Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “02 - PETROLEUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Accuracy of Tau Positron Emission Tomography as a Prognostic Marker in Preclinical and Prodromal Alzheimer Disease: A Head-to-Head Comparison Against Amyloid Positron Emission Tomography and Magnetic Resonance Imaging

Importance: Tau positron emission tomography (PET) tracers have proven useful for the differential diagnosis of dementia, but their utility for predicting cognitive change is unclear. Objective: To examine the prognostic accuracy of baseline fluorine 18 ( 18 F)-flortaucipir and [18F]RO948 (tau) PET in individuals across the Alzheimer disease (AD) clinical spectrum and to perform a head-to-head comparison against established magnetic resonance imaging (MRI) and amyloid PET markers. Design, setting, and participants: This prognostic study collected data from 8 cohorts in South Korea, Sweden, and the US from June 1, 2014, to February 28, 2021, with a mean (SD) follow-up of 1.9 (0.8) years. A total of 1431 participants were recruited from memory clinics, clinical trials, or cohort studies; 673 were cognitively unimpaired (CU group; 253 [37.6%] positive for amyloid-β [Aβ]), 443 had mild cognitive impairment (MCI group; 271 [61.2%] positive for Aβ), and 315 had a clinical diagnosis of AD dementia (315 [100%] positive for Aβ). Exposures: [ 18 F]Flortaucipir PET in the discovery cohort (n = 1135) or [ 18 F]RO948 PET in the replication cohort (n = 296), T1-weighted MRI (n = 1431), and amyloid PET (n = 1329) at baseline and repeated Mini-Mental State Examination (MMSE) evaluation. Main outcomes and measures: Baseline [ 18 F]flortaucipir/[ 18 F]RO948 PET retention within a temporal region of interest, MRI-based AD-signature cortical thickness, and amyloid PET Centiloids were used to predict changes in MMSE using linear mixed-effects models adjusted for age, sex, education, and cohort. Mediation/interaction analyses tested whether associations between baseline tau PET and cognitive change were mediated by baseline MRI measures and whether age, sex, and APOE genotype modified these associations. Results: Among 1431 participants, the mean (SD) age was 71.2 (8.8) years; 751 (52.5%) were male. Findings for [ 18 F]flortaucipir PET predicted longitudinal changes in MMSE, and effect sizes were stronger than for AD-signature cortical thickness and amyloid PET across all participants (R 2 , 0.35 [tau PET] vs 0.24 [MRI] vs 0.17 [amyloid PET]; P < .001, bootstrapped for difference) in the Aβ-positive MCI group (R2, 0.25 [tau PET] vs 0.15 [MRI] vs 0.07 [amyloid PET]; P < .001, bootstrapped for difference) and in the Aβ-positive CU group (R 2 , 0.16 [tau PET] vs 0.08 [MRI] vs 0.08 [amyloid PET]; P < .001, bootstrapped for difference). These findings were replicated in the [ 18 F]RO948 PET cohort. MRI mediated the association between [ 18 F]flortaucipir PET and MMSE in the groups with AD dementia (33.4% [95% CI, 15.5%-60.0%] of the total effect) and Aβ-positive MCI (13.6% [95% CI, 0.0%-28.0%] of the total effect), but not the Aβ-positive CU group (3.7% [95% CI, -17.5% to 39.0%]; P = .71). Age (t = -2.28; P = .02), but not sex (t = 0.92; P = .36) or APOE genotype (t = 1.06; P = .29) modified the association between baseline [ 18 F]flortaucipir PET and cognitive change, such that older individuals showed faster cognitive decline at similar tau PET levels. Conclusions and relevance: The findings of this prognostic study suggest that tau PET is a promising tool for predicting cognitive change that is superior to amyloid PET and MRI and may support the prognostic process in preclinical and prodromal stages of AD.

59 BASIC BIOLOGICAL SCIENCES↗

Tau Positron Emission Tomography for Predicting Dementia in Individuals With Mild Cognitive Impairment

An accurate prognosis is especially pertinent in mild cognitive impairment (MCI), when individuals experience considerable uncertainty about future progression. To evaluate the prognostic value of tau positron emission tomography (PET) to predict clinical progression from MCI to dementia. This was a multicenter cohort study with external validation and a mean (SD) follow-up of 2.0 (1.1) years. Data were collected from centers in South Korea, Sweden, the US, and Switzerland from June 2014 to January 2024. Participant data were retrospectively collected and inclusion criteria were a baseline clinical diagnosis of MCI; longitudinal clinical follow-up; a Mini-Mental State Examination (MMSE) score greater than 22; and available tau PET, amyloid-β (Aβ) PET, and magnetic resonance imaging (MRI) scan less than 1 year from diagnosis. A total of 448 eligible individuals with MCI were included (331 in the discovery cohort and 117 in the validation cohort). None of these participants were excluded over the course of the study. Exposures included Tau PET, Aβ PET, and MRI. Positive results on tau PET (temporal meta–region of interest), Aβ PET (global; expressed in the standardized metric Centiloids), and MRI (Alzheimer disease [AD] signature region) was assessed using quantitative thresholds and visual reads. Clinical progression from MCI to all-cause dementia (regardless of suspected etiology) or to AD dementia (AD as suspected etiology) served as the primary outcomes. The primary analyses were receiver operating characteristics. In the discovery cohort, the mean (SD) age was 70.9 (8.5) years, 191 (58%) were male, the mean (SD) MMSE score was 27.1 (1.9), and 110 individuals with MCI (33%) converted to dementia (71 to AD dementia). Only the model with tau PET predicted all-cause dementia (area under the receiver operating characteristic curve [AUC], 0.75; 95% CI, 0.70-0.80) better than a base model including age, sex, education, and MMSE score (AUC, 0.71; 95% CI, 0.65-0.77; P = .02), while the models assessing the other neuroimaging markers did not improve prediction. In the validation cohort, tau PET replicated in predicting all-cause dementia. Compared to the base model (AUC, 0.75; 95% CI, 0.69-0.82), prediction of AD dementia in the discovery cohort was significantly improved by including tau PET (AUC, 0.84; 95% CI, 0.79-0.89; P < .001), tau PET visual read (AUC, 0.83; 95% CI, 0.78-0.88; P = .001), and Aβ PET Centiloids (AUC, 0.83; 95% CI, 0.78-0.88; P = .03). In the validation cohort, only the tau PET and the tau PET visual reads replicated in predicting AD dementia. In this study, tau-PET showed the best performance as a stand-alone marker to predict progression to dementia among individuals with MCI. This suggests that, for prognostic purposes in MCI, a tau PET scan may be the best currently available neuroimaging marker.

59 BASIC BIOLOGICAL SCIENCES↗

Energy limits of electron acceleration in the plasma sheet during substorms: A case study with the Magnetospheric Multiscale (MMS) mission

Here, we present multipoint observations of earthward moving dipolarization fronts and energetic particle injections from NASA's Magnetospheric Multiscale mission with a focus on electron acceleration. From a case study during a substorm on 02 August 2015, we find that electrons are only accelerated over a finite energy range, from a lower energy threshold at ~7–9 keV up to an upper energy cutoff in the hundreds of keV range. At energies lower than the threshold energy, electron fluxes decrease, potentially due to precipitation by strong parallel electrostatic wavefields or initial sources in the lobes. Electrons at energies higher than the threshold are accelerated cumulatively by a series of impulsive magnetic dipolarization events. This case demonstrates how the upper energy cutoff increases, in this case from ~130 keV to >500 keV, with each dipolarization/injection during sustained activity. We also present a simple model accounting for these energy limits that reveals that electron energization is dominated by betatron acceleration.

58 GEOSCIENCES↗

Spatiotemporal Changes in Trace Metal Bioavailability in the Sediment Pore water of a Constructed Wetland Using Passive Pore water Samplers

Sediments in aquatic systems often act as a major sink for contaminants. Diffusive gradient in thin films (DGTs) and in situ equilibrium dialysis samplers (peepers) are two major in situ pore water sampling devices that overcome the problems associated with conventional pore water sampling methods. In the present study, DGTs and peepers were used to study the spatial and seasonal effects (cool months, October–February; warm months, May–September) on metal bioavailability in the H‐02 constructed wetland and the sink versus source role of the sediments by calculating the metal resupply capacity. Data showed similar seasonal trends in metal concentrations using passive samplers, peepers, and DGTs. Pooled Cu and Zn concentrations measured using DGTs were lower in warm months (1.67 ± 1.50 and 2.62 ± 0.68 μg L –1 , respectively, p < 0.001) versus in cool months (2.12 ± 0.65 and 5.58 ± 1.33 μg L –1 , respectively, p < 0.001; mean ± 95% confidence interval). Sulfate (SO 4 2− ) concentrations were significantly (p = 0.0139) lower in warm months (averaged at 0.22 ± 0.05 mg L –1 ) compared to in cool months (0.16 ± 0.05 mg L –1 ). The increase in SO 4 2− concentration is an indicator of the lower activity of sulfate‐reducing bacteria, which need SO 4 2− during anaerobic respiration, in which SO 4 2− is reduced to sulfide (S 2– ) that forms insoluble salts with Cu and Zn, which could partially explain the higher bioavailability of these metals in the cool season. Metal resupply capacity of the sediments was mostly <0.2 for Cu and Zn. Taken together, the H0‐2 wetland sediments mostly acted as a sink to both Cu and Zn over the course of the present study. Environ Toxicol Chem 2023;42:2726–2736. © 2023 The Authors. Environmental Toxicology and Chemistry published by Wiley Periodicals LLC on behalf of SETAC.

54 ENVIRONMENTAL SCIENCES↗

Centrality dependence of J /ψ and ψ (2S) production and nuclear modification in p-Pb collisions at \( \sqrt{s_{\mathrm{NN}}} \) = 8 . 16 TeV

The inclusive production of the J/ ψ and ψ (2S) charmonium states is studied as a function of centrality in p-Pb collisions at a centre-of-mass energy per nucleon pair \( \sqrt{s_{\mathrm{NN}}} \) = 8 . 16 TeV at the LHC. The measurement is performed in the dimuon decay channel with the ALICE apparatus in the centre-of-mass rapidity intervals – 4 . 46 < y cms < – 2 . 96 (Pb-going direction) and 2 . 03 < y cms < 3 . 53 (p-going direction), down to zero transverse momentum ( p T ). The J/ ψ and ψ (2S) production cross sections are evaluated as a function of the collision centrality, estimated through the energy deposited in the zero degree calorimeter located in the Pb-going direction. The p T -differential J/ ψ production cross section is measured at backward and forward rapidity for several centrality classes, together with the corresponding average \( \left\langle {p}_{\mathrm{T}}\right\rangle \) and \( \left\langle {p}_{\mathrm{T}}^2\right\rangle \) values. The nuclear effects affecting the production of both charmonium states are studied using the nuclear modification factor. In the p-going direction, a suppression of the production of both charmonium states is observed, which seems to increase from peripheral to central collisions. In the Pb-going direction, however, the centrality dependence is different for the two states: the nuclear modification factor of the J/ ψ increases from below unity in peripheral collisions to above unity in central collisions, while for the ψ (2S) it stays below or consistent with unity for all centralities with no significant centrality dependence. The results are compared with measurements in p-Pb collisions at \( \sqrt{s_{\mathrm{NN}}} \) = 5 . 02 TeV and no significant dependence on the energy of the collision is observed. Finally, the results are compared with theoretical models implementing various nuclear matter effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Predictions for boson-jet observables and fragmentation function ratios from a hybrid strong/weak coupling model for jet quenching

We have previously introduced a hybrid strong/weak coupling model for jet quenching in heavy ion collisions in which we describe the production and fragmentation of jets at weak coupling, using Pythia, and describe the rate at which each parton in the jet shower loses energy as it propagates through the strongly coupled plasma, dE/dx, using an expression computed holographically at strong coupling. The model has a single free parameter that we fit to a single experimental measurement. We then confront our model with experimental data on many other jet observables, focusing in this paper on boson-jet observables, finding that it provides a good description of present jet data. Next, we provide the predictions of our hybrid model for many measurements to come, including those for inclusive jet, dijet, photon-jet and Z-jet observables in heavy ion collisions with energy √s = 5 : 02 ATeV coming soon at the LHC. As the statistical uncertainties on near-future measurements of photon-jet observables are expected to be much smaller than those in present data, with about an order of magnitude more photon-jet events expected, predictions for these observables are particularly important. We find that most of our pre- and post-dictions do not depend sensitively on the form we choose for the rate of energy loss dE/dx of the partons in the shower. This gives our predictions considerable robustness. To better discriminate between possible forms for the rate of energy loss, though, we must turn to intrajet observables. Here, we focus on ratios of fragmentation functions. Finally, we close with a suggestion for a particular ratio, between the fragmentation functions of inclusive and associated jets with the same kinematics in the same collisions, which is particularly sensitive to the x- and E-dependence of dE/dx, and hence may be used to learn which mechanism of parton energy loss best describes the quenching of jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bottomonium suppression and elliptic flow using Heavy Quarkonium Quantum Dynamics

We introduce a framework called Heavy Quarkonium Quantum Dynamics (HQQD) which can be used to compute the dynamical suppression of heavy quarkonia propagating in the quark-gluon plasma using real-time in-medium quantum evolution. Using HQQD we compute large sets of real-time solutions to the Schrödinger equation using a realistic in-medium complex-valued potential. We sample 2 million quarkonia wave packet trajectories and evolve them through the QGP using HQQD to obtain their survival probabilities. The computation is performed using three different HQQD model parameter sets in order to estimate our systematic uncertainty. After taking into account final state feed down we compare our results to existing experimental data for the suppression and elliptic flow of bottomonium states and find that HQQD predictions are good agreement with available data for R AA as a function of N part and p T collected at \( \sqrt{s_{\mathrm{NN}}} \) = 5 . 02 TeV. In the case of v 2 for the various states, we find that the path-length dependence of ϒ(1 s ) suppression results in quite small v 2 for ϒ(1 s ). Our prediction for the integrated elliptic flow for ϒ(1 s ) in the 10 – 90% centrality class, which now includes an estimate of the systematic error, is v 2 [ϒ(1 s )] = 0 . 003 ± 0 . 0007 ± \( {}_{0.0013}^{0.0006} \) . We also find that, due to their increased suppression, excited bottomonium states have a larger elliptic flow. Based on this observation we make predictions for v 2 [ϒ(2 s )] and v 2 [ϒ(3 s )] as a function of centrality and transverse momentum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Azimuthal anisotropy of dijet events in PbPb collisions at $$ \sqrt{s_{\textrm{NN}}} $$ = 5.02 TeV

A bstract The path-length dependent parton energy loss within the dense partonic medium created in lead-lead collisions at a nucleon-nucleon center-of-mass energy of $$ \sqrt{s_{\textrm{NN}}} $$ s NN = 5 . 02 TeV is studied by determining the azimuthal anisotropies for dijets with high transverse momentum. The data were collected by the CMS experiment in 2018 and correspond to an integrated luminosity of 1.69 nb − 1 . For events containing back-to-back jets, correlations in relative azimuthal angle and pseudorapidity ( η ) between jets and hadrons, and between two hadrons, are constructed. The anisotropies are expressed as the Fourier expansion coefficients v n , n = 2–4 of these azimuthal distributions. The dijet v n values are extracted from long-range (1 . 5 < |∆ η | < 2 . 5) components of these correlations, which suppresses the background contributions from jet fragmentation processes. Positive dijet v 2 values are observed which increase from central to more peripheral events, while the v 3 and v 4 values are consistent with zero within experimental uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Z-boson production in p-Pb collisions at $ \sqrt{s_{\mathrm{NN}}} $ = 8.16 TeV and Pb-Pb collisions at $ \sqrt{s_{\mathrm{NN}}} $ = 5.02 TeV

Measurement of Z-boson production in p-Pb collisions at $ \sqrt{s_{\mathrm{NN}}} $ = 8 . 16 TeV and Pb-Pb collisions at $ \sqrt{s_{\mathrm{NN}}} $ = 5 . 02 TeV is reported. It is performed in the dimuon decay channel, through the detection of muons with pseudorapidity - 4 < η μ < - 2 . 5 and transverse momentum $ {p}_{\mathrm{T}}^{\mu } $ > 20 GeV/ c in the laboratory frame. The invariant yield and nuclear modification factor are measured for opposite-sign dimuons with invariant mass 60 < m μμ < 120 GeV/ c 2 and rapidity 2 . 5 < $ {y}_{\mathrm{cms}}^{\mu \mu} $ < 4. They are presented as a function of rapidity and, for the Pb-Pb collisions, of centrality as well. The results are compared with theoretical calculations, both with and without nuclear modifications to the Parton Distribution Functions (PDFs). In p-Pb collisions the center-of-mass frame is boosted with respect to the laboratory frame, and the measurements cover the backward ( - 4 . 46 < $ {y}_{\mathrm{cms}}^{\mu \mu} $ < - 2 . 96) and forward (2 . 03 < $ {y}_{\mathrm{cms}}^{\mu \mu} $ < 3 . 53) rapidity regions. For the p-Pb collisions, the results are consistent within experimental and theoretical uncertainties with calculations that include both free-nucleon and nuclear-modified PDFs. For the Pb-Pb collisions, a 3 . 4 σ deviation is seen in the integrated yield between the data and calculations based on the free-nucleon PDFs, while good agreement is found once nuclear modifications are considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Jet fragmentation transverse momentum distributions in pp and p-Pb collisions at $ \sqrt{s}$, $\sqrt{s_{\mathrm{NN}}}$ = 5.02 TeV

Jet fragmentation transverse momentum ( j T ) distributions are measured in proton-proton (pp) and proton-lead (p-Pb) collisions at s NN = 5 . 02 TeV with the ALICE experiment at the LHC. Jets are reconstructed with the ALICE tracking detectors and electromagnetic calorimeter using the anti- k T algorithm with resolution parameter R = 0 . 4 in the pseudorapidity range |η| < 0 . 25. The j T values are calculated for charged particles inside a fixed cone with a radius R = 0 . 4 around the reconstructed jet axis. The measured j T distributions are compared with a variety of parton-shower models. Herwig and P ythia 8 based models describe the data well for the higher j T region, while they underestimate the lower j T region. The j T distributions are further characterised by fitting them with a function composed of an inverse gamma function for higher j T values (called the “wide component”), related to the perturbative component of the fragmentation process, and with a Gaussian for lower j T values (called the “narrow component”), predominantly connected to the hadronisation process. The width of the Gaussian has only a weak dependence on jet transverse momentum, while that of the inverse gamma function increases with increasing jet transverse momentum. For the narrow component, the measured trends are successfully described by all models except for Herwig. For the wide component, Herwig and PYTHIA 8 based models slightly underestimate the data for the higher jet transverse momentum region. These measurements set constraints on models of jet fragmentation and hadronisation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Distal Edge Stenosis After Stent Placement for Isolated Superior Mesenteric Artery Dissection: Mechanisms and Risk Factor Analysis

Purpose: To analyze factors potentially associated with the occurrence of distal edge stenosis after stent placement for isolated superior mesenteric artery dissection (ISMAD). Materials and Methods: Cases of consecutive patients who were diagnosed with spontaneous ISMAD between February 2010 and July 2018 were retrospectively identified. Of the 123 cases identified, 45 patients (42 men; three women) underwent endovascular stent placement and were included in the study. Univariate and multivariate analyses were used to assess factors potentially associated with distal edge stenosis. Results: The technical success rate among study patients was 100%. During 26.7 ± 17.3 months of follow-up, CT angiography demonstrated good distal edge patency in 25 patients (55.6%) and evidence of distal edge stenosis in 20 patients (44.4%). In univariate analysis, stent length (odds radio [OR] 1.03; 95% confidence interval [CI] 1.01, 1.06; P = .02), stent-to-vessel (S/V) diameter ratio (OR 2.27; 95% CI 1.35, 3.82; P < .01), and angulation at the distal edge (OR 1.05; 95% CI 1.00, 1.10; P =.03) were significantly associated with distal edge stenosis; only S/V diameter ratio (OR 3.36; 95% CI 1.41, 7.99; P < .01) and angulation at the distal edge (OR 1.12; 95% CI 1.01, 1.23; P =.03) retained this significance in multivariate analysis. Conclusions: Distal edge stenosis after stent placement for ISMAD is common. S/V diameter ratio and angulation at the distal edge are independent risk factors for distal edge stenosis in patients with ISMAD who undergo stent placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast myocardial perfusion imaging with {sup 99m}Tc in challenging patients using conventional SPECT cameras

Background: We attempted to validate the performance of a fast myocardial perfusion imaging (MPI) protocol in diagnostically challenging patients. Methods: 78 patients with ΒΜΙ > 24.9, LVH or three vessels disease underwent two sequential gated-MPI studies. The first at 15 (Early Imaging, EI) and the second at 45 (Late Imaging, LI) minutes post {sup 99m}Tc-injection, at both stress and rest. Counts over heart (H), liver (Liv) and subdiaphragmatic space (Sub) and image quality, and myocardial perfusion and function parameters were compared between the two protocols. Coronary angiography was performed within 2 months from MPI, and ROC analysis was used to compare the diagnostic accuracy for the detection of ≥50% diameter luminal stenosis. Results: Quality was optimal-good in 93% of EI and 98% of LI studies (P = .12), H/Liv and stress H/Sub ratios were similar, but rest H/Sub ratio was lower in EI (P = .009). SSS [10 (0 to 46) vs 9 (0 to 36), P = .006] and SDS [3 (0 to 35) vs 2 (0 to 34), P = .02] were higher in EI protocol. LVEF, motion and thickening scores did not differ between the two protocols. A highly significant (P < .001) linear relationship with clinically negligible mean differences in Bland-Altman analysis was observed for all perfusion and function-related data. Sensitivity (EI 81%, LI 80%) and specificity (65% for both) did not differ (P = .23) between the two protocols. Conclusion: The fast protocol is technically feasible and diagnostically accurate compared to the established protocol in diagnostically challenging patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adenosine stress myocardial perfusion imaging in octogenarians: Safety, tolerability, and long-term prognostic implications of hemodynamic response and SPECT-related variables

Background: Evaluation of tolerability, safety, and prognostic implications of adenosine stress myocardial perfusion imaging (MPI) in octogenarians. Methods: 370 octogenarians (49% known coronary artery disease) were studied. Hemodynamic response, MPI-related data, and rest-left ventricular ejection fraction (LVEF) based on echocardiography were registered per patient, and prospective follow-up was performed to document all-cause death (ACD), cardiac death (CD), myocardial infarction (MI), and late revascularization. Results: No deaths or MIs were observed during adenosine infusion or the short-term post-infusion period. 86% of patients were able to tolerate a 6-minute infusion. All side effects terminated spontaneously after infusion cessation, except for one case of pulmonary oedema. After 9.3 years, there were 124 ACDs, 62 CDs, 16 MIs, and 35 revascularizations. Differences between survival curves of summed stress score (SSS)-based risk groups were significant for all end points (P < .001). SSS and LVEF were independent predictors of all end points (P ≤ .01) and lung uptake of cardiac end points. ΔHR <10 bpm (OR = 1.78, P = .004) and inability to increase HR by >10 bpm and decrease systolic blood pressure by >10 mmHg (OR = 2, P = .02) during adenosine infusion were independent predictors of ACD and CD, respectively. Hemodynamic response variables, SSS, and lung uptake provided incremental prognostic value over pre-test data for ACD and CD. Conclusions: In octogenarians, adenosine stress MPI is well tolerated and provides effective long-term risk stratification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of cardiac resynchronization therapy on right ventricular function during rest and exercise, as assessed by radionuclide angiography, and on NT-proBNP levels

Aim: We carried out this study to investigate mid-term effects of cardiac resynchronization therapy (CRT) on right ventricular (RV) function and neurohormonal response, expressed by N-terminal pro-brain natriuretic peptide (NT-proBNP), in heart failure patients stratified by baseline RV ejection fraction (RVEF). Methods and Results: Thirty-six patients with nonischemic dilated cardiomyopathy underwent technetium-99m radionuclide angiography with bicycle exercise immediately after CRT implantation (during spontaneous rhythm and after CRT activation) and 3 months later. Plasma NT proBNP was assessed before implantation and after 3 months. At baseline, RVEF was impaired (≤35%) in 14 patients, preserved (>35%) in 22. At 3 months, RVEF improved during rest and exercise (P = .02) in patients with impaired RV function, while remaining unchanged in patients with preserved RV function. Rest and exercise RV dyssynchrony decreased in both groups at follow-up (P < .05). A similar mid-term improvement in left ventricular (LV) function and NT-proBNP was observed in patients with impaired and preserved RVEF. In the former, the decrease in NT-proBNP correlated with the improvements both in LV and RV dyssynchrony and functions. Conclusion: CRT may improve RV performance, during rest and exercise, and neurohormonal response in heart failure patients with nonischemic dilated cardiomyopathy and baseline RV dysfunction. RV dysfunction should not be considered per se a primary criterion for excluding candidacy to CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient sensitivity analysis of the thermal profile in powder bed fusion of metals using hypercomplex automatic differentiation finite element method

Rapid cyclic temperature fluctuation occurring in powder bed fusion of metals using a laser beam (PBF-LB/M) influences the formation of flaws in printed parts. Consequently, there is a pressing need to enhance the quality of printed parts by developing innovative methodologies that can predict thermal histories and help uncover the intricate relationships between process parameters and thermal profiles. Sensitivity Analysis (SA) emerges as an essential tool for this, offering the potential for process optimization and enhanced quality control. Nonetheless, conventional SA methodologies often incur in excessive computational costs and potential numerical approximation errors. Here, to address this technical challenge, we present a novel method for SA that integrates the HYPercomplex-based Automatic Differentiation (HYPAD) technique with transient thermal simulations conducted via the finite element method (FEM). Leveraging this methodology, we efficiently and accurately perform SA for PBF-LB/M processes in a post-processing step. Compared to traditional methods like Finite Differences (FD), HYPAD-FEM required 96 % less computational time for obtaining sensitivities for 22 process parameters, under a comparative study conducted within the context of the 2018–02 AM benchmark of the National Institute of Standards and Technology. In summary, HYPAD-FEM offers superior efficiency and accuracy in SA over conventional methods, delivering the best sensitivity of a model without the need for step-size selection and problem or parameter-based implementations.

36 MATERIALS SCIENCE↗

Second spectrum of Manganese (Mn II), Part II: Revised fine and hyperfine structure analysis of odd-parity levels

In the first part of this global work, we have achieved the fine and hyperfine structure (fs and hfs) parametric study of even-parity levels, which confirmed in the whole the well-founded basis of previous analyses. Unfortunately, in the present work devoted to odd-parity levels, some divergences appear. For instance, the three levels w{sup 5}P{sub 3}, w{sup 5}P{sub 2}, w{sup 5}P{sub 1} located respectively at 86898, 86937 and 86961 cm{sup −1} should not belong to the 3d{sup 4}({sup 5}D)4s4p configuration, as indicated earlier, but rather to 3d{sup 5}({sup 4}P)5p. In the other hand, the levels whose energies are: 88 840, 89 079 and 89 429 cm{sup −1} should belong this time to 3d{sup 4}({sup 5}D)4s4p instead of 3d{sup 5}5p, as mentioned previously. Our analysis is strengthened when using experimental hfs data as finger prints, even if the comparison between these experimental hfs data, given in the literature, and our calculated results also shows in numerous cases some notable discrepancies, concerning particularly the sign of the electric quadrupole factor. The main monoelectronic hfs parameter values, extracted from our least square fitting procedure, are: a{sub 3d}{sup 01}(3d{sup 5}4p)= 17.58 mK, b{sub 3d}{sup 02}(3d{sup 5}4p)= 10.27 mK, a{sub 3d}{sup 01} (3d{sup 4}4s4p)= 18.74 mK and a{sub 4s}{sup 10}(3d{sup 4}4s4p)= 274.9 mK. These parameter values, displayed for the first time, were analyzed and compared with ab-initio calculations. As in the first part, we conclude this work by giving the predicted hfs A and B constants of low-lying levels of these two configurations, whose splitting are not yet measured.

74 ATOMIC AND MOLECULAR PHYSICS↗

Overcoming Steric Restrictions of VRC01 HIV-1 Neutralizing Antibodies through Immunization

Broadly HIV-1 neutralizing VRC01 class antibodies target the CD4-binding site of Env. They are derived from VH1-2*02 antibody heavy chains paired with rare light chains expressing 5-amino acid-long CDRL3s. They have been isolated from infected subjects but have not yet been elicited by immunization. Env-derived immunogens capable of binding the germline forms of VRC01 B cell receptors on naive B cells have been designed and evaluated in knockin mice. However, the elicited antibodies cannot bypass glycans present on the conserved position N276 of Env, which restricts access to the CD4-binding site. Efforts to guide the appropriate maturation of these antibodies by sequential immunization have not yet been successful. Here, we report on a two-step immunization scheme that leads to the maturation of VRC01-like antibodies capable of accommodating the N276 glycan and displaying autologous tier 2 neutralizing activities. Our results are relevant to clinical trials aiming to elicit VRC01 antibodies.

59 BASIC BIOLOGICAL SCIENCES↗