Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “waveforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A Lookup Table Based Low Resource Usage Waveform Data Compression Block in FPGA

aA lookup table based lossless data compression scheme suitable for FPGA implementation, with very low silicon resource usage, is developed. Different algorithms can be implemented by simply changing the contents of the lookup tables in the functional block while keeping the logic circuits unchanged. It exhibits performance comparable to the zip compression software in Linux distributions. The compression block can fit into almost any existing FPGA used in the online data acquisition systems of high energy physics experiments. The decompression process can be performed in either software or in FPGA firmware, allowing users to process compressed data flexibly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

System and method for high dynamic range waveform digitization

Diverse applications from particle physics experiments to lidar are driving cost and current reduction in giga-hertz sampling rate high-resolution data conversion. Multiple imagers captures a single pixel of data and require processing at very high speed. High-bandwidth high-rate signal sampling, analog-to-digital conversion, and transfer of large amounts of data to a digital data acquisition block are required in such systems. Dynamic range, power consumption, and transfer of high-speed, high-bit width data are key implementation challenges. Data acquisition architectures optimized for specific requirements of such systems may facilitate system implementation and reduce overall system cost.

Mostafanezhad, Isar↗

Temporal resolution and fidelity enhancement of arbitrary waveforms

Apparatuses comprising cascaded or series configurations of Mach-Zehnder electrooptic modulators, where the nonlinearities of the cascaded and series configurations of Mach-Zehnder electrooptic modulators increase signal bandwidth and boost signal fidelity in electronic digital to analog converters. The Mach-Zehnder electrooptic modulators are combined with photodiode detectors that are used to convert signals from the optical domain to the electrical domain.

Muir, Ryan D.↗

Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging

Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantom under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUV{sub max}, SUV{sub mean}, SUV{sub peak}, and segmented tumor volume was evaluated as RC{sub max}, RC{sub mean}, RC{sub peak}, and RC{sub vol}, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by the patient-specific respiratory waveforms; when testing patient and sinusoidal waveforms separately, patient waveforms were significantly different between phases (p < 0.0001) while the sinusoidal waveforms were not significantly different (p = 0.98). When considering only the subset of 4DMATCH images that corresponded to the end-exhale image phase, 4DEXH, mean and interquartile range were similar to 4DMATCH but variability was considerably reduced. Conclusions: Comparative advantages in accuracy and precision of SUV metrics and segmented volumes were demonstrated with the use of the maximum intensity projection and end-exhale CT attenuation correction. While respiratory phase-matched CTAC should in theory provide optimal corrections, image artifacts and differences in implementation of 4DCT and 4DPET sorting can degrade the benefit of this approach. These results may be useful to guide the implementation, analysis, and development of respiratory-correlated thoracic PET/CT in the radiation oncology and diagnostic settings.

60 APPLIED LIFE SCIENCES↗

Alternate Null Hypothesis Correlation: A New Approach to Automatic Seismic Event Detection

This paper describes a new method of seismic signal detection that improves upon the conventional waveform correlation method. Recent studies suggested that a significant limiting factor in the application of waveform correlation to regional and global scale monitoring is the false alarm rate. The false alarms do not originate from detections on noise but rather from seismic arrivals with unrelated source locations. This article presents results from an approach to waveform correlation that exploits techniques from signal processing and machine learning to improve the accuracy of detecting seismic arrivals. We modify the detection model for waveform correlation such that transient signals from noncollocated seismicity are considered when designing the detectors. The new approach uses waveform templates from known catalog events to train a supervised machine learning algorithm that derives a new set of detectors to represent the unique characteristics of the template waveforms; these new detectors maximize the likelihood of detecting only the desired events, thereby minimizing false alarms. We train a waveform correlation template library for a single three-component seismic monitoring station. We then review results from applying the new detectors, known as alternate null hypothesis correlation (ANCorr) templates, to a test set of seismic waveforms. Finally, we compare ANCorr results with those from application of the conventional waveform correlation matched filter technique.

58 GEOSCIENCES↗