An experimental study on round-trip efficiency of a preheating control with a medium office building

The interactions between building energy efficiency and demand response (DR) with buildings may complicate their impacts on the electricity grid and buildings, yet those interactions are not well understood. This work fills this gap by presenting an experimental study that quantifies the effects of DR on building energy efficiency. Unlike existing studies, this work 1) investigates the uncertainty levels when assessing the effects of DR; 2) studies the impact of rooftop heat pumps with direct expansion refrigerant-to-air coils on the round-trip efficiency. Specifically, we considered a medium office building (~1860 m 2 ), which is served by rooftop units, located in eastern Washington State. We performed preheating control tests during typical heating days in the year 2022 and compared the building’s energy consumption during the testing days to that during normal operation days under similar weather conditions. To understand how well those normal operation days represent the baseline for the assessment, the relationship between the energy performance of this building and weather conditions was also studied. Experimental results reveal that the round-trip efficiency (i.e., the ratio of discharging energy output from the building to charging energy input into the building) was between 0.16 and 0.92. The results show that significant energy loss may occur during the preheating process. Finally, it also suggests a significant correlation between the energy efficiency of the studied building under the preheating control and the outdoor temperature; and a highly nonlinear relationship between the zone temperature changing rate and the weather condition.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters

A quarter of all housing units in the United States are found in multifamily buildings, but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single-family homes are often a poor fit for individual multifamily units because the water heaters are often located in small internal closets. This confined space can limit the airflow to the heat pump, and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters: Preprint

A quarter of all housing units in the country are found in multifamily buildings but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single family homes are often a poor fit for individual multifamily units since the water heaters are often located in small internal closets. This confined space can limit the air flow to the heat pump and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

3,4‐Dicyanothiophene—a Versatile Building Block for Efficient Nonfullerene Polymer Solar Cells

Abstract In this contribution, a versatile building block, 3,4‐dicyanothiophene (DCT), which possesses structural simplicity and synthetic accessibility for constructing high‐performance, low‐cost, wide‐bandgap conjugated polymers for use as donors in polymer solar cells (PSCs), is reported. A prototype polymer, PB3TCN‐C66, and its cyano‐free analogue polymer PB3T‐C66, are synthesized to evaluate the potential of using DCT in nonfullerene PSCs. A stronger aggregation property in solution, higher thermal transition temperatures with higher enthalpies, a larger dipole moment, higher relative dielectric constant, and more linear conformation are exhibited by PB3TCN‐C66. Solar cells employing IT‐4F as the electron acceptor offer power conversion efficiencies (PCEs) of 11.2% and 2.3% for PB3TCN‐C66 and PB3T‐C66, respectively. Morphological characterizations reveal that the PB3TCN‐C66:IT‐4F blend exhibits better π–π paracrystallinity, a contracted domain size, and higher phase purity, consistent with its higher molecular interaction parameter, derived from thermodynamic calculations. Moreover, PB3TCN‐C66 offers a higher open‐circuit voltage and reduced energy loss than most state‐of‐the‐art wide‐bandgap polymers, without the need of additional electron‐withdrawing substituents. Two additional polymers derived from DCT also demonstrate promising performance with a higher PCE of 13.4% being achieved. Thus, DCT represents a versatile and promising building block for constructing high‐performance, low‐cost, conjugated polymers for application in PSCs.

Zhang, Bo↗

Generating realistic building electrical load profiles through the Generative Adversarial Network (GAN)

Building electrical load profiles can improve understanding of building energy efficiency, demand flexibility, and building-grid interactions. Current approaches to generating load profiles are time-consuming and not capable of reflecting the dynamic and stochastic behaviors of real buildings; some approaches also trigger data privacy concerns. In this study, we proposed a novel approach for generating realistic electrical load profiles of buildings through the Generative Adversarial Network (GAN), a machine learning technique that is capable of revealing an unknown probability distribution purely from data. The proposed approach has three main steps: (1) normalizing the daily 24-hour load profiles, (2) clustering the daily load profiles with the k-means algorithm, and (3) using GAN to generate daily load profiles for each cluster. The approach was tested with an open-source database – the Building Data Genome Project. We validated the proposed method by comparing the mean, standard deviation, and distribution of key parameters of the generated load profiles with those of the real ones. The KL divergence of the generated and real load profiles are within 0.3 for majority of parameters and clusters. Additionally, results showed the load profiles generated by GAN can capture not only the general trend but also the random variations of the actual electrical loads in buildings. We report the proposed GAN approach can be used to generate building electrical load profiles, verify other load profile generation models, detect changes to load profiles, and more importantly, anonymize smart meter data for sharing, to support research and applications of grid-interactive efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

R&D and Implementation Outcomes from the U.S.-India Bilateral Center for Building Energy Research and Development Program

This paper explores the role of international partnerships to facilitate low-energy building design, construction, and operations. We present the strategic approach, joint research and development outcomes, and implementation activities of a unique U.S.-India program on buildings energy efficiency, the Center for Building Energy Research and Development. We discuss the collaboration successes in both countries despite their dissimilar building contexts, implementation challenges and opportunities. We highlight a range of R&D outcomes, such as novel tools and technologies developed and tested by the joint teams, with their technical energy savings potential, as well as results of capacity building and technology demonstrations. A deep-dive into key new scientific methods around building energy monitoring and benchmarking that could have a significant impact on high-performance of buildings in both countries is also provided. Finally, in addition to joint R&D successes, pathways to deployment, and lessons learned are discussed as key takeaways.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Variable Refrigerant Flow Performance: Humidity and Efficiency in Multifamily Buildings in New York, NY

Variable refrigerant flow (VRF) systems have become common in large multifamily buildings. The upfront cost is appealing to developers, as a single system can provide all heating and cooling. VRF systems also use no on-site fossil fuels which can help avoid greenhouse gas emissions. However, there have been very few data on how VRF systems actually perform in buildings. Researchers monitored three new, multifamily buildings with a focus on VRF system sizing, humidity control, and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy-Efficiency Best Practice Policies and Policy Packages

This report addresses the single largest source of greenhouse gas emissions and the greatest opportunity to reduce these emissions. The IPCC 4 th Assessment Report estimates that globally 35% to 40% of all energy-related CO2 emissions (relative to a growing baseline) result from energy use in buildings. Emissions reductions from a combination of energy efficiency and conservation (using less energy) in buildings have the potential to cut emissions as much as all other energy-using sectors combined. This is especially the case for China, India and other developing countries that are expected to account for 80% or more of growth in building energy use worldwide over the coming decades. In short, buildings constitute the largest opportunity to mitigate climate change and special attention needs to be devoted to developing countries.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Contributing to Net Zero Building: High Energy Efficient EIFS Wall Systems

The team led by Dow Corning collaborated to increase the thermal performance of exterior insulation and finishing systems (EIFS) to reach R-40 performance meeting the needs for high efficiency insulated walls. Additionally, the project helped remove barriers to using EIFS on retrofit commercial buildings desiring high insulated walls. The three wall systems developed within the scope of this project provide the thermal performance of R-24 to R-40 by incorporating vacuum insulation panels (VIPs) into an expanded polystyrene (EPS) encapsulated vacuum insulated sandwich element (VISE). The VISE was incorporated into an EIFS as pre-engineered insulation boards. The VISE is installed using typical EIFS details and network of trained installers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identification of Energy Efficiency Opportunities through Building Data Analysis and Achieving Energy Savings through Improved Controls

This chapter will highlight analysis techniques to identify energy efficiency opportunities to improve operations and controls. A free tool, Energy Charting and Metrics (ECAM), will be used to assist in the analysis of whole-building, sub-metered, and/or data from the building automation system (BAS). Appendix A describes the features of ECAM in more depth, and also provide instructions for downloading ECAM and all resources pertaining to using ECAM.

Katipamula, Srinivas↗

Innovations in Building Energy Modeling: Research and Development Opportunities for Emerging Technologies

Building energy modeling (BEM) is a multipurpose tool for building energy efficiency (EE). The U.S. Department of Energy Building Technologies Office (BTO) seeks to expand the use and effectiveness of BEM in the design and operation of commercial and residential buildings with the goal of achieving lasting reductions in total and peak energy use. This report identifies gaps and outlines recommended initiatives to achieve this goal, based on a combination of technical analysis and stakeholder input. In addition to BTO, this report can benefit BEM professionals (architects, mechanical engineers, energy consultants, building auditors, equipment manufacturers, and BEM software vendors) and BEM clients (building owners and operators, EE program administrators, EE service providers, policymakers, and policy and code jurisdictions such as states and cities). This report was developed in two phases. In the first, BTO worked with a team from Navigant Consulting (now Guidehouse) to characterize objectives, opportunities, and current activities; identify gaps and barriers; and define initiatives. To collect input, Navigant conducted telephone interviews and workshops with industry experts. The initial phase produced a draft report, which was released for public review in 2016 and yielded over 400 comments. Based on these comments, BTO compiled a second draft report that addressed many of those comments while acknowledging changes that had occurred both at BTO and in the industry. Unlike the first draft report, the second focused much more heavily on BTO’s own role, portfolio, and activities. BTO is a direct player in the BEM field - it funds the development of several significant software packages that are embedded in commercial products - and transparency about its goals and future plans is requisite. BTO recognizes that a great number of other public and private organizations contribute to the BEM enterprise. With the second draft report, BTO did not attempt to produce a blueprint for the industry as a whole, but rather a working document BTO can use to iteratively solicit stakeholder input and synthesize it into a program. BTO released the second draft report for public review in 2019. The second round of review generated 83 pages of feedback and comments - almost exactly the length of the draft report itself - a significant portion of which was collected and synthesized by IBPSA-USA Advocacy Committee. This final report incorporates this feedback. This report does not address the use of BEM in support of building-based grid services, a recent BTO initiative called Grid-interactive Efficient Buildings (GEB). In 2019, BTO published a report that specifically addresses the role of BEM - and other “integration” technologies - in GEB.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Force-Triggered, Biobased Sealants for Prefabricated Building Components: Toward Improved Efficiency and Performance

The prefabricated building construction industry has made extensive progress in expediting the manufacture of prefabricated components at off-site plants. However, the sealing of joints between these components, which is crucial to ensuring the weatherproofing of the assembly, still represents a labor-intensive, on-site effort that relies on the manual installation of tapes and caulks. Here, to reduce work at the jobsite and improve the airtightness and waterproofness of building envelopes, we developed a sealant that can be installed at the plant on prefab components and have the curing reaction triggered at the jobsite by using microencapsulation technology to separate the reactive agents. A series of force-triggered, high-strength, and fast-curing sealants derived from biobased feedstocks were developed, which consist of a biobased epoxy agent encapsulated in a polymer shell, embedded in a biobased amine curing agent. The shell of the microcapsules allows an effective separation of the reactive species in the one-part sealant, allowing shelf stability to an otherwise fast-curing system as well as improving the hydrophobicity of the whole system. When force activates and breaks the microcapsules, the highly reactive epoxy and amine mix and cure, exhibiting peel strength values of up to 143 ppi (pounds per inch). The hydrophobicity of the sealants allows them to retain up to 94% of the original peel strength after complete submersion in water for 24 h, showcasing the water resistivity of the sealant system. The open-air shelf stability of the sealant complex is demonstrated by the obtention of peel strength values of ∼16 ppi when triggering the curing reaction even after being exposed 8 months to open air and humidity. The successful on-demand triggering of curing reactions and the shelf stability provide efficacy of these force-triggered sealants for installation on prefabricated components, storage for months prior to delivery, and assembly at a jobsite. These force-triggered biobased sealants for prefabricated buildings can result in lower installation time and cost and better performance than tapes and caulks at the jobsite.

biobased↗

An indium-based microporous metal–organic framework with unique three-way rod-shaped secondary building units for efficient methane and hydrogen storage

A novel microporous indium-based MOF material with unique 3-way rod-shaped secondary building units (SBUs), UTSA-22, was reported and exhibited high methane (CH 4 ) and hydrogen (H 2 ) storage. At 298 K and 65 bar, the total CH 4 volumetric uptake of UTSA-22 is 174 cm 3 (STP) cm -3 . Moreover, UTSA-22 shows a high CH 4 working capacity of 146 cm 3 (STP) cm -3 in a pressure range of 5–65 bar at 298 K. Additionally, UTSA-22 shows a high H 2 gravimetric storage capacity (1.2 wt%) at 298 K and 100 bar.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An international survey of building energy codes and their implementation

Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy demand from buildings. Access to benefits of building energy codes depends on comprehensive coverage of buildings by type, age, size, and geographic location; an implementation framework that involves a certified agency to inspect construction at critical stages; and independently tested, rated, and labeled building energy materials. Training and supporting tools are another element of successful code implementation, and their role is growing in importance, given the increasing flexibility and complexity of building energy codes. Some countries have also introduced compliance evaluation and compliance checking protocols to improve implementation. This article provides examples of practices that countries have adopted to assist with implementation of building energy codes.

54 ENVIRONMENTAL SCIENCES↗

Platform for Remote Deployment and Training for Enhanced Building Operation Practices (Building Re-Tuning and On-going Commissioning)

While a building’s energy usage is driven largely by its design and use, building operator behavior has a strong influence on its energy consumption. This project developed and piloted a specific, data-driven coaching methodology to help operators understand how they can adjust operations and/or affect no/low-cost repairs or upgrades to their specific building HVAC systems to reduce energy consumption. Named BuildingCoach, the operational optimization method used is based on the Building Re-tuning approach developed by the Pacific Northwest National Laboratory. A building operations analytics market has matured over the past decade, though its potential to affect energy-saving changes has not been fully realized. Training operators to understand the methods for operational optimization with the explicit approach of using building-system performance data is hypothesized to create a more effective, longer lasting result in building energy efficiency, and this strategy is the fundamental premise of this project. With the support of an Industry Advisory Board, the project succeeded in developing materials and recruiting for and delivering three pilot cohorts. Deliverables included twenty-two self-paced training modules (accessed via a Learning Management System) and a web-based platform that includes access to real-time building system data and a repository for building system documentation. The project set out to have 100 participants from 50 buildings in three pilot cohorts. In the end, there were 28 participants from 17 buildings, i.e., a significant shortfall. The first two pilot cohorts had only two buildings in each, and this was partially due to difficulties in deploying the Building Operator Coaching Solution (“the BOCS”), which is technology that extracts the data from the controls network and presents it as prescribed for coaching. In the third cohort, the project team deployed the BOCS successfully to 13 buildings, the methodology was piloted as intended, and numerous opportunities for optimization were identified. The BuildingCoach business plan charts a path to an economically sustainable effort. However, even with a licensing model captured in the final version of the business plan, the scalability is still limited to keeping less than 1,000 buildings affected by 2033. Even so, there are unexplored paths to greater scalability that are being considered. CUNY BPL is working to perpetuate and grow the use of BuildingCoach. As of this writing, about twenty buildings have either been connected or will be connected with operators coached / to be coached in the NYC municipal portfolio, twelve buildings across four campuses in NY State will use BuildingCoach, a NY upstate county wishes for six or seven buildings to participate with the support of funding from NYSERDA, and others have also expressed interest. In the decades to come, there will be an increasing percentage of large and mid-sized buildings that incorporate automated system optimization (ASO), and the building operators’ role will shift to spend more time on maintenance and monitoring. Meanwhile, programs such as BuildingCoach will play a critical role in optimizing operations. And, regardless of the emergence of ASO, operators will still need to understand how their systems operate so that they can monitor them properly. Within that context, BuildingCoach is an important step towards operators’ understanding of efficient building system operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enforcing Building Energy Codes in China: Progress and Comparative Lessons

From 1995 to 2005, building energy use in China increased more rapidly than the world average. China has been adding 0.4 to 1.6 billion square meters of floor space annually , making it the world’s largest market for new construction. In fact, by 2020, China is expected to comprise half of all new construction. In response to this, China has begun to make important steps towards achieving building energy efficiency, including the implementation of building energy standards that requires new buildings to be 65% more efficient than buildings from the early 1980s. Making progress on reducing building energy use requires both a comprehensive code and a robust enforcement system. The latter – the enforcement system – is a particularly critical component for assuring that a building code has an effect. China has dramatically enhanced its enforcement system in the past two years, with more detailed requirements for ensuring enforcement and new penalties for non-compliance. We believe that the U.S. and other developed countries could benefit from learning about the multiple checks and the documentation required in China. Similarly, some of the more user-friendly enforcement approaches developed in the U.S. and elsewhere may be useful for China as it strives to improve enforcement in rural and smaller communities. In this article, we provide context to China’s building codes enforcement system by comparing it to the U.S. Among some of the enforcement mechanisms we look at are testing and rating procedures, compliance software, and training and public information.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2024 Buildings Technology Baseline: Dataset Documentation

The Buildings Technology Baseline is a curated and regularly updated dataset of current and projected performance, retail, and installed price data for all major building energy technologies needed to enable cost/benefit analyses. Building technology analyses require an up-to-date understanding of installation costs and cost-effectiveness of key building energy efficiency technologies. The dataset was assembled by Guidehouse during fiscal year 2024. Data was gathered from the 2024 National Residential Efficiency Measures Database (NREMDB), the 2023 Energy Information Administration Updated Buildings Sector Appliance and Equipment Costs and Efficiencies ("EIA Building Data Report"), DOE Lighting Market Model, the 2023 RSMeans database, and the 2020 Grid-Interactive Efficient Building Technology Cost, Performance, and Lifetime Characteristics ("GEB Data Report"), Lawrence Berkeley National Laboratory, various literature, as well as new data from online retailers, stakeholder interviews, and contractor databases in 2023 and 2024. The dataset has been reviewed by subject matter experts at NREL and DOE. The 2024 dataset release is intended to be a starting point for interested users to provide feedback. This database is not intended to provide specific cost estimates for a specific project. The cost estimates do not include any rebates or tax incentives that may be available for the measures. Rather, it is meant to help determine which measures may be more cost-effective. The National Renewable Energy Laboratory (NREL) makes every effort to ensure accuracy of the data; however, NREL does not assume any legal liability or responsibility for the accuracy or completeness of the information.