Search for short-baseline oscillations at the NOvA Near Detector

Anomalous results from past neutrino experiments have been interpreted as potential evidence for an additional sterile neutrino with a mass on order of 1 eV, but this evidence remains inconclusive. The NOvA Near Detector is a 300 ton almost fully-active fine- grained liquid scintillator detector, that was designed for electron-neutrino identification. The detector is placed along the Fermilab NuMI beam line 1 km from the target and 14.6 mrad off-axis. At this off-axis angle the detector is exposed to a narrow band beam peaked at 2 GeV. Therefore the NOvA Near Detector will see neutrinos with a L/E range that is sensitive to oscillations between active neutrinos and light sterile neutrinos. In this report we discuss NOvA sensitivity from the joint electron-neutrino disappearance and muon-neutrino disappearance analysis search for short-baseline sterile neutrino mixing.

43 PARTICLE ACCELERATORS↗

The NuMAX Long Baseline Neutrino Factory concept

A Neutrino Factory where neutrinos of all species are produced in equal quantities by muon decay is described as a facility at the intensity frontier for exquisite precision providing ideal conditions for ultimate neutrino studies and the ideal complement to Long Baseline Facilities like LBNF at Fermilab. It is foreseen to be built in stages with progressively increasing complexity and performance, taking advantage of existing or proposed facilities at an existing laboratory like Fermilab. A tentative layout based on a recirculating linac providing opportunities for considerable saving is discussed as well as its possible evolution toward a muon collider if and when requested by Physics. Tentative parameters of the various stages are presented as well as the necessary R&D to address the technological issues and demonstrate their feasibility.

43 PARTICLE ACCELERATORS↗

Construction of precision wire readout planes for the Short-Baseline Near Detector (SBND)

The Short-Baseline Near Detector time projection chamber is unique in the design of its charge readout planes. These anode plane assemblies (APAs) have been fabricated and assembled to meet strict accuracy and precision requirements: wire spacing of 3 mm ± 0.5 mm and wire tension of 7 N ± 1 N across 3,964 wires per APA, and flatness within 0.5 mm over the 4 m × 2.5 m extent of each APA . Here, we describe the design, manufacture and assembly of these key detector components, with a focus on the quality assurance at each stage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overhaul and installation of the ICARUS-T600 liquid argon TPC electronics for the FNAL Short Baseline Neutrino program

The ICARUS T600 liquid argon (LAr) time projection chamber (TPC) underwent a major overhaul at CERN in 2016–2017 to prepare for the operation at FNAL in the Short Baseline Neutrino (SBN) program. This included a major upgrade of the photo-multiplier system and of the TPC wire read-out electronics. The full TPC wire read-out electronics together with the new wire biasing and interconnection scheme are described. The design of a new signal feed-through flange is also a fundamental piece of this overhaul whose major feature is the integration of all electronics components onto the signal flange. Initial functionality tests of the full TPC electronics chain installed in the T600 detector at FNAL are also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correction of the baseline fluctuations in the GEM-based ALICE TPC

To operate the ALICE Time Projection Chamber in continuous mode during the Run 3 and Run 4 data-taking periods of the Large Hadron Collider, the multi-wire proportional chamber-based readout was replaced with gas-electron multipliers. As expected, the detector performance is affected by the so-called common-mode effect, which leads to significant baseline fluctuations. A detailed study of the pulse shape with the new readout has revealed that it is also affected by ion tails. Since reconstruction and data compression are performed fully online, these effects must be corrected at the hardware level in the FPGA-based common readout units. The characteristics of the common-mode effect and of the ion tail, as well as the algorithms developed for their online correction, are described in this paper. The common-mode dependencies are studied using machine-learning techniques. Toy Monte Carlo simulations are performed to illustrate the importance of online corrections and to investigate the performance of the developed algorithms.

47 OTHER INSTRUMENTATION↗

Muon tagging with flash ADC waveform baselines

Here, this manuscript describes an innovative method to tag muons using the baseline information of the Flash ADC (FADC) waveform of PMTs in the JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment. The experiment is designed to search for evidence of sterile neutrinos, and a reliable method for muon tagging is an essential component for background rejection because the detector is located above ground, on the 3rd floor of the J-PARC Material and Life Science Experimental Facility (MLF). Cosmogenic muons that stop within the detector volume and produce a Michel electron are a particularly important background that must be rejected for our sterile neutrino search. Utilizing this innovative method, more than 99.8 % of Michel electrons can be rejected even without using information from the detector’s veto region PMTs. This technique can be employed by any experiments which uses a similar detector configuration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overview and status of the Long Baseline Neutrino Facility cryogenics system

The Long Baseline Neutrino Facility (LBNF) serves to provide the infrastructure necessary to support the Deep Underground Neutrino Experiment (DUNE), a growing international experiment to study neutrino science and proton decay. Situated at the Sanford Underground Research Facility (SURF), in Lead, SD, USA, DUNE will employ detectors located within massive cryostats filled with a total of 68,400 tons of ultrapure liquid argon. LBNF provides the cryogenic infrastructure necessary to supply and maintain that argon throughout the life of DUNE, as it enables the study of neutrinos from a new and improved beamline from Fermilab, as well as the dynamics of supernovae responsible for producing the heavy elements necessary for life and the possibility of proton decay. This contribution presents the modes of operation, layout, and main features of the cryogenic systems at LBNF. Those systems expected performance, functional requirements, and overall design status is also featured.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

VERY LONG BASELINE INTERFEROMETRY MEASURED PROPER MOTION AND PARALLAX OF THE γ-RAY MILLISECOND PULSAR PSR J0218+4232

PSR J0218+4232 is a millisecond pulsar (MSP) with a flux density ∼0.9 mJy at 1.4 GHz. It is very bright in the high-energy X-ray and γ-ray domains. We conducted an astrometric program using the European VLBI Network (EVN) at 1.6 GHz to measure its proper motion and parallax. A model-independent distance would also help constrain its γ-ray luminosity. We achieved a detection of signal-to-noise ratio S/N >37 for the weak pulsar in all five epochs. Using an extragalactic radio source lying 20 arcmin away from the pulsar, we estimate the pulsar's proper motion to be μ{sub α}cos δ = 5.35 ± 0.05 mas yr{sup –1} and μ{sub δ} = –3.74 ± 0.12 mas yr{sup –1}, and a parallax of π = 0.16 ± 0.09 mas. The very long baseline interferometry (VLBI) proper motion has significantly improved upon the estimates from long-term pulsar timing observations. The VLBI parallax provides the first model-independent distance constraints: d=6.3{sub −2.3}{sup +8.0} kpc, with a corresponding 3σ lower-limit of d = 2.3 kpc. This is the first pulsar trigonometric parallax measurement based solely on EVN observations. Using the derived distance, we believe that PSR J0218+4232 is the most energetic γ-ray MSP known to date. The luminosity based on even our 3σ lower-limit distance is high enough to pose challenges to the conventional outer gap and slot gap models.

79 ASTRONOMY AND ASTROPHYSICS↗

EVIDENCE FROM THE VERY LONG BASELINE ARRAY THAT J1502SE/SW ARE DOUBLE HOTSPOTS, NOT A SUPERMASSIVE BINARY BLACK HOLE

SDSS J150243.09+111557.3 is a merging system at z = 0.39 that hosts two confirmed active galactic nuclei (AGNs), one unobscured and one dust-obscured, offset by several kiloparsecs. Deane et al. recently reported evidence from the European VLBI Network (EVN) that the dust-obscured AGN exhibits two flat-spectrum radio sources, J1502SE/SW, offset by 26 mas (140 pc), with each source being energized by its own supermassive black hole (BH). This intriguing interpretation of a close binary BH was reached after ruling out a double-hotspot scenario, wherein both hotspots are energized by a single, central BH, a configuration occurring in the well-studied compact symmetric objects. When observed with sufficient sensitivity and resolution, an object with double hotspots should have an edge-brightened structure. We report evidence from the Very Long Baseline Array (VLBA) for just such a structure in an image of the obscured AGN with higher sensitivity and resolution than the EVN images. We thus conclude that a double-hotspot scenario should be reconsidered as a viable interpretation for J1502SE/SW, and suggest further VLBA tests of that scenario. A double-hotspot scenario could have broad implications for feedback in obscured AGNs. We also report a VLBA detection of high-brightness-temperature emission from the unobscured AGN that is offset several kiloparsecs from J1502SE/SW.

79 ASTRONOMY AND ASTROPHYSICS↗

Physics potential of a long-baseline neutrino oscillation experiment using a J-PARC neutrino beam and Hyper-Kamiokande

Hyper-Kamiokande will be a next generation underground water Cherenkov detector with a total (fiducial) mass of 0.99 (0.56) million metric tons, approximately 20 (25) times larger than that of Super-Kamiokande. One of the main goals of Hyper-Kamiokande is the study of CP asymmetry in the lepton sector using accelerator neutrino and anti-neutrino beams. In this paper, the physics potential of a long baseline neutrino experiment using the Hyper-Kamiokande detector and a neutrino beam from the J-PARC proton synchrotron is presented. The analysis uses the framework and systematic uncertainties derived from the ongoing T2K experiment. With a total exposure of 7.5 MW × 107 sec integrated proton beam power (corresponding to 1.56×1022 protons on target with a 30 GeV proton beam) to a 2.5-degree off-axis neutrino beam, it is expected that the leptonic CP phase δCP can be determined to better than 19 degrees for all possible values of δCP, and CP violation can be established with a statistical significance of more than 3σ (5σ) for 76% (58%) of the δCP parameter space. Using both νe appearance and νμ disappearance data, the expected 1σ uncertainty of sin2θ23 is 0.015(0.006) for sin2θ23=0.5(0.45).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward a Robust Confirmation or Refutation of the Sterile-Neutrino Explanation of Short-Baseline Anomalies

The sterile neutrino interpretation of the LSND and MiniBooNE neutrino anomalies is currently being tested at three liquid argon detectors: MicroBooNE, SBND, and ICARUS. It has been argued that a degeneracy between 𝜈 𝜇 → 𝜈 𝑒 and 𝜈 𝑒 → 𝜈 𝑒 oscillations significantly degrades their sensitivity to sterile neutrinos. Through an independent study, we show two methods to eliminate this concern. First, we resolve this degeneracy by including external constraints on 𝜈𝑒 disappearance from the PROSPECT reactor experiment. Second, by properly analyzing the full three-dimensional parameter space, we demonstrate that the stronger-than-sensitivity exclusion from MicroBooNE alone already covers the entire 2⁢𝜎 preferred regions of MiniBooNE at the level of 2−3⁢𝜎. We show that upcoming searches at SBND and ICARUS can improve on this beyond the 4⁢𝜎 level, thereby providing a rigorous test of short-baseline anomalies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of new physics on the JUNO-long-baseline synergy in the neutrino mass ordering determination

The determination of the neutrino mass ordering is one of the flagship goals in particle physics. A well-known and powerful synergy emerges when combining high-precision measurements of the effective atmospheric mass-squared splitting from electron antineutrino disappearance in reactor experiments with that from muon (anti)neutrino disappearance in accelerator-based long-baseline experiments. To fully exploit this synergy, percent-level precision in the atmospheric mass splitting is required—a target that JUNO is expected to achieve within a few months of data taking. This motivated the formulation of a mass ordering sum rule for neutrino disappearance channels, which shows that by combining data from T2K and NOvA with JUNO after one year of operation, the neutrino mass ordering can be determined at the 3⁢𝜎 confidence level. Since JUNO has recently started taking data, it is timely to ask whether this sum rule remains robust in the presence of new physics. We identify the necessary conditions for new physics to affect the sum rule and demonstrate that, in some cases, such effects could lead to an incorrect inference of the mass ordering. As concrete examples, we consider scalar nonstandard interactions (SNSI) and neutrinos coupled to an ultralight scalar field. We find that, for SNSI, current constraints render any modification of the sum rule negligible, whereas in the latter case, the inference of the ordering requires caution. Nevertheless, these effects can be disentangled, illustrating how the sum rule can also be used to search for new physics.

Alves, Gustavo F. S. [Fermi National Accelerator L↗

Proton irradiated graphite grades for a long baseline neutrino facility experiment

In search of a low-Z pion production target for the Long Baseline Neutrino Facility (LBNF) of the Deep Underground Neutrino Experiment (DUNE) four graphite grades were irradiated with protons in the energy range of 140–180 MeV, to peak fluence of ~6.1×10 20 p/cm 2 and irradiation temperatures between 120–200 °C. The test array included POCO ZXF-5Q, Toyo-Tanso IG 430, Carbone-Lorraine 2020 and SGL R7650 grades of graphite. Irradiation was performed at the Brookhaven Linear Isotope Producer. Postirradiation analyses were performed with the objective of (a) comparing their response under the postulated irradiation conditions to guide a graphite grade selection for use as a pion target and (b) understanding changes in physical and mechanical properties as well as microstructure that occurred as a result of the achieved fluence and in particular at this low-temperature regime where pion graphite targets are expected to operate. A further goal of the postirradiation evaluation was to establish a proton-neutron correlation damage on graphite that will allow for the use of a wealth of available neutron-based damage data in proton-based studies and applications. Macroscopic postirradiation analyses as well as energy dispersive x-ray diffraction of 200 KeV x rays at the NSLS synchrotron of Brookhaven National Laboratory were employed. The macroscopic analyses revealed differences in the physical and strength properties of the four grades with behavior however under proton irradiation that qualitatively agrees with that reported for graphite under neutrons for the same low temperature regime and in particular the increase of thermal expansion, strength and Young’s modulus. The proton fluence level of ~10 20 cm -2 where strength reaches a maximum before it begins to decrease at higher fluences has been identified and it agrees with neutron-induced changes. X-ray diffraction analyses of the proton irradiated graphite revealed for the first time the similarity in microstructural graphite behavior to that under neutron irradiation and the agreement between the fluence threshold of ~5×10 20 cm -2 where the graphite lattice undergoes a dramatic change. The confirmed similarity in behavior and agreement in threshold fluences for proton and neutron irradiation effects on graphite reported for the first time in this study will enable the safe utilization of the wealth of neutron irradiation data on graphite that extends to much higher fluences and different temperature regimes by the proton accelerator community searching for multi-MW graphite targets.

43 PARTICLE ACCELERATORS↗

Baseline predictions of elliptic flow and fluctuations for the RHIC Beam Energy Scan using response coefficients

Currently the RHIC Beam Energy Scan is exploring a new region of the Quantum Chromodynamic phase diagram at large baryon densities that approaches nuclear astrophysics regimes. This provides an opportunity to study relativistic hydrodynamics in a regime where the net conserved charges of baryon number, strangeness, and electric charge play a role, which will significantly change the theoretical approach to simulating the baryon-dense Quark-Gluon Plasma. In this work, we detail many of the important changes needed to adapt both initial conditions and the medium to baryon-rich matter. Then, we make baseline predictions for the elliptical flow and fluctuations based on extrapolating the physics at LHC and top RHIC energies to support future analyses of where and how the new baryon-dense physics causes these extrapolations to break down. First we compare eccentricities across beam energies, exploring their underlying assumptions; we find the the extrapolated initial state is predicted to be nearly identical to that at AuAu $\sqrt{s_{NN}}$ = 200 GeV. Then the final flow harmonic predictions are based on linear+cubic response. We discuss preliminary STAR results in order to determine the implications that they have for linear+cubic response coefficients at the lowest beam energy of AuAu $\sqrt{s_{NN}}$ = 7 GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Smallness of matter effects in long-baseline muon neutrino disappearance

Current long-baseline accelerator experiments, NOvA and T2K, are making excellent measurements of neutrino oscillations and the next generation of experiments, DUNE and HK, will make measurements at the O ( 1 % ) level of precision. These measurements are a combination of the appearance channel which is more challenging experimentally but depends on many oscillation parameters, and the disappearance channel which is somewhat easier and allows for precision measurements of the atmospheric mass splitting and the atmospheric mixing angle. It is widely recognized that the matter effect plays a key role in the appearance probability, yet the effect on the disappearance probability is surprisingly small for these experiments. Here we investigate both exactly how small the effect is and show that it just begins to become relevant in the high statistics regime of DUNE. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast and accurate algorithm for calculating long-baseline neutrino oscillation probabilities with matter effects

Neutrino oscillation experiments will be entering the precision era in the next decade with the advent of high statistics experiments like DUNE, HK, and JUNO. Correctly estimating the confidence intervals from data for the oscillation parameters requires very large Monte Carlo datasets involving calculating the oscillation probabilities in matter many, many times. In this paper, we leverage past work to present a new, fast, precise technique for calculating neutrino oscillation probabilities in matter optimized for long-baseline neutrino oscillations in the Earth’s crust including both accelerator and reactor experiments. For ease of use by theorists and experimentalists, we provide fast ++ and codes . Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Decaying sterile neutrinos at short baselines

Long-standing anomalous experimental results from short-baseline neutrino experiments have persisted for decades. These results, when interpreted with one or more light sterile neutrinos, are inconsistent with numerous null results experimentally. However, if the sterile neutrino decays en route to the detector, this can mimic ν μ → ν e oscillation signals while avoiding many of these external constraints. We revisit this solution to the MiniBooNE and LSND puzzles in view of new data from the MicroBooNE experiment at Fermilab. Using MicroBooNE’s liquid-argon time-projection chamber search for an excess of ν e in the Booster beam, we derive new limits in two models’ parameter spaces of interest; where the sterile neutrino decays (I) via mixing with the active neutrinos, or (II) via higher-dimensional operators. We also provide an updated, comprehensive fit to the MiniBooNE neutrino- and antineutrino-beam data, including appearance ( ν e ) and disappearance ( ν μ ) channels. Despite alleviating the tension with muon neutrino disappearance experiments, we find that the latest MicroBooNE analysis rules out the decaying sterile neutrino solution in a large portion of the parameter space at more than 99% CL. Published by the American Physical Society 2024

Hostert, Matheus (ORCID:0000000295848877)↗

Search for very-short-baseline oscillations of reactor antineutrinos with the SoLid detector

In this paper we report the first scientific result based on antineutrinos emitted from the BR2 reactor at SCK CEN. The SoLid experiment uses a novel type of highly granular detector whose basic detection unit combines two scintillators, polyvinyl toluene (PVT) and Li 6 F : ZnS ( Ag ) , to measure antineutrinos via their inverse- β -decay products. An advantage of PVT is its highly linear response as a function of deposited particle energy. The full-scale detector comprises 12 800 voxels and operates over a very short 6.3–8.9 m baseline from the reactor core. The detector segmentation and its three-dimensional imaging capabilities facilitate the extraction of the positron energy from the rest of the visible energy, allowing the latter to be utilized for signal-background discrimination. We present a result obtained from 280 reactor-on days (55 MW mean power) and 172 reactor-off days, respectively, of live data taking. A total of 29 479 ± 603 (stat) antineutrino candidates have been selected, corresponding to an average rate of 105 events per day and a signal-to-background ratio of 0.27. A search for disappearance of antineutrinos to a sterile state has been conducted using complementary model-dependent frequentist and Bayesian fits, providing constraints on the allowed region of the reactor antineutrino anomaly.