SEARCH · Engineering Papers
Results for “Accelerated Testing”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Failure Mode and Effects Analysis (FMEA) for Photovoltaic Inverter
Photovoltaic (PV) inverters are critical yet vulnerable components in modern energy systems, often acting as reliability bottlenecks that increase the levelized cost of energy (LCOE). To address this, this paper presents a comprehensive Failure Mode and Effects Analysis (FMEA) tailored for PV inverters. Leveraging field data and literature, we identify failure-prone components, such as capacitors,, and relays, and prioritize their risks based on quantitative Risk Priority Numbers (RPNs). The analysis reveals that surge-induced MOV short circuits, capacitor degradation, and environmental cooling fan failures dominate the risk profile. These findings provide a targeted framework for reliability improvement, guiding future efforts in predictive diagnostics, design optimization, and accelerated life testing strategies.
Near-Busbar Degradation of Screen-Printed Metallization in Silicon Photovoltaic Modules
We study photovoltaic (PV) module degradation after extended accelerated stress testing including 2000 hours of damp heat followed by a current-injection procedure meant to stabilize defects linked to light-induced degradation. In addition to de-stabilization/recovery of light-induced defects, we observe severe series resistance due to loss of contact between the Si cell and near-busbar screen-printed metallization (i.e. grid finger delamination). Using scanning electron microscopy and energy dispersive x-ray spectroscopy on cell fragments cored from the module, we show poor contact is caused by a gap between the screen-printed Ag metallization and Si due to missing glass frit.
In-Situ Luminescence Imaging of Perovskite Solar Cells Demonstrates Increasing Spatial Nonuniformity Upon Light-Soaking Degradation
In this work we investigate degradation rates of triplecation mixed-halide perovskite p-i-n solar cells. We present an accelerated stress testing procedure using periodic blue light-soaking at elevated temperatures until devices reach ~80% of their initial efficiency. We track light-induced degradation via in-situ: photoluminescence (PL), current-voltage (I-V) curves, and transient photovoltage. Devices underwent 165 hours of light bias at 65degrees C. Results suggest that spatial uniformity in PL intensity decreases as device degradation increases. This investigation lays the groundwork to address the current gap in understanding the interplay between device performance and the evolution of macroscopic features in perovskite solar cells. Thus, we believe spatial characterization techniques will play a crucial role in the commercialization of perovskite solar cells.
Increasing Multilayer Ceramic Capacitor Lifetime With Bipolar Voltage Cycling
Enhancing the lifetime of multilayer ceramic capacitors (MLCCs) is critical in many aerospace, naval, or electrical grid applications, where device failure could lead to catastrophic consequences. The migration of oxygen vacancies from the ceramic to the electrode interface under constant bias is known to reduce the lifetime of oxide-based MLCCs. Bias cycling presents an opportunity to enhance MLCC lifetime by reducing oxygen vacancy migration. The ideal frequency range is expected to lie between frequencies low enough to avoid self-heating but high enough to avoid interfacial defect formation. However, the impact of low-frequency bipolar voltage cycling (BVC) on MLCC degradation mechanisms has not been well studied. This work investigates the impact of periodic BVC on the degradation of MLCCs through highly accelerated lifetime testing (HALT) on X7R capacitors. HALT tests were conducted at 255 °C and 60 V using different switching frequencies: 0 (dc), 0.1, 2.5, and 10 Hz. BVC was found to improve the lifetime of MLCCs compared to dc test conditions. MLCCs tested at 10-Hz BVC showed a 311% increase in average time to failure compared to the dc case. Impedance spectroscopy shows that BVC decreases the rate of resistance degradation within MLCCs, indicating that oxygen vacancy migration to the electrodes is mitigated. The impedance spectra taken on BVC samples highlight how grain boundaries play a vital role in trapping oxygen vacancies. Periodic cycling causes oxygen vacancies to become trapped at grain boundaries, resulting in oxygen vacancies taking longer to reach the electrode interface and thus increasing MLCC lifetime. This work highlights not only how BVC can be used to increase MLCC lifetime but also how periodically cycling MLCCs could increase lifetime in extreme environments, such as at elevated temperatures and electric fields.
Thermo-Oxidation Analysis of Structural Adhesives: An Experimental Study
Abstract Cross-linked polymers play an important role in structural applications as adhesives. In this article, we performed an experimental study to understand the effects of high temperature i.e. thermo-oxidative aging on the mechanical behavior of polymers. Subsequently, the constitutive behavior, i.e. stress-strain relation of these adhesives before and after the accelerated aging tests were studied on samples aged at different temperature and different time durations at zero humidity. The aging conditions and periods selected for the tests have been specifically designed to simulate the effects of aging under the working conditions that the materials will be subjected to in their standard applications. The focus of this study is on the investigation of the effects of aging on the polymeric adhesives used in automotive applications. Consequently, four different polymeric adhesives (one silicone-based, two polyurethane-based, and one acrylic type), which are being used extensively in these applications, have been chosen. The quasi-static tensile loading was used on these four adhesives and the changes in the constitutive behavior were measured. The failure tensile tests as well as the cyclic tensile tests were performed in our lab using a Test-Resources tensile testing machine. The temperatures that were used in this work are 60, 80 and 95°C for varying aging periods of 24hrs, 240hrs, and 720hrs. Then, all the data was collected and consequently analyzed, and the resulting behavior was compared to that of the unaged material, showing varying results depending on the material, temperature, and aging period. Different behaviors have been observed after aging. The polymers’ behavior was expanding from no effect to significant damage caused by aging conditions. This work provides the core understanding required for modeling the material behavior during aging and lays down the groundwork for further data-infused model-free approaches.
La- and Mn-doped cobalt spinel oxygen evolution catalyst for proton exchange membrane electrolysis
Discovery of earth-abundant electrocatalysts to replace iridium for the oxygen evolution reaction (OER) in a proton exchange membrane water electrolyzer (PEMWE) represents a critical step in reducing the cost for green hydrogen production. Here we report a nanofibrous cobalt spinel catalyst codoped with lanthanum (La) and manganese (Mn) prepared from a zeolitic imidazolate framework embedded in electrospun polymer fiber. The catalyst demonstrated a low overpotential of 353 millivolts at 10 milliamperes per square centimeter and a low degradation for OER over 360 hours in acidic electrolyte. A PEMWE containing this catalyst at the anode demonstrated a current density of 2000 milliamperes per square centimeter at 2.47 volts (Nafion 115 membrane) or 4000 milliamperes per square centimeter at 3.00 volts (Nafion 212 membrane) and low degradation in an accelerated stress test.
Impact of Carbon Support Structure on the Durability of PtCo Electrocatalysts
High performing, low-Pt content fuel cell membrane electrode assemblies (MEAs) are critical to the economic viability of proton exchange membrane fuel cells (PEMFCs) for the transportation industry. Considerable research has been conducted to reduce the Pt content in fuel cells, leading to the development of transition metal alloys, such as Platinum-Cobalt (PtCo). The degree of degradation of PtCo catalysts can be impacted by the catalyst metal itself and its interactions with the carbon support. Several low-loaded PtCo MEAs were fabricated, with various combinations of porous and solid carbon cathode catalyst supports. The MEAs were subjected to an accelerated stress test (AST), and the catalyst degradation characterized using electrochemical, X-ray scattering, and electron microscopy techniques. Porous supports retain more of their electrochemically-active surface area (ECSA) and demonstrate higher performance after the AST. Overall, this is believed to be due to the ability of the porous supports to trap the metal particles within the pores, slowing their dissolution/precipitation, and agglomeration.
Review—Development of Highly Active and Durable Hybrid Compressive Platinum Lattice Catalysts for Polymer Electrolyte Membrane Fuel Cells: Mathematical Modeling and Experimental Work
This review provides a comprehensive overview on the development of highly active and durable platinum catalysts with ultra-low Pt loadings for polymer electrolyte membrane fuel cells (PEMFCs) through a combined mathematical modeling and experimental work. First, simulation techniques were applied to evaluate the validity of the Tafel approximation for the calculation of the mass activity (MA) and specific activity (SA). A one-dimensional agglomeration model was developed and solved to understand the effects of exchange current density, porosity, agglomerate size, Nafion ® film thickness, and Pt loading on the MA and SA. High porosity (> 60%) and agglomerations at high Pt loadings cause the loss of the Tafel approximation and consequently the decrease in MA and SA. A new structure parameter was introduced to estimate the real porous structure using the fractal theory. The volumetric catalyst density was corrected by the fractal dimension (measured by Hg porosimetry), which gave a good agreement with the experimental values. The loading-dependent Tafel equation was then derived, which contains both the utilization and the non-linear scaling factor. Second, activated carbon composite support (ACCS) with optimized surface area, porosity, pore size, and pore size distribution was developed. The hydrophilic/hydrophobic ratio, structural properties (amorphous/crystalline ratio), and the number of active sites were optimized through metal-catalyzed pyrolysis. Stability of ACCS and Pt/ACCS were evaluated using an accelerated stress test (AST). The results indicated that Pt/ACCS showed no significant loss of MA and power density after 5,000 cycles at 1.0–1.5 V, while the commercial Pt/C catalysts showed drastic losses of MA and power density. Finally, monolayers of compressed Pt (core–shell-type Pt 3 Co 1 ) catalysts were structured by diffusing Co atoms (previously embedded in ACCS) into Pt. Compressive Pt lattice (Pt * ) catalysts were synthesized through an annealing procedure developed at the University of South Carolina (USC). The Pt * /ACCS catalyst showed high initial power density (rated) of 0.174 g Pt kW −1 and high stability (24 mV loss) at 0.8 A cm −2 after 30,000 cycles (0.6–1.0 V). The outstanding performance of Pt * /ACCS is due to the synergistic effect of ACCS and compressive Pt * lattice.
Corrosion of Commercial Mg–Al Alloys: AZ31B, AM60, and AZ91D
Aqueous corrosion, atmospheric corrosion, and ionic liquid dissolution studies were performed on commercial alloys AZ31B, AM60, and AZ91D and compared with previously reported results for single-phase binary Mg–Al alloys containing similar Al concentrations (αMg-2 at% Al, αMg-5 at% Al, and Mg-8 at% Al). Polarization studies in 0.6 M NaCl were used to characterize the aqueous free corrosion behavior during 20-h free immersion. Accelerated corrosion testing was performed using a rotating-disk electrode which revealed the evolution of an Al-rich mud-cracking and platelet morphology. Atmospheric droplet testing showed rapid pH increases that depended on the Al concentration in the alloy. Time-dependent contact angle measurements showed that the degree of droplet wetting increased during free corrosion by ~50° over 20 h in 0.6 M NaCl. Ionic liquid dissolution studies in 1:2 M choline chloride:urea deep eutectic solvent were performed in order to examine the current-voltage behavior of these alloys in the absence of water and hydrogen reduction. The results of these studies revealed the formation of nanowire corrosion morphologies within a honeycomb lattice structure which we attribute to selective dissolution of Mg via a two-dimensional stepflow process
Stability of Atomically Dispersed Fe–N–C ORR Catalyst in Polymer Electrolyte Fuel Cell Environment
We have investigated the durability of a platinum group metal (PGM-)free Fe–N–C catalyst in which the Fe sites are atomically dispersed (AD), and found it to be quite stable in standard accelerated stress test (AST) cycles normally used for low-PGM catalysts: a square wave with 0.6 V lower potential limit (LPL)—0.95 V upper potential limit (UPL) with 3-s holds at UPL and LPL in H 2 /N 2 , at 1.5 atm, 80 °C and 100% RH. Considering the metrics normally employed to characterize the durability of the low-PGM catalysts after 30,000 AST cycles, this PGM-free catalyst lost <50% catalyst activity, <50% H 2 /air performance at 0.8 V, and 40 mV at 1.5 A cm -2 . However, it is less stable in H 2 /air, losing ~50% catalyst activity after just 7.5 h of polarization measurements (load cycles). In combined cycles, the majority of the loss in catalyst activity occurred during the load cycles in H 2 /air rather than AST cycles in H 2 /N 2 . We have concluded that, unlike low-PGM catalysts that lose electrochemically active surface area (ECSA) through potential cycling-induced processes, (AD)Fe–N–C catalysts degrade by processes associated with the presence of oxygen.
Impact of Catalyst Ink Dispersing Solvent on PEM Fuel Cell Performance and Durability
The dispersing solvent used for fuel cell catalyst ink preparation plays a vital role in establishing the resulting morphology of the electrode layers, which in turn will impact the performance of proton exchange membrane (PEM) fuel cells. In this study, we report the impact of various ionomer dispersion solvents on PEM fuel cell performance and durability; two aqueous (1-propanol/water and 2-propanol/water) and several non-aqueous dispersing solvents (ethylene glycol and 1,2-butanediol) are compared. The cathode catalyst layer (CCL) fabricated using inks prepared with 1-propanol/water (3:1, w/w) exhibited the best initial performance followed by the CCL prepared using ethylene glycol. The CCLs made from non-aqueous ethylene glycol and 1,2-butanediol exhibited the best durability upon accelerated stress testing. Scanning transmission electron microscopy combined with energy dispersive X-ray spectroscopy indicated that, after the stress test, the distribution of both the Nafion ionomer and Pt nanoparticles within the CCLs prepared with non-aqueous ionomer dispersions underwent less change than those prepared with aqueous dispersions, which is responsible for the improved durability
Achieving 5,000-h and 8,000-h Low-PGM Electrode Durability on Automotive Drive Cycles
Whereas total Pt loading in anode and cathode catalysts below 0.125 mg cm −2 is required to meet the stringent cost target for automotive fuel cell systems (FCS) for light duty vehicles, low-loaded cathode catalysts are susceptible to unacceptable aging-related performance losses at high current densities. A framework model, validated by accelerated stress test data, has identified cell voltage, relative humidity (RH) and temperature as the key operating variables that affect degradation of a high-activity d-PtCo/C cathode catalyst with 0.1 mg cm −2 Pt loading. Drive cycle simulations indicate that these can be controlled by properly selecting the minimum FCS power, compressor-expander module (CEM) turndown, and stack coolant temperature. The optimum system parameters are 4-kW e minimum power for an 80-kW e FCS, CEM turndown of 12.5, and 66 °C average coolant exit temperature that combine to limit the maximum cell voltage to 850 mV and outlet RH to 90%–100%. Depending on Pt loading, the mismatch between actual and allowable degradation for 10% power loss over 5,000-h lifetime requires the stack to be oversized by 2.4%–5%, resulting in 8.4%–41% lower Pt utilization and 7.1%–20.5% penalty in stack cost. The corresponding results for 8,000-h lifetime are 10.3%-14% stack oversizing, 23%–51.8% lower Pt utilization, and 24.1%–35.4% stack cost penalty.
Impact of Carbon Support Structure on the Durability of PtCo Electrocatalysts
High performing, low-Pt content fuel cell membrane electrode assemblies (MEAs) are critical to the economic viability of proton exchange membrane fuel cells (PEMFCs) for the transportation industry. Considerable research has been conducted to reduce the Pt content in fuel cells, leading to the development of transition metal alloys, such as Platinum-Cobalt (PtCo). The degree of degradation of PtCo catalysts can be impacted by not only the composition and morphology of the catalyst particle itself, but also its interactions with the carbon support. In this study several low-PtCo MEAs were fabricated, with various combinations of porous and solid carbon cathode catalyst supports. The MEAs were subjected to an accelerated stress test (AST), and the catalyst degradation characterized using electrochemical, X-ray scattering, and electron microscopy techniques. Porous supports retain more of their electrochemically-active surface area (ECSA) and demonstrate higher performance after the AST. This is believed to be due to the ability of the porous supports to trap the metal particles within the pores, slowing their dissolution/precipitation, and agglomeration. However porous supports also exhibit greater increases in transport resistance probably associated with enhanced Co leaching under the AST conditions.
Investigation of Membrane Chemical Degradation as a Function of Catalyst Platinum Loading
Membrane chemical degradation is one of many factors that can impact fuel cell durability. Additionally, the fuel cell’s lifetime heavily depends on the membrane and its ability to maintain chemical and mechanical integrity. Previous studies indicate that chemical degradation is due to the formation of hydroxyl radicals that attack the polymer structure resulting in membrane thinning, pinhole formation, and the release of fluoride and sulfate ions. Membrane durability was investigated using ultra-low Pt electrode loadings (≤ 0.1 mg Pt cm -2 ). Accelerated stress testing (US-DOE protocols) demonstrated that the degradation rate was found to increase with higher Pt loadings. This is most likely due to more heterogeneous sites for radical formation due to hydrogen crossover to the cathode. We also explored membrane degradation rates while varying catalyst layer thickness, ionomer to carbon ratio, and types of carbon support. All of the aforementioned variables impact the membrane degradation rates.
Mitigation of PtCo/C Cathode Catalyst Degradation via Control of Relative Humidity
Maintaining the high performance of proton-exchange membrane fuel cells (PEMFC) over the course of its lifetime is a key enabling factor for its successful commercialization as a primary power source in zero-emission transportation applications. In this context, it is important to mitigate the degradation of PtCo-alloy based cathode catalysts used for oxygen reduction reaction (ORR). PtCo-alloy catalysts exhibit high activity at beginning-of-life (BOL) which tends to decrease during operation due to loss of electrochemical surface area (ECSA) and dissolution-contamination related effects of the Co-alloying component. Here, we demonstrate the use of relative humidity (RH) of the inlet gases as a controllable parameter to mitigate the degradation of PtCo-alloy catalyst degradation. We employ a catalyst-specific voltage cycling accelerated stress test (AST) durability protocol as a function of inlet RH to degrade PtCo catalysts. A series of in situ electrochemical diagnostics and ex situ characterizations have been carried out to investigate the catalyst layer characteristics at end-of-test (EOT). Our results show that at sub-saturated conditions of durability protocol operation, PtCo catalyst sustains higher EOT H 2 /air performance due to better retention of ECSA and smaller impact of Co 2+ dissolution/contamination.
Performance and Durability of Proton Exchange Membrane Vapor-Fed Unitized Regenerative Fuel Cells
With a growing demand for electricity, clean hydrogen production and usage can be an asset not only to mitigate emissions but for long-term energy storage as well. Hydrogen gas, a high-density energy carrier, can be made through electrolysis in charging mode and generate electricity via a fuel cell in discharging mode in a unitized regenerative fuel cell (URFC). While URFCs reduce cost by combining the charging and discharging modes into a singular device, switching between modes becomes burdensome, and water management is a major challenge. One way to mitigate these issues is to operate the entire system in the vapor phase. Vapor-phase operation simplifies the physics of the system but will introduce losses within the system, primarily ohmic and mass transport during the charging mode. In this study, we explore the performance of a Proton-Exchange-Membrane (PEM)-URFC under vapor-phase conditions and the impact of different PEMs, feed gases, and relative humidity on the performance and durability. By tailoring operating conditions and membrane, the vapor-URFC achieves a roundtrip efficiency of 42% and a lifetime of 50,000 accelerated stress test cycles for fully humidified feeds. Discussion of vapor-URFC for energy storage and extensions to look at various applications shows the promise of this technology.
Machine-Learning Assisted Identification of Accurate Battery Lifetime Models with Uncertainty
Reduced-order battery lifetime models, which consist of algebraic expressions for various aging modes, are widely utilized for extrapolating degradation trends from accelerated aging tests to real-world aging scenarios. Identifying models with high accuracy and low uncertainty is crucial for ensuring that model extrapolations are believable, however, it is difficult to compose expressions that accurately predict multivariate data trends; a review of cycling degradation models from literature reveals a wide variety of functional relationships. Here, a machine-learning assisted model identification method is utilized to fit degradation in a stand-out LFP-Gr aging data set, with uncertainty quantified by bootstrap resampling. The model identified in this work results in approximately half the mean absolute error of a human expert model. Models are validated by converting to a state-equation form and comparing predictions against cells aging under varying loads. Parameter uncertainty is carried forward into an energy storage system simulation to estimate the impact of aging model uncertainty on system lifetime. The new model identification method used here reduces life-prediction uncertainty by more than a factor of three (86% ± 5% relative capacity at 10 years for human-expert model, 88.5% ± 1.5% for machine-learning assisted model), empowering more confident estimates of energy storage system lifetime.