Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analytical Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Analysis of Glycolate in Radioactive Waste by Ion Chromatography (IC) and Proton Nuclear Magnetic Resonance (H NMR)

Here, in preparation for implementing the Nitric-Glycolic (NG) acid flowsheet for the Savannah River Site (SRS) Liquid Waste System (LWS), analytical methods for determining glycolate at low concentration, below 20 mg/L in radioactive samples, were developed to support system management and safety. To accommodate the wide range of LWS matrix conditions, two alternative methods were developed, refined, and demonstrated for glycolate analysis in radioactive waste samples: ion chromatography (IC) and a proton nuclear magnetic resonance (H NMR). Investigators validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. The deployed IC method is applicable in low to moderate ionic strength samples and requires sample pretreatment using a Dionex OnGuard II H + cartridge. The deployed H NMR method is more labor intensive but provides options for a broader range of matrices. Based on the results, high quality glycolate analysis of the Defense Waste Processing Facility (DWPF) condensate in Tank 22 is feasible by IC down to approximately 12 mg/L. Using H NMR, glycolate may be determined to 8 mg/L or lower depending on the run time with the potential for broader applicability of the method to higher ionic strength conditions in other tanks of the SRS LWS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

BETO 2021 Peer Review - Analytical Development & Support WBS 2.5.1.101

The objective of the Analytical Development and Support (ADS) Project is to produce and maintain the critical analytical methods and tools that enable evaluation of emerging biofuels R&D at NREL and in the broader biofuels research community. Our project is divided into two tasks: one task to develop novel analytical techniques and improve existing methods and one task to maintain existing analytical capabilities at NREL and provide outreach to the wider community. The ADS Project is world-recognized for our Laboratory Analytical Procedures (LAPS) which provide detailed procedures for compositional analysis of biomass and have been adopted as the de facto standards within the biofuels community largely due to the transparency of the methods and the high reputation of NREL's research. Our dialog with stakeholders allows us to provide robust, precise, accurate, and publicly available analytical procedures for better valuation of scientific tools such as our recent accomplishment in developing a cellulose assay to support the EPA and industry in calculation of converted cellulose during starch ethanol production. We continue to develop analytical capabilities to support BETO's directives to research cost advantaged fuels such as animal wastes and novel bioproducts like 2,3-Butane-diol.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analytical workflow dependence of experimental observables for uranium chemistries

In this work, we investigated how the sequencing of laboratory analytical methods used for chemical and morphological characterization influences analytical findings for particulate materials relevant to the nuclear fuel cycle, including UO2, U3O8, studtite (UO2O2·4H2O), and β-UO3, in the context of nuclear forensic analysis. Particles of each chemistry obtained from consistent production batches were exposed to Raman spectroscopy and scanning electron microscopy in varying orders to elucidate how the order in which the techniques are applied influences morphological and chemical observations as a function of particle size. The results indicate that particles from all four chemistries exposed to high-resolution electron imaging before Raman spectral analysis demonstrate optical vibrational spectral changes that reduce accurate interpretation of the underlying chemistry via Raman spectral analysis. We hypothesize that these changes are due to the thermal load of the electron beam imparted to the sample being unable to be dissipated by materials with poor thermal conduction properties. Results from this study will aid in determining best practices for forensic analysis procedures to reduce uncertainty in chemical determination of unknown particulate samples.

Manns, Rebecca [University of Nevada, Las Vegas]↗

Development of a testing method for asbestos fibers in treated materials of asbestos containing wastes by transmission electron microscopy

Highlights: • A high sensitive and selective testing method for asbestos in treated materials of asbestos containing wastes was developed. • Asbestos can be determined at a limits are a few million fibers per gram and a few μg g{sup −1}. • High temperature melting treatment samples were determined by this method. Asbestos fiber concentration were below the quantitation limit in all samples, and total fiber concentrations were determined as 47–170 × 10{sup 6} g{sup −1}. - Abstract: Appropriate treatment of asbestos-containing wastes is a significant problem. In Japan, the inertization of asbestos-containing wastes based on new treatment processes approved by the Minister of the Environment is promoted. A highly sensitive method for testing asbestos fibers in inertized materials is required so that these processes can be approved. We developed a method in which fibers from milled treated materials are extracted in water by shaking, and are counted and identified by transmission electron microscopy. Evaluation of this method by using asbestos standards and simulated slag samples confirmed that the quantitation limits are a few million fibers per gram and a few μg/g in a sample of 50 mg per filter. We used this method to assay asbestos fibers in slag samples produced by high-temperature melting of asbestos-containing wastes. Fiber concentrations were below the quantitation limit in all samples, and total fiber concentrations were determined as 47–170 × 10{sup −6} f/g. Because the evaluation of treated materials by TEM is difficult owing to the limited amount of sample observable, this testing method should be used in conjunction with bulk analytical methods for sure evaluation of treated materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Making the Traffic Operations Case for Congestion Pricing: Operational Impacts of Congestion Pricing

Congestion begins when an excess of vehicles on a segment of roadway at a given time, resulting in speeds that are significantly slower than normal or 'free flow' speeds. Congestion often means stop-and-go traffic. The transition occurs when vehicle density (the number of vehicles per mile in a lane) exceeds a critical level. Once traffic enters a state of congestion, recovery or time to return to a free-flow state is lengthy; and during the recovery process, delay continues to accumulate. The breakdown in speed and flow greatly impedes the efficient operation of the freeway system, resulting in economic, mobility, environmental and safety problems. Freeways are designed to function as access-controlled highways characterized by uninterrupted traffic flow so references to freeway performance relate primarily to the quality of traffic flow or traffic conditions as experienced by users of the freeway. The maximum flow or capacity of a freeway segment is reached while traffic is moving freely. As a result, freeways are most productive when they carry capacity flows at 60 mph, whereas lower speeds impose freeway delay, resulting in bottlenecks. Bottlenecks may be caused by physical disruptions, such as a reduced number of lanes, a change in grade, or an on-ramp with a short merge lane. This type of bottleneck occurs on a predictable or 'recurrent' basis at the same time of day and same day of week. Recurrent congestion totals 45% of congestion and is primarily from bottlenecks (40%) as well as inadequate signal timing (5%). Nonrecurring bottlenecks result from crashes, work zone disruptions, adverse weather conditions, and special events that create surges in demand and that account for over 55% of experienced congestion. Figure 1.1 shows that nonrecurring congestion is composed of traffic incidents (25%), severe weather (15%), work zones, (10%), and special events (5%). Between 1995 and 2005, the average percentage change in increased peak traveler delay, based on hours spent in traffic in a year, grew by 22% as the national average of hours spent in delay grew from 36 hours to 44 hours. Peak delay per traveler grew one-third in medium-size urban areas over the 10 year period. The traffic engineering community has developed an arsenal of integrated tools to mitigate the impacts of congestion on freeway throughput and performance, including pricing of capacity to manage demand for travel. Congestion pricing is a strategy which dynamically matches demand with available capacity. A congestion price is a user fee equal to the added cost imposed on other travelers as a result of the last traveler's entry into the highway network. The concept is based on the idea that motorists should pay for the additional congestion they create when entering a congested road. The concept calls for fees to vary according to the level of congestion with the price mechanism applied to make travelers more fully aware of the congestion externality they impose on other travelers and the system itself. The operational rationales for the institution of pricing strategies are to improve the efficiency of operations in a corridor and/or to better manage congestion. To this end, the objectives of this project were to: (1) Better understand and quantify the impacts of congestion pricing strategies on traffic operations through the study of actual projects, and (2) Better understand and quantify the impacts of congestion pricing strategies on traffic operations through the use of modeling and other analytical methods. Specifically, the project was to identify credible analytical procedures that FHWA can use to quantify the impacts of various congestion pricing strategies on traffic flow (throughput) and congestion.

99 GENERAL AND MISCELLANEOUS↗

A strategy for analysis of thermal decomposition of polymeric materials

Some analytical methods developed in flammability research are reviewed. Computerized analytical systems are used to separate, identify, and quantify components of complex mixtures of low-boiling volatiles, high-boiling volatiles, and solid residues resulting from pyrolysis, oxidative degradation, and flaming combustion processes. To demonstrate the procedure for determining a material's response to a thermal flux administered under dynamic conditions, the treatment of data is reported for samples of an aromatic polyamide fabric which were degraded under isothermal conditions of 550 C following a dynamic heating rate of 100 C/min from ambient to final temperature.

Einhorn, I. N.↗

Design, ancillary testing, analysis and fabrication data for the advanced composite stabilizer for Boeing 737 aircraft. Volume 1: Technical summary

The horizontal stabilizer of the 737 transport was redesigned. Five shipsets were fabricated using composite materials. Weight reduction greater than the 20% goal was achieved. Parts and assemblies were readily produced on production-type tooling. Quality assurance methods were demonstrated. Repair methods were developed and demonstrated. Strength and stiffness analytical methods were substantiated by comparison with test results. Cost data was accumulated in a semiproduction environment. FAA certification was obtained.

Aniversario, R. B.↗

New Homogeneous Standards by Atomic Layer Deposition for Synchrotron X-ray Fluorescence and Absorption Spectroscopies.

Quantification of synchrotron XRF analyses is typically done through comparisons with measurements on the NIST SRM 1832/1833 thin film standards. Unfortunately, these standards are inhomogeneous on small scales at the tens of percent level. We are synthesizing new homogeneous multilayer standards using the Atomic Layer Deposition technique and characterizing them using multiple analytical methods, including ellipsometry, Rutherford Back Scattering at Evans Analytical, Synchrotron X-ray Fluorescence (SXRF) at Advanced Photon Source (APS) Beamline 13-ID, Synchrotron X-ray Absorption Spectroscopy (XAS) at Advanced Light Source (ALS) Beamlines 11.0.2 and 5.3.2.1 and by electron microscopy techniques. Our motivation for developing much-needed cross-calibration of synchrotron techniques is borne from coordinated analyses of particles captured in the aerogel of the NASA Stardust Interstellar Dust Collector (SIDC). The Stardust Interstellar Dust Preliminary Examination (ISPE) team have characterized three sub-nanogram, {approx}1{micro}m-sized fragments considered as candidates to be the first contemporary interstellar dust ever collected, based on their chemistries and trajectories. The candidates were analyzed in small wedges of aerogel in which they were extracted from the larger collector, using high sensitivity, high spatial resolution >3 keV synchrotron x-ray fluorescence spectroscopy (SXRF) and <2 keV synchrotron x-ray transmission microscopy (STXM) during Stardust ISPE. The ISPE synchrotron techniques have complementary capabilities. Hard X-ray SXRF is sensitive to sub-fg mass of elements Z {ge} 20 (calcium) and has a spatial resolution as low as 90nm. X-ray Diffraction data were collected simultaneously with SXRF data. Soft X-ray STXM at ALS beamline 11.0.2 can detect fg-mass of most elements, including cosmochemically important oxygen, magnesium, aluminum and silicon, which are invisible to SXRF in this application. ALS beamline 11.0.2 has spatial resolution better than 25 nm. Limiting factors for Stardust STXM analyses were self-imposed limits of photon dose due to radiation damage concerns, and significant attenuation of <1500 eV X-rays by {approx}80{micro}m thick, {approx}25 mg/cm{sup 3} density silica aerogel capture medium. In practice, the ISPE team characterized the major, light elements using STXM (O, Mg, Al, Si) and the heavier minor and trace elements using SXRF. The two data sets overlapped only with minor Fe and Ni ({approx}1% mass abundance), providing few quantitative cross-checks. New improved standards for cross calibration are essential for consortium-based analyses of Stardust interstellar and cometary particles, IDPs. Indeed, they have far reaching application across the whole synchrotron-based analytical community. We have synthesized three ALD multilayers simultaneously on silicon nitride membranes and silicon and characterized them using RBS (on Si), XRF (on Si{sub 3}N{sub 4}) and STXM/XAS (holey Si{sub 3}N{sub 4}). The systems we have started to work with are Al-Zn-Fe and Y-Mg-Er. We have found these ALD multi-layers to be uniform at {micro}m- to nm scales, and have found excellent consistency between four analytical techniques so far. The ALD films can also be used as a standard for e-beam instruments, eg., TEM EELS or EDX. After some early issues with the consistency of coatings to the back-side of the membrane windows, we are confident to be able to show multi-analytical agreement to within 10%. As the precision improves, we can use the new standards to verify or improve the tabulated cross-sections.

43 PARTICLE ACCELERATORS↗

Polyfluoroalkyl chemicals in house dust

We developed a high throughput analytical method using on-line solid phase extraction coupled with isotope dilution high-performance liquid chromatography-tandem mass spectrometry (on-line SPE-HPLC-MS/MS) to simultaneously determine the concentrations of 17 polyfluoroalkyl chemicals (PFCs) in house dust. The sample preparation includes dispersion of the dust samples in 0.1 M formic acid:MeOH (1:1), followed by agitation and filtration, addition of the isotope-labeled internal standard solution to the filtrate, and analysis by on-line SPE-HPLC-MS/MS. The limits of quantitation were <4.0 ng/g. The method accuracies ranged between 73.2% and 100.2% for the different analytes at two spike levels. We confirmed the validity of the method by analyzing 39 household dust samples collected in 2004. Of the 17 PFCs measured, 6 of them-perfluorobutane sulfonate (PFBuS), N-ethyl-perfluorooctane sulfonamide, 2-(N-ethyl-perfluorooctane sulfonamido) acetic acid (Et-PFOSA-AcOH), 2-(N-methyl-perfluorooctane sulfonamido) ethanol (Me-PFOSA-EtOH), perfluorohexane sulfonate (PFHxS), and perfluorooctane sulfonate (PFOS)-had detection frequencies >70%. We detected PFOS, PFBuS, and PFHxS at the highest median concentration, followed by Et-PFOSA-AcOH and Me-PFOSA-EtOH.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Some measurements of an EBF powered-lift wake

Results from a wind tunnel investigation in which velocity vector measurements were obtained in the near wake of an externally blown flap powered lift configuration were analyzed. These measurements were used to develop spanwise distributions for the momentum strength and location of the engine exhaust stream tube with the results used as input parameters to one jet flap analytical method. It is shown that a comparison of the momentum coefficients obtained from forward speed wake surveys with the predicted values from static force data results in a good correlation, which verifies the use of the flap thrust recovery factor as a means of predicting the momentum strength at the flap trailing edge. Also, when wake survey distributions of momentum strength and direction are used as input parameters to one analytical jet flap method, the results show reasonable agreement between the experimental data and analytical results.

Johnson, W. G., Jr.↗

INL CRMO XRF Special Report No. 3: INL CRMO XRF Calibration Methods for the Analysis of Ceramics and Brick

This report details the analytical methods used by the Idaho National Laboratory Cultural Resource Management Office to characterize ceramic and brick artifacts using X-ray fluorescence spectrometry. More specifically, this report provides details on instrumentation, analysis times, and matrix-specific calibration protocols for ceramic materials. Calibration curves were developed to adjust raw instrumental output for 13 elements using a suite of reference standards made from historic brick borrowed from the Yale Peabody Museum. Calibration curves were validated by plotting predicted values against published reference values for the calibration set as well as a certified soil reference standard (SRM 2711a).

36 MATERIALS SCIENCE↗

A method for correlating performance data of a terrestrial solar cell array

An analytical method was proposed for characterizing array power output, in the region of maximum power, as a function of environmental variables. The correlation provided a way of evaluating the output of an array under environmental conditions that differ from those encountered during testing. Power data obtained at one location was used to predict array performance at other locations.

Simon, F. F.↗

Advanced Method Optimization for Sampling and Analysis Instrumentation

This work presents a generalized approach for analytical method optimization that branches the gap between techniques historically employed and accurate modern optimization techniques suitable for various applications. The novelty of the described strategy is the utilization of multivariate, multiobjective optimization with Karush-Kuhn-Tucker conditions to bound the optimization space to solutions within the physical limitations of instrumentation. Briefly, the basic steps outlined in this paper are to (1) determine the objective(s) that should be maximized or minimized based on the goals of the analytical application, (2) conduct a screening experiment, (3) perform ANOVA to determine the parameters which have a statistically significant effect on the objective, (4) conduct an experiment (e.g., Box-Behnken design) to collect data for fitting the objective equation, and (5) determine the physical constraints of the parameters and solve the Lagrangian to determine the optimal method parameters. A broad approach to optimization target selection allows for robust method tuning to develop improved data sets amenable for chemometrics and machine learning algorithm development. Gas chromatography-mass spectrometry was selected as a use case due to its broad use across scientific fields and time-consuming method development involving numerous parameters. In conclusion, this strategy can reduce the cost of research, improve data quality, and enable the rapid development of new analytical technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quasi-single field inflation in the non-perturbative regime

In quasi-single field inflation there are massive fields that interact with the inflaton field. If these other fields are not much heavier than the Hubble constant during inflation ( H ) these interactions can lead to important consequences for the cosmological energy density perturbations. The simplest model of this type has a real scalar inflaton field that interacts with another real scalar S (with mass m). In this model there is a mixing term of the form μ ∙ π S , where π is the Goldstone fluctuation that is associated with the breaking of time translation invariance by the time evolution of the inflaton field during the inflationary era. In this paper we study this model in the region ( μ / H ) 2 + (m/ H ) 2 > 9/4 and m/ H ~O(1) or less. For a large part of the parameter space in this region standard perturbative methods are not applicable. In conclusion using numerical and analytic methods we study how large μ / H has to be for the large μ / H effective field theory approach to be applicable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Primary observables for indirect searches at colliders

We consider the complete set of observables for collider searches for indirect effects of new heavy physics. They consist of SU(3) C × U(1) EM invariant interaction terms/operators that parameterize deviations from the Standard Model. We show that, un der very general assumptions, the leading deviations from the Standard Model are given by a finite number of ‘primary’ operators, with the remaining operators given by ‘Mandelstam descendants’ whose effects are suppressed by powers of Mandelstam variables divided by the mass scale M of the heavy physics. We explicitly determine all 3 and 4-point primary operators relevant for Higgs signals at colliders by using the correspondence between on-shell amplitudes and independent operators. We give a detailed discussion of the methods used to obtain this result, including a new analytical method for determining the independent operators. The results are checked using the Hilbert series that counts independent operators. We also give a rough sketch of the phenomenology, including unitarity bounds on the interaction strengths and rough estimates of their importance for Higgs decays at the HL-LHC. These results motivate further exploration of Higgs decays to $Z\overline{f}f$, $W\overline{f}f'$, $γ\overline{f}f$, and $Zγγ$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗