measurements have successfully been made with the system operating in both single and dual laser modes, from ~50 nm to ~4 μm in single laser mode and up to ~400 μm in dual laser mode (limited only by the stage speed and camera acquisition duration). These results demonstrate the feasibility of using digital holography to characterize plasma facing component erosion dynamically, i.e., during plasma exposure. Results of proof-of-principle in situ digital holographic measurements of targets exposed to an electrothermal arc plasma source are presented.

Smith, Cary↗

Multi-energy calibration of a PILATUS3 CdTe detector for hard x-ray measurements of magnetically confined fusion plasmas

A multi-energy hard x-ray pin-hole camera based on the PILATUS3 X 100K-M CdTe detector has been developed at the Princeton Plasma Physics Laboratory for installation on the Tungsten Environment in Steady State Tokamak. This camera will be employed to study thermal plasma features such as electron temperature as well as non-thermal effects such as fast electron tails produced by a lower hybrid radiofrequency current drive and the birth of runaway electrons. The innovative aspect of the system lies in the possibility of setting the threshold energy independently for each of the ~100k pixels of the detector. This feature allows for the measurement of the x-ray emission in multiple energy ranges with adequate space and time resolution (~1 cm, 2 ms) and coarse energy resolution. In this work, the energy dependence of each pixel was calibrated within the range 15 keV–100 keV using a tungsten x-ray tube and emission from a variety of fluorescence targets (from yttrium to uranium). The data corresponding to pairs of K α emission lines are fit to the characteristic responsivity (“S-curve”), which describes the detector sensitivity across the 64 possible energy threshold values for each pixel; this novel capability is explored by fine-tuning the voltage of a six-bit digital-analog converter after the charge-sensitive amplifier for each of the ~100k pixels. Here, this work presents the results of the calibration including a statistical analysis. It was found that the achievable energy resolution is mainly limited by the width of the S-curve to 3 keV–10 keV for threshold energies up to 50 keV, and to ≥20 keV for energies above 60 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A time-resolved, in-chamber x-ray pinhole imager for Z

We have commissioned a new time-resolved, x-ray imaging diagnostic for the Z facility. The primary intended application is for diagnosing the stagnation behavior of Magnetized Liner Inertial Fusion (MagLIF) and similar targets. We have a variety of imaging systems at Z, both time-integrated and time-resolved, that provide valuable x-ray imaging information, but no system at Z up to this time provides a combined high-resolution imaging with multi-frame time resolution; this new diagnostic, called TRICXI for Time Resolved In-Chamber X-ray Imager, is meant to provide time-resolved spatial imaging with high resolution. The multi-frame camera consists of a microchannel plate camera. A key component to achieving the design goals is to place the instrument inside the Z vacuum chamber within 2 m of the load, which necessitates a considerable amount of x-ray shielding as well as a specially designed, independent vacuum system. Here, a demonstration of the imaging capability for a series of MagLIF shots is presented. Predictions are given for resolution and relative image irradiance to guide experimenters in choosing the desired configuration for their experiments.

47 OTHER INSTRUMENTATION↗

Converting existing optical detectors into fast x-ray detectors

Here, the very short burn time and small size of burning plasmas created at advanced laser-fusion facilities will require high-spatial-resolution imaging diagnostics with fast time resolution. These instruments will need to function in an environment of extremely large neutron fluxes that will cause conventional diagnostics to fail because of radiation damage and induced background levels. One solution to this challenge is to perform an ultrafast conversion of the x-ray signals into the optical regime before the neutrons are able to reach the detector and then to relay image the signal out of the chamber and into a shielded bunker, protected from the effects of these neutrons. With this goal in mind, the OMEGA laser was used to demonstrate high-temporal-resolution x-ray imaging by using an x-ray snout to image an imploding backlighter capsule onto a semiconductor. The semiconductor was simultaneously probed with the existing velocity interferometry system for any surface reflector (VISAR) diagnostic, which uses an optical streak camera and provided a one-dimensional image of the phase in the semiconductor as a function of time. The phase induced in the semiconductor was linearly proportional to the x-ray emission from the backlighter capsule. This approach would then allow a sacrificial semiconductor to be attached at the end of an optical train with the VISAR and optical streak camera placed in a shielded bunker to operate in a high neutron environment and obtain time-dependent one-dimensional x-ray images or time-dependent x-ray spectra from a burning plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Measurement of laser absorption in underdense plasmas using near-field imaging of the incident and transmitted beams

Measurements of laser absorption in high-temperature, underdense plasmas produced at the Omega Laser Facility are made using two near-field imaging detectors that diagnose the spatial profile and energy of the port P9 beam before and after it transmits through the plasma. The incident beam is sampled using a partial reflection from a full-aperture, (30 cm-diam) uncoated wedge pickoff located before the target chamber vacuum window and final focus lens assembly. A concave mirror reduces the reflected beam size, allowing it to be recorded directly using a charged-coupled device (CCD) camera. The P9 transmitted beam diagnostic (P9TBD) characterizes the transmitted light by terminating the expanded beam on a semi-transparent diffuser and imaging the illuminated surface using a lens and CCD camera. The P9TBD samples a numerical aperture twice as large as the input beam, allowing the energy of transmitted beams with moderate levels of beam spray to be measured accurately. Calibration shots with no plasma provide a path to infer absorption without absolute photometric calibration of either detector. Lastly, the cross-calibration between the two detectors was measured to remain stable at ±200 ppm, enabling measurements of total beam absorption below 1% with ±0.07% error.

47 OTHER INSTRUMENTATION↗

3D tracking of particles in a dusty plasma by laser sheet tomography

The collective behavior of levitated particles in a weakly ionized plasma (dusty plasma) has raised significant scientific interest. This is due to the complex array of forces acting on the particles and their potential to act as in situ diagnostics of the plasma environment. Ideally, the three-dimensional (3D) motion of many particles should be tracked for long periods of time. Typically, stereoscopic imaging using multiple cameras combined with particle image velocimetry is used to obtain a velocity field of many particles, yet this method is limited by its sample volume and short time scales. Here, we demonstrate a different, high-speed tomographic imaging method capable of tracking individual particles. We use a scanning laser sheet coupled to a single high-speed camera. We are able to identify and track tens of individual particles over centimeter length scales for several minutes, corresponding to more than 10 000 frames.

Physics↗

Temporal evolution of the light emitted by a thin, laser-ionized plasma source

We present an experimental and simulation-based investigation of the temporal evolution of light emission from a thin, laser-ionized helium plasma source. We demonstrate an analytic model to calculate the approximate scaling of the time-integrated, on-axis light emission with the initial plasma density and temperature, supported by the experiment, which enhances the understanding of plasma light measurement for plasma wakefield accelerator (PWFA) plasma sources. Our model simulates the plasma density and temperature using a split-step Fourier code and a particle-in-cell code. A fluid simulation is then used to model the plasma and neutral density, and the electron temperature as a function of time and position. We then show the numerical results of the space-and-time-resolved light emission and that collisional excitation is the dominant source of light emission. We validate our model by measuring the light emitted by a laser-ionized plasma using a novel statistical method capable of resolving the nanosecond-scale temporal dynamics of the plasma light using a cost-effective camera with microsecond-scale timing jitter. This method is ideal for deployment in the high radiation environment of a particle accelerator that precludes the use of expensive nanosecond-gated cameras. Our results show that our models can effectively simulate the dynamics of a thin, laser-ionized plasma source. In addition, this work provides a detailed understanding of the plasma light measurement, which is one of the few diagnostic signals available for the direct measurement of PWFA plasma sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Increased accuracy and signal-to-noise ratio through recent improvements in infra-red video bolometer fabrication and calibration

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.

Magnetic Fusion Energy↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗

Trapping and detection of single rubidium atoms in an optical dipole trap using a long-focus objective lens

The trapping of single atoms in optical dipole traps is widely used in experiments on the implementation of quantum processors based on neutral atoms, and studying interatomic interactions. Typically, such experiments employ lenses with a large numerical aperture (NA > 0.5), highly sensitive EMCCD cameras, or photon counters. In this work, we demonstrate trapping and detection of single rubidium atoms using a long-focus objective lens with a numerical aperture NA = 0.172 and a FLir Tau CNV sCMOS camera. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collision Tracking in OpenMC: Methods and Applications in Neutron Noise, Neutron Imaging, Time-of-Flight, and Multiplicity Counting

We present the development and application of a collision tracking feature within the OpenMC Monte Carlo particle transport code, designed for diverse applications such as neutron spectroscopy, scatter camera system, neutron noise, and multiplicity counting simulations. This feature enables the tracking of individual particle collisions, with potential applications in nuclear nonproliferation, reactor physics, and nuclear security. Additionally, the feature holds potential for the calibration of neutron detectors, specifically in converting light output into energy deposited within the detectors. The implementation consists of a set of filters—such as reaction type, energy, cell, and material—that constrain the set of collisions that are tracked, extensions to the Python API to enable simple input specification, and support for writing either OpenMC’s native HDF5-based format or the Monte Carlo particle list format. This feature was added to the official OpenMC release in version 0.15.3. In this work, the feature will be applied to showcase scenarios such as time-of-flight simulations, scatter-camera imaging for neutron source localization, neutron-noise analysis to extract integral kinetic parameters such as the prompt decay constant α, and multiplicity counting to estimate the mass of special nuclear materials. Ultimately, this feature aims to expand the application scope of open-source Monte Carlo particle transport codes such as OpenMC.

Monte Carlo code↗