Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Symmetry requirements for double shell capsules with aluminum ablators

Double shell targets present a promising avenue to obtain robust neutron yield on current laser facilities. The nature of the target, like current single shell designs, requires a symmetric implosion of an outer ablator to obtain a symmetric fuel volume that will lead to alpha heating and thermonuclear burn. Due to using aluminum as an ablator material and requiring different convergence than single shell symmetry studies at various energies are required. This paper moves forward from previous experiments conducted at 1MJ to show implosion symmetry at 1.25 and 1.5MJ. Symmetry in these experiments is sufficient to merit experiments using double shells to study the platform further. Additional studies are carried out on the outer shell symmetry impacts, showing that mitigating mode growth on the outer ablator is of great importance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hypervelocity impact in stellar media: heat shielding, shock fronts and ablation clouds

The Frontier Plasma Science experiments proposed by our team will model the processes occurring during spacecraft atmospheric entries and meteorite planetary collisions by inserting material targets into the Scrape off Layer (SOL) and edge plasma of a tokamak. This project will investigate important plasma-material processes during high-enthalpy atmospheric entries, including heat flux generation and material ablation. Of particular interest is to explore heat and particle flux detachment in front of the sample using concepts and techniques developed in the latest studies of divertor detachment. Exploration missions to the Solar System’s gaseous giants and hyperbolic re-entries into the Earth’s atmosphere require spacecraft that can withstand high velocity (>10 km/s), high heat fluxes (>10 MW/m2), and corresponding enthalpies. Ablative materials have been used as thermal shields to protect the spacecraft from severe heating during entry. However, developing high enthalpy ablating materials is challenging due to the lack of adequate ground testing facilities. Our team stated that the performance of candidate shielding materials could be assessed in a laboratory environment with multiple in-situ diagnostics, which was enabled by the progress in the tokamak research. Modern machines feature relatively long discharges (~10 s) with well-controlled stable plasma conditions at the edge where the heat flux and the flow speed are similar to those experienced during atmospheric entries. The experiments were carried out at the DIII-D National Fusion Facility in San Diego, CA, operated by General Atomics (GA) for the DoE.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Safeguards Verification Measurements using Laser Ablation, Absorbance Ratio Spectrometry in Gaseous Centrifuge Enrichment Plants

Laser Ablation Absorbance Ratio Spectrometry (LAARS) is a new verification measurement technology under development at the US Department of Energy’s (DOE) Pacific Northwest National Laboratory (PNNL). LAARS uses three lasers to ablate and then measure the relative isotopic abundance of uranium compounds. An ablation laser is tightly focused on uranium-bearing solids producing a small plume containing uranium atoms. Two collinear wavelength-tuned spectrometry lasers transit through the plume and the absorbance of U-235 and U-238 isotopes are measured to determine U-235 enrichment. The measurement has high relative precision and detection limits approaching the femtogram range for uranium. It is independent of chemical form and degree of dilution with nuisance dust and other materials. High speed sample scanning and pinpoint characterization allow measurements on millions of particles/hour to detect and analyze the enrichment of trace uranium in samples. The spectrometer is assembled using commercially available components at comparatively low cost, and features a compact and low power design. Future designs can be engineered for reliable, autonomous deployment within an industrial plant environment. Two specific applications of the spectrometer are under development: 1) automated unattended aerosol sampling and analysis and 2) on-site small sample destructive assay measurement. The two applications propose game-changing technological advances in gaseous centrifuge enrichment plant (GCEP) safeguards verification. The aerosol measurement instrument, LAARS-environmental sampling (ES), collects aerosol particles from the plant environment in a purpose-built rotating drum impactor and then uses LAARS-ES to quickly scan the surface of the impactor to measure the enrichments of the captured particles. The current approach to plant misuse detection involves swipe sampling and offsite analysis. Though this approach is very robust it generally requires several months to obtain results from a given sample collection. The destructive assay instrument, LAARS-destructive assay (DA), uses a simple purpose-built fixture with a sampling planchet to collect adsorbed UF6 gas from a cylinder valve or from a process line tap or pigtail. A portable LAARS-DA instrument scans the microgram quantity of uranium collected on the planchet and the assay of the uranium is measured to ~0.15% relative precision. Currently, destructive assay samples for bias defect measurements are collected in small sample cylinders for offsite mass spectrometry measurement.

Enrichment Monitoring↗

Laser ablation for the synthesis of carbon nanotubes

Single walled carbon nanotubes are produced in a novel apparatus by the laser-induced ablation of moving carbon target. The laser used is of high average power and ultra-fast pulsing. According to various preferred embodiments, the laser produces and output above about 50 watts/cm.sup.2 at a repetition rate above about 15 MHz and exhibits a pulse duration below about 10 picoseconds. The carbon, carbon/catalyst target and the laser beam are moved relative to one another and a focused flow of "side pumped", preheated inert gas is introduced near the point of ablation to minimize or eliminate interference by the ablated plume by removal of the plume and introduction of new target area for incidence with the laser beam. When the target is moved relative to the laser beam, rotational or translational movement may be imparted thereto, but rotation of the target is preferred.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ablation of film stacks in solar cell fabrication processes

A dielectric film stack of a solar cell is ablated using a laser. The dielectric film stack includes a layer that is absorptive in a wavelength of operation of the laser source. The laser source, which fires laser pulses at a pulse repetition rate, is configured to ablate the film stack to expose an underlying layer of material. The laser source may be configured to fire a burst of two laser pulses or a single temporally asymmetric laser pulse within a single pulse repetition to achieve complete ablation in a single step.

36 MATERIALS SCIENCE↗

Safeguards Verification Measurements using Laser Ablation, Absorbance Ratio Spectrometry in Gaseous Centrifuge Enrichment Plants

Laser Ablation Absorbance Ratio Spectrometry (LAARS) is a new verification measurement technology under development at the US Department of Energy (DOE) Pacific Northwest National Laboratory (PNNL). LAARS uses three lasers to ablate and then measure the relative isotopic abundance of uranium compounds. An ablation laser is tightly focused on uranium-bearing solids, producing a small atomic uranium vapor plume. Two collinear wavelength-tuned spectrometry lasers transit through the plume and the absorbance of U-235 and U-238 isotopes are measured to determine U-235 enrichment. The measurement is independent of chemical form and degree of dilution with nuisance dust and other materials. LAARS has high relative precision and detection limits approaching the femtogram range for U-235. The sample is scanned and assayed point-by-point at rates reaching 1 million measurements/hour, enabling LAARS to detect and analyze uranium in trace samples. The spectrometer is assembled using primarily commercially available components and features a compact design and automated analysis.Two specific gaseous centrifuge enrichment plant (GCEP) applications of the spectrometer are currently under development: 1) LAARS-Environmental Sampling (ES), which collects and analyzes aerosol particles for GCEP misuse detection and 2) LAARS-Destructive Assay (DA), which enables onsite enrichment DA sample collection and analysis for protracted diversion detection. The two applications propose game-changing technological advances in GCEP safeguards verification.

Uranium Enrichment Laser Safeguards↗

Experiments to measure ablative Richtmyer-Meshkov growth of Gaussian bumps in plastic capsules

Growth of hydrodynamic instabilities at the interfaces of inertial confinement fusion capsules (ICF) due to ablator and fuel non-uniformities have been of primary concern to the ICF program since its inception. To achieve thermonuclear ignition at Megajoule class laser systems such as the NIF, targets must be designed for high implosion velocities, which requires higher in-flight aspect ratios (IFAR) and diminished shell stability. Controlling capsule perturbations is thus of the utmost importance. Recent simulations have shown that features on the outer surface of an ICF capsule as small as 10 microns wide and 100's of nanometers tall such as bumps, divots, or even dust particles can profoundly impact capsule performance by leading to material jetting or mix into the hotspot. Recent x-ray images of implosions on the NIF may be evidence of such mixing. Unfortunately, our ability to accurately predict these effects is uncertain due to disagreement between equation of state (EOS) models. In light of this, we have begun a campaign to measure the growth of isolated defects (Gaussian bumps) due to ablative Richtmyer-Meshkov in CH capsules to validate these models. The platform that has been developed uses halfraums with radiation temperatures near 75 eV (Rev. 4 foot-level) driven by 15-20 beams from the Omega laser (Laboratory for Laser Energetics, University of Rochester, NY), which sends a ~2.5 Mbar shock into a planar CH foil. Gaussian-shaped bumps (20 microns wide, 4-7 microns tall) are deposited onto the ablation side of the target. On-axis radiography with a saran (Cl He α - 2.8 keV) backlighter is used to measure bump evolution prior to shock breakout. Shock speed measurements will also be made with Omega's active shock breakout (ASBO) and streaked optical pyrometery (SOP) diagnostics in conjunction with filtered x-ray photodiode arrays (DANTE) to determine drive conditions in the target. These data will be used to discriminate between EOS models so that one may be selected to design the shape and intensity of the foot in an ignition-level drive pulse so that bump amplitude is minimized by the time the shell begins to accelerate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser ablation for the synthesis of carbon nanotubes

Single walled carbon nanotubes are produced in a novel apparatus by the laser-induced ablation of moving carbon target. The laser used is of high average power and ultra-fast pulsing. According to various preferred embodiments, the laser produces an output above about 50 watts/cm 2 at a repetition rate above about 15 MHz and exhibits a pulse duration below about 10 picoseconds. The carbon, carbon/catalyst target and the laser beam are moved relative to one another and a focused flow of "side pumped", preheated inert gas is introduced near the point of ablation to minimize or eliminate interference by the ablated plume by removal of the plume and introduction of new target area for incidence with the laser beam. When the target is moved relative to the laser beam, rotational or translational movement may be imparted thereto, but rotation of the target is preferred.

36 MATERIALS SCIENCE↗

Plastic ablator ignition capsule design for the National Ignition Facility

The National Ignition Campaign, tasked with designing and fielding targets for fusion ignition experiments on the National Ignition Facility (NIF), has carried forward three complementary target designs for the past several years: a beryllium ablator design, a plastic ablator design, and a high-density carbon or synthetic diamond design. This paper describes current simulations and design optimization to develop the plastic ablator capsule design as a candidate for the first ignition attempt on NIF. The trade-offs in capsule scale and laser energy that must be made to achieve a comparable ignition probability to that with beryllium are emphasized. Large numbers of 1-D simulations, meant to assess the statistical behavior of the target design, as well as 2-D simulations to assess the target's susceptibility to Rayleigh-Taylor growth are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond filament-laser ablation molecular isotopic spectrometry

A new remote sensing technology for real-time isotopic analysis is introduced: Femtosecond Filament-Induced Laser Ablation Molecular Isotopic Spectrometry (F 2 -LAMIS). The technique combines femtosecond (fs) laser filamentation and ablation-based molecular isotopic spectroscopy, thereby enabling isotopic analysis of samples at a distance, in ambient air and at ambient pressure conditions. Isotopic analysis of zirconium (Zr) samples by F 2 -LAMIS is demonstrated, and the molecular and atomic emission intensity, and properties of the filament-induced plasma generated at different filament propagation distances were investigated. Spectral fitting of F 2 -LAMIS spectra enabled semi-quantitative isotopic analysis without the use of calibration standards, which was independent of the filament propagation distance for the studied range. As a result, this technology provides new capabilities for direct isotopic ratio measurements at remote distances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser ablation of polymers: a review

Laser ablation (LA), which employs a pulsed laser to remove materials from a substrate for generating micro-/nanostructures, has tremendous applications in the fabrication of metals, ceramics, glasses and polymers. It has become a noteworthy approach for achieving various functional structures in engineering, chemistry, biology, medicine and other fields. Polymers are one such class of materials; they can be melted and vaporized at high temperature during the ablation process. A number of polymers have been researched as candidate substrates in LA, and many different structures and patterns have been realized by this method. The current states of research and progress are reviewed from basic concepts to optimal parameters, polymer types and applications. Additionally, the significance of this paper is to provide a basis for follow-up research that leads to the development of superior materials and high-quality production through LA. In this review, we first introduce the basic concept of LA, including mechanism, laser types (millisecond, microsecond, nanosecond, picosecond and femtosecond) and influential parameters (wavelength, repetition rate, fluence and pulse duration). Then, we focus on several commonly used polymer materials and compare them in detail, including the effects of polymer properties, laser parameters and feature designs. Finally, we summarize the applications of various structures fabricated by LA in a variety of areas along with a perspective of the challenges in this research area. Overall, a thorough review of LA of several polymers is presented, which could pave the way for characterization of future novel materials.

36 MATERIALS SCIENCE↗

The effect of tumor size and location on efficacy and safety of US- and CT- guided percutaneous microwave ablation in renal cell carcinomas

Purpose: To evaluate the effect of size and central location of the tumor on safety and efficacy of percutaneous CEUS- and CT-guided MWA in biopsy-proven renal cell carcinomas (RCCs). Materials and methods: In this IRB-approved retrospective study, 69 biopsy-proven renal tumors in 56 patients, who underwent MWA in our institution from January 2013 to March 2017, were evaluated. Data collection included demographics, tumor characteristics, procedural protocols, and follow-up visits within 6 months post procedure. Primary outcomes were assessed by technical success (TS), local tumor progression (LTP), and complications. The Kaplan–Meier analysis was used for survival rate. Results: Overall technical success was achieved for all 69 lesions (92.8% primary TS, 100% overall). Median nephrometry score was 8 (4–11) and median tumor size was 2.5 cm (0.8–7). Five lesions which required second ablation had significantly higher median tumor size 4 cm (P = 0.039) with the same nephrometry score. Renal function remained stable with no significant change in eGFR before or after ablation. The LTP rate was 5.8%. The most recurrent tumors were clear cell (50%) followed by papillary tumors (25%). The complication rate was 5.8% with minor complications (hematoma and pain) and no major issues. There was no significant association between nephrometry score and technical success, recurrence, or complication rates. Overall and tumor-specific survival rates were 96.7% and 100% at 11.9 months. Conclusions: Image-guided MWA appears to be a safe and effective treatment regardless of nephrometry score and tumor location with high technical success, low recurrence, and complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined MRI and Fluoroscopic Guided Radiofrequency Ablation of a Renal Tumor

Percutaneous CT- and ultrasound-guided radiofrequency ablation of renal cell carcinoma (RCC) has been shown to have very promising medium-term results. We present a unique case of recurrent RCC after partial nephrectomy in a patient with a single kidney and impaired renal function. This tumor could not be visualized either with CT or with ultrasound. A combination of magnetic resonance imaging and fluoroscopic guidance was used, to the best of our knowledge for the first time, to ablate the tumor with radiofrequency. The patient was cancer-free and off dialysis at 30-month follow up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Radiofrequency Ablation of Lung Tumors in Contact with the Aorta: Dangerous and Difficult but Efficient: A Report of Two Cases

Percutaneous imaging-guided tumor ablation is a widely accepted method for the treatment of primary and secondary lung tumors. Although it is generally feasible and effective for local tumor control, some conditions may affect its feasibility and effectiveness. Herein the authors report their experience with two patients with lung malignancies contiguous to the aorta who were successfully treated with radiofrequency ablation, even though it initially appeared highly risky due to the possible fatal complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Thermal Ablation Using Ferrofluids: Influence of Administration Mode on Biological Effect in Different Porcine Tissues

The purpose of this study was to compare the effects of magnetic thermal ablation in different porcine tissues using either a singular injection or a continuous infusion of superparamagnetic iron oxide nanoparticles. In the first setting samples of three ferrofluids containing different amounts of iron (1:171, 2:192, and 3:214 mg/ml) were singularly interstitially injected into specimens of porcine liver, kidney, and muscle (n = 5). Then the specimens were exposed to an alternating magnetic field (2.86 kA/m, 190 kHz) generated by a circular coil for 5 min. In the second experimental setup ferrofluid samples were continuously interstitially infused into the tissue specimens during the exposure to the magnetic field. To measure the temperature increase two fiber-optic temperature probes with a fixed distance of 0.5 cm were inserted into the specimens along the puncture tract of the injection needle and the temperature was measured every 15 s. Finally, the specimens were dissected, the diameters of the created thermal lesions were measured, and the volumes were calculated and compared. Compared to continuous infusion, a single injection of ferrofluids resulted in smaller coagulation volumes in all tissues. Significant differences regarding coagulation volume were found in kidney and muscle specimens. The continuous infusion technique led to more elliptically shaped coagulation volumes due to larger diameters along the puncture tract. Our data show the feasibility of magnetic thermal ablation using either a single interstitial injection or continuous infusion for therapy of lesions in muscle, kidney, and liver. Continuous infusion of ferrofluids results in larger zones of necrosis compared to a single injection technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Massive Hemoptysis from Pulmonary Artery Pseudoaneurysm Caused by Lung Radiofrequency Ablation: Successful Treatment by Coil Embolization

A 75-year-old man received lung radiofrequency (RF) ablation to treat lung metastases from hepatocellular carcinoma. Massive hemoptysis occurred 1 week after lung RF ablation. Emergent contrast-enhanced CT and pulmonary arteriography revealed a pulmonary artery pseudoaneurysm, which was embolized with coils. The postembolization course was uneventful. Hemoptysis did not recur for 5 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Antenna Microwave Ablation Under Contrast-Enhanced Ultrasound Guidance for Treatment of Small Renal Cell Carcinoma: Preliminary Experience

The purpose of this study was to determine the safety, effectiveness, and feasibility of microwave ablation (MWA) of small renal cell carcinomas (RCCs) in selected patients. Institutional review board and informed consent were obtained. From December 2007 to January 2009, 12 patients (8 male, 4 female) were enrolled in a treatment group, in which percutaneous MWA of small RCCs was performed under contrast-enhanced ultrasound guidance. The tumors were 1.7-2.9 cm in diameter (mean diameter, 2.0 cm).Therapeutic effects were assessed at follow-up with computed tomography. All patients were followed up for 3-14 months (mean, 6 months) to observe the therapeutic effects and complications (according to SIR classification). Assessment was carried out with CT imaging. No severe complications or unexpected side effects were observed after the MWA procedures. In all cases technical success was achieved. Clinical effectiveness was 100%; none of the patients showed recurrence on imaging. In conclusion, our preliminary results support the use of MWA for the treatment of small renal tumors. This technology can be applied in select patients who are not candidates for surgery, as an alternative to other ablative techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Renal Ablation for Life-Threatening Hemorrhage from Multiple Capsular Branches During Renal Artery Stenting

A 55-year-old woman underwent bilateral renal artery stent placement with good angiographic result. After the procedure, the patient complained of left flank pain secondary to subcapsular hematoma. Retrospective evaluation of images taken during stent implantation favored the diagnosis of guidewire perforation. Three hours after the procedure, contrast-enhanced computed tomography and subsequent renal angiography showed multifocal extravasations. We performed emergent renal ablation for the treatment of massive bleeding. To our knowledge, this is the first use of transcatheter renal ablation technique for this purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗