Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Atomic spectral lines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

478 records · Page 27

High Resolution, Non-Dispersive X-Ray Calorimeter Spectrometers on EBITs and Orbiting Observatories

X-ray spectroscopy is the primary tool for performing atomic physics with Electron beam ion trap (EBITs). X-ray instruments have generally fallen into two general categories, 1) dispersive instruments with very high spectral resolving powers but limited spectral range, limited count rates, and require an entrance slit, generally, for EBITs, defined by the electron beam itself, and 2) non-dispersive solid-state detectors with much lower spectral resolving powers but that have a broad dynamic range, high count rate ability and do not require a slit. Both of these approaches have compromises that limit the type and efficiency of measurements that can be performed. In 1984 NASA initiated a program to produce a non-dispersive instrument with high spectral resolving power for x-ray astrophysics based on the cryogenic x-ray calorimeter. This program produced the XRS non-dispersive spectrometers on the Astro-E, Astro-E2 (Suzaku) orbiting observatories, the SXS instrument on the Astro-H observatory, and the planned XMS instrument on the International X-ray Observatory. Complimenting these spaceflight programs, a permanent high-resolution x-ray calorimeter spectrometer, the XRS/EBIT, was installed on the LLNL EBIT in 2000. This unique instrument was upgraded to a spectral resolving power of 1000 at 6 keV in 2003 and replaced by a nearly autonomous production-class spectrometer, the EBIT Calorimeter Spectrometer (ECS), in 2007. The ECS spectrometer has a simultaneous bandpass from 0.07 to over 100 keV with a spectral resolving power of 1300 at 6 keV with unit quantum efficiency, and 1900 at 60 keV with a quantum efficiency of 30%. X-ray calorimeters are event based, single photon spectrometers with event time tagging to better than 10 us. We are currently developing a follow-on instrument based on a newer generation of x-ray calorimeters with a spectral resolving power of 3000 at 6 keV, and improved timing and measurement cadence. The unique capabilities of the x-ray calorimeter spectrometer, coupled with higher spectral resolution dispersive spectrometers to resolve line blends, has enabled many science investigations, to date mostly in our x-ray laboratory astrophysics program. These include measurements of absolute cross sections for Land K shell emission from Fe and Ni, charge exchange measurements in many astrophysically abundant elements, lifetime measurements, line ratios, and wavelength measurements. In addition, we have performed many additional measurements in nuclear physics, and in support of diagnostics for laser fusion, for example. In this presentation we will give a detailed overview of x-ray calorimeter instruments in general and in our EBIT laboratory astrophysics program in particular. We will also discuss the science yield of our measurements at EBIT over the last decade) prospects for future science enabled by the current generation of spectrometers and that will be expanded in the near future by the next generation of spectrometers starting in 2611.

Porter, Frederick S.↗

Benchmark of the Fe xvv 𝓡 ratio in photoionized plasma during eclipse of Centaurus X-3 with XRISM/Resolve

The $\mathcal {R}$ ratio is a useful diagnostic of the X-ray emitting astrophysical plasmas and is defined as the intensity ratio of the forbidden over the inter-combination lines in the K$\alpha$ line complex of He-like ions. The value is altered by excitation processes (electron impact or UV photoexcitation) from the metastable upper level of the forbidden line, thereby constraining the electron density or UV field intensity. The diagnostic has been applied mostly in electron density constraints in collisionally ionized plasmas using low-Z elements, as was originally proposed for the Sun (Gabriel & Jordan, 1969a, MNRAS, 145, 241), but it can also be used in photoionized plasmas. To make use of this diagnostic, we need to know its value in the limit of no excitation of metastables ($\mathcal {R}_{0}$), which depends on the element, how the plasmas are formed, how the lines are propagated, and the spectral resolution affecting line blending principally with satellite lines from Li-like ions. We benchmark $\mathcal {R}_0$ for photoionized plasmas by comparing calculations using radiative transfer codes and observation data taken with the Resolve X-ray microcalorimeter onboard XRISM. We use the Fe xxv He$\alpha$ line complex of the photo-ionized plasma in Centaurus X-3 observed during eclipse, in which the plasma is expected to be in the limit of no metastable excitation. The measured $\mathcal {R} = 0.65 \pm 0.08$ is consistent with the value calculated using xstar for the plasma parameters derived from other line ratios of the spectrum. We conclude that the $\mathcal {R}$ ratio diagnostic can be used for high-Z elements such as Fe in photoionized plasmas, which has wide applications in plasmas around compact objects at various scales.

X-rays: binaries↗

Titanium alloy response sensitivity to variations in spectral reconstructions of National Ignition Facility xenon line-emission x-ray sources

Thermomechanical shock experiments on the National Ignition Facility (NIF) aim to study high strain rate dynamic material response. In such experiments, the NIF laser is used to generate high fluence x-ray emission sources, which irradiate material samples of interest. Under sufficiently high x-ray energy deposition, thermomechanical impulses are generated in the materials. While it is known that the characteristics of x-ray generated impulses vary as a function of incident x-ray spectra, it remains unclear how spectral assumptions and uncertainties in NIF spectral reconstructions affect our interpretation of impulsive loading. Here, in this paper, we simulate the response of a standard titanium alloy baseline sample to synthetic analytically derived and measured NIF xenon line-emission x-ray sources with a radiation hydrodynamics code. We vary the source spectral characteristics based on different source reconstruction techniques to understand the resulting variation in baseline sample response and compare the simulated response with experimental results. We find that the response is highly sensitive to assumptions made about the spectral contents and that knowledge of spectral uncertainties bounds our understanding of the resulting material response. The results of this effort help to extend our ability to use baseline material samples to extract quantitative properties from x-ray experiments on the NIF.

Alloys↗

Removing Spectral Diagnostics of Galactic and Stellar X-Ray Emission from Charged Exchange Recombination

Our research uses the electron beam ion trap (EBIT) at the Lawrence Livermore National Laboratory to study X-ray emission from the charge exchange (CX) of highly charged ions with neutral gases. The resulting data help to fill a void in existing experimental and theoretical understanding of this atomic physics process, and are needed to explain all or part of the observed X-ray emission from the soft X-ray background, stellar winds, the Galactic Center and Galactic Ridge, supernova ejecta, and photoionized nebulae. Appreciation of the astrophysical relevance of our work continues to grow with the publication of roughly a dozen papers in the past four years describing Chandra and XMM observations of geocoronal and heliospheric CX emission, the temporal variation of such emission and correlation with X-ray emission enhancements observed by ROSAT, the theoretical spatial distribution of that emission, and CX emission around other stars. A similar number of papers were also published during that time describing CX emission from planets and comets. We expect that the launch of ASTRSE2, with its second-generation XRS microcalo- (with 6-eV resolution), will reveal even more clearly the contributions of CX to astrophysical emission. In our EBIT work we collected CX spectra from such ions as H-like and He-like Ne, Ar, and Fe. Our early measurements were made with a high-purity Ge detector, but during the second year we began operation of the first-generation XRS microcalorimeter (a twin of the XRS on ASTRO-E) and greatly improved the resolution of our measurements from roughly 150 eV (FWHM) with the Ge detectors to 10 eV with the XRS. We found that saturation of the XRS counting apparatus, which we described in our proposal as a potential concern, is not a problem for studying CX. During the course of our research, we expanded the number of injection gases permitted by the LLNL safety team, purchased and eventually operated an atomic H source, and clearly demonstrated the feasibility of our longer-range plan. For example, we successfully injected He into EBIT (not a small feat because of the difficulty of maintaining a good vacuum with He and avoiding electrical breakdown) to collect a H-like oxygen CX spectrum. The highest energy CX spectrum recorded with the XRS to date is that of the Ar K-shell emission. These measurements provided the first observation of the relative intensity ratios of resolved He-like singlet and triplet n=2->1 lines. We also carried out measurements of He-like Ne as a function of collision energy (i.e., ion temperature). Significant differences in the resulting x-ray spectra were noted. In all cases, the intensity of high-n H-like Lyman lines is significantly higher than current theoretical CX models predict.

Wargelin, Brad↗

First Measurement of Z Opacity Sample Evolution near Solar Interior Conditions Using Time-Resolved Spectroscopy

Opacity model differences with Fe opacity measurements at high temperature (T>1⁢8⁢0 eV ) and high electron density (𝑛 𝑒 >3×10 22 cm −3 ) at nearly solar interior conditions have remained unresolved [Bailey et al., Nature 517, 56 (2015) and Nagayama et al., Phys. Rev. Lett. 122, 235001 (2019)]. Systematic errors from temporal gradients are one hypothesis for the discrepancy. Past data recorded on x-ray film provided spectral measurements over a time determined by the 2.8-ns backlighter duration. Here, we present the first measurements of opacity sample temporal evolution using novel hCMOS ultrafast x-ray camera technology. The measured conditions, measured backlighter time history, and modeled opacities are used to show that temporal gradients do not resolve the model-data discrepancy. The methods demonstrated provide potential advantages, including opacities at more extreme conditions, spectral line shift measurements, and improved measurements at other facilities.

atomic spectra↗

Increased Ly α Opacity in White Dwarf Photospheres from Transient H − Resonances

The structure and emergent flux of hydrogen atmosphere white dwarfs depend on the opacity of the Lyα and Lyβ spectral lines. The opacity here is set by the strength and broadening of these lines; the latter is dictated by the far line wing, which is in the “quasi-static” limit of electron broadening, placing it in the incomplete collision regime, and describes the transient parts of electron and ion collisions. These transient stages of the collision form resonances: In the case of ions, they manifest as molecular resonances, while for electrons they are H − resonances, both of which can only be captured quantum-mechanically. Quantum-mechanical calculations have historically preserved only a handful of broadening terms that are most important near the center of the line. However, in the wings of the line, the previously neglected terms that describe the transient stages of the collision need to be included. This requirement arises because, in the line wings, the broadening from the 1s ground state, which is generally assumed to be extremely small compared to the broadening of the upper state, is no longer negligible within a quantum-mechanical model that takes into account exchange interactions. The inclusion of all the transient terms results in asymmetries and extra broadening. The increased broadening of Lyα increases the opacity at the energy where most of the flux leaves the star. The broader Lyα lines also impact the visible flux, raising it by an amount that exceeds previously estimated errors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Oxygen Opacity Measurements at High-Energy-Density Conditions

We present the first benchmark measurements of oxygen opacity at high-energy-density, crucial for understanding stellar interiors. A 3–5−μm thick SiO 2 sample was heated using a Z facility x-ray source, and opacity was measured in the 5–19.5 Å range with multiple spectrometers. The electron temperature and density inferred from Si 𝐾-shell spectra were 148 ± 4 eV and 8.6 ±1.4 × 10 21 cm −3 , respectively. Six experiments showed opacity reproducibility within ±15% and 5%–25% opacity uncertainty. Measured oxygen opacity and seven different opacity models exhibit extraordinary overall agreement. Discrepancies near the H-like photon ionization threshold and in certain spectral lines suggest the need for model refinements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗

Diffused ionized gas in the spiral galaxy M31

We present a study of diffuse ionized gas (DIG, or WIM for warm ionized medium) in the nearby spiral M31, based on charge coupled device (CCD) imagery in H alpha and (S II) emission lines. We find that the DIG in M31 contributes 40% of the observed total H alpha luminosity, and at least 20% of the total after correction for extinction. This fraction is constant across the disk of M31. The total H alpha luminosity of M31, corrected for extinction, is about 4.1 x 10(exp 40) ergs/s. This implies a low star formation rate of about 0.35 M solar mass/yr, in agreement with earlier estimates. DIG is concentrated near regions of star formation. The average emission measure (EM) perpendicular to the disk ranges from about 6 pc cm(exp-6) in weaker spiral arms to 15 pc cm(exp-6) in the main spiral arms, with (rare) peak values reaching 50 pc cm(exp-6). Overall, the EM in the main arms is substantially higher than that of DIG in the solar neighborhood, implying higher power requirements per unit area in these regions of M31. However, the strong concentration of DIG near regions of star formation keeps the total area covered by DIG in M31 relatively small, which makes it possible to sustain this gas in spite of the low star formation rate. We argue that the DIG extent in vertical direction in M31 may well be lower than in our Galaxy, because of its low star formation rate. A simple parameterization of the electron distribution then shows that the DIG in the spiral arms may contribute between 15% and 40% of the total atomic gas column. The average electron densities implied by the high EMs reached in some regions seem to indicate a higher thermal pressure in the DIG than in the diffuse H I gas in M31. This pressure in-equilibrium can be avoided if part of the diffuse emissions due to a denser component, as proposed most recently by Miller & Cox, because this would reduce the EM and implied pressures for the actual widespread DIG. Column densities of the ionized gas might then be lower as well. We also show, however, that it is not possible to attribute all of the diffuse emission to a relatively dense component, such as earlier proposed extended low-density H II regions. The DIG in M31 shows an overall (S II)/H alpha intensity ratio of 0.5, significantly higher than in discrete H II regions, and similar to that in other galaxies. This number does not vary with radius in M31. There is a suggestion that (S II)/H alpha intensity may be higher at the lowest detectable emission measures, up to 0.7 or even 1. The discrete source population in M31 also shows a trend toward increasing (S II)/H alpha flux ratios as the sources become more diffuse. Few sources (apart from supernova remnants), however, reach the value of 0.5 found in the DIG as a whole. The distinct spectral signature of the DIG in M31, and its energy requirements favor photoionization of the gas, although it is likely that shock ionization occurs in selected regions.

Walterbos, Rene A. M.↗

XRISM view of a stellar flare: High-resolution Fe K spectra of HR 1099, an RS CVn-type star

A high-resolution X-ray spectroscopic observation was made of the RS CVn-type binary star HR 1099 using the Resolve instrument onboard XRISM for its calibration purposes. During the $\sim$400 ks telescope time covering 1.5 binary orbit, a flare lasting for $\sim$100 ks was observed with a released X-ray radiation energy of ${\sim }10^{34}$ erg, making it the first stellar flare ever observed with an X-ray microcalorimeter spectrometer. The flare peak count rate is 6.4 times higher than that in quiescence and is distinguished clearly in time thanks to the long telescope time. Many emission lines were detected in the 1.7–10 keV range both in the flare and quiescent phases. Using the high spectral resolution of Resolve in the Fe K band (6.5–7.0 keV), we resolved the inner-shell lines of Fe XIX-XXVI as well as the outer-shell lines of Fe XXV-XXVI . These lines have peaks in the contribution functions at different temperatures over a wide range, allowing us to construct the differential emission measure (DEM) distribution over the electron temperature of 1–10 keV (roughly 10–100 MK) based only on Fe lines, thus without an assumption of the elemental abundance. The reconstructed DEM has a bimodal distribution, and only the hotter component increased during the flare. The elemental abundance was derived based on the DEM distribution thus constructed. A significant abundance increase was observed during the flare for Ca and Fe, which are some of the elements with the lowest first ionization potential among those analyzed, but not for Si, S, and Ar. This behavior is seen in some giant solar flares and the present result is a clear example in stellar flares.

Astronomy and AstroPhysics↗