Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analytical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Low-Frequency Magnetic Field Sensor Analytics

Narrowband and broadband low frequency magnetic field sensors have applications in EMI/EMC measurements and atmospheric and space research. This report gives analytical development of such sensors.

47 OTHER INSTRUMENTATION↗

Accelerated Aging of Fast Pyrolysis Bio-Oil Using Carbonyl Titration: Laboratory Analytical Procedure (LAP)

This laboratory analytical procedure covers the accelerated aging of fast pyrolysis bio-oils. Bio-oils undergo reactions that result in physical and chemical changes over time. These changes typically result in an increase in molecular weight, decrease in some functional groups such as carbonyls, and an increase in viscosity; additionally, the aging process often leads to phase separation. Studies have shown that accelerated aging of bio-oils using this method closely mimics room temperature aging for long periods of time (over 3 years). This procedure has been developed for the accelerated aging of fast pyrolysis bio-oils only. Fast pyrolysis bio-oils are more reactive than other bio-oils (e.g., catalytic fast pyrolysis) and undergo aging much more rapidly. Therefore, this procedure should only be used for fast pyrolysis bio-oil samples.

09 BIOMASS FUELS↗

Determination of Carbon, Hydrogen, Nitrogen, and Oxygen in Bio-Oils: Laboratory Analytical Procedure (LAP)

The determination of total carbon, hydrogen, and nitrogen in bio-oils is important as these values can be used to track the carbon balance of production processes as well as calculate total oxygen content by difference. Oxygen content of bio-oils is a key metric for production and upgrading strategies as these are typically aimed at reducing oxygen. Oxygenates in bio-oils contribute to poor hydrocarbon miscibility, high acidity, high viscosity, and poor stability. Upgrading of bio-oils via deoxygenation produces hydrocarbons which can be used to generate feedstocks for renewable fuels and chemicals. In this Laboratory Analytical Procedure (LAP), combustion-based ultimate analysis is used to determine the weight percent (wt%) of C, H, and N in bio-oils and upgraded products. Ultimate analysis uses high temperatures and a pure oxygen environment to completely combust organic samples to carbon dioxide (CO 2 ), water (H 2 O), and nitrogen oxides (NO x ). In this procedure the amount of C and H in the sample are quantified by measuring resultant CO 2 and H 2 O with Fourier-transform infrared spectroscopy (FTIR). For N, NO x is reduced to nitrogen (N 2 ) which is measured with a thermal conductivity detector (TCD), providing total N content.

09 BIOMASS FUELS↗

Determination of Water Content in Bio-Oils by Volumetric Karl Fischer Titration: Laboratory Analytical Procedure (LAP)

The water content of bio-oils is a key metric for several reasons. Water is typically the most concentrated single component of fast pyrolysis oils, though this will be much lower in catalytic fast pyrolysis and upgraded products. Reduced water content is preferable in bio-oil as water can contribute to phase separation, corrosivity, and instability. Additionally, lower water is beneficial for physical properties such as energy density. The percentage of water can also be used to correct the calculation for organic oxygen when determining total oxygen content of bio-oils via combustion-based ultimate analysis. The procedure described here is specifically written for the analysis of bio-oils, and is based on ASTM E203, Standard Test Method for Water Using Volumetric Karl Fischer Titration. This standard test method is specified for measuring the mass % water in pyrolysis liquid biofuels in ASTM D7544, Standard Specification for Pyrolysis Liquid Biofuel. Although the standard method is prescribed for the analysis of pyrolysis liquids for use in industrial and commercial burners, the method is not specifically written for this product. The method described with this Laboratory Analytical Procedure (LAP) provides specific guidance for the analysis of bio-oils. Both organic and aqueous phases can be measured with this technique.

09 BIOMASS FUELS↗

Determination of Carbon Functional Groups in Pyrolysis Bio-Oils using 13 C NMR: Laboratory Analytical Procedure (LAP)

Pyrolysis is a process that can be used to convert biomass to solid, liquid and gaseous products for use as renewable chemicals and fuels. The liquid fraction, known as “bio-oil” is complex and challenging to characterize, particularly by means of GC/MS, GPC, LC and FT-IR. NMR is capable of analyzing whole bio-oil samples and can provide quantitative results to characterize different functional groups or types of carbon present in bio-oil. This Laboratory Analytical Procedure (LAP) quantifies different carbon functional groups in whole bio-oil samples. This information can be used for comparisons between different pyrolysis experimental conditions or different upgrading processes and catalysts, and also allow for comparisons between bio-oils produced at different facilities.

09 BIOMASS FUELS↗

Lessons Learned-Analytical Laboratory Construction Modifications

The purpose of this document is to disseminate lessons learned from the Sandia National Laboratories (SNL) Building 1090 modification project and other analytical laboratory related construction projects. The following sections summarize lessons learned at various phases of the project.

99 GENERAL AND MISCELLANEOUS↗

Deliberate Motion Analytics Fused Radar and Video Test Results Deployed Beyond the Perimeter Fence in a High Noise Environment

Security systems that protect the nation’s critical facilities must be capable of detecting physical intrusions in all weather conditions. Intrusion detection sensors in a perimeter with a high nuisance alarm rate (NAR) significantly undermine detection performance and degrade security system effectiveness. This research demonstrated a fused sensor system that can differentiate foliage and weather-induced nuisance alarms from those caused by intruders, providing reliable detection within a two-fence perimeter or beyond the fence. A key element of this work is the creation and application of a “deliberate motion algorithm” that fuses alarm data from radar and video analytics to create video motion detection fused radar system. The two-layer architecture of the algorithm uses machine learning, multi-hypothesis tracking, and Dynamic Bayes Nets to differentiate intruder alarms from weather induced alarms.

47 OTHER INSTRUMENTATION↗

A Robust Event Diagnostics Platform: Integrating Tensor Analytics and Machine Learning into Real-time Grid Monitoring

The objective of this project is to develop a robust event diagnostics (RED) platform by integrating state-of-the-art tensor analytics and machine learning into real-time grid monitoring. The proposed platform can effectively analyze and discover the information hiding within the provided PMU data for effective real-time grid monitoring. The proposed RED platform provides a set of robust diagnostics tools for grid operation and management, including 1) data quality assessment, 2) data completion, 3) event detection, and 4) robust event classification. All the functionalities of the RED platform can help the operator to make informed decisions and respond in a timely manner. The developed RED platform will serve as an innovative advisory tool to reliably identify key events and discover new insights about the events and grid characteristics in the PMU data, and contribute to the efficient, safe, reliable operation and design of the nation’s electric system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Corrosivity Screening of Pyrolysis Bio-Oils by Short-Term Alloy Exposures. Laboratory Analytical Procedure (LAP), Issue Date: May 12, 2022

Bio-oils contain organic acids and oxygenated compounds that can lead to corrosion issues during bio-oil processing and storage. This Laboratory Analytical Procedure (LAP) allows for rapid screening of a bio-oil's corrosivity without the need for complex equipment and long-term exposures. A robust and repeatable method for assessing the corrosivity of bio-oils is necessary in order to remove materials degradation as an obstacle to research, upgrading, use and storage of bio-oils. This LAP involves the incubation of a representative alloy, 410 stainless steel (410 SS), specimen in bio-oil over a period of 48 hours at 50 degrees C in a sealed container. The corrosive species in the bio-oil react with and deplete alloy elements such as iron (Fe) and/or chromium (Cr) from the specimen into the bio-oil solution. The depletion of Fe and Cr from the specimen results in a significant mass loss that can be recorded. The mass loss is directly correlated to the corrosivity of a bio-oil. Examples of bio-oils in scope include the ones produced by fast pyrolysis and catalytic fast pyrolysis, as well as liquids produced from hydrothermal liquefaction.

09 BIOMASS FUELS↗

Determination of Phenolic Groups in Bio-Oils Using Revised Folin-Ciocalteu Methods: Single Cuvette and Plate Reader. Laboratory Analytical Procedure (LAP), Issue Date: May 12, 2022

Phenol components are ubiquitous in wood-derived bio-oils and biocrudes. Their reaction with other functional groups (e.g., aldehydes) may contribute to the formation of carbonaceous species and the expected thermal instability of pyrolysis oils. During hydrotreating, phenols can be recalcitrant species, requiring higher reaction temperatures than other oxygen-containing functional groups. Phenols are also present in upgraded products and have been shown to lead to catalyst deactivation during hydrotreating. They also are the first oxygenated functional group to re-appear in the upgraded product, signaling catalyst deactivation. This procedure covers the determination of phenolic compounds in fast pyrolysis oils. This Laboratory Analytical Procedure (LAP) includes two methods, the first allowing for shorter analysis time at increased reaction temperature, while the second employs a longer analysis time but at room temperature. Additionally, the use of both a single cuvette and of a plate reader are also presented.

09 BIOMASS FUELS↗

Elemental Analysis of Bio-Oils by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). Laboratory Analytical Procedure (LAP), Issue Date: May 13, 2022

Concentrations of inorganic elements is a key quality metric for bio-oils as certain elements impact upgrading processes and product quality. Unless reduced or removed during production and processing, alkali and alkaline metals native to lignocellulosic biomass can carry over into bio-oils contributing to ash content and degraded catalyst performance during upgrading to hydrocarbon fuels or chemical products. Non-metallic elements such as sulfur and phosphorus can also negatively impact upgrading catalysts and product quality. Inductively coupled plasma optical emission spectroscopy (ICP-OES) can be used to measure inorganic elements of interest in bio-oils. This procedure covers the preparation and analysis of fast pyrolysis (FP) and catalytic fast pyrolysis (CFP) bio-oils. The concentrations of these elements can indicate potential bio-oil quality from the perspective of deoxygenation processes. The implications of elemental composition will depend on process parameters such as upgrading catalyst sensitivities. This Laboratory Analytical Procedure (LAP) covers two methods for quantification of inorganic elements by ICP-OES: Procedure A uses microwave assisted digestion with concentrated nitric acid, and Procedure B is an organic ICP-OES method utilizing a diglyme solvent.

09 BIOMASS FUELS↗

Performance Testing of Software Upgrade for SRNL CPC Instrument at the Nuclear Material Laboratory, Office of Safeguards Analytical Services, International Atomic Energy Agency

This report summarizes the performance testing for the Software upgrade for the Savannah River National Laboratory (SRNL) Controlled Potential Coulometry (CPC) instrument. This upgrade is specifically to meet the needs of the Nuclear Material Laboratory, Office of Safeguards Analytical Services, International Atomic Energy Agency at Seibersdorf, Austria. The instrument hardware was upgraded in 2010, but the software continued to operate on a Windows platform using a High Tech Basic (HT Basic) application. HT Basic usage is declining. The IAEA requested an upgrade to the existing coulometer software to Laboratory Virtual Instrument Engineering Workbench (LabVIEW), an object-oriented programming language in wide use and one the NML staff is familiar with. The software was developed by SRNL Software Engineer, with assistance from Electrical Engineer and Scientist. Once developed, the new LabVIEW software was validated, tested with Iron (surrogate for plutonium) and plutonium. Once testing was completed, the software was installed at the International Atomic Energy Agency Nuclear Material Laboratory (IAEA NML) coulometer, and SRNL provided hands on training to NML staff on using the new software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operational Technology Behavioral Analytics (OTBA) (Final Technical Report DE-FE0031640)

This final report provides a summary of the methodology, findings, lessons learned, and insights from an investigation into the feasibility of the Operational Technology Behavioral Analytics (OTBA) cybersecurity approach. The concept was evaluated with data from the National Carbon Capture Center (NCCC) – a U.S. Department of Energy (DOE) funded facility that is managed and operated by Southern Company Services, Inc. at Alabama Power Company’s E. C. Gaston generating power plant in Wilsonville, Alabama. Appropriate data sources for the post-combustion carbon capture system were identified. Infrastructure was deployed to monitor, capture and archive data for the system. Critical parameters for each subsystem were identified and analyzed. Machine-learning algorithms were used to establish and characterize normal operations and subsequently identify anomalies. This effort yielded valuable insights and formed the basis of a data-centric strategy for detecting cyber-attacks along with a coordinated response philosophy. A significant takeaway is that the OTBA cybersecurity approach is quite portable; it can be applied to other critical infrastructure beyond fossil power generation.

20 FOSSIL-FUELED POWER PLANTS↗

Predictive Data Analytics Framework Using Advanced Test Reactor Acoustic Data

Although a nuclear reactor is a hostile environment for sensing and electrical communications, the reactor core is amenable to acoustic communication. An acoustic measurement infrastructure (AMI) has been installed at the Advanced Test Reactor (ATR) nozzle trench area to record acoustic signals that has the ability to capture different operating regime of the reactor. This AMI includes ATR in-pile structural components, coolant, acoustic receivers, primary coolant pumps (PCP) as signal sources, a data acquisition system, and signal-processing algorithms, enabling real-time. This report will discusses development of recursive Fast Fourier Transform approach to process in real-time acoustic signals, application of short time Fast Fourier Transform to the ATR brush data to understand the vibration level and to develop spectrograms for different primary coolant pump combinations. The combination of primary coolant pumps for normal and power axial locator mechanism of ATR are different and generates different signatures. These acoustic signatures were used to develop machine learning approaches to automatically classify different operating regimes. This lay the foundation for predictive analytic framework that can be leverage by ATR to optimize their operation and maintenance. The path forward involves continued engagement with ATR and expanded implementation of AMI and predictive framework at ATR and other facilities within INL and at other experimental reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary of Analytical Services for the Hanford Site Radionuclide NESHAP Program

This document serves as a summary of the analytical requirements used to demonstrate compliance on the Department of Energy (DOE) Hanford Site to 40 CFR 61, “National Emission Standards for Hazardous Air Pollutants,” (NESHAP) Subpart H, “National Emission Standards for Emissions of Radionuclides Other Than Radon From Department of Energy Facilities,” and WAC 246-247, “Radiation Protection – Air Emissions.” This document is a reference summarizing information from multiple existing requirement source documents and does not create, supersede, replace or over-ride any existing contractual, DOE, federal, state, permit or license requirement. The requirement source documents govern where any differences may exist.

54 ENVIRONMENTAL SCIENCES↗

Applying novel analytical tools for analyzing multidimensional secondary organic aerosol measurements

In the atmosphere, secondary organic aerosols (SOA) are often the major components of fine particulate matter and interact with clouds and radiation. SOA comprises a mixture of thousands of organic compounds. There is tremendous complexity and uncertainty in understanding SOA formation, since it is formed by oxidation and gas to particle conversion of a variety of sources: natural biogenic, anthropogenic (vehicles, cooking coal combustion) and biomass burning. The Aerosol Mass Spectrometer (AMS) produces multidimensional chemical information about SOA but analyzing this data to understand SOA sources relies on time consuming analyses (~months to years) such as the positive matrix factorization (PMF). PMF also becomes difficult for aircraft data where signal to noise ratio is weaker. There is a critical need to develop fast machine learning techniques that can analytically provide information about SOA sources using AMS data on the same timescales as the data is being collected (~minutes). We apply a machine learning supervised classification approach: the multinomial logistic regression to rapidly classify AMS data obtained from aircraft measurements.

47 OTHER INSTRUMENTATION↗