SEARCH · Engineering Papers
Results for “volume determination”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A feasibility study of an experiment for determining the properties of the Mars atmosphere. Volume I - Summary
Mars probe design and subsystem performance characteristics for investigating Martian atmosphere
Results of an Investigation of the 0.003-scale Space Shuttle External Tank MSFC Model 460 in the NASA/MSFC 14 x 14-inch Trisonic Wind Tunnel to Determine Static Pressure Distributions During Reentry (TA2F), Volume 1
Objectives of the test were to obtain static pressure distributions for the ET at reentry conditions. Basic configuration of the model was the MCR 0200 ET modified to include a rectangular crossbar at the aft ET/orbiter attach point. Mach numbers were 1.96, 3.48, and 4.96. Reynolds number per foot at these Mach numbers were 6.95 million, 6.42 million, and 4.95 million, respectively. Angle of attack range was -8 to 100 degrees and roll angle was 0 to 315 degrees. Occupancy hours were 104.
Results of an investigation of the 0.003-scale space shuttle external tank MSFC model 460 in the NASA/MSFC 14 x 14 inch Trisonic Wind Tunnel to determine static pressure distributions during reentry (TA2F), volume 3
Static pressure distributions for the external tank (ET) at reentry conditions are presented. Basic configuration of the model was the MCR 0200 ET modified to include a rectangular crossbar at the aft ET/orbiter attach point. Mach numbers were 1.96, 3.48, and 4.96. Reynolds number per foot at these Mach numbers were 6.95 million, 6.42 million, and 4.95 million, respectively. Angle of attack range was -8 to 100 degrees and roll angle was 0 to 315 degrees.
An improved method for simultaneous determination of frictional pressure drop and vapor volume fraction in vertical flow boiling
The two-phase frictional pressure drop and vapor volume fraction in the vertical boiling and adiabatic flow of the refrigerant, R11, have been simultaneously measured by a liquid balancing column and differential magnetic reluctance pressure transducers. An account is given of the experimental apparatus and procedure, data acquisition and analysis, and error estimation employed. All values of two-phase multipliers evaluated on the basis of the measured frictional pressure drop data in vertical upflow fall in the range bounded by the predictions of the Chisholm correlation and the homogeneous model.
[{sup 18}F]fluoromisonidazole and a New PET System With Semiconductor Detectors and a Depth of Interaction System for Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer
Purpose: The impact of a new type of positron emission tomography (New PET) with semiconductor detectors using {sup 18}F-labeled fluoromisonidazole (FMISO)-guided intensity modulated radiation therapy (IMRT) was compared with a state-of-the-art PET/computed tomography (PET/CT) system in nasopharyngeal cancer (NPC) patients. Methods and Materials: Twenty-four patients with non-NPC malignant tumors (control group) and 16 patients with NPC were subjected to FMISO-PET. The threshold of the tumor-to-muscle (T/M) ratio in each PET scan was calculated. The hypoxic volume within the gross tumor volume (GTVh) was determined using each PET ({sub NewPET}GTVh and {sub PET/CT}GTVh, respectively). Dose escalation IMRT plans prescribing 84 Gy to each GTVh were carried out. Results: The threshold of the T/M ratio was 1.35 for New PET and 1.23 for PET/CT. The mean volume of {sub NewPET}GTVh was significantly smaller than that of {sub PET/CT}GTVh (1.5 {+-} 1.6 cc vs 4.7 {+-} 4.6 cc, respectively; P=.0020). The dose escalation IMRT plans using New PET were superior in dose distribution to those using PET/CT. Dose escalation was possible in all 10 New PET-guided plans but not in 1 PET/CT-guided plan, because the threshold dose to the brainstem was exceeded. Conclusions: New PET was found to be useful for accurate dose escalation in FMISO-guided IMRT for patients with NPC.
A Dirichlet process mixture model for automatic {sup 18}F-FDG PET image segmentation: Validation study on phantoms and on lung and esophageal lesions
Purpose: The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on {sup 18}F-fluorodeoxyglucose positron emission tomography ({sup 18}F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robustness. Methods: The DPM model belongs to the class of the Bayesian nonparametric models and uses the Dirichlet process prior for flexible nonparametric mixture modeling, without any preliminary choice of the number of mixture components. The DPM algorithm implemented in the statistical software package R was used in this work. The contouring accuracy was evaluated on several image data sets: on an IEC phantom (spherical inserts with diameter in the range 10–37 mm) acquired by a Philips Gemini Big Bore PET-CT scanner, using 9 different target-to-background ratios (TBRs) from 2.5 to 70; on a digital phantom simulating spherical/uniform lesions and tumors, irregular in shape and activity; and on 20 clinical cases (10 lung and 10 esophageal cancer patients). The influence of the DPM parameters on contour generation was studied in two steps. In the first one, only the IEC spheres having diameters of 22 and 37 mm and a sphere of the digital phantom (41.6 mm diameter) were studied by varying the main parameters until the diameter of the spheres was obtained within 0.2% of the true value. In the second step, the results obtained for this training set were applied to the entire data set to determine DPM based volumes of all available lesions. These volumes were compared to those obtained by applying already known algorithms (Gaussian mixture model and gradient-based) and to true values, when available. Results: Only one parameter was found able to significantly influence segmentation accuracy (ANOVA test). This parameter was linearly connected to the uptake variance of the tested region of interest (ROI). In the first step of the study, a calibration curve was determined to automatically generate the optimal parameter from the variance of the ROI. This “calibration curve” was then applied to contour the whole data set. The accuracy (mean discrepancy between DPM model-based contours and reference contours) of volume estimation was below (1 ± 7)% on the whole data set (1 SD). The overlap between true and automatically segmented contours, measured by the Dice similarity coefficient, was 0.93 with a SD of 0.03. Conclusions: The proposed DPM model was able to accurately reproduce known volumes of FDG concentration, with high overlap between segmented and true volumes. For all the analyzed inserts of the IEC phantom, the algorithm proved to be robust to variations in radius and in TBR. The main advantage of this algorithm was that no setting of DPM parameters was required in advance, since the proper setting of the only parameter that could significantly influence the segmentation results was automatically related to the uptake variance of the chosen ROI. Furthermore, the algorithm did not need any preliminary choice of the optimum number of classes to describe the ROIs within PET images and no assumption about the shape of the lesion and the uptake heterogeneity of the tracer was required.
Radial Internal Material Handling System (RIMS) for Circular Habitat Volumes
A Radial Internal Material Handling System (RIMS) has been developed to service a circular floor area in variable gravity. On planetary surfaces, pressurized human habitable volumes will require a means to carry heavy equipment between various locations within the volume of the habitat, regardless of the partial gravity (Earth, moon, Mars, etc). On the NASA Habitat Demonstration Unit (HDU), a vertical cylindrical volume, it was determined that a variety of heavy items would need to be carried back and forth from deployed locations to the General Maintenance Work Station (GMWS) when in need of repair, and other equipment may need to be carried inside for repairs, such as rover parts and other external equipment. The vertical cylindrical volume of the HDU lent itself to a circular overhead track and hoist system that allows lifting of heavy objects from anywhere in the habitat to any other point in the habitat interior. In addition, the system is able to hand off lifted items to other material handling systems through the side hatches, such as through an airlock. This paper describes the RIMS system which is scalable for application in a variety of circular habitat volumes.
Radial Internal Material Handling System (RIMS) for Circular Habitat Volumes
On planetary surfaces, pressurized human habitable volumes will require a means to carry equipment around within the volume of the habitat, regardless of the partial gravity (Earth, Moon, Mars, etc.). On the NASA Habitat Demonstration Unit (HDU), a vertical cylindrical volume, it was determined that a variety of heavy items would need to be carried back and forth from deployed locations to the General Maintenance Work Station (GMWS) when in need of repair, and other equipment may need to be carried inside for repairs, such as rover parts and other external equipment. The vertical cylindrical volume of the HDU lent itself to a circular overhead track and hoist system that allows lifting of heavy objects from anywhere in the habitat to any other point in the habitat interior. In addition, the system is able to hand-off lifted items to other material handling systems through the side hatches, such as through an airlock. The overhead system consists of two concentric circle tracks that have a movable beam between them. The beam has a hoist carriage that can move back and forth on the beam. Therefore, the entire system acts like a bridge crane curved around to meet itself in a circle. The novelty of the system is in its configuration, and how it interfaces with the volume of the HDU habitat. Similar to how a bridge crane allows coverage for an entire rectangular volume, the RIMS system covers a circular volume. The RIMS system is the first generation of what may be applied to future planetary surface vertical cylinder habitats on the Moon or on Mars.
SU-E-J-192: Verification of 4D-MRI Internal Target Volume Using Cine MRI
Purpose: To investigate the accuracy of 4D-MRI in determining the Internal Target Volume (ITV) used in radiation oncology treatment planning of liver cancers. Cine MRI is used as the standard baseline in establishing the feasibility and accuracy of 4D-MRI tumor motion within the liver. Methods: IRB approval was obtained for this retrospective study. Analysis was performed on MR images from four patients receiving external beam radiation therapy for liver cancer at our institution. Eligible patients received both Cine and 4D-MRI scans before treatment. Cine images were acquired sagittally in real time at a slice bisecting the tumor, while 4D images were acquired volumetrically. Cine MR DICOM headers were manipulated such that each respiratory frame was assigned a unique slice location. This approach permitted the treatment planning system (Eclipse, Varian Medical Systems) to recognize a complete respiratory cycle as a “volume”, where the gross tumor was contoured temporally. Software was developed to calculate the union of all frame contours in the structure set, resulting in the corresponding plane of the ITV projecting through the middle of the tumor, defined as the Internal Target Area (ITA). This was repeated for 4D-MRI, at the corresponding slice location, allowing a direct comparison of ITAs obtained from each modality. Results: Four patients have been analyzed. ITAs contoured from 4D-MRI correlate with contours from Cine MRI. The mean error of 4D values relative to Cine values is 7.67 +/− 2.55 %. No single ITA contoured from 4D-MRI demonstrated more than 10.5 % error compared to its Cine MRI counterpart. Conclusion: Motion management is a significant aspect of treatment planning within dynamic environments such as the liver, where diaphragmatic and cardiac activity influence plan accuracy. This small pilot study suggests that 4D-MRI based ITA measurements agree with Cine MRI based measurements, an important step towards clinical implementation. NIH 1R21CA165384-01A1.
Changes in Prostate Shape and Volume and Their Implications for Radiotherapy After Introduction of Endorectal Balloon as Determined by MRI at 3T
Purpose: To determine the changes in prostate shape and volume after the introduction of an endorectal coil (ERC) by means of magnetic resonance imaging (MRI) at 3T. Methods and materials: A total of 44 consecutive patients with biopsy-proven prostate cancer underwent separate MRI examinations at 3T with a body array coil and subsequently with an ERC inflated with 50 mL of fluid. Prospectively, two experienced readers independently evaluated all data sets in random order. The maximal anteroposterior, right-to-left, and craniocaudal prostate diameters, as well as the total prostate and peripheral zone and central gland volumes were measured before and after ERC introduction. The changes in prostate shape and volume were analyzed using Wilcoxon's test for paired samples. Results: The introduction of the ERC significantly changed the prostate shape in all three directions, with mean changes in the anteroposterior, right-to-left, and craniocaudal diameters of 15.7% (5.5 mm), 7.7% (3.5 mm), and 6.3% (2.2 mm), respectively. The mean total prostate, peripheral zone, and central gland volume decreased significantly after ERC introduction by 17.9% (8.3 cm{sup 3}), 21.6% (4.8 cm{sup 3}), and 14.2% (3.4 cm{sup 3}), respectively. Conclusion: ERC introduction as observed by 3T MRI changed the prostate shape and volume significantly. The mean anteroposterior diameter was reduced by nearly one-sixth of its original diameter, and the mean total prostate volume was decreased by approximately 18%. This could cause difficulties and should be considered when using ERC-based MRI for MRI-computed tomography fusion and radiotherapy planning.
Feasibility study of an optical radiometer for determining the composition of the Mars atmosphere from shock layer radiation during entry, volume II Final report
Optical radiometer feasibility study for determining composition of Mars atmosphere from shock layer radiation during entry - instrumentation
Dynamical insights into the mechanism of a droplet detachment from a fiber
Quantifying the detachment behavior of a droplet from a fiber is important in many applications such as fog harvesting, oil–water separation, or water management in fuel cells. When the droplets are forcibly removed from hydrophilic fibers, the ease of detachment strongly depends on droplet volume and the rate of the process controlled by the applied force. Experiments, conducted on a ferrofluid under magnetic force, as well as continuum level calculations from fluid mechanics have so far been unable to resolve the time-dependent dynamics of droplet detachment and, most importantly, to assess the role of the applied force as the key determinant of the volume of the droplet residue remaining on the fiber after detachment. In the present work, we study the mechanism of water droplet detachment and retention of residual water on smooth hydrophilic fibers using nonequilibrium molecular dynamics simulations. We investigate how the applied force affects the breakup of a droplet and how the minimal detaching force per unit mass decreases with droplet size. We extract scaling relations that allow extrapolation of our findings to larger length scales that are not directly accessible by molecular models. We find that the volume of the residue on a fiber varies nonmonotonically with the detaching force, reaching the maximal size at an intermediate force and associated detachment time. The strength of this force decreases with the size of the drop, while the maximal residue increases with the droplet volume, V, sub-linearly, in proportion to the V 2/3 .
Modeling the Effect of Glass Microballoon (GMB) Volume Fraction on Behavior of Sylgard/GMB Composites.
This work was done to support customer questions about whether a Sylgard/Glass Microballoon (GMB) potting material in current use could be replaced with pure Sylgard and if this would significantly change stresses imparted to internal components under thermal cycling conditions. To address these questions, we provide micromechanics analysis of Sylgard/GMB materials using both analytic composite theory and finite element simulations to better understand the role of the GMB volume fraction in determining thermal expansion coefficient, elastic constants, and behavior in both confined and unconfined compression boundary value problems. A key finding is that damage accumulation in the material from breakage of GMBs significantly limits the global stress magnitude and results in a plateau stress behavior over large ranges of compressive strain. The magnitude of this plateau stress is reduced with higher volume fractions of GMBs. This effect is particularly pronounced in confined compression, which we estimate bears the most similarity to the application of interest. This stress-limiting damage mechanism is not present in pure Sylgard, however, and the result is much higher stresses under confined compression. Thus, we recommend that some volume fraction greater than 10% GMBs be used for confined deformation applications.
Lipiodol: A Potential Direct Surrogate for Cone-Beam Computed Tomography Image Guidance in Radiotherapy of Liver Tumor
Purpose: To investigate the feasibility of using lipiodol as a direct surrogate for target localization using cone-beam CT (CBCT) image guidance in radiotherapy (RT) of patients with unresectable liver tumors after transarterial chemoembolization. Methods and Materials: Forty-six patients with an unresectable solitary liver tumor were enrolled for RT using active breathing control (ABC) and CBCT image guidance after transarterial chemoembolization. Each patient had pre- and posttreatment CBCT in the first 10 fractions of treatment. Lipiodol retention was evaluated using daily CBCT scans, and volume of lipiodol retention in the liver was calculated and compared between planning CT and post-RT CT. Influence of lipiodol on dosimetry was evaluated by measuring doses using an ion chamber with and without the presence of lipiodol. Margin analysis was performed on the basis of both inter- and intrafractional target localization errors. Results: Twenty-eight patients successfully completed the study. The shape and size of lipiodol retention did not vary substantially during the course of treatment. The mean Dice similarity coefficient for the lipiodol volume in pretreatment CT and that in posttreatment CT was 0.836 (range, 0.817-0.885). The maximum change (ratio of the lipiodol volume in pretreatment CT to that in posttreatment CT) was 1.045. The mean dose changes with the presence of <10 mL lipiodol were -1.44% and 0.13% for 6 MV and 15 MV, respectively. With ABC and online CBCT image guidance, clinical target volume-planning target volume margins were determined to be 2.5 mm in the mediolateral direction, 2.9 mm in the anteroposterior direction, and 4.0 mm in the craniocaudal direction. Conclusions: Lipiodol could be used as a direct surrogate for CBCT image guidance to improve the localization accuracy for RT of liver tumors. Combination of ABC and CBCT image guidance with lipiodol can potentially reduce the clinical target volume-planning target volume margin.