Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APPL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

A thermodynamic analysis of native point defect and dopant solubilities in zinc-blende III-V semiconductors

A thermodynamic model is used to analyze available experimental data relevant to point defects in the binary zinc-blende III-V compounds (Ga,In)-(P,As,Sb). The important point defects and their complexes in each of the materials are identified and included in the model. Essentially all of the available experimental data on dopant solubility, crystal density, and lattice parameter of melt and solution grown crystals and epilayers are reproduced by the model. It extends an earlier study [Hurle, J. Appl. Phys. 85, 6957 (1999)] devoted solely to GaAs. Values for the enthalpy and entropy of formation of both native and dopant related point defects are obtained by fitting to experimental data. In undoped material, vacancies, and interstitials on the Group V sublattice dominate in the vicinity of the melting point (MP) in both the phosphides and arsenides, whereas, in the antimonides, vacancies on both sublattices dominate. The calculated concentrations of the native point defects are used to construct the solidus curves of all the compounds. The charged native point defect concentrations at the MP in four of the six materials are significantly higher than their intrinsic carrier concentrations. Thus the usually assumed high temperature 'intrinsic' electroneutrality condition for undoped material (n=p) is not valid for these materials. In GaSb, the Ga{sub Sb} antisite defect appears to be grown-in from the melt. This contrasts with the As{sub Ga} defect in GaAs for which the concentration grown-in at the MP is negligibly small. Compensation of donor-doped material by donor-Group III vacancy complexes is shown to exist in all the compounds except InP where Group VI doped crystals are uncompensated and in InSb where there is a lack of experimental data. The annealing effects in n{sup +} GaAs, including lattice superdilation, which were shown in the earlier paper to be due to Group III vacancy undersaturation during cooling, are found to be present also in GaSb and InAs. Results for native point defects are compared with reported ''first principles'' calculations for GaAs. It is seen that, while there is some accord with experimental findings for low temperature molecular beam epitaxial (MBE) growth, they fail totally to predict the behavior under high temperature growth conditions. The analysis of data on liquid phase epitaxy (LPE) growth of GaAs from Bi solution in the earlier paper has been re-calculated in the light of experimental data that showed that the model used in that paper to represent the Ga-As-Bi phase equilibria was inadequate. An improved model reveals that Ga vacancies exert a greater effect in controlling the extent of the linear range of donor dopant solubility than previously predicted. It has also led to a re-evaluation of the equilibrium EL2 and Ga vacancy concentrations in GaAs during MBE growth under As-rich conditions at low temperatures ({approx}500 K). The amended model predicts that the very high concentrations of EL2 and of Ga vacancies observed experimentally are near equilibrium values. The predicted increase in the equilibrium concentrations of these defects at low temperatures results from coulombic attraction between the two defects. At temperatures somewhat lower than 500 K the rate of increase becomes catastrophic.

36 MATERIALS SCIENCE↗

SAMRAI: A novel variably polarized angle-resolved photoemission beamline in the VUV region at UVSOR-II

A novel variably polarized angle-resolved photoemission spectroscopy beamline in the vacuum-ultraviolet (VUV) region has been installed at the UVSOR-II 750 MeV synchrotron light source. The beamline is equipped with a 3 m long APPLE-II type undulator with horizontally/vertically linear and right/left circular polarizations, a 10 m Wadsworth type monochromator covering a photon energy range of 6-43 eV, and a 200 mm radius hemispherical photoelectron analyzer with an electron lens of a {+-}18 deg. acceptance angle. Due to the low emittance of the UVSOR-II storage ring, the light source is regarded as an entrance slit, and the undulator light is directly led to a grating by two plane mirrors in the monochromator while maintaining a balance between high-energy resolution and high photon flux. The energy resolving power (h{nu}/{Delta}h{nu}) and photon flux of the monochromator are typically 1x10{sup 4} and 10{sup 12} photons/s, respectively, with a 100 {mu}m exit slit. The beamline is used for angle-resolved photoemission spectroscopy with an energy resolution of a few meV covering the UV-to-VUV energy range.

43 PARTICLE ACCELERATORS↗

Drift-Alfven waves induced optical emission fluctuations in Aditya tokamak

In Aditya tokamak [S. B. Bhatt et al. Indian J. Pure Appl. Phys. 27, 710 (1989)], an increase in the H{sub a}lpha and C{sup 2+} intensity fluctuations from the edge region is observed with an increase in the magnetohydrodynamic (MHD) activity. Very small fluctuation amplitudes of H{sub a}lpha and C{sup 2+} intensity are observed in discharges where there is no MHD activity compared to the discharges with MHD activity. These fluctuations in the H{sub a}lpha and C{sup 2+}, measured by optical filter--photomultiplier tube combination--are modulated by Mirnov oscillations having a dominant peak with a common frequency approx7-10 kHz. Further investigation reveals the presence of strong coherent fluctuations in density and floating potential at same frequency as well. These observations indicate the existence of a nonelectrostatic instability, which may be based on the coupled mode of the drift mode and the Alfven mode. The coherent density fluctuations give rise to the experimentally observed coherent H{sub a}lpha and C{sup 2+} intensity fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TEMPO: a New Insertion Device Beamline at SOLEIL for Time Resolved Photoelectron Spectroscopy Experiments on Solids and Interfaces

A new insertion device beamline is now operational on straight section 8 at the SOLEIL synchrotron radiation source in France. The beamline and the experimental station were developed to optimize the study of the dynamics of electronic and magnetic properties of materials. Here we present the main technical characteristics of the installation and the general principles behind them. The source is composed of two APPLE II type insertion devices. The monochromator with plane gratings and spherical mirrors is working in the energy range 40-1500 eV. It is equipped with VLS, VGD gratings to allow the user optimization of flux or higher harmonics rejection. The observed resonance structures measured in gas phase enable us to determine the available energy resolution: a resolving power higher than 10000 is obtained at the Ar 2p, N 1s and Ne K-edges when using all the optical elements at full aperture. The total flux as a function of the measured photon energy and the characterization of the focal spot size complete the beamline characterization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Commissioning of a Soft X-ray Beamline PF-BL-16A with a Variable-Included-Angle Varied-Line-Spacing Grating Monochromator

The design and commissioning of a new soft X-ray beamline, BL-16A, at the Photon Factory is presented. The beamline consists of a pre-focusing mirror, an entrance slit, a variable-included-angle varied-line-spacing plane grating monochromator, and a post-focusing system as usual, and provides circularly and linearly polarized soft X rays in the energy range 200-1500 eV with an APPLE-II type undulator. The commissioning procedure for the beamline optics is described in detail, especially the check of the focal position for the zero-th order and diffracted X rays.

43 PARTICLE ACCELERATORS↗

The Nanoscience Beamline (I06) at Diamond Light Source

The Nanoscience beamline (I06) is one of seven Diamond Phase-I beamlines which has been operational since January 2007 delivering polarised soft x-rays, for a PhotoEmission Electron Microscope (PEEM) and branchline, in the energy range 80-2100 eV. The beamline is based on a collimated plane grating monochromator with sagittal focusing elements, utilising two APPLE II helical undulator sources, and has been designed for high flux density at the PEEM sample position. A {approx}5 {mu}m ({sigma}) diameter beam is focussed onto the sample in the PEEM allowing a range of experiments using x-ray absorption spectroscopy (XAS), x-ray magnetic circular dichroism (XMCD) and x-ray magnetic linear dichroism (XMLD) as contrast mechanisms. The beamline is also equipped with a branchline housing a 6T superconducting magnet for XMCD and XMLD experiments. The magnet is designed to move on and off the branchline which allows a diverse range of experiments.

43 PARTICLE ACCELERATORS↗

Compensation of Beam Line Polarizing Effects at UE112 of BESSY II

Reflections in synchrotron radiation beam lines tend to change the state of polarization of the radiation. This effect is more pronounced for steep angle of incidence, i.e. at low photon energy (say below 100 eV) beam lines. The APPLE II undulator UE112 at BESSY has all four magnetic rows shiftable and thus generates any state of polarization. To provide any intended polarization state at the sample we perform polarization measurements based on simple and fast linear polarization analysis that together with calculations of the undulator radiation predicts undulator settings that cancel beam line polarization effects.

43 PARTICLE ACCELERATORS↗

New Soft X-ray Beamline (BL10) at the SAGA Light Source

A new soft X-ray beamline (BL10) at the SAGA Light Source (SAGA-LS) was constructed at the end of 2008. Commissioning of this new beamline started at the beginning of 2009. Synchrotron radiation from a variably polarizing undulator (APPLE-II) can be used in this beamline. The obtained light is monochromatized by a varied-line-spacing plane grating monochromator with the variable included angle mechanism. Its designed resolving power and photon flux are 3,000-10,000 and 10{sup 12}-10{sup 9} photons/s at 300 mA, respectively. The performance test results were generally satisfactory. An overview of the optical design of the beamline and the current status of commissioning are reported.

43 PARTICLE ACCELERATORS↗

A panoply of insertion devices at SOLEIL for a wide spectral range and flexible polarisation

The SOLEIL storage ring presents a very high fraction of its circumference dedicated to accommodate Insertion Devices (ID). Over the 25 presently planned insertion devices presenting a large variety of systems, 16 have been already installed and commissioned in September 2009. The UV-VUV region is covered with electromagnetic devices, offering tuneable polarisations. An electromagnet/permanent magnet undulator using copper sheets coils for fast switching of the helicity is under construction. 13 APPLE-II type undulators, with period ranging from 80 down to 36 mm, provide photons in the 0.1-10 keV region, some of them featuring tapering or quasi-periodicity. Five U20 in vacuum undulators cover typically the 3-30 keV range whereas an in vacuum wiggler, with compensation of the magnetic forces via adequate springs will cover the 10-50 keV spectral domain. R and D on cryogenic in-vacuum undulator is also under progress. A magnetic chicane using permanent magnet dipoles has also been designed in order to accommodate two canted undulators on the same straight section. A wiggler dedicated to slicing (production of femto second long pulses) is also being designed, its radiation will also serve for an X-ray beamline.

43 PARTICLE ACCELERATORS↗

Measurement of the Magnet Blocks for SSRF Insertion Devices

Two in-vacuum undulators IVU25s and one elliptically polarized undulator EPU100 have been developed for SSRF. Two IVU25s with the same hybrid design contain about 640 Sm{sub 2}Co{sub 17} magnet blocks and the dimension of blocks is 65 Wx25 Hx9 D. The EPU100 of the APPLE-II type contains about 690 NdFeB magnet blocks with the dimension of 35 Wx35 Hx25 D. This paper describes the magnetic measurements of these magnet blocks with the Helmholtz coil measurement system for IVU25 magnet blocks and the Hall probe measurement system for EPU100 magnet blocks. The measured maximum magnetic moment deviation and the maximum angle deviation are less than {+-}1.0% and 1.1 deg. respectively both for Sm{sub 2}Co{sub 17} blocks and NdFeB blocks and satisfy the specifications of undulators.

43 PARTICLE ACCELERATORS↗

Status of the SAGA Light Source

The SAGA Light Source (SAGA-LS) is a synchrotron radiation facility consisting of a 255 MeV injector linac and a 1.4 GeV storage ring that is 75.6 m in circumference. The SAGA-LS has been stably providing synchrotron radiation to users since it first started user operation in February 2006. Along with the user operation, various machine improvements have been made over the past years, including upgrading the injector linac control system, replacing a septum magnet and constructing a beam diagnostic system. In addition to these improvements, insertion devices have been developed and installed. An APPLE-II type variable polarization undulator was installed in 2008. To address the demand from users for high-flux hard x-rays, a superconducting 4 T class wiggler is being developed. An experimental setup for generating MeV photons by laser Compton scattering is being constructed for beam monitoring and future user experiments.

43 PARTICLE ACCELERATORS↗

Synchronized monochromator and insertion device energy scans at SLS

Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a 'master' controlling the undulator 'slave' energy position. This master-slave software implementation exploits EPICS distributed device control over computer network and allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.

43 PARTICLE ACCELERATORS↗

Atmospheric pressure plasma jets beyond ground electrode as charge overflow in a dielectric barrier discharge setup

With a proper combination of applied voltage and the width of ground electrode, atmospheric pressure plasma jets extending beyond the ground electrode, whether it sits on the downstream or the upstream side, can be equally obtained with a dielectric barrier discharge setup, which can be ascribed to the overflow of deposited charges [J. Appl. Phys. 106, 013308 (2009)]. Here, we show that, by using narrower ground electrodes, such an overflow jet can be successfully launched at a much reduced voltage (down to below 10 kV). Moreover, by using transparent and triadic ground electrodes, development of charge overflow beneath the ground electrode was temporally and spatially resolved. Temporal evolution of discharge currents measured on the severed ground electrode helps establish the propagation dynamics of discharges along the dielectric surface beneath ground electrode, and also reinforces the conception that the streamer's head is in connection to the active electrode via a conducting channel. A small propagation velocity of 3.3x10{sup 3} m/s was measured for the ''overflow'' jet inside the dielectric tube. The availability of such overflow jets is enormously advantageous concerning their application to living bodies, to which the high voltage at active electrode is lethally dangerous.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Runaway-loss induced negative and positive loop voltage spikes in the Aditya Tokamak

Negative spikes followed by positive ones in the loop voltage signal during the discharge are observed in the Aditya Tokamak [S. B. Bhatt et al., Indian J. Pure Appl. Phys. 27, 710 (1989)]. These spikes are always accompanied by hard x-ray bursts caused by sudden loss of runaway electrons. The observed growth of m=3 mode seemed responsible for the losses of localized beams of runaway electrons (E{sub {gamma}{approx}1}-5 MeV) from the plasma region around q=3 magnetic surface. The movement of these runaway electrons during their extraction from inside the plasma induces both positive and negative electric fields at those locations. In this paper, a one-dimensional toroidal electric field diffusion model is used to estimate the induced electric field at the plasma boundary, which matches quite well with the observed spikes in loop voltage in both magnitude as well as its temporal evolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-shot electron bunch length measurements using a spatial electro-optical autocorrelation interferometer

A spatial, electro-optical autocorrelation (EOA) interferometer using the vertically polarized lobes of coherent transition radiation (CTR) has been developed as a single-shot electron bunch length monitor at an optical beam port downstream the 100 MeV preinjector LINAC of the Swiss Light Source. This EOA monitor combines the advantages of step-scan interferometers (high temporal resolution) [D. Mihalcea et al., Phys. Rev. ST Accel. Beams 9, 082801 (2006) and T. Takahashi and K. Takami, Infrared Phys. Technol. 51, 363 (2008)] and terahertz-gating technologies [U. Schmidhammer et al., Appl. Phys. B: Lasers Opt. 94, 95 (2009) and B. Steffen et al., Phys. Rev. ST Accel. Beams 12, 032802 (2009)] (fast response), providing the possibility to tune the accelerator with an online bunch length diagnostics. While a proof of principle of the spatial interferometer was achieved by step-scan measurements with far-infrared detectors, the single-shot capability of the monitor has been demonstrated by electro-optical correlation of the spatial CTR interference pattern with fairly long (500 ps) neodymium-doped yttrium aluminum garnet (Nd:YAG) laser pulses in a ZnTe crystal. In single-shot operation, variations of the bunch length between 1.5 and 4 ps due to different phase settings of the LINAC bunching cavities have been measured with subpicosecond time resolution.

36 MATERIALS SCIENCE↗

Equivalence of The (G'/G)-expansion Method and The Tanh-Coth Function Method

Wazwaz [Appl. Math. Comput 195, 24-33 (2008)] has used the tanh-coth function method to find the solutions of the Pochhammer-Chree equation. In this article, we have applied the ((G'/G))-expansion method to solve the same equation. We have noted that both of these methods give the same solutions. Furthermore, we have shown in theorem 1, that the ((G'/G))-expansion method is equivalent to the tanh-coth function method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absorbance and fluorometric sensing with capillary wells microplates

Detection and readout from small volume assays in microplates are a challenge. The capillary wells microplate approach [Ng et al., Appl. Phys. Lett. 93, 174105 (2008)] offers strong advantages in small liquid volume management. An adapted design is described and shown here to be able to detect, in a nonimaging manner, fluorescence and absorbance assays minus the error often associated with meniscus forming at the air-liquid interface. The presence of bubbles in liquid samples residing in microplate wells can cause inaccuracies. Pipetting errors, if not adequately managed, can result in misleading data and wrong interpretations of assay results; particularly in the context of high throughput screening. We show that the adapted design is also able to detect for bubbles and pipetting errors during actual assay runs to ensure accuracy in screening.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Semianalytic model of electron pulse propagation: Magnetic lenses and rf pulse compression cavities

The analytical Gaussian electron pulse propagation model of Michalik and Sipe [J. Appl. Phys. 99, 054908 (2006)] is extended to include the action of external forces on the pulse. The resultant ability to simulate efficiently the effect of electron optical elements (e.g., magnetic lenses and radio-frequency cavities) allows for the rapid assessment of electron pulse delivery systems in time-resolved ultrafast electron diffraction and microscopy experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗