Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Proton irradiation of stem cells: Radiation damage and chemical radioprotection

Effects of high energy protons on erythropoietic stem cells and radioprotection by chemicals were investigated in NASA Space Radiation Effects Laboratory. The effects of a parallel beam of 600 MeV protons. The fluence, when converted to dose, were referenced to the synchrocyclotron beam monitors which were then used to administer radiation exposures. Mice were given graded doses to 300 rads to determine dose-response curve. Other mice received saline, AET, or 5-hydroxytryptamine 10 to 15 minutes before exposure.

Riley, R. C.↗

Graphics-System Color-Code Interface

Circuit originally developed for a flight simulator interfaces a computer graphics system with color monitor. Subsystem is intended for particular display computer (AGT-130, ADAGE Graphics Terminal) and specific color monitor (beam penetration tube--Penetron). Store-and-transmit channel is one of five in graphics/color-monitor interface. Adding 5-bit color code to existing graphics programs requires minimal programing effort.

Tulppo, J. S.↗

Simple Schlieren Light Meter

Simple light-meter circuit used to position knife edge of schlieren optical system to block exactly half light. Enables operator to check quickly position of knife edge between tunnel runs to ascertain whether or not in alignment. Permanent measuring system made part of each schlieren system. If placed in unused area of image plane, or in monitoring beam from mirror knife edge, provides real-time assessment of alignment of schlieren system.

Rhodes, David B.↗

Optical Transition Radiation System for ATF2

In this paper we present the first measurements performed during the fall 2010 and early 2011 runs. Software development, simulations and hardware improvements to the Multi-Optical Transition Radiation System installed in the beam diagnostic section of the Extraction line of ATF2 are described. 2D emittance measurements have been performed and the system is being routinely used for coupling correction. Realistic beam simulations have been made and compared with the measurements. A demagnifier lens system to improve the beam finding procedure has been designed and will be implemented in a future run. We also discuss further work planned for the subsequent run periods.

43 PARTICLE ACCELERATORS↗

Diagnostics Challenges for FACET-II

FACET-II is a prospective user facility at SLAC National Accelerator Laboratory. The facility will focus on high-energy, high-brightness beams and their interaction with plasma and lasers. The accelerator is designed for high-energy-density electron beams with peak currents of approximately 50 kA (potentially 100 kA) that are focused down to below 10x10 micron transverse spot size at an energy of 10 GeV. Subsequent phases of the facility will provide positron beams above 10 kA peak current to the experiment station. Experiments will require well characterised beams; however, the high peak current of the electron beam can lead to material failure in wirescanners, optical transition radiation screens and other instruments critical for measurement or delivery. The radiation environment and space constraints also put additional pressure on diagnostic design.

43 PARTICLE ACCELERATORS↗

LBNF 1.2 MW TARGET: CONCEPTUAL DESIGN & FABRICATION

Fermilab’s Long-Baseline Neutrino Facility (LBNF) will utilize a modified design based on the NuMI low energy target that is reconfigured to accommodate beam operation at 1.2 MW. Achieving this power with a graphite target material and ancillary systems originally rated for 400 kW requires several design changes and R&D efforts related to material bonding and electrical isolation. Target cooling, structural design, and fabrication techniques must address higher stresses and heat loads that will be present during 1.2 MW operation, as the assembly will be subject to cyclic loads and thermal expansion. Mitigations must be balanced against compromises in neutrino yield. Beam monitoring and subsystem instrumentation will be updated and added to ensure confidence in target positioning and monitoring. Remote connection to the target hall support structure must provide for the eventual upgrade to a 2.4 MW target design, without producing excessive radioactive waste or unreasonable exposure to technicians during reconfiguration. Current designs and assembly layouts will be presented, in addition to current findings on processes and possibilities for prototype and final assembly fabrication.

43 PARTICLE ACCELERATORS↗

LBNF 1.2 MW Target: Conceptual Design & Fabrication

Fermilab’s Long-Baseline Neutrino Facility (LBNF) will utilize a modified design based on the NuMI low energy target that is reconfigured to accommodate beam operation at 1.2 MW. Achieving this power with a graphite target material and ancillary systems originally rated for 400 kW requires several design changes and R&D efforts related to material bonding and electrical isolation. Target cooling, structural design, and fabrication techniques must address higher stresses and heat loads that will be present during 1.2 MW operation, as the assembly will be subject to cyclic loads and thermal expansion. Mitigations must be balanced against compromises in neutrino yield. Beam monitoring and subsystem instrumentation will be updated and added to ensure confidence in target positioning and monitoring. Remote connection to the target hall support structure must provide for the eventual upgrade to a 2.4 MW target design, without producing excessive radioactive waste or unreasonable exposure to technicians during reconfiguration. Current designs and assembly layouts will be presented, in addition to current findings on processes and possibilities for prototype and final assembly fabrication.

43 PARTICLE ACCELERATORS↗

BPM Design and Impedance Considerations for a Rotatable Collimator for the LHC Collimation Upgrade

The Phase II upgrade to the LHC collimation system calls for complementing the 30 high robust Phase I graphite secondary collimators with 30 high Z Phase II collimators. This paper reports on BPM and impedance considerations and measurements of the integrated BPMs in the prototype rotatable collimator to be installed in the Super Proton Synchrotron (SPS) at CERN. The BPMs are necessary to align the jaws with the beam. Without careful design the beam impedance can result in unacceptable heating of the chamber wall or beam instabilities. The impedance measurements involve utilizing both a single displaced wire and two wires excited in opposite phase to disentangle the driving and detuning transverse impedances. Trapped mode resonances and longitudinal impedance are to also be measured and compared with simulations. These measurements, when completed, will demonstrate the device is fully operational and has the impedance characteristics and BPM performance acceptable for installation in the SPS.

43 PARTICLE ACCELERATORS↗

11.424 Ghz Stripline Transversal Filter for Sub-Picosecond Bunch Timing Measurements

Measurement of time-of-arrival or instantaneous longitudinal position is a fundamental beam diagnostic. We present results from a stripline transversal periodic coupler structure which forms the heart of a sub-ps beam timing detector. This filter structure approximates a sinx/x response in the frequency domain which corresponds to a limited pulse length response in the time domain. These techniques have been used extensively in beam feedback systems at 3 GHz center frequencies with operational single-shot resolutions of 200 fs [1]. We present a new design, based on a 11.424 GHz center frequency, which is intended to offer a factor of four improvement in time resolution. Two-dimensional electromagnetic simulation results are shown, and the design optimization approach leading to the final circuit implementation is illustrated. The prototype circuit has been fabricated on 64mil Rogers 4003 and lab frequency domain and time domain data are compared to the 2-D simulation results. Performance of the prototype circuit is shown with applicability to sub-ps beam measurements in LINAC and FEL applications.

43 PARTICLE ACCELERATORS↗

Real-time thermomechanical property monitoring during ion beam irradiation using in situ transient grating spectroscopy

A facility for continuously monitoring the thermal and elastic performance of materials under exposure to ion beam irradiation has been designed and commissioned. By coupling an all-optical, non-contact, non-destructive measurement technique known as transient grating spectroscopy (TGS) to a 6 MV tandem ion accelerator, bulk material properties may be measured at high fidelity as a function of irradiation exposure and temperature. Ion beam energies and optical parameters may be tuned to ensure that only the properties of the ion-implanted surface layer are interrogated. This facility provides complementary capabilities to the set of facilities worldwide which have the ability to study the evolution of microstructure in situ during radiation exposure, but lack the ability to measure bulk-like properties. Here, the measurement physics of TGS, design of the experimental facility, and initial results using both light and heavy ion exposures are described. Lastly, several short- and long-term upgrades are discussed which will further increase the capabilities of this diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Latent diffusion can map beam loss to two-dimensional phase-space projections

Beam loss monitors (BLMs) and beam current monitors (BCMs) are ubiquitous at particle accelerators around the world. These simple devices provide noninvasive high-level beam measurements but give no insight into the detailed 6D (𝑥,𝑦,𝑧,𝑝 𝑥 ,𝑝 𝑦 ,𝑝 𝑧 ) beam phase-space distributions or dynamics. We show that generative conditional latent diffusion models can learn intricate patterns to solve the extreme inverse problem of mapping waveforms of tens of BLMs or BCMs along an accelerator to detailed 2D projections of a charged particle beam’s 6D phase-space density. This transformational method can be used at any particle accelerator to transform simple noninvasive devices into detailed beam phase-space diagnostics. We demonstrate this concept via multiparticle simulations of the high-intensity beam in the kilometer-long Los Alamos Neutron Science Center linear proton accelerator.

43 PARTICLE ACCELERATORS↗

Evaluation of an Alternative Method for Beam Window Temperature Monitoring

A molybdenum-99 production system utilizing a Linac electron source beam and the γ/n reaction on Mo-100 metal targets will employ cooling with high-pressure helium (He) gas. The electron beam will go through a window that separates the high-pressure He gas and the vacuum of the accelerator beam line.

43 PARTICLE ACCELERATORS↗

Development of a Negative Hydrogen Ion Source for Spatial Beam Profile Measurement of a High Intensity Positive Ion Beam

We have been developing a negative hydrogen ion (H{sup -} ion) source for a spatial beam profile monitor of a high intensity positive ion beam as a new diagnostic tool. In case of a high intensity continuous-wave (CW) deuteron (D{sup +}) beam for the International Fusion Materials Irradiation Facility (IFMIF), it is difficult to measure the beam qualities in the severe high radiation environment during about one-year cyclic operation period. Conventional techniques are next to unusable for diagnostics in the operation period of about eleven months and for maintenance in the one-month shutdown period. Therefore, we have proposed an active beam probe system by using a negative ion beam and started an experimental study for the proof-of-principle (PoP) of the new spatial beam profile monitoring tool. In this paper, we present the status of development of the H{sup -} ion source as a probe beam source for the PoP experiment.

43 PARTICLE ACCELERATORS↗

Fluctuation of an ion beam extracted from an AC filament driven Bernas-type ion source

Argon ion beam fluctuation from an AC filament driven Bernas-type ion source is observed. The ion beam was measured by an 8 measurement elements beam profile monitor. The amplitude of the beam current fluctuation stayed in the same level from 100 Hz to 1 kHz of the filament heating frequency. The beam current fluctuation frequency measured by the beam profile monitor was equal to the frequency of the AC filament operation. The fluctuation amplitudes of the beam current by AC operation were less than 7% and were in the same level of the DC operation.

43 PARTICLE ACCELERATORS↗

Thermographic Microstructure Monitoring in Electron Beam Additive Manufacturing

To reduce the uncertainty of build performance in metal additive manufacturing, robust process monitoring systems that can detect imperfections and improve repeatability are desired. One of the most promising methods for in-situ monitoring is thermographic imaging. However, there is a challenge in using this technology due to the difference in surface emittance between the metal powder and solidified part being observed that affects the accuracy of the temperature data collected. This developed a method for properly calibrating temperature profiles from thermographic data and then determining important characteristics of the build through additional processing. The thermographic data was analyzed to determine the transition of material from metal powder to a solid as-printed part. A corrected temperature profile was then assembled for each point using calibrations for these surface conditions. Using this data, we calculated the thermal gradient and solid-liquid interface velocity and correlated it to microstructural variation within the part experimentally. This work shows that by using a method of process monitoring, repeatability of a build could be monitored specifically in relation to microstructure control.

36 MATERIALS SCIENCE↗

Characteristics of flattening filter free beams at low monitor unit settings

Purpose: Newer linear accelerators (linacs) have been equipped to deliver flattening filter free (FFF) beams. When FFF beams are used for step-and-shoot intensity-modulated radiotherapy (IMRT), the stability of delivery of small numbers of monitor units (MU) is important. The authors developed automatic measurement techniques to evaluate the stability of the dose profile, dose linearity, and consistency. Here, the authors report the performance of the Artiste™ accelerator (Siemens, Erlangen, Germany) in delivering low-MU FFF beams.Methods: A 6 MV flattened beam (6X) with 300 MU/min dose rate and FFF beams of 7 (7XU) and 11 MV (11XU), each with a 500 MU/min dose rate, were measured at 1, 2, 3, 5, 8, 10, and 20 MU settings. For the 2000 MU/min dose rate, the 7 (7XUH) and 11 MV (11XUH) beams were set at 10, 15, 20, 25, and 30 MU because of the limits of the minimum MU settings. Beams with 20 × 20 and 10 × 10 cm{sup 2} field sizes were alternately measured ten times in intensity modulated (IM) mode, with which Siemens linacs regulate beam delivery for step-and-shoot IMRT. The in- and crossplane beam profiles were measured using a Profiler™ Model 1170 (Sun Nuclear Corporation, Melbourne, FL) in multiframe mode. The frames of 20 × 20 cm{sup 2} beams were identified at the off-axis profile. The 6X beam profile was normalized at the central axis. The 7 and 11 MV FFF beam profiles were rescaled to set the dose at the central axis at 145% and 170%, respectively. Point doses were also measured using a Farmer-type ionization chamber and water-equivalent solid phantom to evaluate the linearity and consistency of low-MU beam delivery. The values displayed on the electrometer were recognized with a USB-type camera and read with open-source optical character recognition software.Results: The symmetry measurements of the 6X, 7XU, and 11XU beam profiles were better than 2% for beams ≥2 MU and improved with increasing MU. The variations in flatness of FFF beams ≥2 MU were ±5%. The standard deviation of the symmetry and flatness also decreased with increasing MU. The linearity of the 6X beam was ±1% and ±2% for the beams of ≥5 and ≥3 MU, respectively. The 7XU and 11XU beams of ≥2 MU showed linearity with ±2% except the 7XU beam of 8 MU (+2.9%). The profiles of the FFF beams with 2000 and 500 MU/min dose rate were similar.Conclusions: The characteristics of low-MU beams delivered in IM mode were evaluated using an automatic measurement system developed in this study. The authors demonstrated that the profiles of FFF beams of the Artiste™ linac were highly stable, even at low MU. The linearity of dose output was also stable for beams ≥2 MU.

61 RADIATION PROTECTION AND DOSIMETRY↗

Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into files has been added.

43 PARTICLE ACCELERATORS↗