Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Average Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

A vertically integrated snow/ice model over land/sea for climate models. I - Development. II - Impact on orbital change experiments

A vertically integrated formulation (VIF) model for sea ice/snow and land snow is discussed which can simulate the nonlinear effects of heat storage and transfer through the layers of snow and ice. The VIF demonstates the accuracy of the multilayer formulation, while benefitting from the computational flexibility of linear formulations. In the second part, the model is implemented in a seasonal dynamic zonally averaged climate model. It is found that, in response to a change between extreme high and low summer insolation orbits, the winter orbital change dominates over the opposite summer change for sea ice. For snow over land the shorter but more pronounced summer orbital change is shown to dominate.

Neeman, Binyamin U.↗

Measurement and modeling of land mobile satellite propagation at UHF and L-band

A propagation experiment is described in which a stratospheric balloon served as a transmitter platform at 870 and 1502 MHz in simulation of a land mobile satellite. A vehicle followed the drifting balloon along roads of western Texas and New Mexico, collecting at L-band amplitude and phase, and at UHF amplitude information only for elevation angles between 25 and 45 deg. The data obtained have been analyzed and are presented along with results from modeling of multipath scattering and roadside tree attenuation. The signal, with variations caused by multipath propagation and tree shadowing, was reduced by 3 dB at L-band and 2 dB at UHF for one percent of all locations. A median ratio of 3.9 was found between peak-to-peak phase (degrees) and power (dB) fluctuations. The ratio between L-band and UHF dB attenuation averages varied from 1.3 to 1.0 at fade levels from 6 to 23 dB. Optical sky brightness was measured and used to predict fade distribution with great accuracy. A single-scatterer multipath model is introduced. It is used to duplicate some of the measured data and to show the dependence of power variations on satellite elevation angle. Using Fresnel diffraction theory, the attenuation caused by a model tree was calculated to be near 10 dB and the maximum fade was found to increase by the logarithm of the number of branches.

Vogel, Wolfhard J.↗

Functional description of signal processing in the Rogue GPS receiver

Over the past year, two Rogue GPS prototype receivers have been assembled and successfully subjected to a variety of laboratory and field tests. A functional description is presented of signal processing in the Rogue receiver, tracing the signal from RF input to the output values of group delay, phase, and data bits. The receiver can track up to eight satellites, without time multiplexing among satellites or channels, simultaneously measuring both group delay and phase for each of three channels (L1-C/A, L1-P, L2-P). The Rogue signal processing described requires generation of the code for all three channels. Receiver functional design, which emphasized accuracy, reliability, flexibility, and dynamic capability, is summarized. A detailed functional description of signal processing is presented, including C/A-channel and P-channel processing, carrier-aided averaging of group delays, checks for cycle slips, acquistion, and distinctive features.

Thomas, J. B.↗

Limitations of the Pilot in Applying Forces to Airplane Controls

Measurements were made to determine the relative maximum forces a pilot can exert on the controls of an airplane with the view of obtaining systematic data upon which to base the location of controls within the cockpit and the design of the control surfaces. A cockpit model of generous proportions, capable of being rotated to any attitude, was built with the location of the control stick and rudder pedals adjustable over a wide range of positions with respect to the seat. Besides measurements of maximum forces obtainable with various control locations and with the pilot in several attitudes, estimates of forces within the range normally encountered in flight were made to gain an indication of the accuracy of estimating control forces. The maximum aileron forces measured were of the order of 90 pounds, maximum elevator 200 pounds, and maximum rudder 450 pounds. The average forces applied with the controls in the neutral position for the various cockpit attitudes were of the order of 35, 95, and 400 pounds, respectively, for the ailerons, elevators, and rudder.

Gough, M N↗

Multiresolution Representation Using Biorthogonal Multiwavelets

We generalize Harten's multiresolution representation to biorthogonal multiwavelets. Several variants are considered. For example, a given array of discrete point values is transformed to point values and derivatives or point 'values and cell averages'. Compact Hermite interpolation is used in the decomposition and reconstruction algorithm. The resulting basis functions that are symmetric or skewsymmetric, compact, and smooth with optimal order accuracy. Harten's approach has several advantages: the multiresolution scheme is inherently discrete, non-periodic boundary conditions are easy to implement, and the representation can be extended to unstructured grids in bounded domains. We demonstrate the compression features of the new mutliwavelets by application to variable scale piecewise smooth functions with jump discontinuities typical of numerical solutions of nonlinear hyperbolic conservation laws.

Warming, Robert F.↗

Rotor-Stator Interaction Performance Effects

Decreased axial spacing between blade rows in an axial compressor stage is thought to increase stage performance because of an unsteady process that occurs in the downstream blade row and acts on the upstream blade row wakes. This process results in the "recovery" of part of the wake energy before all of this energy is irreversibly lost due to viscous diffusion. To study the wake-blade interaction mechanism, researchers at the NASA Lewis Research Center acquired two-component Laser Fringe Anemometer measurements of the rotor wake in the single-stage transonic compressor at two stage loading levels. The detailed measurements were acquired for one stator pitch in circumference at axial positions from the rotor trailing edge to 20 percent of the stator axial chord, at the exit of the stator passage, and downstream of the stator row including the stator wake. These data show that the changes in wake energy that occur inside the stator passage are not due to viscous dissipation alone, and thus the data provide evidence that "wake recovery" is occurring. A time-accurate, three-dimensional Navier Stokes simulation of the compressor stator was done at the corresponding stage loading levels. The measurements and simulations are being used in combination to show the effects of stator blade loading, quantify the effects of viscosity, and quantify the stage efficiency gain due to the wake recovery process. The accuracy of simple models of the wake recovery process is being evaluated in an effort to include the effects of wake recovery in the NASA-developed Average Passage code for multistage turbomachinery simulations.

VanZante, Dale E.↗

A Deterministic Computational Procedure for Space Environment Electron Transport

A deterministic computational procedure for describing the transport of electrons in condensed media is formulated to simulate the effects and exposures from spectral distributions typical of electrons trapped in planetary magnetic fields. The primary purpose for developing the procedure is to provide a means of rapidly performing numerous repetitive transport calculations essential for electron radiation exposure assessments for complex space structures. The present code utilizes well-established theoretical representations to describe the relevant interactions and transport processes. A combined mean free path and average trajectory approach is used in the transport formalism. For typical space environment spectra, several favorable comparisons with Monte Carlo calculations are made which have indicated that accuracy is not compromised at the expense of the computational speed.

Nealy, John E.↗

Automated Semantic Segmentation for Volumetric Cardiovascular Feature Quantification and Pathology Assessment

We present a pipeline method that curtails the expense and observer bias of manual cardiac evaluation by combining semantic segmentation and disease classification as a fully automatic processing pipeline. The initial element consists of a 2D U-Net convolutional neural network architecture for voxel-wise segmentation of the myocardium and ventricular cavities. The results of the segmentation were used to compute a comprehensive volumetric feature matrix that captured diagnostic clinical procedure data and that was used to model a cardiac pathology classifier.Our approach evaluated anonymized parasternal MRI cardiac images from a database of 100 patients (4 pathology groups, 1 healthy group, 20 patients per group) examined at the University Hospital of Dijon. We achieved top average Dice index scores of 0.939, 0.849, 0.886 for structure segmentation of the left ventricle (LV), right ventricle (RV) and myocardium respectively. A 5-ary pathology classification accuracy of 90% was recorded on an independent test set using our trained model.

Lindsey, Tony↗

TPSAS-NF1676L-10737-DND

The Clouds and the Earth's Radiant Energy System (CERES) project provides the community a quality climate TOA and surface fluxes and cloud properties and are key elements in evaluating the ability of climate models to predict both past and future climate states. One important aspect of successful climate monitoring is satellite calibration. The CERES instantaneous broadband calibration radiance stability is 0.1% per year, whereas the accuracy of the longwave (LW) and shortwave (SW) is better than 0.5% and 1% respectively. CERES uses the 3-hourly GEO fluxes and clouds to provide diurnally averaged daily and monthly TOA flux means from the CERES measurements onboard the Terra (10:30 AM local equator crossing time) and Aqua (13:30 PM) sun-synchronous satellites. The GEO radiances are calibrated against MODIS as a reference to provide consistent GEO retrieved cloud properties and derived broadband fluxes. These fluxes are then carefully normalized against the well-calibrated CERES fluxes to ensure climate quality fluxes, free of GEO artifacts. With the upcoming release of Edition3 products, CERES has just recalibrated all the CERES instruments to ensure that both Terra and Aqua fluxes are on the same radiometric scale and the removal of all known instrument trends. CERES will also recalibrate all GEO satellites using the entire GEO time record. CERES employs collocated, coincident ray-matched GEO/MODIS radiances as its primary technique, calibrating GEO radiances beginning in the year 2000. The advantage of the ray-matching technique is that it provides a full dynamic range of radiances to check the linearity of the GEO visible instrument. CERES uses deep convective clouds and invariant desert sites to validate the primary technique. All three methods can assess the stability of the GEO visible instrument. Examples of the CERES GEO calibration techniques and validation efforts will be shown at the conference. Special emphasis will be given to the newly incorporated desert site methodology.

R. Bhatt↗

Field Evaluation of Portable Soil Water Content Sensors in a Sandy Loam

Ground observations are critical in the validation of soil water content (SWC) estimates from both satellites and land surface models. Portable SWC sensors provide useful information to determine the amount of SWC in the topsoil layer for various applications; however, these probes are not accurate without site‐specific correction. In the present study, we examined and compared six different types of portable electromagnetic (EM) SWC sensors, including multiple sensors made by the same manufacturers, for a total of 16 EM‐based SWC probes equipped with portable data loggers. All SWC probes met the target accuracy after onsite correction—the RMSD was <0.025 m(exp 3) m(exp -3). Using the two‐sample t-tests, we observed that SWC data obtained from similar electrode lengths and from different manufacturers showed similar distributions over time with the same mean. Furthermore, using the maximize R method to combine SWC data from two different types of sensors increased the accuracy of the results. When datasets from two different types of sensors were combined, the Pearson's correlation coefficient (R value) and RMSD values were improved. The average R value improved from .930 to .945, and the RMSD decreased from 0.036 m(exp 3) m(exp -3) to 0.018 m(exp 3) m(exp −3). These results indicate that, along with site‐specific correction, synergetic use of multiple manufacturers’ EM‐based SWC probes can improve the R value and reduce systematic bias.

soil moisture data↗

The impact of satellite soundings and their distribution on forecast accuracy

The impact of satellite data is found to vary considerably from one map to another and from one geographic region to another. However, the impact of satellite data is generally small in comparison with forecast error. On the average, over land areas (where good conventional data permit accurate verification), the impact of satellite data on 48-hr forecasts of 500-mb height is seen to be neutral. Indirect numerical evidence is found, however, that satellite data has a marked positive impact in the lower and middle troposphere in ocean regions, especially those regions where conventional data are sparse. The impact over oceans is found to be especially noticeable in maps depicting the mean differences between the satellite and the conventional-data-only maps averaged over the period of the data set (January 1-14, 1980), both for analyses and for forecasts to 48 hours.

Thomasell, A., Jr.↗

Measurements of ultrasonic velocities using a digital averaging technique.

A new pulse-echo technique using real-time digital averaging is described for measuring the phase velocity in solids up to 50 MHz. The technique can measure the transit time between any two echoes to an absolute accuracy of 0.1 nsec and measure small changes in transit time to a sensitivity of 20 psec. Experimental examples are given based upon ultrasonic velocity measurements in a single crystal superconductor.

Lacy, L. L.↗

Capabilities of operational infrared sounding systems from satellite altitude

Initial attempts at using satellite radiances resulted in the production of temperature profiles similar to those produced by radiosondes. While increases in accuracy were made and additional increases are expected to result from increased instrument capabilities, it was recognized that the production of level temperatures is not consistent with the average temperature that is represented by the radiances.

Mcmillin, L.↗

Registration of interferometric SAR images

Interferometric synthetic aperture radar (INSAR) is a new way of performing topography mapping. Among the factors critical to mapping accuracy is the registration of the complex SAR images from repeated orbits. A new algorithm for registering interferometric SAR images is presented. A new figure of merit, the average fluctuation function of the phase difference image, is proposed to evaluate the fringe pattern quality. The process of adjusting the registration parameters according to the fringe pattern quality is optimized through a downhill simplex minimization algorithm. The results of applying the proposed algorithm to register two pairs of Seasat SAR images with a short baseline (75 m) and a long baseline (500 m) are shown. It is found that the average fluctuation function is a very stable measure of fringe pattern quality allowing very accurate registration.

Lin, Qian↗

The JPL Hg(sup +) Extended Linear Ion Trap Frequency Standard: Status, Stability, and Accuracy Prospects

Microwave frequency standards based on room temperature (sup 199)Hg(sup +) ions in a Linear Ion Trap (LITS) presently achieve a Signal to Noise and line Q inferred short frequency stability. Long term stability has been measured for averaging intervals up to 5 months with apparent sensitivity to variations in ion number/temperature limiting the flicker floor.

Hg+ linear ion trap frequency LITE LITS microwave ↗

New and Improved T-wave Morphology Parameters to Differentiate Healthy Individuals from those with Cardiomyopathy and Coronary Artery Disease

We investigated the ability of several known as well as new ECG repolarization parameters to differentiate healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. The following multiple parameters of T-wave morphology (TWM) were derived via signal averaging and singular value decomposition (SVD, which yields 8 eigenvalues, rho(sub 1) greater than rho(sub 2)...greater than rho(sub 8) and studied for their retrospective accuracy in detecting underlying disease: 1) Principal component analysis ratio of the T wave (T-PCA) = 100*rho(sub 2)/rho(sub 1); 2) Relative T-wave residuum (rTWR) = 100* SIGMA (rho(sub 4)(sup 2) +...+ rho(sub 8)(sup 2)); 3) Modified complexity ratio of the T wave (T-mCR) = 100*SIGMA(rho(sub 3)(sup 2) +...+rho(sb 8) (sup 2)); and 4) Normalized 3-dimensional volume of the T wave (nTV) = 100*(rho(sub 2)*rho(sub 3)/rho(sub 1)(sup 2). All TWM parameters significantly differentiated CAD from controls (p less than 0.0001), and also CM from controls (p less than 0.0001). Retrospective areas under the ROC curve were 0.77, 0.81, 0.82, and 0.83 (CAD vs. controls) and 0.93, 0.89, 0.95 and 0.96 (CM vs. controls) for T-PCA, rTWR, T-mCR and nTV respectively. The newer TWM parameters (T-mCR and nTV) thus outperformed the more established parameters (T-PCA and rTWR), presumably by putting a greater emphasis on the third T-wave eigenvalue, which in most healthy subjects has little energy compared to the first two eigenvalues. Subsequent prospective analyses have also yielded similar results, such that we conclude that diagnostic differentiation of pathology from non-pathology may be especially aided by detecting the transference of energy from the first and second T-wave eigenvalues into the third T-wave eigenvalue.

Greco, E. C.↗

Gravity Probe B Timing System and Roll Phase Determination

An oven-controlled crystal oscillator at 16.368 MHz provides clock signals to all GP-B components and synchronizes the data collection, transmission and processing. The sampled science data signals are stamped with the vehicle time, a counter of the 10Hz data strobe divided down from the clock. The GPS receiver supplies an external reference for time transfer between the vehicle time and coordinated universal time. Ground and space flight tests show the time transfer error is within 1 microsecond. The time latency between the effective sample time of science signals and the stamped vehicle time is verified to 1 ms in the ground tests. The GP-B satellite is controlled to roll with a period of 77.5 sec about an axis along the direction to the guide star to average out the disturbance torques fixed to the body of the satellite and reduce the gyroscope readout noise. The roll phase is determined on the ground to high accuracy with the telemetry data from two star trackers and used in the data analysis to separate the drifts of gyroscope spin axes in the orbital plane and perpendicular to the orbital plane. The flight data shows that the roll phase is controlled to within 40 arcsec with a measurement uncertainty of 7 arcsec.

Jie, Li↗

Carnegie Hubble Program: A Mid-Infrared Calibration of the Hubble Constant

Using a mid-infrared calibration of the Cepheid distance scale based on recent observations at 3.6 micrometers with the Spitzer Space Telescope, we have obtained a new, high-accuracy calibration of the Hubble constant. We have established the mid-IR zero point of the Leavitt law (the Cepheid period-luminosity relation) using time-averaged 3.6 micrometers data for 10 high-metallicity, MilkyWay Cepheids having independently measured trigonometric parallaxes. We have adopted the slope of the PL relation using time-averaged 3.6micrometers data for 80 long-period Large Magellanic Cloud (LMC) Cepheids falling in the period range 0.8 < log(P) < 1.8.We find a new reddening-corrected distance to the LMC of 18.477 +/- 0.033 (systematic) mag. We re-examine the systematic uncertainties in H(sub 0), also taking into account new data over the past decade. In combination with the new Spitzer calibration, the systematic uncertainty in H(sub 0) over that obtained by the Hubble Space Telescope Key Project has decreased by over a factor of three. Applying the Spitzer calibration to the Key Project sample, we find a value of H(sub 0) = 74.3 with a systematic uncertainty of +/-2.1 (systematic) kilometers per second Mpc(sup −1), corresponding to a 2.8% systematic uncertainty in the Hubble constant. This result, in combination with WMAP7measurements of the cosmic microwave background anisotropies and assuming a flat universe, yields a value of the equation of state for dark energy, w(sub 0) = −1.09 +/- 0.10. Alternatively, relaxing the constraints on flatness and the numbers of relativistic species, and combining our results with those of WMAP7, Type Ia supernovae and baryon acoustic oscillations yield w(sub 0) = −1.08 +/- 0.10 and a value of N(sub eff) = 4.13 +/- 0.67, mildly consistent with the existence of a fourth neutrino species.

Program↗