Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Aquifer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

PORFLOW Modeling of Vadose Zone Flow and Transport for E-Area Intermediate Level Vault

In support of the E-Area Performance Assessment, a two-dimensional model of water flow and radionuclide transport through the E-Area Intermediate Level Vault (ILV) and local vadose zone has been developed using the PORFLOW TM software. The purpose of the model is to calculate flux to the water table for radionuclides eluted from the ILV during its operational life, the period of institutional control, and times following site closure. Results of model calculations will be used by a three-dimensional PORFLOW model of transport through the aquifer to determine radionuclide concentrations at a hypothetical 100 meter well and at the site boundary where contaminated groundwater is accessible to members of the public following site closure.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computed Tomography Scanning and Petrophysical Measurements of the Wellington KGS 2-32 Core

This report describes the use of the computed tomography facilities and the Multi-Sensor Core Logger at the National Energy Technology Laboratory in Morgantown, West Virginia to characterize core from the Wellington KGS 2-32 well (API 15-191-22770). Core from the well was obtained as part of the Small-Scale Field Test Demonstrating Carbon Dioxide Sequestration in Arbuckle Saline Aquifer and by CO 2 -Enhanced Oil Recovery at Wellington Field, Sumner County, Kansas (DE-FE0006821). The primary impetus of this work was to capture a detailed a digital representation of the core from the Wellington KGS 2-32 well (Sumner County, Kansas). The collaboration between the U.S. Department of Energy’s (DOE) NETL and the Kansas Geological Survey (KGS) at the University of Kansas enables other research entities to access information about this potential carbon storage location and formations. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/wellington2-32-core.

47 OTHER INSTRUMENTATION↗

Effects of Intrusive Confining Units on Groundwater Flow at Pahute Mesa, Nevada National Security Site

Geological, geophysical, hydrogeological, and hydrological evidence indicates that feeder dikes to lava flows play a role as confining units in the groundwater flow system underlying the Pahute Mesa area of underground nuclear testing at the Nevada National Security Site (NNSS). Of geological significance, the Pahute Mesa testing area is largely situated within the Silent Canyon caldera, which includes both tuffs and lavas that were fed by (and are connected to) intrusive rock units such as feeder dikes prior to and during volcanic eruptions (Orkild et al., 1968; Byers et al., 1976). Groundwater modeling results presented in this report support extension of “pool-dam” and “breach scenario” concepts presented in Jackson and Fenelon (2018) and Jackson et al. (2021) to low-permeability intrusive confining units (ICUs) such as feeder dikes that are expected to dissect and ring the caldera. As laterally extensive, steeply-dipping, and sub-parallel planar structures, ICUs can be expected to further compartmentalize groundwater flow in the volcanic aquifers systems at Pahute Mesa beyond the stratigraphically-defined tuff confining units (TCUs). ICUs provide an explanation for changes in water levels before and after the Cheshire test, detonated 2/14/76 (USDOE, 2015), and the unusually high horizontal gradient southwest of Cheshire. These ICU concepts are supported by groundwater modeling results presented in this report. The evidence and groundwater modeling results indicate that the downgradient extent of radionuclide contamination in some areas of Pahute Mesa could be overestimated by ignoring the confining effects of ICUs. On the other hand, contaminant extent could be underestimated by not considering transient flow effects and/or the re-equilibrated flow field caused by breaching of an ICU by an underground nuclear test.

54 ENVIRONMENTAL SCIENCES↗

Adaptive Site Management Strategies for the Hanford Central Plateau Groundwater

Adaptive site management (ASM) is a systematic and iterative management approach that can be used to expedite the remediation of large and/or complex sites. ASM is defined as a formal and systematic project or site management approach centered on rigorous site planning and a firm understanding of site conditions and uncertainties, using science and technology to routinely re-evaluate and prioritize site remedial actions and characterization activities. The goal of the approach is to create a framework of structured and continuous planning, implementation, and assessment processes that accommodates new information and changing site conditions to develop effective and efficient cleanup approaches that achieves the required outcome(s) while optimizing costs, cleanup timeframe, and performance. Central to ASM is an evolving conceptual site model (CSM). Over time, incremental reductions in uncertainty associated with the CSM will occur, while supporting continued progress toward site cleanup and closure through remedy optimization and evaluation. ASM has the potential to expedite cleanup for the Central Plateau area at Hanford through a planned and systematic approach for reducing uncertainty with targeted characterization activities, while continuing remediation activities that advance cleanup for key risk-driving contaminants. A core component of cleanup within the Central Plateau is the 200 West Pump-and-Treat (P&T) system. Even with an active P&T remedy, uncertainty exists with respect to plume distributions, total mass in the aquifer, and currently known continuing sources. Additional uncertainty is associated with multiple contaminant source locations in the vadose zone, which have the potential to create new groundwater plumes in the absence of any source control measures, although not all contaminant fluxes to groundwater will result in contaminant concentrations above cleanup levels. Collectively, these uncertainties need to be addressed in the CSM to support effective and efficient site progress toward cleanup goal(s). Other nontechnical factors that may warrant an ASM approach at the Hanford Central Plateau are associated with the formation of operable units (OUs) used to manage cleanup. With the exception of the 200-ZP-1 OU, the three remaining groundwater OUs only have interim action records of decision. Nine vadose zone source area OUs are also in the early stages of the remedial investigation and feasibility study process, with pending characterization and technology identification activities. A set of proposed site objectives for the Central Plateau are provided in this document as an initial consideration/example and basis for discussion for ASM implementation. These example site objectives were selected with the goal of maintaining protectiveness at the Columbia River through confinement of contaminant plumes within an administratively controlled area below existing surface waste sites and waste disposal facilities. Although site decision makers and regulators need to provide concurrence, these site objectives are used in this document to describe the elements of an ASM approach, including selection of interim objectives and a long-term adaptive management plan. Interim objectives are also defined to yield measurable incremental progress toward the overall site goals. This document identifies initial technical considerations for developing an ASM framework for the Central Plateau cleanup decisions. These considerations are intended to facilitate more specific decisions, such as objectives, near- and long-term actions, and performance metrics, to develop an overall approach that maintains protectiveness but recognizes the uncertainty, long timeframe, and technical challenges that need to be considered in selecting, implementing, and managing remediation at the Hanford Central Plateau.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of a Null-Space Monte Carlo Flow Model Set to the Composite Analysis Base Case Fate and Transport Modeling

The Plateau-to-River (P2R) Model is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by Central Plateau Cleanup Company (CPCCo) at the Hanford Site in Washington State. Figure 1 illustrates the P2R Model extents, discretization, and boundary conditions. The P2R Model is utilized in the composite analysis (CA) for the Hanford Site as the computational engine for computing F&T predictions as described in CP-60406, Hanford Site Composite Analysis Technical Approach Description: Groundwater. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. CP-57037, Model Package Report for the Plateau to River Model Version 8.3 documents the current version of the P2R Model including a description of the conceptual site model, model development and calibration, and limitations to the model application.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predictive Contaminant Transport Simulation with the P2R Model for the Composite Analysis Inventory Sensitivity Case

The Plateau to River (P2R) Model is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by the Central Plateau Cleanup Company (CPCCo) at the Hanford Site in Washington State. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. The overall objective of the saturated zone modeling effort is to provide a basis for making informed remedial action decisions based on descriptions of current and expected future contaminant concentrations in groundwater at decision points within and downgradient of the Central Plateau of the Hanford Site. Specifically, the purpose of this environmental calculation file (ECF) is to describe an inventory sensitivity case of the CA base case. The inventory sensitivity case implements a change in the activity contribution from the vadose zone in the A Trenches Area model (for tritium (H-3) and iodine-129 (I-129)), BC Cribs and Trenches model (for I-129 and technetium-99 (Tc-99)), and the PUREX Area model (for H-3 and I-129). All other simulated inventories are identical to the CA base case. The simulation of F&T of contaminants reported in this case will support dose predictions as part of the Hanford Site CA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calculation of Groundwater Pathway Radiological Dose for the Hanford Site Composite Analysis Null-Space Model Carlo Flow Model Set

The purpose of this environmental calculation file (ECF) is to present the results of the exposure route-specific and total radiological dose assessments for the groundwater pathway based on the null space Monte Carlo (NSMC) groundwater concentrations as a part an uncertainty analysis for the updated Hanford Site Composite Analysis (CA). The Plateau-to River (P2R) Groundwater Model (CP-57037, Model Package Report: Plateau to River Groundwater Model Version 8.3) is the CA base case that simulates the fate and transport of radiological contaminants within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. An NSMC analysis was performed to identify and quantify the potential uncertainties associated with the P2R Model. The result of the NSMC analysis is a set of flow and transport simulations that provide an estimated range of possible outcomes that are used to quantify the uncertainty associated with the simulated base case concentrations.

54 ENVIRONMENTAL SCIENCES↗

Predictive Contaminant Transport Simulation with P2R Model for the Composite Analysis Limited Source Sensitivity Case.

The Plateau to River (P2R) is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by the Central Plateau Cleanup Company at the Hanford Site in Washington State. Figure 1 illustrates the P2R Model extents, discretization, and boundary conditions. The P2R Model is utilized in the Composite Analysis (CA) for the Hanford Site as the computational engine for computing F&T predictions as described in CP-60406, Hanford Site Composite Analysis Technical Approach Description: Groundwater. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. CP-57037, Model Package Report for the Plateau to River Model Version 8.3 documents the current version of the P2R Model including a description of the conceptual site model, model development and calibration, and limitations to the model application. Simulations conducted to support the dose calculations required by the CA are documented in ECF-HANFORD-19-0119, Predictive Flow Simulation with the P2R Model for the Composite Analysis Base Case and ECF-HANFORD-19-0120, Contaminant Transport Simulation with the P2R Model for the Composite Analysis Base Case.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mesofluidic Inline Separation for Produced Water Treatment: CRADA 537 [Abstract only]

The mesofluidic inline separation developed by PNNL represents an opportunity to remove a key barrier in the treatment of produced water: suspended solids that clog downstream operations to remove dissolved solids. The US alone produces over a trillion gallons of produced water each year, most of which is reinjected as a waste product. The impact from treating and reusing even a fraction of this water is immense as aquifers in the Midwest and elsewhere drying.

54 ENVIRONMENTAL SCIENCES↗

Dynamic Earth Energy Storage: Terawatt-year, Grid-scale Energy Storage Using Planet Earth as a Thermal Battery (GeoTES): Phase I Project (Final Report)

Grid-scale energy storage has been identified by the U.S. Department of Energy’s (DOE) Energy Storage Grand Challenge as a necessary technology to support the continued build-out of intermittent renewable energy resources required to attain a carbon-free energy future. To meet this goal, the 2018 Department of Energy Research and Innovation Act mandated the creation of a comprehensive program to accelerate the development and commercialization of next-generation energy storage technologies. One of numerous energy storage technology options is the storage of excess energy as heated geothermal brine in suitable geologic formations. This concept, known as reservoir thermal energy storage (RTES), geologic thermal energy storage (GeoTES), aquifer thermal energy storage (ATES), etc., relies on the storage of thermal energy in geologic formations for recovery and use in large-scale direct use geothermal (e.g., district heating, industrial processes, etc.) and electrical power generation applications. This thermal energy is derived from excess or waste heat from any high-temperature heat source, such as concentrated solar or from conventional thermal/nuclear generation. As such, RTES can potentially play a significant role in meeting the energy storage shortfall in the coming decades. RTES can provide energy arbitrage through both the storage and production of thermal energy stored in geologic formations for direct use applications and can serve as a source of hot fluids that can be used to generate electricity to support peak demand ramping, thus easing stress on transmission and distribution. This energy storage option has geographic benefits in that energy can be stored locally or regionally depending on the various needs/loads. RTES can also be located across an enormous geographic area, without the need for a traditional hydrothermal resource but where thermal gradients and hydrogeology allow economic exploitation of subsurface heat. The work conducted for this project includes (1) a review of lessons learned from past high-temperature RTES international projects; (2) geochemical experimental investigation and numerical simulations of potential domestic sedimentary reservoirs and (3) development of a thermo-hydrological-mechanical (THM) numerical simulation tool for optimizing formation properties and design parameters to maximize thermal energy storage performance.

15 GEOTHERMAL ENERGY↗

Separation of CO 2 from Flue Gas and Potential for Geologic Sequestration

The objectives of this study were to review various methods reported in the literature for the separation and geologic sequestration of carbon dioxide and evaluate the potential of TVA fossil fuel-burning plant locations for onsite geologic sequestration of CO 2 from stack emissions. Several conventional and nonconventional technologies for the separation of CO 2 from flue gas, including absorption, adsorption, cryogenic distillation, membranes, hydrate formation and dissociation, and ammonia carbonation, have been reviewed in terms of separation mechanisms, flow diagrams, and costs. Most of the technologies that have been reviewed are still at the research and development stage. Critical information needed to assess and compare these technologies is still lacking. In addition, information on some of the technologies that have been tested at a pilot or industrial scale has not been fully disclosed in the open literature. Because of this lack of data, it is difficult to make a critical assessment of each of the separation technologies. Based on limited information, it was concluded that the most promising methods are membrane separation and the Mitsubishi process for chemical absorption. Both processes involve separating CO 2 at high temperature, minimizing the cost for cooling prior to separation. Physical and chemical geologic formations of CO 2 were also reviewed. It was concluded that due to the geologic time scale of CO 2 sequestration periods, relatively safe conditions, general proximity to CO 2 sources, and extensive knowledge of underground conditions, sequestration of CO 2 in underground aquifers and coal beds is a very promising method of mitigating greenhouse gas emissions. The cost is predicted to be relatively low and the suitable sites are numerous for this application, with many of these sites located close to the plants.

20 FOSSIL-FUELED POWER PLANTS↗

Calendar Year 2020 Post-Closure Monitoring Report for Corrective Action Unit 99: Rainier Mesa/Shoshone Mountain, Underground Test Area, Nevada National Security Site, Nevada (Rev. 1)

This report presents the results of monitoring conducted for water quality, water levels, and institutional controls in calendar year (CY) 2020 by the U.S. Department of Energy (DOE), Environmental Management (EM) Nevada Program’s Underground Test Area (UGTA) Activity at Corrective Action Unit (CAU) 99, Rainier Mesa/Shoshone Mountain (RM/SM), at the Nevada National Security Site (NNSS), Nevada. This report also presents analytical laboratory results (including results of quality assurance/quality control samples, such as field duplicates [FDs]), and verification of use restrictions (URs), institutional controls, and water usage. Groundwater samples were collected; water levels were measured; and well site surveillance was conducted in support of the Underground Test Area Closure Report (CR) for Corrective Action Unit 99: Rainier Mesa/Shoshone Mountain, Nevada National Security Site, Nevada (DOE/EMNV, 2020). Rainier Mesa (RM) was the site of 61 underground nuclear tests, and Shoshone Mountain (SM) was the site of 6 underground nuclear tests. As a result of these activities, which took place from 1957 to 1992, radionuclides (RNs) were released in the subsurface in the vicinity of the detonations. These 67 underground nuclear tests are associated with 66 specific corrective action site (CAS) numbers, as listed in the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended). Two tests, HURON LANDING and DIAMOND ACE (conducted simultaneously), are included within one CAS. The CR (DOE/EMNV, 2020) establishes the regulatory boundaries and regulatory boundary objectives, monitoring program, UR boundaries and URs, and other institutional controls agreed to by EM Nevada Program and the Nevada Division of Environmental Protection (NDEP) for closure of CAU 99. Regulatory boundaries for the RM/SM CAU were established to protect receptors of groundwater from RN contamination within the three downgradient groundwater basins that receive recharge from RM. The SM regulatory boundary was established to verify that RN contamination does not reach the lower carbonate aquifer below SM. The UR boundaries were established based on contaminant simulation forecasts from the flow and transport simulations with consideration of site-specific topographical controls. The URs associated with the UR boundaries were identified to protect onsite workers and the public from inadvertent exposure to contaminated groundwater as forecasted to occur assuming current conditions. The UR is intended to restrict activities that might expose workers to contaminated groundwater within the UR area. In addition to the URs, other institutional controls are established to monitor and limit access to groundwater. These include federal ownership and management in perpetuity, controlled access of the NNSS and surrounding areas, and reporting water use on the NNSS and surrounding hydrographic basins.

54 ENVIRONMENTAL SCIENCES↗

Advances in 3D Geologic Modeling of Alluvial Basins with a Focus on Facies and Property Modeling

The unsaturated zone alluvium reference case is one of several geologic systems under consideration by the U.S. Department of Energy Office of Nuclear Energy for hosting repositories for spent nuclear fuel and associated waste (Sevougian et al., 2019). As noted by Mariner et al. (2018), the generic alluvial basin offers positive attributes that merit its consideration as a reference case by the Spent Fuel and Waste Science and Technology (SFWST) campaign. There are hundreds of alluvial basins and sub-basins scattered across the arid western United States (Figure 1-1). Precipitation and infiltration rates are relatively low with high evapotranspiration, resulting in vertical separation between repository and water table and thus longer transport paths to an aquifer. Accumulations of alluvial sediments within these basins are typically on the order of hundreds of meters, and locally may exceed 1,000 m in thickness, as is the case for the Deming sub-basin in southern New Mexico. A thick geologic host medium, which serves as the natural barrier system (NBS) in the conceptual model framework of a geologic disposal system, isolates the waste packages from receptors in the biosphere. Further, alluvial basin fill is typically comprised of stacked playa and lacustrine deposits along the basin axis (Perry et al., 2018). Characterized by low permeability, these layers protect the biosphere above the repository and the groundwater resources below the repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Incorporating Heterogeneity into 3D Geologic Models for the Alluvial Basin Reference Case

The unsaturated zone alluvium reference case is one of several geologic systems under consideration by the U.S. Department of Energy Office of Nuclear Energy for hosting repositories for spent nuclear fuel and associated waste (Sevougian et al., 2019). As noted by Mariner et al. (2018), the generic alluvial basin offers positive attributes that merit its consideration as a reference case by the Spent Fuel and Waste Science and Technology (SFWST) campaign. Hundreds of alluvial basins and sub-basins are scattered across the arid western United States (Figure 1-1). Precipitation and infiltration rates are relatively low with high evapotranspiration, resulting in deep regional water tables. Deep regional water tables allow for significant vertical separation between proposed repository depths and groundwater and thus longer transport paths from a hypothetical repository to an aquifer. Accumulations of alluvial sediments within these basins are typically on the order of hundreds of meters, and locally may exceed 1,000 m in thickness, as is the case for the Deming sub-basin in southern New Mexico. In alluvial basins, alluvium creates a thick geologic host medium that serves as the natural barrier system (NBS) in the conceptual model framework of a geologic disposal system and isolates the waste packages from receptors in the biosphere. Further, alluvial basin fill is typically comprised of stacked playa and lacustrine deposits along the basin axis (Perry et al., 2018). Characterized by low permeability, these layers protect the biosphere above the repository and the groundwater resources below the repository by limiting flow and transport of radionuclides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robust In-Situ Strain Measurements to Monitor CO 2 Storage

The goal of this project was to develop and demonstrate robust instrumentation to monitor the in-situ strain tensor in order to improve the reliability and security of CO 2 storage in geologic formations. We met the original goals of the project and the major overarching accomplishment is the advancement of strain tensor monitoring from an intriguing concept to a commercially available technology with a solid foundation of novel instruments supported by theoretical analyses and validation experiments. The main accomplishments of the project are summarized below. We designed, built and evaluated nine new optical fiber strainmeters and tiltmeters using Michelson interferometers to measure deformation with ultra-high resolution at both shallow and deep point locations in the subsurface. These are the robust strainmeters that motivated the title of the project. We designed, built and evaluated a novel method of measuring distributed strain in optical fibers with nanostrain resolution, and cm-scale location, and sampling into the seismic band. The new method is called Coherence-length-gated Microwave Photonics Interfereometry (CMPI). CMPI technology has advantages over existing commercial DAS and DSS methods. We developed and demonstrated capabilities to deploy instruments in the field and used them to measure strain caused by ambient signals like barometric pressure and tides, as well as induced signals like surface loading and pore pressure changes from pumping tests. We deployed a working strainmeter at 1,700 ft depth, slightly above an active reservoir. This is to our knowledge the greatest depth a strainmeter has been deployed and the techniques we used can readily be extended to greater depths. Optical fiber borehole tensor strainmeter techology was advanced from a TRL 4 at the start, to a TRL of 7 at the conclusion of the project. The project included advances in simulations and theoretical analyses. We developed and demonstrated a computational workflow that uses machine learning to reduce the computational requirements and make it practical to use Bayesian inversion to solve large numerical poroelastic analyses needed to interpret strain tensor field data. We evaluated the strain tensor fields and time series that would be caused by leaks of CO 2 or other fluids from reservoirs. These simulations demonstrated that signals from leaks could be measured with instruments developed for the project, opening a potentially new method for ensuring storage security. We showed that strains in caprock can be used to estimate pressure in a reservoir. This avoids the need to drill monitoring wells into the reservoir, and it expands the capabilities of monitoring in the caprock. The project includes a derivation and application of a novel analytical solution to the strains in the vicinity of a pressurized poroelastic inclusion. This solution explains field data measured during injeciton tests at the North Avant Field, and it will simplify future interpretation of strain tensor data. The project included a broad range of experiments, and of the most significant is the characterization of the strain tensor at an array three strainmeters during six injection tests at the North Avant Field, Oklahoma. This demonstrated repeatability of the strain signal measured by the new instruments developed for the project, and it showed similarities between the strain signal at shallow depths and pressure in the underlying reservoir. We also demonstrated that useful strain data can be measured at reservoir depths. This confirms that strain tensor data can be measured throughout the caprock over a reservoir. The project demonstrated the feasibility of using the strain tensor and distributed strain measured in caprock during a variety of different well tests where the pumping rate was constant, sinusoidal and positive, or a periodic square wave with zero net rate. This further strengthens the validity of using strain data to characterize reservoirs and aquifers. We also demonstrated that strain caused be fluctuations of air pressure and water pressure in the vadose zone can be measured and interpreted, suggesting that high resolution distributed strain measurements hold promise for monitoring the vadose zone. The project partially supported nine graduate students in the Environmental Engineering, Hydrogeology, Electrical Engineering programs at Clemson University. The research was described in nine journal papers, 23 talks and conference abstracts. Additional journal papers are in preparation. A new company called Tensora was started to provide strainmeter technology for commercial applications.

01 COAL, LIGNITE, AND PEAT↗

Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau (FY 2020) (Rev. 2)

This document provides an updated Hanford Site composite analysis (CA). A Hanford Site CA was prepared and issued in 1998 (PNNL-11800) with an addendum provided in 2002 (PNNL-11800 Addendum 1). The CA was approved in 2002 (Frei, 2002) and has been maintained (DOE/RL-2000-29 and subsequent revisions) to support low-level waste disposal performance assessments (PAs) and disposal authorizations for facilities at the Hanford Site, including the following: Continued operation of the Environmental Restoration Disposal Facility (ERDF) and the 200 East and 200 West Low-Level Burial Grounds; Construction of the Integrated Disposal Facility (IDF); Forthcoming closure of tank residual waste systems such as Waste Management Area (WMA) C. The CA maintenance program resulted in a determination in 2015 (DOE/RL-2015-66) that the Hanford Site CA needed an update for the following reasons: While the initial Hanford Site CA has been maintained since 2001, the accumulation of basis changes reported in the annual summary reports over the succeeding 14 years merit evaluation in an updated analysis; The U.S. Department of Energy (DOE) Headquarters requested in a memorandum in 2015 (Gilbertson and Marcinowski, 2015) that “as soon as the relevant PAs are complete, the CA will be revised to account for all of the new information.” This updated Hanford Site CA accounts for the following new information: 1. Inclusion of a detailed Hanford Site baseline disposition that projects remedial activities through site closure. There have been significant changes through decision making in the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) process that were not available when the original CA was produced; 2. Inclusion of an updated inventory basis, new modeling capabilities, and new decisions reached in the associated record of decision (ROD) that was provided by issuance of DOE/EIS-0391 in fiscal year (FY) 2013. Development of a Hanford Site groundwater model from the baseline provided in a technical transfer of models for the Final Tank Closure and Waste Management Environmental Impact Statement (DOE/EIS-0391) commenced in FY 2014 and resulted in the plateau-to-river (P2R) groundwater flow model that is used in this updated Hanford Site CA; 3. Accounting for pump and treat systems, which were not evaluated in the initial CA. Pump and treat systems have had significant impact on groundwater flow system behavior, contaminant transport, and contaminant removal from Hanford Site groundwater. This process is accounted for in the use of the P2R model for this updated Hanford Site CA; 4. Inclusion of water-level data collected since the initial CA was completed. Data collected as the unconfined aquifer water levels continue to recede since the cessation of large liquid discharges in the late 1990s have led to marked improvement in understanding of the flow system for future conditions, particularly regarding northward flow potential in the critical Gable Gap area. The calibration in the latest version of the P2R model accounts for this information; 5. Inclusion of results from the revised ERDF PA completed in 2013 (WCH-5209) that account for updated inventory and expansion of the ERDF facility to about twice the size that was evaluated in the original CA; 6. Use of updated geoframeworks to provide the structural basis for numerical fate and transport models in the groundwater pathway of this updated CA. The geologic basis for groundwater models has continued to improve with additional data collection and interpretation with the creation and maintenance of the Hanford South Geoframework and the Central Plateau Vadose Zone Geoframework tools; 7. Incorporation of updated tank residual inventory estimates. Tank residual inventory estimates have improved with the incorporation of tank retrieval inventory data for those tanks that have completed retrieval. The CA inventory data package includes this updated information; 8. Incorporation of WMA C PA results. Two additional PAs for tank farm closure decisions are in preparation during the period required to prepare an updated Hanford Site CA: WMA C (FY 2016) and WMA A-AX (in preparation). The WMA C PA results are incorporated into the updated Hanford Site CA, and its grouted residuals model is used as the basis for a release model to account for the other tank farm systems modeling in this updated CA; 9. An update to the IDF PA was submitted in FY 2017 and has been reviewed and approved. The results of the IDF PA are incorporated into this updated CA; 10. Updated risk assessment scenarios. The risk assessment scenarios currently in use for Hanford Site CERCLA and Resource Conservation and Recovery Act of 1976 (RCRA) analyses differ from those evaluated in the initial Hanford Site CA. The representative person exposure scenario evaluated in this updated Hanford Site CA is consistent with recent PAs and CERCLA and RCRA analyses as the Hanford Site. This updated Hanford Site CA provides the following: A comparison of the updated Hanford Site CA all-pathway dose results with the performance measures during the compliance period, which is assumed to begin with site closure in calendar 2070 with the last scheduled disposal action and continue for 1,000 years postclosure (to calendar year 3069); A comparison of Hanford Site CA all-pathway dose results with the performance measures during the postcompliance period to address potential peaks beyond the compliance period. This is accomplished by evaluating dose in the period for 9,000 years following the compliance period (i.e., from calendar year 3070 to 12070).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Local-Scale Framework for Techno-Economic Analysis of Subsurface Hydrogen Storage

The energy sector is evolving toward increased reliance on renewable energy technologies to meet state, national, and organization decarbonization goals. This trend is creating challenges and opportunities with meeting current and future energy demand under the variable supply conditions that most renewables provide. Hydrogen (H 2 ) is a promising energy carrier that may meet the need for both on-demand and long-duration storage to maintain energy security and resilience. Underground hydrogen storage (UHS) is a method of storing H 2 in subsurface geological systems, such as depleted hydrocarbon reservoirs, salt caverns, saline aquifers, hard rock, and other engineered systems. UHS has the potential to store large quantities of H 2 over time, providing a reliable source of energy while minimizing surface footprints at a lower investment cost compared to surface storage. Earlier work estimated that, if converted and retrofitted, existing underground natural gas storage (UGS) facilities in the U.S. can store approximately 327 TWh, or 9.8 million metric tons, of pure H 2 . However, a shift to pure H 2 would decrease the collective working-gas energy of the UGS facilities by approximately 75% due to physical and chemical differences between natural gas and hydrogen. The same work also suggests that almost 75% of the existing UGS facilities in the U.S. could maintain current energy demand buffering using a blend of only 20% H 2 to 80% natural gas, by volume at surface conditions. If we can take advantage of the suite of mature technologies of existing UGS facilities and natural gas utility systems to accelerate the transition to a hydrogen economy in the U.S., a 20% H 2 blend could lead to a 6-7% reduction of greenhouse gas emissions for energy delivered through natural gas utility systems.

03 NATURAL GAS↗