Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind energy systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Hawaii Fish Company Inc. Technical Assistance Voucher (Abstract)

For the past several years, the National Renewable Energy Laboratory (NREL), Sandia National Laboratories (SNL), and Pacific Northwest National Laboratory (PNNL) have provided technical assistance to the recipients of Department of Energy (DOE) -funded voucher programs, namely American-Made Challenges (AMC), the Incubator Program, and the Small Business Vouchers Program. Drawing on lessons learned and from first-hand experiences, NREL is leading a new holistic and streamlined voucher program aimed at strengthening ties between American innovators and the national labs. This new program, “Vouchers to Enable Laboratory and Organizational Collaboration for Innovation and Technology Improvements,” or VELOCITI, will leverage the successful elements of past programs, create administrative efficiencies, and enable the buildout of a national program to drive strong relationships between entrepreneurs and the national labs to accelerate the roll-out of new technologies in the US solar sector. This work will evaluate Hawaii Fish Company’s (HFC’s) floating renewable energy-powered aeration systems, designed primarily for aquaculture ponds, with crossover applications to farm ponds, reservoirs, and other water bodies. Notably, HFC’s systems include a variety of configurations, such as direct-solar systems, battery-storage systems, and systems with a secondary wind turbine option. HFC is planning to refine and commercialize their renewable energy aeration platforms. Presently, HFC is fabricating multiple configurations of the systems for deployment in multiple locations in the U.S. PNNL will apply technical expertise to assist in these goals, benefitting the industry partner by giving them an understanding of the performance of their systems. The technical objectives of this project are to understand system performance and reliability, determine a path toward certification, and model the performance of the systems in different locations.

99 GENERAL AND MISCELLANEOUS↗

Multiple and variable speed electrical generator systems for large wind turbines

A cost effective method to achieve increased wind turbine generator energy conversion and other operational benefits through variable speed operation is presented. Earlier studies of multiple and variable speed generators in wind turbines were extended for evaluation in the context of a specific large sized conceptual design. System design and simulation have defined the costs and performance benefits which can be expected from both two speed and variable speed configurations.

Andersen, T. S.↗

Levelized cost and carbon intensity of solar hydrogen production via water splitting using a scalable and intrinsically safe photocatalytic Z-scheme raceway system

Generating hydrogen from local energy resources such as solar or wind would unlock a low-carbon energy carrier that could be used to reduce greenhouse gas emissions in sectors such as industry and transportation. Yet, the allocation of new or existing power generation solely to hydrogen production remains contentious due to disputes regarding emissions accounting. Photocatalytic (PC) hydrogen production technologies offer a unique solution, as hydrogen is produced directly from solar energy and water, without the need for electricity generation. However, cost projections for all photocatalytic designs to date have suggested that they are not cost competitive compared to conventional electrolysis systems manufactured at scale. Herein, we offer the first illustrative benchmark of cost and carbon intensity of hydrogen produced in a type 2 “Z-scheme” photocatalytic reactor design, which employs suspended semiconducting nanoconductor particles organized into two stacked volumes in a raceway design. The “Z-scheme” system utilizes two separate photoabsorber particles, tuned to drive either the hydrogen evolution reaction or the oxygen evolution reaction individually, connected via a reversible, charge transfer redox couple in solution. Furthermore, the results suggest a highly competitive and scalable technology, that justifies further experimental validation and prototyping in the field.

Carbon↗

Challenges, opportunities, and a research roadmap for downwind wind turbines

This study investigates the challenges and opportunities presented by downwind wind turbines and offers a roadmap of future research pathways to maximize their potential. Multidisciplinary design, analysis, and optimization comparison studies between upwind and downwind configurations on a modern 10-MW offshore wind turbine are presented to support the discussion. On one hand, the downwind rotor is found to consistently have a smaller swept area under loading. As a result, the downwind design produces less annual energy production (-1.2%). On the other hand, lighter blades for the downwind configuration lead to lower capital costs (-1.7%), so there is little difference in the levelized cost of energy between the two. Key ultimate and fatigue loads are compared, with some values increasing in the downwind configuration, while others decrease. The impact of a downwind configuration on the tower and the impacts of cone and tilt angles and free-yaw system on the levelized cost of energy are also investigated. The results show a mix of some advantages and disadvantages. Given these results, four areas of research in advanced controls, highly tilted rotors, higher fidelity aerodynamic models, and floating wind are proposed for downwind wind turbines.

17 WIND ENERGY↗

Coastal Acoustic Buoy for Offshore Wind: Project Synthesis

The population of North Atlantic right whales is critically endangered and their habitat overlaps with offshore windfarm leases. It is therefore imperative that effective mitigation strategies be used to avoid impacts on right whales during the construction of offshore windfarms. The Department of Energy issued FOA Number DE-FOA-0001924 to encourage the development of technology that could monitor large exclusion zones for right whales in order to mitigate potential impact of construction noise on right whales. This report summarizes the past two years of the development and evaluation of the Coastal Acoustic Buoy for Offshore Wind (CABOW) project which aimed to develop technology to monitor large exclusion zones for North Atlantic right whales. Over the course of the project SMRU Consulting have implemented a rigorous design process including comparison of different approaches (e.g., single sensor vs multiple sensors), as well as consideration of placement and timing of acoustic monitoring. We have evaluated critical components of the CABOW system including, reliability, detection range, and bearing accuracy in areas adjacent to offshore windfarm leases in Maryland by conducting 3,536 playbacks of simulated right whale upcalls. The maximum call detection range was 7.5 km when noise was 99 dB re 1µPa rms (50-225 Hz), but this reduced to < 1 km when ambient noise levels were high. Our detection probability in the field was measured as a function of range as well as the source-to-noise level ratio allowing us to build a model to predict the probability of detection under various scenarios (sample size: 3,536 calls x 5 buoys = 17,680). The median bearing error was -0.25° but this is likely an underestimate of error due to experimental design. Using the published recall and precision of the two detectors we implemented in the CABOW system, we estimate that at a recall of 80%, our precision was > 80%, within the range of what we were aiming for in this project. To estimate our exclusion zone false negative and false positive rates, we built a simulation model using the empirical data from our field trial. We modelled three to nine CABOW units placed on the 10 km exclusion zone and estimated our false negative rate to be 1% or less (which was our project goal) and our false positive rate to be between seven and nine percent, slightly above our goal of 5%. However, we also modelled an equivalent PAM system that does not have bearing capabilities and found the false positive rates for that system to be six to eight times higher than the CABOW rate. This higher false positive rate of PAM systems with low spatial information could have significant cost repercussions for offshore wind developers by adding work shutdowns or delays without providing additional protection for right whales. The model we built allows us to explore the placement of PAM systems under various scenarios and will thus help facilitate planning of PAM mitigation systems to meet NOAA Incidental Harassment Authorizations for specific windfarms. We achieved an average system uptime of 98.3%, just below our goal of 99%. The issues that caused these short losses of data have been identified and fixed. Right whale detections and audio clips were typically transferred via radio from the buoys to the base station in two to four seconds. We therefore believe we have developed a highly robust real-time PAM system. Based on the above, we feel we have achieved the stated funding goal of developing a cost-effective and robust real-time PAM system that enables the monitoring of large exclusion zones for right whales during the constructions of offshore windfarms. This should lead to decreased costs and risks for the offshore wind sector while providing robust mitigation for right whales. It is important to state that PAM mitigation will need to be implemented with other mitigation strategies (e.g., visual observers) to provide a complete mitigation strategy to ensure that any effects on right whales from offshore windfarm construction is minimized.

17 WIND ENERGY↗

Categorizing distributed wind energy installations in the United States to inform research and stakeholder priorities

Abstract Background Distributed wind energy adoption in the United States can contribute to the diverse portfolio of energy technologies needed to achieve ambitious decarbonization goals. However, with limited deployment to date, the current distributed wind market must be better understood; these efforts will support the range of stakeholders who will drive successful deployment. This article first distinguishes three categories of distributed wind from existing literature: (1) behind the meter, (2) intended for explicit local load, and (3) physically distributed. A novel methodology to classify individual wind installations into each of these categories is then presented and applied to two data sets of wind installations in the United States to categorize and illuminate distinct segments in the distributed wind market. Results Physically distributed installations, constituted by small to moderately sized projects serving local loads on distribution systems solely because of their proximity to them, account for the highest amount of capacity but the lowest number of installations out of the three categories. The inverse is true for behind-the-meter installations, which are used to serve on-site loads. Installations intended for explicit local load, which are interconnected on the utility side of the distribution system and intentionally built to provide energy to loads on the same distribution system, rank in the middle for both installed capacity and number of installations. Conclusions Distributed wind energy deployment in the United States is geographically widespread, but the extent to which a single category is developed in each state varies. Policies, wind resources, and broad energy technology trends contribute to these deployment patterns. By identifying the extent to which each category of installations exists, decision-makers are empowered with data necessary to tailor research and development programs and address stakeholder priorities through policy and other means, ultimately supporting future deployment.

17 WIND ENERGY↗

Hydro-battery Hybrids – A Case for Holistic Assessment of Hybrid Energy Systems

With increasing penetration of renewable energy resources like solar and wind, the flexibility offered by the hydropower generation facilities would be instrumental in providing grid reliability. However, hydropower’s capabilities are often constrained to meet asset management targets and environmental flow requirements. To meet these necessary requisites while simultaneously being able to utilize hydropower’s full potential, hydro plus battery hybrids offer a logical solution. However it is often challenging to make the case for economic feasibility of hydro-battery hybrids at the required scale of battery storage. To that end, this paper proposes a multi-objective optimization framework to maximize advantages of hydro-battery hybrid systems from three different avenues: new market opportunities, environmental benefits and machine wear and fatigue. Using an illustrative case study of a peaking plant, we simulate hydropower operations for with and without 120 MWh of battery storage for four different simulated flow patterns ranging from peaking operations to run-of-the-river operations and two intermediate flow patterns in between. The results demonstrate that hybridizing the hydropower plant can potentially generate additional revenue while simultaneously enable more environmental friendly operations and reduce the overall machine wear and tear.

Chalishazar, Vishvas H.↗

Marine energy supported multi-energy system planning and operation optimization for sustainable coastal community

The growing need for sustainable energy solutions in coastal areas necessitates the development of integrated systems that leverage abundant marine resources. In this study, a standalone Marine Energy Supported Multi-Energy System (MRE-MES) is designed for sustainable coastal community development, utilizing renewable marine resources, including offshore wind, wave, and solar energy, to address the energy needs of electricity, heat, freshwater, and hydrogen. The proposed MRE-MES incorporates a co-optimization model that simultaneously balances capacity planning and operational efficiency to minimize costs and environmental impacts. The system is tested under different renewable energy penetration levels and demand uncertainties, using a two-stage stochastic programming to account for variability in renewable resources and consumption needs. The experimental results indicate that in the optimal system capacity configuration, the percentage of total renewable energy generation is around 80 %, with or without capacity limitation constraints on PV, water tank, and hydrogen storage. Compared to the worst-case scenario in Monte Carlo experiments, two-stage stochastic optimization results in a more robust decision that effectively mitigates the risks posed by future uncertain demand conditions. In conclusion, the findings highlight the viability of marine energy for providing a resilient, comprehensive energy solution to coastal communities.

Capacity planning↗

Global Energy and Aviation Concerns

Renewable energy sources are usually diffuse and require large facilities. Biofuels work better, are more economical to produce for ground transportation, but sharply increase competition for food croplands. Noble laureate Richard Smalley (deceased-2005) conceptual 20 TWe power generation covers hundreds x hundreds of miles. Combined with Fuller s superconducting power grid system would enable renewable planetary energy. A solar-wind project in Australia will have a 7km diameter collector interfacing with a 1 km tower to extract 200 MW from wind turbines mounted at the base. GE Energy s 3.5MW Wind Turbine is large and placing this in perspective, it is as if one were rotating a Boeing 747-200; the blade diameter is that large. Wind turbines are rapidly gaining popularity in Europe and photovoltaic (PV) is expected to also expand rapidly. It becomes clear that we need (and still have time) to develop new sources of energy. Hf 178 bombarded by X-rays produces Gamma-rays for heating. The reaction stops when the X-rays stop; the half life is about 30 years and seems manageable vs 30 000 years. Water splitting needs to be perused as do ultra fast ultra intense laser applications in terms of fusion and new materials developments including new ways to strip and re-bind hydrogen into fuels. New methods and tools for development are being found in quantum mechanical applications to macro-systems and need to be developed into a set of new tool boxes for development of these new energy sources.

Hendricks, Robert C.↗

An Evaluation of Advanced Tools for Distributed Wind Turbine Performance Estimation

We evaluate various classes of distributed wind turbine performance tools across two sites in the United States. The class of tools ranges from the simple mass conservation model to the coupled Reynolds-averaged Navier-Stokes model, all initiated by the WIND Toolkit data set. The resource estimation at the site is evaluated against measured data at the mast location. Taking a sample 100-kW wind turbine and constant losses, we evaluate Openwind, Continuum, and WindNinja tools and document annual energy production (AEP) and time-series statistics associated with the performance estimation of the wind turbine. Using a methodology that is consistent and unbiased across the three options currently available in the industry, we elaborate results at the two sample locations and discuss the probable sources of discrepancy in the AEP estimates. Two main sources of the discrepancy come from the input WIND Toolkit data and the spatial modeling techniques of the tools to capture atmospheric physics. The discussion includes additional values that these tools may bring into the energy assessment process to enhance the owners' confidence over the distributed wind power systems.

17 WIND ENERGY↗

Pathways to the Next-Generation Power System With Inverter-Based Resources: Challenges and recommendations

Managing the stability of today's electric power systems is based on decades of experience with the physical properties and control responses of large synchronous generators. Today's electric power systems are rapidly transitioning toward having an increasing proportion of generation from nontraditional sources, such as wind and solar (among others), as well as energy storage devices, such as batteries. In addition to the variable nature of many renewable generation sources (because of the weather-driven nature of their fuel supply), these newer sources vary in size - from residential-scale rooftop systems to utility-scale power plants - and they are interconnected throughout the electric grid, both from within the distribution system and directly to the high-voltage transmission system. Most important for our purposes, many of these new resources are connected to the power system through power electronic inverters. Collectively, we refer to these sources as inverter-based resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of renewable energy generation and storage systems for emissions reduction in an islanded campus microgrid

Microgrid connected building communities are projected to play an integral part in the clean energy transition. These types of systems, when integrated with distributed energy resources (DERs) such as combined heat and power (CHP), district heating and cooling, renewable generation, and energy storage, can provide clean, reliable power to critical facilities and vulnerable communities. The intermittent nature of renewable generation is a challenge when integrating renewables into any grid system, but particularly in islanded microgrids. The University of Texas at Austin (UT) operates an islanded microgrid powered by a CHP plant, while also utilizing district heating and cooling systems and thermal energy storage (TES). High fidelity operating data was used to develop a validated reduced order model of UT’s integrated campus energy systems to serve as a testbed for use in a case study. Hypothetical renewable energy installations on land owned by UT in west Texas were modeled and integrated into the validated campus models along with battery energy storage (BES). Simulations showed that a combination of renewable energy from wind, and optimally controlled 24-hour thermal and battery storage systems could reduce carbon dioxide emissions on campus by 45.4%. The additional retrofit of burner systems to utilize hydrogen natural gas blends resulted in an overall annual emissions reduction of 54.7%. Carbon capture and storage eliminated the majority of the remaining emissions with increased plant energy expenditure. The presented simulations display the practical limitations of a CHP system complemented by renewable generation and short-term storage in eliminating emissions. Furthermore, results highlight the need for further research and development in long duration storage technologies and hydrogen fueled turbines to increase penetration of renewable energy and reduce emissions.

CHP↗

A brief summary of the attempts to develop large wind-electric generating systems in the U.S.

Interest in developing large wind-electric generating systems in the United States was stimulated primarily by one man, Palmer C. Putnam. He was responsible for the construction of the largest wind-power system ever built - the 1250 kilowatt Smith-Putnam wind-electric plant. The existence of this system prompted the U.S. Federal Power Commission to investigate the potential of using the winds as a source energy. Also, in 1933 prior to Putnam's effort, there was an abortive attempt by J. D. Madaras to develop a wind system based on the Magnus effect. These three projects comprise the only serious efforts in America to develop large wind driven plants. In this paper, the history of each project is briefly described. Also discussed are some of the reasons why wind energy was not seriously considered as a major source of energy for the U.S.

Savino, J. M.↗

Design and analysis of a ten-turbine floating wind farm with shared mooring lines

This paper discusses the development and analysis of a novel design for a 10-turbine floating wind farm with shared mooring lines. Shared mooring lines tether adjacent floating platforms together, reducing the number of anchors required but increasing system complexity. We present a systematic, multistage design process for shared mooring systems, involving linearized analysis of array layout options, quasi-static mooring line optimization, and design refinement based on coupled dynamic loads analysis. The design developed from this process is thought to represent one of the most advantageous shared-mooring configurations for this scale of floating wind array. It features perpendicular anchor line pairs and allows shared, multiline anchors, making it an example of a shared-mooring-and-anchor array. Comparing the performance and cost characteristics of the shared-mooring design with more conventional three-line individual mooring systems shows equivalent dynamic response characteristics and stationkeeping system cost savings of 25% when using shared mooring lines and shared anchors. The design is also advantageous in the case of a mooring line failure, with offsets and redundancy characteristics similar to four-line individual mooring systems.

17 WIND ENERGY↗

Managing Solar Photovoltaic Integration in the Western United States: Power System Flexibility Requirements and Supply

As penetrations of variable renewable energy generation technologies such as wind and solar photovoltaics (PV) continue to increase across the United States, greater uncertainty and variability in the net load often lead to a concern about how power systems may adapt. Managing the system net load (i.e., load minus contribution from variable generation technologies) may become more challenging with increasing variable generation, as the magnitude and frequency of net ramps increase. However, there is inherent flexibility in power systems through the conventional generator fleet (under least-cost unit commitment and economic dispatch), less-conventional generation sources (e.g., storage, demand response, concentrating solar power with thermal energy storage), and imports and exports with neighbors. In this analysis, we create an open-source tool to analyze the flexibility of the results of a specific commercial unit commitment and economic dispatch tool (PLEXOS), but the code can be applied generically as well. The tool assesses the flexibility requirements (or demand) of a system through a net load analysis. The constraints and limitations of each generator are then considered to determine the availability (or supply) of flexibility. Then, the supply and demand of flexibility are compared to gain a more complete picture of potential flexibility concerns. We apply this open-source tool to high-penetration PV scenarios constructed for three focus regions in the western United States defined using the Resource Planning Model (RPM) capacity expansion modeling tool: RPM-OR, RPM-CO, and RPM-AZ. Generally, we find few flexibility concerns, as the western United States represents a large and interconnected power system with significant inherent flexibility. In addition, the PV scenarios we analyzed are overbuilt on capacity, leaving plenty of ramping ability on the system. We do find that for each focus region, the impact of imports on meeting ramping needs is essential. This means the PV integration in each focus region impacts the entire rest of the system. Each system has different dominant sources of flexibility. The conventional generator fleet (especially coal and gas combined-cycle technologies) as well as less-conventional sources such as storage are all shown to be important sources of flexibility. The scenarios evaluated here were designed to study the planning and operations impact of high solar penetration in each of three focus regions. However, none of the three focus regions likely will deploy PV in isolation, meaning the ability of imports and exports to provide flexibility may be considerably different in scenarios with strong PV deployment in every region. Overall, we intend that the framework we present here will be useful in future analysis of other system evolutions to identify whether and how flexibility may constrain the successful deployment of variable generation technologies.

14 SOLAR ENERGY↗

The Physical and Engineering Limits of Coupled In situ TEM Experiments

Almost all future energy systems (advanced nuclear reactors, fusion energy system, concentrating solar-thermal power (CSP), and wind technologies) are limited by degradation of key material systems exposed to multiple environmental stressors. The degradation during exposure to high temperatures, radiation, mechanical loading, and chemical attack is often dictated by mechanisms active at the microstructural level. The nature of these mechanisms and the associated variations between sequential and concurrent interplay can be explored if the transmission electron microscope (TEM) is utilized as a toolbox for exploration [1]. One such tool developed at Sandia National Laboratories to couple several of these environments is the In situ Ion Irradiation TEM (I3TEM) [2]. Several studies over the last decade utilizing this tool have shown that the scientific intuition developed over decades of sequential experiments is not always a good indicator of concurrent mechanisms or failure routes. This presentation will highlight the recent and planned additions into the I3TEM facility of a Waviks gas injection system and Raman system, respectively, as can be seen in Fig. 1, permitting environmental degradation from gas species leaked into the pole piece region during quantitative mechanical loading (indentation, monotonic loading, high temperature creep, irradiation induced creep, and high-cycle fatigue); multi-beam ion irradiation (energies ranging from 1 keV to 48 MeV and species from H to Au); laser exposure (20 W and 1064 nm), or various combinations thereof that are already possible [3]. This addition permits the facility to explore both sequential or concurrently the four axes of stressors: thermal, mechanical, radiation, and chemical. This information can be directly coupled to modeling, expediting the refinement and validation of both atomistic and mesoscale models.

degradation↗

Land Resources for Wind Energy Development Requires Regionalized Characterizations

Estimates of the land area occupied by wind energy differ by orders of magnitude due to data scarcity and inconsistent methodology. Here, we developed a method that combines machine learning-based imagery analysis and geographic information systems and examined the land area of 318 wind farms (15,871 turbines) in the U.S. portion of the Western Interconnection. We found that prior land use and human modification in the project area are critical for land-use efficiency and land transformation of wind projects. Projects developed in areas with little human modification have a land-use efficiency of 63.8 ± 8.9 W/m 2 (mean ±95% confidence interval) and a land transformation of 0.24 ± 0.07 m 2 /MWh, while values for projects in areas with high human modification are 447 ± 49.4 W/m 2 and 0.05 ± 0.01 m 2 /MWh, respectively. We show that land resources for wind can be quantified consistently with our replicable method, a method that obviates >99% of the workload using machine learning. To quantify the peripheral impact of a turbine, buffered geometry can be used as a proxy for measuring land resources and metrics when a large enough impact radius is assumed (e.g., >4 times the rotor diameter). Our analysis provides a necessary first step toward regionalized impact assessment and improved comparisons of energy alternatives.

17 WIND ENERGY↗

Process-Based Balance-of-System Cost Modeling for Offshore Wind Power Plants in the United States: Preprint

This work describes the development of a process based and open source balance of system cost model which provides the capability to evaluate both existing and novel offshore wind technologies. Individual design and installation steps are represented with bottom-up engineering models that compute the times and costs associated with the process; furthermore, operational constraints are assigned to each process so that delays due to weather and presence of marine mammals may be accounted for in the overall project timeline. The model structure, assumptions, inputs, and results are vetted with industry partners and compared against actual projects for validation; installation times are shown to agree with real data with relative errors of less than 35\%. Case studies are presented to demonstrate the functionality of the model. First, individual vessel efficiencies are computed for varying numbers of installation vessels and weather time series to show the diminishing returns of more than two feeder barges. Then, array cable capital costs and installation times are determined for a representative project with different turbine sizes. This quantifies the cost benefit tradeoffs of decreasing number of turbines, increased turbine spacing, and fewer turbine terminations and shows a net cost savings. These results demonstrate that the BOS model features the accuracy, functionality, and accessibility to serve as the foundation for a wide range of analyses to identify cost reduction potentials for offshore wind energy in the United States.

17 WIND ENERGY↗