Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKSCATTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Electron backscatter diffraction helps direct calculation of magnetocrystalline anisotropy energy in API 5L steels

Highlights: • Experimental evidence of the capability of EBSD to accurately estimate MAE of API 5L steels. • MAE can be calculated directly from raw EBSD data for reduced sample sizes. • Number of grains sufficient to estimate MAE from EBSD is in the order of several hundreds. • The use of equivalent orientations increases drastically the accuracy of MAE estimations. • EBSD helps explain origin of the observed correlation between MAE and Barkhausen noise. - Abstract: This paper shows evidence of the capability of electron backscatter diffraction (EBSD) to accurately estimate the magnetocrystalline anisotropy energy (MAE) of API 5L steels. The crystallographic texture of five circular steel samples was characterized by X-ray global texture and EBSD microtexture measurements. The average MAE of each one of these samples was estimated from the set of individual grain orientations obtained from orientation maps measured by EBSD. The angular dependence of EBSD-derived MAE was compared with predictions made from X-ray texture and Barkhausen noise (BHN) measurements. The average MAE determined from the EBSD data is in good agreement with the predictions made from X-ray and BHN measurements for all the studied samples. This agreement can be explained by the fact that the number of grains used to predict the average MAE from the EBSD results was statistically sufficient to reproduce the MAE predicted by the other two methods. The EBSD measurement strategy for the accurate MAE estimation was established in terms of parameters such as the number of individual grain orientations to be measured, the sample's texture acuity and grain size, the use of equivalent orientations given by the statistical orthorhombic symmetry of the studied samples, and different measurement planes.

36 MATERIALS SCIENCE↗

Characterization of microtexture of 316L stainless steel fiber after multi-pass drawing by electron backscatter diffraction

Highlights: • Three crystalline phases, γ, α′, and σ, in 316L stainless steel fibers are observed by XRD. • Strain-induced martensite and two types of twin boundaries are formed in drawn fibers. • The twin boundary generation is nucleate at high angle grain boundaries and then bulge into the {112}<111> grain. • A route of the formation mechanism of deformation twins was analyzed by EBSD. - Abstract: The microstructure and microtexture of 316L stainless steel fibers (SSFs) after multi-pass cold drawing with intermediate heat treatment were investigated in this study. The crystalline phases of SSFs were identified and quantified using X-ray diffraction (XRD) analysis. Grain orientation and boundary characterization in the mantle and core regions of drawing direction (DD) were analyzed through electron backscatter diffraction (EBSD). The coincident site lattice approach provides beneficial information for defining twin boundary and analyzing the orientation relationship between neighboring grains on the Σ3 segment. Three crystalline phases, γ, α, and σ, could be seen in XRD profiles. The formation mechanism of deformation twins was found, and two types of twin boundaries were observed in the drawn fibers by EBSD. The twin boundary generated between a {112}<111> grain and a <100>//DD grain is believed to nucleate at a high-angle grain boundary and then bulge into the copper grain.

36 MATERIALS SCIENCE↗

Mapping 180° polar domains using electron backscatter diffraction and dynamical scattering simulations

A novel technique, which directly and nondestructively maps polar domains using electron backscatter diffraction (EBSD) is described and demonstrated. Through dynamical diffraction simulations and quantitative comparison to experimental EBSD patterns, the absolute orientation of a non-centrosymmetric crystal can be determined. With this information, the polar domains of a material can be mapped. The technique is demonstrated by mapping the non-ferroelastic, or 180°, ferroelectric domains in periodically poled LiNbO 3 single crystals. Furthermore, the authors demonstrate the possibility of mapping polarity using this technique in other polar materials system.

36 MATERIALS SCIENCE↗

A Denoising Autoencoder for Improved Kikuchi Pattern Quality and Indexing in Electron Backscatter Diffraction

The rapid collection and indexing of electron diffraction patterns as produced via electron backscatter diffraction (EBSD) has enabled crystallographic orientation and structural determination, as well as additional property-determining strain and dislocation density information with increasing speed, resolution, and efficiency. Pattern indexing quality is reliant on the noise of the collected electron diffraction patterns, which is often convoluted by sample preparation and data collection parameters. EBSD acquisition is sensitive to many factors and thus can result in low confidence index (CI), poor image quality (IQ), and improper minimization of fit, which can result in noisy datasets and misrepresent the microstructure. In an attempt to enable both higher speed EBSD data collection and enable greater orientation fit accuracy with noisy datasets, an image denoising autoencoder was implemented to improve pattern quality. Here, we show that EBSD data processed through the autoencoder results in a higher CI, IQ, and a more accurate degree of fit. In addition, using denoised datasets in HR-EBSD cross correlative strain analysis can result in reduced phantom strain from erroneous calculations due to the increased indexing accuracy and improved correspondence between collected and simulated patterns.

36 MATERIALS SCIENCE↗

Mg segregation in Mg-rich Mg-Ni switchable mirror studied by Rutherford backscattering, elastic recoil detection analysis, and nuclear reaction analysis

Pd/Mg{sub 3.3}Ni films were prepared by dc sputtering deposition on three different substrates of glass, diamondlike carbon/Si, and Si. Hydrogenation and dehydrogenation cycles were performed on these samples simultaneously. The optical switching property due to the hydrogenation and dehydrogenation was monitored by the transmission of laser light via the glass substrate. The switching ability was totally lost after 120 cycles. We made comparative study of the composition change between the new (as-deposited) and old (after 120 switching cycles) samples by Rutherford backscattering (RBS), elastic recoil detection analysis (ERDA), and nuclear reaction analysis (NRA). From the RBS results we found out the segregation of a Mg layer between the Pd cap layer and the rest of the Mg-Ni layer. At the Pd/Mg interface in the old sample, thin MgO layer formed probably during the dehydrogenation process with O{sub 2}. ERDA showed that there is much hydrogen in the old sample. NRA displayed the depth profiles of hydrogen distribution in the old sample. It is revealed that much hydrogen is accumulated at the interface between the Pd cap layer and the segregated Mg layer. It can be concluded that the formations of oxide and hydride of the segregated Mg layer are the main reasons for the degradation of the Mg{sub 3.3}Ni switchable mirror.

36 MATERIALS SCIENCE↗

Detection of Landmines by Neutron Backscattering: Effects of Soil Moisture on the Detection System

Detection of buried land mines by using neutron backscattering technique (NBS) is a well established method. It depends on detecting a hydrogen anomaly in dry soil. Since a landmine and its plastic casing contain much more hydrogen atoms than the dry soil, this anomaly can be detected by observing a rise in the number of neutrons moderated to thermal or epithermal energy. But, the presence of moisture in the soil limits the effectiveness of the measurements. In this work, a landmine detection system using the NBS technique was designed. A series of Monte Carlo calculations was carried out to determine the limits of the system due to the moisture content of the soil. In the simulations, an isotropic fast neutron source ({sup 252}Cf, 100 mug) and a neutron detection system which consists of five {sup 3}He detectors were used in a practicable geometry. In order to see the effects of soil moisture on the efficiency of the detection system, soils with different water contents were tested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel, multichannel, comb-frequency Doppler backscatter system

Doppler backscattering has emerged in recent years as a powerful diagnostic tool in high temperature fusion plasmas. The technique is sensitive to plasma turbulence flow and has been utilized to determine radial electric field and to study geodesic acoustic modes, zonal flows, and intermediate scale density turbulence. The current manuscript describes a novel technique for creating a stable, multichannel system covering the V-band frequency range (50-75 GHz) which enables simultaneous monitoring of turbulent flows and fluctuation levels at eight distinct spatial locations. The system is based on a high-frequency, low phase noise comb-frequency generator combined with a filter bank and quadrature detection system. The system is now in operation on DIII-D and has allowed monitoring of the flow and turbulence levels across the plasma radius during events such as the L-H transition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strain Determination Using Electron Backscatter Diffraction

In the present paper we demonstrate the use of electron backscatter diffraction (EBSD) for high resolution elastic strain determination. Here, we focus on analysis methods based on determination of small shifts in EBSD pattern with respect to a reference pattern using cross-correlation algorithms. Additionally we highlight the excellent spatial and depth resolution of EBSD and introduce the use of simulated diffraction patterns based on dynamical diffraction theory for sensitivity estimation. Moreover the potential of EBSD for strain analysis of strained thin films with particular emphasis on appropriate target preparation which respect to occurring lattice defects is demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron Backscattered Diffraction Analysis Of Narrow Copper Interconnects In Cross-View To Investigate Scale Effect On Microstructure

In this article, we propose to use Electron Backscattered Diffraction (EBSD) to characterize microstructure of copper interconnects of thin metal level in top view and cross view. These two views give very complementary information about microstructure of copper and thus about recrystallization of copper during annealing. Moreover, for minimum width, as interconnect is two times thicker than wide; It will be easier to analyze smaller interconnect of 45 nm node technology in cross-section. We look for evolution of texture and microstructure of copper with line width in top view and in cross view. We highlight the presence of two recrystallization mechanisms and also the fact that transition from one to the other is progressive with competition of both mechanisms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Backscatter x-ray development for space vehicle thermal protection systems

The Backscatter X-Ray (BSX) imaging technique is used for various single sided inspection purposes. Previously developed BSX techniques for spray-on-foam insulation (SOFI) have been used for detecting defects in Space Shuttle External Tank foam insulation. The developed BSX hardware and techniques are currently being enhanced to advance Non-Destructive Evaluation (NDE) methods for future space vehicle applications. Various Thermal Protection System (TPS) materials were inspected using the enhanced BSX imaging techniques, investigating the capability of the method to detect voids and other discontinuities at various locations within each material. Calibration standards were developed for the TPS materials in order to characterize and develop enhanced BSX inspection capabilities. The ability of the BSX technique to detect both manufactured and natural defects was also studied and compared to through-transmission x-ray techniques. The energy of the x-ray, source to object distance, angle of x-ray, focal spot size and x-ray detector configurations were parameters playing a significant role in the sensitivity of the BSX technique to image various materials and defects. The image processing of the results also showed significant increase in the sensitivity of the technique. The experimental results showed BSX to be a viable inspection technique for space vehicle TPS systems.

07 ISOTOPE AND RADIATION SOURCES↗

Improvement of sensitivity in high-resolution Rutherford backscattering spectroscopy

The sensitivity (limit of detection) of high-resolution Rutherford backscattering spectroscopy (HRBS) is mainly determined by the background noise of the spectrometer. There are two major origins of the background noise in HRBS, one is the stray ions scattered from the inner wall of the vacuum chamber of the spectrometer and the other is the dark noise of the microchannel plate (MCP) detector which is commonly used as a focal plane detector of the spectrometer in HRBS. In order to reject the stray ions, several barriers are installed inside the spectrometer and a thin Mylar foil is mounted in front of the detector. The dark noise of the MCP detector is rejected by the coincidence measurement with the secondary electrons emitted from the Mylar foil upon the ion passage. After these improvements, the background noise is reduced by a factor of 200 at a maximum. The detection limit can be improved down to 10 ppm for As in Si at a measurement time of 1 h under ideal conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Depth distribution of silver particulate films deposited in softened polystyrene substrates studied through Rutherford backscattering spectrometry

The depth distribution of silver particulate films deposited on softened polystyrene substrates has been studied through Rutherford backscattering spectrometry (RBS). 150 nm thick silver films were deposited on polystyrene (PS) coated glass substrates held at 455 K and 490 K in a vacuum of 8 x 10{sup -6} Torr. The substrates were irradiated with 8 MeV electrons to a dose of 25 kGy prior to deposition. Ion scattering measurements indicated that the silver particulates are formed at a few tens of nanometers beneath the PS surface for both unirradiated and irradiated substrates. The particulate structure seems to be a two-dimensional array rather than a three-dimensional distribution. The morphology of the particulate structure, the depth of maximum concentration of the particles as well as the width of the distribution seems to depend on the deposition rate and substrate temperature. The electron irradiation of the PS substrate gives rise to the modification of the morphology of the particulate structure due to the induced polymer-metal interaction arising from the free radicals created by the irradiation.

36 MATERIALS SCIENCE↗

Correlating whisker growth and grain structure on Sn-Cu samples by real-time scanning electron microscopy and backscattering diffraction characterization

Whiskers/hillocks grow out of Pb-free Sn coatings used in electronics manufacturing. To determine which grains form whiskers/hillocks, we use scanning electron microscopy and backscattering diffraction to simultaneously monitor the surface morphology and grain structure. To reduce surface roughness, we developed a ''peel-off'' method to prepare ultra-flat samples that were measured repeatedly while whiskers/hillocks formed. We find grains that form into whiskers/hillocks are present in the as-deposited film (i.e., not re-nucleated) and many have horizontal grain boundaries beneath them. Grain rotation during whisker/hillock formation means that measurements performed after the features grow do not indicate their initial grain orientations.

36 MATERIALS SCIENCE↗

SPHERES, Juelich's high-flux neutron backscattering spectrometer at FRM II

SPHERES is a third-generation neutron backscattering spectrometer, located at the 20 MW German neutron source FRM II and operated by the Juelich Centre for Neutron Science. It offers an energy resolution (fwhm) better than 0.65 {mu}eV, a dynamic range of {+-} 31 {mu}eV, and a signal-to-noise ratio of up to 1750:1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2D full wave modeling for a synthetic Doppler backscattering diagnostic

Doppler backscattering (DBS) is a plasma diagnostic used in tokamaks and other magnetic confinement devices to measure the fluctuation level of intermediate wavenumber (k{sub {theta}}{rho}{sub s}{approx} 1) density fluctuations and the lab frame propagation velocity of turbulence. Here, a synthetic DBS diagnostic is described, which has been used for comparisons between measurements in the DIII-D tokamak and predictions from nonlinear gyrokinetic simulations. To estimate the wavenumber range to which a Gaussian beam would be sensitive, a ray tracing code and a 2D finite difference, time domain full wave code are used. Experimental density profiles and magnetic geometry are used along with the experimental antenna and beam characteristics. An example of the effect of the synthetic diagnostic on the output of a nonlinear gyrokinetic simulation is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dissipative and non-dissipative solitons in the SRS- backscattering of laser radiation in underdense plasma

The process of stimulated Raman backscattering of laser pulse in underdense plasma is considered self-consistently in 1D model. Solutions to this problem in the form of backward-propagating bright solitons (the Stokes scattered pulse and the plasma density wave) coupled with the dark soliton in the pump laser pulse are found. These solitary solutions exist both in the non-dissipative (non-collisional plasma) case and in the dissipative (collisional plasma) case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Third harmonic stimulated Raman backscattering of laser in a magnetized plasma

This article studies the nonlinear Raman shifted third harmonic backscattering of an intense extraordinary laser wave through a homogenous transversely magnetized cold plasma. Due to the relativistic nonlinearity, the plasma dynamic is modified in the presence of transversely magnetic field, and this can generate the third harmonic scattered wave and an electrostatic upper hybrid wave via the Raman scattering process. Using the nonlinear wave equation, the mechanism of nonlinear third harmonic Raman scattering is discussed in detail to obtain the maximum growth rate of instability in the mildly relativistic regime. The growth rate decreases as the static magnetic field increases. It also increases with the pump wave amplitude.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗