Effect of choked flow on terminal characteristics of MPD thrusters
A one-dimensional steady real gas MPD accelerator model based on data for various electrode lengths and anode orifice radii is presented. The model relates the electric field to the boundary conditions in a form that agrees with experiment over parametric variations in current and mass flow. The electric field is sensitive to the formulations and assumptions bound into the analysis, and is useful in the modeling of outflow properties. It is shown that the location of the sonic point in the arc chamber shifts upstream for high current operation, and the relation between terminal voltage and current is demonstrated. Experiments using an anode suggested by the theory yield a thrust efficiency 1.5 times that of the unmodified thruster.