Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters: Preprint

A quarter of all housing units in the country are found in multifamily buildings but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single family homes are often a poor fit for individual multifamily units since the water heaters are often located in small internal closets. This confined space can limit the air flow to the heat pump and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Improving and Measuring Water Oxidation Catalyst Viability

A major challenge that limits the efficiency of the overall water splitting reaction is the oxidation half-reaction, a process that releases oxygen and electrons, which in turn can reduce either protons or carbon dioxide to make hydrogen or carbon-based fuel. In this project, the major objectives are to increase the stability of water oxidation catalysts (WOCs), to develop ways to study catalyst stability, and to enable WOC performance in acidic media.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photochemical modelling of Venus clouds using Pioneer Venus data

In order to understand the evolution of water on Venus, we must know the hydrogen escape flux as a function of the tropospheric water abundance. We have studied the connection between total stratospheric hydrogen and exobase hydrogen available to non-thermal escape processes and examined the details of the photochemical trap for water at the Venus cloud tops. Our immediate goal is to calculate the stratospheric water abundance as a function of the tropospheric water abundance. Photochemical production of H2SO4 acts as a sink for both water and sulfur and is capable of keeping stratospheric abundances low if a proper balance exists between the tropospheric abundances. If production of H2SO4 were the only sink for H2O and SO2, the excess in tropospheric abundance of one over the other would reach the stratosphere, and the functional dependence of stratospheric H2O on tropospheric H2O would be linear near the present state. On Venus, however, sulfuric acid condenses at cloud top temperatures and the resulting aerosols can absorb additional water of hydration. This complicates the water budget, increasing the efficiency of sulfur as a sink for water. We have investigated the balance between tropospheric H2O and SO2 and how delicate the balance is. Our major conclusions from this work are the following: (1) H2O and SO2 are mutually limiting if proper tropospheric balance is maintained; (2) changes in tropospheric abundances on the order of 5 ppm are significant; and (3) changes in mixing rates near the cloud tops can cause dramatic changes in SO2 without causing dramatic changes in H2O.

Mcelroy, Michael B.↗

Efficiency and Capacity Performance of a Stirling-Cycle Water-to-Water Heat Pump

The performance of a 10 kW (2.8 ton) heat pump has been modeled in preparation for evaluation in a controlled-atmosphere psychrometric facility. The heat pump uses an electrically driven Stirling engine with nitrogen as a working fluid. The appropriate standards for testing are ANSI/AHRI/ASHRAE ISO Standard 13256-2:1998 (RA 2012), Water-Source Heat Pumps—Testing and Rating for Performance—Part 2: Water-to-Water and Brine-to-Water Heat Pumps. The heating and cooling efficiency and capacity of the device has been modeled at different hot and cold sink temperatures spanning a wide range of possible operating conditions. The heat pump was designed for a seasonal efficiency energy ratio (SEER) of 22. The high efficiency of this product coupled with the use of nitrogen as a working fluid makes it an important tool for the decarbonization of residential, commercial, and industrial HVAC&R applications.

Kowalski, Steve↗

Molecular beam scattering of neon from flat jets of cold salty water

Molecular beam scattering experiments are carried out to study collisions between Ne atoms (E i = 24.3 kJ mol-1) and the surface of a cold salty water (8 m LiBr(aq), 230 K) flat jet. Translational energy distributions are collected as a function of scattering angle using a rotatable mass spectrometer. Impulsive scattering and thermal desorption contribute to the overall scattering distributions, but impulsive scattering dominates at all three incidence angles explored. Highly super-specular scattering is observed in the impulsive scattering channel that is attributed to anisotropic momentum transfer to the liquid surface. The thermal desorption channel exhibits a cos θ angular distribution. Compared to Ne scattering from dodecane, fractional energy loss in the impulsive scattering channel is much larger across a wide range of deflection angles. A soft-sphere model is applied to investigate the kinematics of energy transfer between the scatterer and liquid surface. Fitting to this model yields an effective surface mass of 250-60 +100 amu and internal excitation of 11.8 ± 1.6 kJ mol-1, both of which are considerably larger than for Ne/dodecane. It thus appears that energy transfer to cold salty water is more efficient than to a dodecane liquid surface, a result attributed to the extensive hydrogen-bonded network of liquid water and roughness of the liquid surface.

Yang, Walt↗

Test Results for the SEA Ice Crystal Detector (ICD) under SLD Conditions at the NASA IRT

The Science Engineering Associates hot-wire Ice Crystal Detector was tested under Appendix C and Supercooled Large Drop Conditions at the NASA Icing Research Tunnel, with the purpose of comparing the measurements to the tunnel LWC calibration, and to test the performance of the mixed-phase retrievals of the probe. The liquid water content measured by the total water content sensor of the probe agreed well with the tunnel calibration over a wide range of MVDs, not unexpectedly since the tunnel was calibrated with a similar Multiwire hot-wire probe. A scale factor difference of about 7% was attributed to the lack of an efficiency correction for the Ice Crystal Detector at smaller median volume diameters, and typical sample area uncertainties of liquid water content devices. In addition, the simultaneous equations that are used to retrieve liquid and ice water contents were tested under liquid and glaciated conditions. Using constant ice and water efficiencies for each wire, the equations were found to produce a large and false ice water content retrieval in large median volume diameter liquid cases. By applying a liquid efficiency to the liquid water content sensor that varied with median volume diameter, retrievals were improved such that false ice water content was less than ±10% of the total water content out to the 460 μm median volume diameter limit of the testing. The probe was also tested in glaciated conditions by freezing out a small median volume diameter spray. Using constant ice efficiencies for the two sensors provided from aircraft measurements, the retrieved ice water content was about 40% higher than expected for the case presented, likely due to the ice efficiencies that were used from aircraft measurements of natural clouds being too low for the tunnel’s glaciated sprays. Application of ice efficiencies that vary with particle size and potentially other parameters will be explored for future improvement of retrievals.

Air Craft Icing↗

Test Results for the SEA Ice Crystal Detector (ICD) under SLD Conditions at the NASA IRT

The Science Engineering Associates hot-wire Ice Crystal Detector was tested under Appendix C and Supercooled Large Drop Conditions at the NASA Icing Research Tunnel, with the purpose of comparing the measurements to the tunnel LWC calibration, and to test the performance of the mixed-phase retrievals of the probe. The liquid water content measured by the total water content sensor of the probe agreed well with the tunnel calibration over a wide range of MVDs, not unexpectedly since the tunnel was calibrated with a similar Multiwire hot-wire probe. A scale factor difference of about 7% was attributed to the lack of an efficiency correction for the Ice Crystal Detector at smaller median volume diameters, and typical sample area uncertainties of liquid water content devices. In addition, the simultaneous equations that are used to retrieve liquid and ice water contents were tested under liquid and glaciated conditions. Using constant ice and water efficiencies for each wire, the equations were found to produce a large and false ice water content retrieval in large median volume diameter liquid cases. By applying a liquid efficiency to the liquid water content sensor that varied with median volume diameter, retrievals were improved such that false ice water content was less than ±10% of the total water content out to the 460 μm median volume diameter limit of the testing. The probe was also tested in glaciated conditions by freezing out a small median volume diameter spray. Using constant ice efficiencies for the two sensors provided from aircraft measurements, the retrieved ice water content was about 40% higher than expected for the case presented, likely due to the ice efficiencies that were used from aircraft measurements of natural clouds being too low for the tunnel’s glaciated sprays. Application of ice efficiencies that vary with particle size and potentially other parameters will be explored for future improvement of retrievals.

o Aircraft Icing↗

Physical processes in polar stratospheric ice clouds

A one dimensional model of cloud microphysics was used to simulate the formation and evolution of polar stratospheric ice clouds. Some of the processes which are included in the model are outlined. It is found that the clouds must undergo preferential nucleation upon the existing aerosols just as do tropospheric cirrus clouds. Therefore, there is an energy barrier between stratospheric nitric acid particles and ice particles implying that nitric acid does not form a continuous set of solutions between the trihydrate and ice. The Kelvin barrier is not significant in controlling the rate of formation of ice particles. It was found that the cloud properties are sensitive to the rate at which the air parcels cool. In wave clouds, with cooling rates of hundreds of degrees per day, most of the existing aerosols nucleate and become ice particles. Such clouds have particles with sizes on the order of a few microns, optical depths on order of unity and are probably not efficient at removing materials from the stratosphere. In clouds which form with cooling rates of a few degrees per day or less, only a small fraction of the aerosols become cloud particles. In such clouds the particle radius is larger than 10 microns, the optical depths are low and water vapor is efficiently removed. Seasonal simulations show that the lowest water vapor mixing ratio is determined by the lowest temperature reached, and that the time when clouds disappear is controlled by the time when temperatures begin to rise above the minimum values.

Toon, Owen B.↗

Optimizing the surface distribution of acid sites for cooperative catalysis in condensation reactions promoted by water

Addition of small amounts of water to the organic solvent may result in different promoting or inhibiting effects in aldol condensation reactions depending on the distribution of active sites on the surface. In a combination of liquid-phase catalytic activity measurements, spectroscopies and theoretical calculations, we have shown that water clusters around the acid site can form bridges with a ketone molecule located close to the activated carbonyl, on another site. When the distance between the two acid sites is greater than a distance corresponding to about 2 water molecules, the efficiency of the bond polarization of the ketone by a remotely located acid site decreases significantly, and the presence of water no longer promotes the reaction. Furthermore, this work provides a quantitative assessment of how solvent molecules can bridge isolated active sites to enable cooperative catalysis, which offers an additional dimension for engineering catalysis at the nanoscale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C

Drainage structures are used to capture stormwater runoff in streets and highways in urban environments. These drainage structures, which typically consist of catch basins with grates, inlets, or combination grates/inlets, collect stormwater runoff and discharge through buried conveyance systems. They are strategically placed for public safety in curb and gutter systems to provide efficient drainage of water from roadways and thus reduce the risk of hydroplaning. The performance of drainage structures is measured in terms of hydraulic efficiency, which is defined as the percentage of flow captured by the basin as compared to the total flow drainage to the structure. Understanding of the performance of these drainage structures helps designers properly space inlets to promote an economic design that ensures the safety of the traveling public. The current design methodology used to determine drainage structure follows guidelines established in the current Michigan Department of Transportation (MDOT) Drainage Manual (2006). The guidelines in the MDOT Drainage Manual were modeled after the Federal Highway Administration’s (FHWA) Hydraulic Engineering Circular 22 “Urban Drainage Design” (HEC-22). HEC-22 includes empirically derived equations to calculate the interception capacity of drainage structures for several commonly used grate configurations, such as the parallel bar, curved vane and tilt bar grates, which are based on a research study performed by Burgi et al. in the 1970s. MDOT uses several drainage structures to capture runoff that are detailed as Standard Plans. Many of these drainage structures utilize sinusoidal type grates that are not described in HEC-22. Physical modeling of these structures has been limited, posing the need to have them analyzed to verify their capture efficiency. Current MDOT practice is to assume a similar sized reticuline grate, as described in HEC-22, for capture efficiencies. Until recently, evaluating the hydraulic performance of drainage structures was limited to physical modeling in a hydraulics laboratory. With advances in engineering software and computing power, computational fluid dynamics (CFD) modeling has become a more cost-effective alternative. The Federal Highway Administration (FHWA) provides states the option to evaluate their drainage structures using CFD through the Transportation Pooled Fund Program. This study, “Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C,” was carried out using the pooled fund. MDOT’s Cover C was chosen as the first test candidate, given its similar sinusoidal pattern to other MDOT grates, but it is typically used for high-volume, higher speed applications. A similar version, Cover CX, is used on interstate highways but does not have traverse bars for bicycle safety. Additional grates may be considered for evaluation in the future.

42 ENGINEERING↗

ENERGY STAR Residential Water Heater Specification and Test Method for Connected Residential Water Heaters

Electric water heaters have long been used as a tool for demand response due to their inherent thermal storage and large electric load. Traditionally, electric water heaters have been controlled by external load control switches, but that type of control does not work well with more efficient heat pump water heaters and cannot ensure that consumers have adequate hot water. Water heater manufacturers are adding more sophisticated controls that allow utilities or consumers to control their water heaters in new ways that can provide demand response without impacting consumer comfort. Further, the electric utility grid has seen a rapid increase the availability of renewable energy, which, depending on the type of renewable energy, can provide large amounts of energy for a portion of the day, but reduced or no energy at other times. In response to these advances in controls, availability of periodic renewable energy, and in an effort to have a standard which can be applied at a national level, ENERGY STAR and the Department of Energy have developed a Product Specification and Test Method for Connected Residential Water Heaters. In this session, we will discuss the new specification and test method, as well as show some initial results from running the new test method with two different HPWHs at NREL.

connected water heater↗

Hydrogen production by photoelectrolytic decomposition of H2O using solar energy

Photoelectrochemical systems for the efficient decomposition of water are discussed. Semiconducting d band oxides which would yield the combination of stability, low electron affinity, and moderate band gap essential for an efficient photoanode are sought. The materials PdO and Fe-xRhxO3 appear most likely. Oxygen evolution yields may also be improved by mediation of high energy oxidizing agents, such as CO3(-). Examination of several p type semiconductors as photocathodes revealed remarkable stability for p-GaAs, and also indicated p-CdTe as a stable H2 photoelectrode. Several potentially economical schemes for photoelectrochemical decomposition of water were examined, including photoelectrochemical diodes and two stage, four photon processes.

Rauh, R. D.↗

A novel approach for produced water treatment: Supercritical water oxidation and desalination

Produced water generated from oil and gas operations contains significant quantities of environmentally hazardous hydrocarbons, organic chemicals, and inorganic salts. Environmental regulations with impaired water disposal mandates produced water treatment and desalination. Industry standard desalination technologies are energy-intensive and mandate extensive produced water pre-treatment including removal of hydrocarbons constituents for efficient operations. Herein this study investigates a novel process intensification approach integrating supercritical water oxidation (SCWO) unit operation with a supercritical water desalination (SCWD) process for energy efficient produced water treatment and desalination. The coupled SCWD-SCWO process is found to be very energy-efficient and cost effective than existing industry standard desalination technologies. For energy efficient operation, the heat generated from the SCWO of hydrocarbons present in the produced water is used for power generation using a high efficiency and low-cost re-heat Rankine cycle process. The cost of treating produced water with proposed SCWO-SCWD process is independent of the salt concentration. The proposed process has the potential to offer step-change improvements over conventional processes in both the efficiency and cost of produced water treatment: for example, a cost and energy saving of 70% and 100% is calculated for the treatment of produced water containing 250 g/l salt and 10.6 g/l hydrocarbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Method to Design and Optimize Axial Flow Cyclones for Gas–Liquid Separation

This article provides a detailed design guide, optimization, and performance assessment for air–water separation of an axial flow cyclone. Axial flow cyclones (also known as swirl tube demisters, mist eliminators, or Austin–Write cyclones) have a range of applications in several different industries. This method of gas–liquid separation offers many benefits. Among these are high liquid separation efficiencies (near 99%) and an inline design that allows them to be more easily fitted into existing piping structures. Despite these benefits, there are several design parameters that have not been optimized for performance in wastewater purification applications. This research fills the gap in the literature by quantifying the effect of new design parameters on water collection efficiency, η water collection , and the air bypass efficiency, η air bypass , defined as the ratio of the air mass flowrate exiting through the desired air outlet over the inlet air mass flowrate. A set of wide-ranging experiments were conducted to study the effects of gas–liquid flow rates, tube geometry, and relative injection angles to optimize the water collection and air bypass efficiencies. The water collection efficiency exceeded 99.8% when the liquid streamline came in direct contact with the water drainage exit. An empirical correlation was developed to predict the swirl pitch as a function of the above design parameters. Predictions from the correlation were within 10% of the experimental results. The correlation can be used to design highly efficient in-line gas–liquid separators.

Engineering↗

Residential Integrated Heat Pump to Meet All the Home Comfort Needs

This paper will introduce development and field trial of a residential air-source integrated heat pump for cold climates. The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating. The integrated heat pump is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency > 30.0 EER and required only 25 minutes to heat a 50-gallon tank of water. One heat pump prototype is going through a field trial since April, 2023 in Syracuse, New York. The one-year field test results are summarized.

Shen, Bo↗

HydroGEN and H2NEW Data Hub

HydroGEN is a multi-lab consortium focused on early-stage R&D in H2 production, supported by the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Hydrogen and Fuel Cell Technologies Office (HFTO). The consortium advances research and development (R&D) of innovative materials for advanced water splitting (AWS) technologies to enable clean, sustainable and low-cost ($1/kg H2) hydrogen production and fosters cross-cutting innovation using theory-guided applied materials R&D to advance all emerging water-splitting pathways for hydrogen production. Hydrogen from Next-generation Electrolyzers of Water (H2NEW) is a consortium of nine U.S. Department of Energy (DOE) national laboratories focused on making large-scale electrolyzers, which produce hydrogen from electricity and water, more durable, efficient, and affordable. The presentation introduces the HydroGEN data hub to the H2NEW consortium and encourages H2NEW members to use it to store and share data with team members and eventually the public. The two consortia share this data hub.

advanced water splitting technologies↗

Using Leaf Chlorophyll to Parameterize Light-Use-Efficiency Within a Thermal-Based Carbon, Water and Energy Exchange Model

Chlorophylls absorb photosynthetically active radiation and thus function as vital pigments for photosynthesis, which makes leaf chlorophyll content (C(sub ab) useful for monitoring vegetation productivity and an important indicator of the overall plant physiological condition. This study investigates the utility of integrating remotely sensed estimates of C(sub ab) into a thermal-based Two-Source Energy Balance (TSEB) model that estimates land-surface CO2 and energy fluxes using an analytical, light-use-efficiency (LUE) based model of canopy resistance. The LUE model component computes canopy-scale carbon assimilation and transpiration fluxes and incorporates LUE modifications from a nominal (species-dependent) value (LUE(sub n)) in response to short term variations in environmental conditions, However LUE(sub n) may need adjustment on a daily timescale to accommodate changes in plant phenology, physiological condition and nutrient status. Day to day variations in LUE(sub n) were assessed for a heterogeneous corn crop field in Maryland, U,S.A. through model calibration with eddy covariance CO2 flux tower observations. The optimized daily LUE(sub n) values were then compared to estimates of C(sub ab) integrated from gridded maps of chlorophyll content weighted over the tower flux source area. The time continuous maps of daily C(sub ab) over the study field were generated by focusing in-situ measurements with retrievals generated with an integrated radiative transfer modeling tool (accurate to within +/-10%) using at-sensor radiances in green, red and near-infrared wavelengths acquired with an aircraft imaging system. The resultant daily changes in C(sub ab) within the tower flux source area generally correlated well with corresponding changes in daily calibrated LUE(sub n) derived from the tower flux data, and hourly water, energy and carbon flux estimation accuracies from TSEB were significantly improved when using C(sub ab) for delineating spatio-temporal variations in LUE(sub n). The results demonstrate the synergy between thermal infrared and shortwave reflective wavebands in producing valuable remote sensing data for operational monitoring of carbon and water fluxes.

Houlborg, Rasmus↗

Highly Efficient Surface Charge Transfer in Fe 2 TiO 5 Epitaxial Thin Film Photoanodes

Pseudobrookite (Fe 2 TiO 5 ) has attracted significant attention as an emerging photoanode for water oxidation due to reports of enhanced performance in polycrystalline heterostructures with α-Fe 2 O 3 or TiO 2 . However, the specific properties and contribution of Fe 2 TiO 5 remain unknown. Here, we present the first photoelectrochemical characterization of epitaxial thin film Fe 2 TiO 5 , an ideal platform for probing the inherent response of this earth-abundant photoanode for solar water splitting. Moreover, by using an electrolyte containing a hole scavenger, we find highly efficient charge transfer at the Fe 2 TiO 5 –electrolyte interface. This notable surface property is exploited in the form of an Fe 2 TiO 5 /α-Fe 2 O 3 heterostructure photoanode, for which we observe a photocurrent density increase by 1 order of magnitude and an onset potential improvement by ~300 mV. Establishing these fundamental properties elucidates the nature of reaction mechanisms on Fe 2 TiO 5 and informs the design of highly efficient water photo-oxidation devices by incorporating this material with other photoanodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗