Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ambient Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Seismic Data Acquisition at the FACT Site for the CASPAR Project

Since May 2010, we have been recording continuous seismic data at Sandia's FACT site. The collected signals provide us with a realistic archive for testing algorithms under development for local monitoring of explosive testing. Numerous small explosive tests are routinely conducted around Kirtland AFB by different organizations. Our goal is to identify effective methods for distinguishing these events from normal daily activity on and near the base, such as vehicles, aircraft, and storms. In this report, we describe the recording system, and present some observations of the varying ambient noise conditions at FACT. We present examples of various common, non-explosive, sources. Next we show signals from several small explosions, and discuss their characteristic features.

58 GEOSCIENCES↗

Retrospective on decadal progress of the NOAA/NPS ocean noise reference station network

The National Oceanic and Atmospheric Administration (NOAA), in partnership with the U.S. National Park Service (NPS), established the Ocean Noise Reference Station Network (NRS) in 2014 as a foundational component of NOAA’s Ocean Noise Strategy. This long-term effort aims to characterize baseline ocean ambient sound conditions across diverse marine environments and to inform management of noise impacts on protected species and habitats within U.S. waters. The NRS is now composed of 13 autonomous passive acoustic monitoring stations strategically positioned across the U.S. Exclusive Economic Zone (EEZ), extending from Arctic regions to tropical waters in depths ranging from 33 to 4,790 m. These locations include several National Marine Sanctuaries and National Parks, such as the recently designated Chumash Heritage National Marine Sanctuary off the coast of California. Each station is equipped to continuously sample low-frequency underwater sound at five kHz, enabling the detection of anthropogenic, geophysical, and biological acoustic signals. To date the network has sampled over 72 years of calibrated acoustic data. The spatial breadth and consistent methodology of the NRS allow for comparative acoustic assessments across diverse marine ecosystems. In addition to applied research functions, the NRS has served as a platform for education and training, offering opportunities for students to develop skills for marine science and data analysis. Looking forward, the NRS project team is focused on network expansion, improved data delivery, and broader integration with collaborative scientific initiatives. NRS recordings are being archived in partnership with NOAA’s National Centers for Environmental Information to enhance accessibility and long-term utility. Efforts are underway to develop standardized metadata and summary products to accompany raw audio files, making the data more usable for a wide range of stakeholders in the ocean science community. The NRS is evolving into a fully integrated national framework for ocean sound monitoring that supports scientific inquiry, management decision-making, national security interests, and public engagement with ocean acoustic environments.

Long-term monitoring↗

In situ magnetic field observations of the AMPTE artificial comet

Magnetometers aboard the IRM and UKS spacecraft monitored the magnetic field during the AMPTE artificial comet experiment of Dec. 27, 1984. Rapid photoionization of the released barium vapor resulted in the formation of a magnetic cavity, shielded from the ambient magnetic field.The presence of this highly conductive obstacle caused draping and compression of the solar wind magnetic field.

Luehr, H.↗

Hourly land-use regression models based on low-cost PM monitor data

Highlights: • A network of 23 low-cost PM monitors was deployed across an urban area. • Land use regression models predict the hourly intra-urban PM variations. • Coefficients of determination for hourly PM predictions ranged 0.66–0.76. • Low-cost PM monitor data need to be carefully evaluated before use. • The combination of low-cost monitors and modeling provides useful PM estimates. Land-use regression (LUR) models provide location and time specific estimates of exposure to air pollution and thereby improve the sensitivity of health effects models. However, they require pollutant concentrations at multiple locations along with land-use variables. Often, monitoring is performed over short durations using mobile monitoring with research-grade instruments. Low-cost PM monitors provide an alternative approach that increases the spatial and temporal resolution of the air quality data. LUR models were developed to predict hourly PM concentrations across a metropolitan area using PM concentrations measured simultaneously at multiple locations with low-cost monitors. Monitors were placed at 23 sites during the 2015/16 heating season. Monitors were externally calibrated using co-located measurements including a reference instrument (GRIMM particle spectrometer). LUR models for each hour of the day and weekdays/weekend days were developed using the deletion/substitution/addition algorithm. Coefficients of determination for hourly PM predictions ranged from 0.66 and 0.76 (average 0.7). The hourly-resolved LUR model results will be used in epidemiological studies to examine if and how quickly, increases in ambient PM concentrations trigger adverse health events by reducing the exposure misclassification that arises from using less time resolved exposure estimates.

54 ENVIRONMENTAL SCIENCES↗

Wireless energy transmission to supplement energy harvesters in sensor network applications

In this paper we present a method for coupling wireless energy transmission with traditional energy harvesting techniques in order to power sensor nodes for structural health monitoring applications. The goal of this study is to develop a system that can be permanently embedded within civil structures without the need for on-board power sources. Wireless energy transmission is included to supplement energy harvesting techniques that rely on ambient or environmental, energy sources. This approach combines several transducer types that harvest ambient energy with wireless transmission sources, providing a robust solution that does not rely on a single energy source. Experimental results from laboratory and field experiments are presented to address duty cycle limitations of conventional energy harvesting techniques, and the advantages gained by incorporating a wireless energy transmission subsystem. Methods of increasing the efficiency, energy storage medium, target applications and the integrated use of energy harvesting sources with wireless energy transmission will be discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Miniature Piezoelectric Shaker Mechanism for Autonomous Distribution of Unconsolidated Sample to Instrument Cells

To perform in-situ measurements on Mars or other planetary bodies many instruments require powder produced using some sampling technique (drilling/coring) or sample processing technique (core crushing) to be placed in measurement cells. This usually requires filling a small sample cell using an inlet funnel. In order to minimize cross contamination with future samples and ensure the sample is transferred from the funnel to the test cell with minimal residual powder the funnel is shaken. The shaking assists gravity by fluidizing the powder and restoring flow of the material. In order to counter cross contamination or potential clogging due to settling during autonomous handling a piezoelectric shaking mechanism was designed for the deposition of sample fines in instrument inlet funnels. This device was designed to be lightweight, consume low power and demonstrated to be a resilient solid state actuator that can be mechanically and electrically tuned to shake the inlet funnel. In the final design configuration tested under nominal Mars Ambient conditions the funnel mechanism is driven by three symmetrically mounted piezoelectric flexure actuators that are out of the funnel support load path. The frequency of the actuation can be electrically controlled and monitored and mechanically tuned by the addition of tuning mass on the free end of the actuator. Unlike conventional electromagnetic motors these devices are solid state and can be designed with no macroscopically moving parts. This paper will discuss the design and testing results of these shaking mechanisms.

powder movement↗

Oil-immersed transformer thermal monitoring and prediction system

A real time thermal monitoring and prediction system (TMPS) is provided for use in monitoring and operating a transformer. The TMPS may be used to estimate a maximum loading level for the transformer over a future time period using a dynamic thermal model for the transformer and ambient temperature forecasts. The transformer may be loaded to its maximum loading level during power congestion or a service restoration process.

Feng, Xianyong↗

Study of Plastic Scintillator Properties for Radioactive Sources Dosimetry - Paper 108

Plastic scintillator is a simple material which has the density close to that of human soft tissue (1.06 g/cm{sup 3}). Its energy response is close to that of human soft tissue and it is relatively energy independent. This prospect provide a desired characteristics in measuring dose by plastic scintillator either for radiation monitoring or personal dosimeter. Generally the energy calibration of organic scintillator will be done by using gamma ray sources. The positions of Compton edge in pulse height spectra, which have known energy values will be identified. However the Compton edge normally is very broad and difficult to determine the point corresponding to that particular Compton electron energies. Many researchers used several fitting functions and Monte Carlo simulations to determine the position of Compton edge. For example, Proctor and Wellman (2012) used a straight line fit to the linear part of Compton edge and extrapolated to zero count. While L. Swiderski et al. used a method based on a back-scattered coincidence measurement to measure in a wide energy range the position of Compton edge in organic scintillators. For a simple and quick approach of calibration, we used a Gauss-error function to fit the Compton edge region of interest by assumed that the location of maximum energy of Compton electrons is half-height of the Compton maximum (CM). The reasons is because the CM position could be determined easily from the spectra throughout wide energy range. Interpreting gamma dose rates from accumulated plastic scintillation detector spectra is often a complex task because the probability of a full energy deposition event in the detector is often negligible. Despite no full energy peaks in plastic scintillator spectra, several attempts have been made by the other researchers to obtain the dose from the energy distribution spectra of gamma radiation. For example, Proctor and Wellman used the modified spectrum dose index (SDI) to calculate the exposure rates by multiplying the energy corresponding to its channel and all products are summed before multiply by a calibration constant to yield an exposure rate. While Lobdell and Hertel calculated dose using a response matrix based on spectral unfolding technique. From these points of view, we have made an attempt to correlate the counts obtained in scintillator with absorbed dose or ambient dose equivalent. We aimed to calibrate the plastic scintillator energy deposition for dose, by correlate the counts obtained with a particular value of dose. By designed the scintillator to measure at 1 cm tissue depth might be helpful to be used as radiation monitoring or personal dosimeter since the energy response of plastic scintillator is relatively energy independent compared to that of inorganic scintillators. The energy calibration proposed from simple fitting approach had been verified with calculated spectra. This might be considered as a practical approach for technician or radiation workers with sufficient accuracy. The linear behavior of counts per absorbed dose give promising to calibrate scintillator energy deposition to read dose (equivalent dose or absorbed dose) for photons. Thus the scintillator could provide both the energy and dose response simultaneously, which may important in some radiation field of measurements. Currently the scintillator is able to give dose rate value for gamma sources of Cs-137 and Mn-54. The number of counts per unit absorbed dose would likely to vary somewhat with photon energy, although the plastic scintillator should have a tissue dose response that is relatively energy independent. Further analysis will be done on conversion factor parameters so that it could be used in such situations where the radiation field is complex or unknown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-term exposure to ambient air pollution (including PM1) and metabolic syndrome: The 33 Communities Chinese Health Study (33CCHS)

Highlights: • Associations of ambient air pollution with metabolic syndrome were scarcely studied. • Data from 15,477 Chinese adults were analyzed. • Long-term exposure to air pollution was associated with metabolic syndrome. • Demographic and lifestyle factors modified the association between metabolic syndrome and air pollution. Little evidence exists about the effects of long-term exposure to ambient air pollution on metabolic syndrome (MetS). This study aimed to determine the association between long-term ambient air pollution and MetS in China. A total of 15,477 adults who participated in the 33 Communities Chinese Health Study (33CCHS) in 2009 were evaluated. MetS was defined based on the recommendation by the Joint Interim Societies. Exposure to air pollutants was assessed using data from monitoring stations and a spatial statistical model (including particles with diameters ≤ 1.0 µm (PM{sub 1}), ≤ 2.5 µm (PM{sub 2.5}), and ≤ 10 µm (PM{sub 10}), sulfur dioxide (SO{sub 2}), nitrogen dioxide (NO{sub 2}), and ozone (O{sub 3})). Two-level logistic regression analyses were utilized to assess the associations between air pollutants and MetS. The prevalence of MetS was 30.37%. The adjusted odds ratio of MetS per 10 µg/m{sup 3} increase in PM{sub 1}, PM{sub 2.5}, PM{sub 10}, SO{sub 2}, NO{sub 2}, and O{sub 3} were 1.12 (95% CI = 1.00–1.24), 1.09 (95% CI = 1.00–1.18), 1.13 (95% CI = 1.08–1.19), 1.10 (95% CI = 1.02–1.18), 1.33 (95% CI = 1.12–1.57), and 1.10 (95% CI = 1.01–1.18), respectively. Stratified analyses indicated that the above associations were stronger in participants with the demographic variables of males, < 50 years of age, and higher income, as well as with the behavioral characteristics of smoking, drinking, and consuming sugar-sweetened soft drinks frequently. This study indicates that long-term exposure to ambient air pollutants may increase the risk of MetS, especially among males, the young to middle aged, those of low income, and those with unhealthy lifestyles.

54 ENVIRONMENTAL SCIENCES↗

Mitigation of methane emission from Fakse landfill using a biowindow system

Landfills are significant sources of atmospheric methane (CH{sub 4}) that contributes to climate change, and therefore there is a need to reduce CH{sub 4} emissions from landfills. A promising cost efficient technology is to integrate compost into landfill covers (so-called 'biocovers') to enhance biological oxidation of CH{sub 4}. A full scale biocover system to reduce CH{sub 4} emissions was installed at Fakse landfill, Denmark using composted yard waste as active material supporting CH{sub 4} oxidation. Ten biowindows with a total area of 5000 m{sup 2} were integrated into the existing cover at the 12 ha site. To increase CH{sub 4} load to the biowindows, leachate wells were capped, and clay was added to slopes at the site. Point measurements using flux chambers suggested in most cases that almost all CH{sub 4} was oxidized, but more detailed studies on emissions from the site after installation of the biocover as well as measurements of total CH{sub 4} emissions showed that a significant portion of the emission quantified in the baseline study continued unabated from the site. Total emission measurements suggested a reduction in CH{sub 4} emission of approximately 28% at the end of the one year monitoring period. This was supported by analysis of stable carbon isotopes which showed an increase in oxidation efficiency from 16% to 41%. The project documented that integrating approaches such a whole landfill emission measurements using tracer techniques or stable carbon isotope measurements of ambient air samples are needed to document CH{sub 4} mitigation efficiencies of biocover systems. The study also revealed that there still exist several challenges to better optimize the functionality. The most important challenges are to control gas flow and evenly distribute the gas into the biocovers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Compliant alkali silicate sealing glass for solid oxide fuel cell applications: thermal cycle stability and chemical compatibility

An alkali silicate glass (SCN-1) is currently being evaluated as a candidate sealing glass for solid oxide fuel (SOFC) applications. The glass containing ~17 mole% alkalis (K2O and Na2O) remains vitreous and compliant during SOFC operation, unlike conventional SOFC sealing glasses, which experience substantial devitrification after the sealing process. The non-crystallizing compliant sealing glass has lower glass transition and softening temperatures since the microstructure remains glassy without significant crystallite formation, and hence can relieve or reduce residual stresses and also has the potential for crack healing. Sealing approaches based on compliant glass will also need to satisfy all the mechanical, thermal, chemical, physical, and electrical requirements for SOFC applications, not only in bulk properties but also at sealing interfaces. In this first of a series of papers we will report the thermal cycle stability of the glass when sealed between two SOFC components, i.e., a NiO/YSZ anode supported YSZ bilayer and a coated ferritic stainless steel interconnect material. High temperature leak rates were monitored versus thermal cycles between 700-850oC using back pressures ranging from 0.2 psi to 1.0 psi. Isothermal stability was also evaluated in a dual environment consisting of flowing dilute H2 fuel versus ambient air. In addition, chemical compatibility at the alumina and YSZ interfaces was examined with scanning electron microscopy and energy dispersive spectroscopy. The results shed new light on the topic of SOFC glass seal development.

30 DIRECT ENERGY CONVERSION↗

Endogenous thermoregulatory rhythms of squirrel monkeys in thermoneutrality and cold

Whole body heat production (HP) and heat loss (HL) were examined to determine if the free-running circadian rhythm in body temperature (Tb) results from coordinated changes in HP and HL rhythms in thermoneutrality (27 degrees C) as well as mild cold (17 degrees C). Squirrel monkey metabolism (n = 6) was monitored by both indirect and direct calorimetry, with telemetered measurement of Tb and activity. Feeding was also measured. Rhythms of HP, HL, and conductance were tightly coupled with the circadian Tb rhythm at both ambient temperatures (TA). At 17 degrees C, increased HP compensated for higher HL at all phases of the Tb rhythm, resulting in only minor changes to Tb. Parallel compensatory changes of HP and HL were seen at all rhythm phases at both TA. Similar time courses of Tb, HP, and HL in their respective rhythms and the relative stability of Tb during both active and rest periods suggest action of the circadian timing system on Tb set point.

NASA Discipline Regulatory Physiology↗

Xenon Detection Using Double-Pulse Laser-Induced Breakdown Spectroscopy

Laser-induced breakdown spectroscopy has been proposed as a diagnostic tool for fuel failure monitoring in helium-cooled fast reactor designs. Here, we show preliminary results which indicate that using double-pulse laser induced breakdown spectroscopy, a sub-ppm sensitivity for xenon in a helium ambient can be achieved. We additionally propose future studies which could help elucidate the mechanisms which lead to the observed signal enhancement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Direct Observation of Morphological and Chemical Changes during the Oxidation of Model Inorganic Ligand-Capped Particles

Functionalization and volatilization are competing reactions during the oxidation of carbonaceous materials and are important processes in many different areas of science and technology. Here, we present a combined ambient pressure X-ray photoelectron spectroscopy (APXPS) and grazing incidence X-ray scattering (GIXS) investigation of the oxidation of oleic acid ligands surrounding NaYF 4 nanoparticles (NPs) deposited onto SiO x /Si substrates. While APXPS monitors the evolution of the oxidation products, GIXS provides insight into the morphology of the ligands and particles before and after the oxidation. Our investigation shows that the oxidation of the oleic acid ligands proceeds at O 2 partial pressures of below 1 mbar in the presence of X-rays, with the oxidation eventually reaching a steady state in which mainly CH x and –COOH functional groups are observed. The scattering data reveal that the oxidation and volatilization reaction proceeds preferentially on the side of the particle facing the gas phase, leading to the formation of a chemically and morphologically asymmetric ligand layer. This comprehensive picture of the oxidation process could be obtained only by combining the X-ray scattering and APXPS data. The investigation presented here lays the foundation for further studies of the stability of NP layers in the presence of reactive trace gases and ionizing radiation and for other nanoscale systems where chemical and morphological changes happen simultaneously and cannot be understood in isolation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predicting the performance of local seismic networks using Matlab and Google Earth.

We have used Matlab and Google Earth to construct a prototype application for modeling the performance of local seismic networks for monitoring small, contained explosions. Published equations based on refraction experiments provide estimates of peak ground velocities as a function of event distance and charge weight. Matlab routines implement these relations to calculate the amplitudes across a network of stations from sources distributed over a geographic grid. The amplitudes are then compared to ambient noise levels at the stations, and scaled to determine the smallest yield that could be detected at each source location by a specified minimum number of stations. We use Google Earth as the primary user interface, both for positioning the stations of a hypothetical local network, and for displaying the resulting detection threshold contours.

99 GENERAL AND MISCELLANEOUS↗

Perovskite nickelates as electric-field sensors in salt water

Designing materials to function in harsh environments, such as conductive aqueous media, is a problem of broad interest to a range of technologies, including energy, ocean monitoring and biological applications. The main challenge is to retain the stability and morphology of the material as it interacts dynamically with the surrounding environment. Materials that respond to mild stimuli through collective phase transitions and amplify signals could open up new avenues for sensing. Here we present the discovery of an electric-field-driven, water-mediated reversible phase change in a perovskite-structured nickelate, SmNiO 3 . This prototypical strongly correlated quantum material is stable in salt water, does not corrode, and allows exchange of protons with the surrounding water at ambient temperature, with the concurrent modification in electrical resistance and optical properties being capable of multi-modal readout. Besides operating both as thermistors and pH sensors, devices made of this material can detect sub-volt electric potentials in salt water. Finally, we postulate that such devices could be used in oceanic environments for monitoring electrical signals from various maritime vessels and sea creatures

36 MATERIALS SCIENCE↗

In situ , in vivo , and in operando imaging and spectroscopy of liquids using microfluidics in vacuum

This review offers a succinct overview of the development of a vacuum-compatible microfluidic reactor system for analysis at the liquid vacuum interface (SALVI), and its diverse applications in in situ, in vivo, and in operando imaging of liquid surfaces as well as the air-liquid (a-l), liquid-liquid (l-l), and solid-liquid (s-l) interfaces in the past decade. SALVI is one of the first microfluidics-based reactors that has enabled direct analysis of volatile liquids in vacuum surface tools such as scanning electron microscopy (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Its integration into ambient and vacuum spectroscopy and microscopy is illustrated. Several applications are highlighted including (1) imaging nanoparticles in liquid using in situ SEM; (2) mapping the evolving l-l interface using in situ x-ray absorption spectroscopy and ToF-SIMS; (3) following complex a-l interfacial oxidation reaction products using in situ ToF-SIMS; (4) capturing biological interfaces of cells and microbes via in vivo multimodal and correlative imaging; and (5) monitoring the dynamic solid electrode and liquid electrolyte interface using in operando molecular imaging. Finally, outlook and recommendations are presented. Besides showing the holistic information volume obtained by real-time multiplexed imaging, this review intends to convey the importance of tool development in revolutionizing surface and interface analysis using vacuum platforms previously limited to solid surfaces. Microfluidics is manifested to be not limited to ambient conditions in many examples in this review. Moreover, fundamental interfacial phenomena underpinning mass and charge transfer can now be pursued in real time via innovated chemical imaging and spectroscopy.

42 ENGINEERING↗