At least 469 records · Page 26

Enabling high areal capacity for Co-free high voltage spinel materials in next-generation Li-ion batteries

The rapidly growing technological demand for lithium-ion batteries has prompted the development of novel cathode materials with high energy density, low cost, and improved safety. High voltage spinel, LiNi 0.5 Mn 1.5 O 4 (LNMO), is one of the most promising candidates yet to be commercialized. The two primary obstacles for this material are the inferior electronic conductivity and fast capacity degradation in full cells due to the high operating voltage. By systematically addressing these limitations, we successfully develop a thick LNMO electrode with areal capacity loadings up to 3 mAh·cm –2 . The optimized thick electrode is paired with a commercial graphite anode at both the coin cell and pouch cell level, achieving a full cell capacity retention as high as 72% and 78%, respectively, after 300 cycles. We attribute this superior cycling stability to careful optimizations of cell components and testing conditions, with a specific focus improving electronic conductivity and high voltage compatibility. These results suggest precise control of materials quality, electrode architecture and electrolyte optimization can soon support the development of a cobalt-free battery system based on a thick LNMO cathode (>4 mAh·cm 2 ), which will eventually meet the needs of next-generation Li-ion batteries with reduced cost, improved safety, and assured sustainability.

25 ENERGY STORAGE↗

Evidence of Universal Temperature Scaling in Self-Heated Percolating Networks

During routine operation, electrically percolating nanocomposites are subjected to high voltages, leading to spatially heterogeneous current distribution. The heterogeneity implies localized self-heating that may (self-consistently) reroute the percolation pathways and even irreversibly damage the material. In the absence of experiments that can spatially resolve the current distribution and a nonlinear percolation model suitable to interpret them, one relies on empirical rules and safety factors to engineer these materials. In this paper, we use ultrahigh resolution thermo-reflectance imaging, coupled with a new imaging processing technique, to map the spatial distribution ΔT(x, y; I) and histogram f(ΔT) of temperature rise due to self-heating in two types of 2D networks (percolating and copercolating). Remarkably, we find that the self-heating can be described by a simple two-parameter Weibull distribution, even under voltages high enough to reconfigure the percolation pathways. Given the generality of the phenomenological argument supporting the distribution, other percolating networks are likely to show similar stress distribution in response to sufficiently large stimuli. Furthermore, the spatial evolution of the self-heating of network was investigated by analyzing the spatial distribution and spatial correlation, respectively. An estimation of degree of hotspot clustering reveals a mechanism analogous to crystallization physics. Lastly, the results should encourage nonlinear generalization of percolation models necessary for predictive engineering of nanocomposite materials.

42 ENGINEERING↗

High resolution energy analyzer for broad ion beam characterization

Characterization of the ion energy distribution function (IEDF) of low energy high current density ion beams by conventional retarding field and deflection type energy analyzers is limited due to finite ion beam emittance and beam space charge spreading inside the analyzer. These deficiencies are, to a large extent, overcome with the recent development of the variable-focusing retarding field energy analyzer (RFEA), which has a cylindrical focusing electrode preceding the planar retarding grid. The principal concept of this analyzer is conversion of a divergent charged particle beam into a quasiparallel beam before analyzing it by the planar retarding field. This allows analysis of the beam particle total kinetic energy distribution with greatly improved energy resolution. Whereas this concept was first applied to analyze 5-10 keV pulsed electron beams, the present authors have adapted it to analyze the energy distribution of a low energy ({<=}1 KeV) broad ion beam. In this paper we describe the RFEA design, which was modified from the original, mainly as required by the specifics of broad ion beam energy analysis, and the device experimental characterization and modeling results. Among the modifications, an orifice electrode placed in front of the RFEA provides better spatial resolution of the broad ion beam ion optics emission region and reduces the beam plasma density in the vicinity of analyzer entry. An electron repeller grid placed in front of the RFEA collector was found critical for suppressing secondary electrons, both those incoming to the collector and those released from its surface, and improved energy spectrum measurement repeatability and accuracy. The use of finer mesh single- and double-grid retarding structures reduces the retarding grid lens effect and improves the analyzer energy resolution and accuracy of the measured spectrum mean energy. However, additional analyzer component and configuration improvements did not further change the analyzed IEDF shape or mean energy value. This led us to conclude that the optimized analyzer construction provides an energy resolution considerably narrower than the investigated ion beam energy spectrum full width at half maximum, and the derived energy spectrum is an objective and accurate representation of the analyzed broad ion beam energy distribution characteristics. A quantitative study of the focusing voltage and retarding grid field effects based on the experimental data and modeling results have supported this conclusion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical analysis of the ion beam production in a self magnetically insulated diode

The paper presents the results of a study on shot to shot variation in energy density of an ion beam formed by a self-magnetically insulated diode with an explosive emission cathode. The experiments were carried out with the TEMP-4M accelerator operating in double-pulse mode: plasma formation occurs during the first pulse (negative polarity, 300–500 ns, 100–150 kV), and ion extraction and acceleration during the second pulse (positive polarity, 150 ns, 250–300 kV). Crucially, it was found that the standard deviation of energy density does not exceed 11%, whilst the same variation for ion current density was 20%–30%, suggesting the presence of neutrals in the beam. This idea is further supported by the fact that ion current density is only weakly dependant on the accelerating voltage and other output parameters of the accelerator (coefficient of determination < 0.3), whilst the correlation between the energy density of the beam and the output parameters is strong (coefficient of determination > 0.9). We attribute the neutral component as being due to charge exchange between accelerated ions and neutral molecules from a neutral layer near the anode surface. Implementation using a self-magnetically insulated diode with an explosive-emission cathode, having an operational lifetime of up to 10{sup 7} shots, has promising prospects for various technological applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robust Medium-Voltage Distribution System State Estimation using Multi-Source Data

Due to the lack of sufficient online measurements for distribution system observability, pseudo-measurements from short-term load or distributed renewable energy resources (DERs) forecasting are used. However, the accuracy of them is low and thus significantly limits the performance of distribution system state estimation (DSSE). In this paper, a robust DSSE that integrates multi-source measurement data is proposed. Specifically, the historical low-voltage (LV) side smart meters are used to forecast load and DERs injections via the support vector machine (SVM) with optimally tuned parameters. By contrast, the online smart meters at LV side are utilized to derive equivalent power injections at the MV/LV transformers, yielding more accurate pseudo-measurements compared to the forecasted injections. Furthermore, to deal with bad data caused by communication loss, instrumental errors and cyber attacks, robust DSSE that relies on generalized maximum-likelihood (GM)-estimation criterion is developed. The projection statistics are developed to adjust the weights of each measurement, leading to better balance between pseudo- and real-time measurements. Numerical results conducted on modified IEEE 33-bus system with DG integration demonstrate the effectiveness and robustness of the proposed method.

distribution system state estimation↗

Insights into PEMFC Performance Degradation from HCl in Air

The performance degradation of a proton exchange membrane fuel cell (PEMFC) is studied in the presence of HCl in the air stream. The cathode employing carbon-supported platinum nanoparticles (Pt/C) was exposed to 4 ppm HCl in air while the cell voltage was held at 0.6 V. The HCl poisoning results in generation of chloride and chloroplatinate ions on the surface of Pt/C catalyst as determined by a combination of electrochemical tests and ex-situ chlorine K-edge X-Ray absorption near-edge structure (XANES) spectroscopy. The chloride ions inhibit the oxygen reduction reaction (ORR) and likely affect the wetting properties of diffusion media/catalyst layer, while the chloroplatinate ions are responsible for enhanced platinum particle growth most likely due to platinum dissolution-redeposition. The chloride ions can cause corrosion of the Pt nanoparticles in the presence of aqueous HCl in air even if no potential is applied. Although the majority of chloride ions are desorbed from the Pt surface by hydrogen treatment of the cathode, they partially remain in the system and re-adsorb on platinum at cell voltages of 0.5-0.9 V. Chloride ions are removed from the system and fuel cell performance at 0.5-0.7 V is restored by multiple exposures to low potentials.

08 HYDROGEN↗

Final Report: Thin Silicon Solar Cells - A Path to 35% Shockley-Queisser Limits

Carrier selective contacts have revolutionized efficiencies of silicon solar cell, with the most recent efficiencies showing 26.3% efficiency. The project has substantially advanced the understanding and state of the art in carrier selective contacts, providing experimental and conceptual advances. Additionally, over the course of the project, there has been increasing interest on the development of silicon based tandems, and the project provided several critical advances that support the development of silicon-based tandems. Key outcomes of the project include: Highest voltage from a carrier selective contact solar cell Demonstration of GaP as a selective carrier contact, using intrinsic a-Si as a membrane layer Demonstration of highest efficiency solar cell using MoOx as a carrier selective contact Fundamental processes in the carrier selective contacts, including advances in understanding transport in carrier selective contact Identification of processes and approaches to circumvent minority carrier lifetime degradation of silicon during growth of III-V’s on silicon Demonstration of approaches to improve absorption in solar cells using improved rear reflectors Improved understanding of processes that control the FF of a solar cell First demonstration of a GaP/Si heterostructure solar cell using GaP as a hetero-emitter

14 SOLAR ENERGY↗

Synchrophasor Visual Integration and Event Evaluation for Utilities (SynchroVIEEU) with High Penetration of Renewables

The Hawaiian Electric Companies (Companies), operating independent grid systems on the islands of Oahu, Hawaii, Maui, Molokai and Lanai, have been contending with some of the highest levels of renewable generation from both utility-scale and distributed generation resources. Renewable penetration levels exceeding 50% of generation are some of the highest in the nation and are changing the system characteristics and requiring operational changes to grid management. The Companies have aggressively leveraged federal, multi-state and industry grant funding to demonstrate new technologies for monitoring, visualization, forecasting and analysis to inform transformation needs and to improve operational awareness, especially at the distribution level. As part of the American Recovery and Reinvestment Act (ARRA) supported efforts to facilitate integration of renewables, synchrophasor devices were deployed on the islands of Hawaii and Maui in 2010. The devices have potential to provide Hawaii Electric Light Company (HELCO) on Hawaii Island and Maui Electric Company (MECO) with additional information to support post-event analysis and to help quantify observed area-wide changes in voltage and frequency on the systems. Consistent with the U.S. Department of Energy’s (DOE) Office of Electricity Delivery and Energy Reliability (OE) FOA objectives, the goal of this project was to accelerate the integration of synchrophasor information into production grade data visualization and analysis platforms/models to inform timely, efficient and reliable operations of a modern grid in light of high penetrations of renewable resources. The project comprised a two-year development effort to investigate the integration and visualization of synchrophasor field data into production-ready transmission and distribution proactive modeling efforts and a common data analysis platform application currently being used by the Companies. Conceptually, the project was about getting the right data to the right people at the right time in an easily accessible and timely environment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring Mixed Ionic–Electronic-Conducting PVA/PEDOT:PSS Hydrogels as Channel Materials for Organic Electrochemical Transistors

Here, we report the preparation and evaluation of PVA/PEDOT:PSS-conducting hydrogels working as channel materials for OECT applications, focusing on the understanding of their charge transport and transfer properties. Our conducting hydrogels are based on crosslinked PVA with PEDOT:PSS interacting via hydrogen bonding and exhibit an excellent swelling ratio of ~180–200% w/w. Our electrochemical impedance studies indicate that the charge transport and transfer processes at the channel material based on conducting hydrogels are not trivial compared to conducting polymeric films. The most relevant feature is that the ionic transport through the swollen hydrogel is clearly different from the transport through the solution, and the charge transfer and diffusion processes govern the low-frequency regime. In addition, we have performed in operando Raman spectroscopy analyses in the OECT devices supported by first-principle computational simulations corroborating the doping/de-doping processes under different applied gate voltages. The maximum transconductance (gm~1.05 μS) and maximum volumetric capacitance (C*~2.3 F.cm -3 ) values indicate that these conducting hydrogels can be promising candidates as channel materials for OECT devices.

36 MATERIALS SCIENCE↗

Space environmental effects and the solar power satellite

Some preliminary findings regarding the interactions between the space plasma at GEO and the Marshall Space Flight Center January 1978 baseline Satellite Power Systems (SPS) design are summarized. These include the following: (1) the parasitic load will be dominated by photoelectrons and will amount to about 34 MW; (2) material of higher conductivity than kapton should be used for the solar reflector substrate and the solar cell blanket support material; (3) the satellite structure and solar reflector should be tied electrically to midpoint voltage of each solar cell array; and (4) tests should be run on the proposed solar cell cover glass material (synthetic sapphire) to determine if breakdown is expected.

Freeman, J. W.↗

Fault detection in digital and analog circuits using an i(DD) temporal analysis technique

An i(sub DD) temporal analysis technique which is used to detect defects (faults) and fabrication variations in both digital and analog IC's by pulsing the power supply rails and analyzing the temporal data obtained from the resulting transient rail currents is presented. A simple bias voltage is required for all the inputs, to excite the defects. Data from hardware tests supporting this technique are presented.

Beasley, J.↗

Scalable Distributed Automation System: Scalable Real-time Decentralized Volt/VAR Control

GENI Project: Caltech is developing a distributed automation system that allows distributed generators—solar panels, wind farms, thermal co-generation systems—to effectively manage their own power. To date, the main stumbling block for distributed automation systems has been the inability to develop software that can handle more than 100,000 distributed generators and be implemented in real time. Caltech’s software could allow millions of generators to self-manage through local sensing, computation, and communication. Taken together, localized algorithms can support certain global objectives, such as maintaining the balance of energy supply and demand, regulating voltage and frequency, and minimizing cost. An automated, grid-wide power control system would ease the integration of renewable energy sources like solar power into the grid by quickly transmitting power when it is created, eliminating the energy loss associated with the lack of renewable energy storage capacity of the grid.

ARPA-E↗

Preparation of supported electrocatalyst comprising multiwalled carbon nanotubes

A process for preparing a durable non-precious metal oxygen reduction electrocatalyst involves heat treatment of a ball-milled mixture of polyaniline and multiwalled carbon nanotubes in the presence of a Fe species. The catalyst is more durable than catalysts that use carbon black supports. Performance degradation was minimal or absent after 500 hours of operation at constant cell voltage of 0.40 V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Opportunities for Utilizing the International Space Station for Studies of F2- Region Plasma Science and High Voltage Solar Array Interactions with the Plasma Environment

The near circular, 51.6deg inclination orbit of the International Space Station (ISS) is maintained within an altitude range of approximately 300 km to 400 km providing an ideal platform for conducting in-situ studies of space weather effects on the mid and low-latitude F-2 region ionosphere. The Floating Potential Measurement Unit (FPMU) is a suite of instruments installed on the ISS in August 2006 which includes a Floating Potential Probe (FPP), a Plasma Impedance Probe (PIP), a Wide-sweep Langmuir Probe (WLP), and a Narrow-sweep Langmuir Probe (NLP). The primary purpose for deploying the FPMU is to characterize ambient plasma temperatures and densities in which the ISS operates and to obtain measurements of the ISS potential relative to the space plasma environment for use in characterizing and mitigating spacecraft charging hazards to the vehicle and crew. In addition to the engineering goals, data from the FPMU instrument package is available for collaborative multi-satellite and ground based instrument studies of the F-region ionosphere during both quiet and disturbed periods. Finally, the FPMU measurements supported by ISS engineering telemetry data provides a unique opportunity to investigate interactions of the ISS high voltage (160 volt) solar array system with the plasma environment. This presentation will provide examples of FPMU measurements along the ISS orbit including night-time equatorial plasma density depletions sampled near the peak electron density in the F2-region ionosphere, charging phenomenon due to interaction of the ISS solar arrays with the plasma environment, and modification of ISS charging due to visiting vehicles demonstrating the capabilities of the FPMU probes for monitoring mid and low latitude plasma processes as well as vehicle interactions with the plasma environment.

Minow, Joseph I.↗

High-voltage space-plasma interactions measured on the PASP Plus test arrays

The Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) experiment was developed by the Air Force's Phillips Laboratory with support from NASA's Lewis Research Center. It was launched on the Advanced Photovoltaic and Electronics EXperiments (APEX) satellite on August 3, 1994 into a 70 degree inclination, 363 km by 2550 km elliptical orbit. This orbit allows the investigation of space plasma effects on high-voltage operation (leakage current at positive voltages and arcing at negative voltages) in the perigee region. PASP Plus is testing twelve solar arrays. There are four planar Si arrays: an old standard type (used as a reference), the large-cell Space Station Freedom (SSF) array, a thin 'APSA' array, and an amorphous Si array. Next are three GaAs on Ge planar arrays and three new material planar arrays, including InP and two multijunction types. Finally, there are two concentrator arrays: a reflective-focusing Mini-Cassegrainian and a Fresnel-lens focusing Mini-Dome. PASP Plus's diagnostic sensors include: Langmuir probe to measure plasma density, an electrostatic analyzer (ESA) to measure the 30 eV to 30 KeV electron/ion spectra and determine vehicle negative potential during positive biasing, and a transient pulse monitor (TPM) to characterize the arcs that occur during the negative biasing. Through positive biasing of its test arrays, PASP Plus investigated the snapover phenomenon, which took place over the range of +100 to +300 V. It was found that array configurations where the interconnects are shielded from the space plasma (i.e., the concentrators or arrays with 'wrap-through' connectors) have lower leakage current. The concentrators exhibited negligible leakage current over the whole range up to +500 V. In the case of two similar GaAs on Ge arrays, the one with 'wrap-through' connectors had lower leakage current than the one with conventional interconnects. Through negative biasing, PASP Plus investigated the arcing rates of its test arrays. The standard Si array, with its old construction (exposed rough-surface interconnects), arced significantly over a wide voltage and plasma-density range. The other arrays arced at very low rates, mostly at voltages greater than -350 V and plasma densities near or greater than 10(exp 5)/cm(exp -3). AS expected according to theory, arcing was more prevalent when array temperatures were cold (based on biasing in eclipse).

Guidice, Donald A.↗

Estimation of solar photovoltaic energy curtailment due to volt–watt control

The widespread deployment of autonomous inverter‐based solutions for mitigating voltage and frequency excursions caused by high‐penetration photovoltaic (PV) systems has drawn increased attention due to their potential impact on PV production. It is now important to quantify the amount of solar energy curtailed as a result of the activation of inverter‐based grid support functions (GSFs). This study proposes a methodology for estimating the impact of volt–watt on customer PV energy curtailment using smart meter voltage data. This method estimates maximum possible curtailment for a given volt–watt curve based on the customer smart meter voltage during the time period of interest. This study compares the proposed methodology with field measurements using irradiance and customer inverter data from Hawaii as well as with results from a previous simulation‐driven study on the impact of advanced inverter GSF activation on PV energy curtailment. Results show that the proposed method for estimating lost PV production caused by volt–watt control aligns reasonably well with field measurements and computer simulations for hundreds of customers. The proposed method could be used to estimate customer energy curtailment, which could inform future compensation mechanisms for utilities leveraging customer‐sited resources to mitigate high voltage and defer infrastructure upgrades.

Emmanuel, Michael↗

High-Platinum-Content Catalysts on Atomically Dispersed and Nitrogen Coordinated Single Manganese Site Carbons for Heavy-Duty Fuel Cells

Fuel cells for heavy-duty vehicles (HDVs) have attracted considerable attention because of their unique scalability, better fuel economy, the less demand for hydrogen refilling infrastructure. However, the potential application requires more stringent fuel cell durability up to 25,000 h. Membrane electrode assemblies (MEAs) made from platinum group metal (PGM) catalyst with relatively high loading 0.3 mgPt cm –2 play a crucial role in ensuring high-power and long-term durability. Integrating fine PGM nanoparticles and robust carbon support with strengthened interactions is critical for improving MEA performance and durability. Herein, a unique atomically dispersed and nitrogen coordinated single Mn site-rich carbon (M–N–C) support was developed for high content (40 wt%) platinum catalysts for the oxygen reduction reaction (ORR) cathode with reduced thickness. Compared with two controls studied in this work (e.g., a porous graphitic carbon-supported Pt and a commercial TKK Pt/C catalysts), the Pt (40 wt%)/Mn–N–C catalyst exhibited much enhanced catalytic activity and stability for the ORR in both aqueous acidic electrolyte and polymer electrolyte-based MEA. Here, we carefully elucidated the—role of the Mn–N–C support in promoting Pt catalyst concerning its high surface area, partially graphitic structure, and nitrogen dopants, providing better Pt nanoparticle dispersion, and strengthened interactions between Pt and carbon. Consequently, the MEA from the Pt (40 wt%)/Mn–N–C catalyst generated a 1.61 A cm –2 at 0.7 V based on HDV conditions (0.2 mgPt cm –2 and 250 kPa air). More importantly, the MEA is highly durable and can retain 1.31 A cm –2 at 0.7 V after 30,000 voltage cycles (~19% loss), surpassing the commercial Pt/C catalyst (loss of ~56%). Therefore, the Mn–N–C carbon-supported Pt catalyst holds a great promise to meet the challenging DOE target (1.07 A cm –2 at 0.7 V after 150,000 cycles) for HDVs.

25 ENERGY STORAGE↗

A Rh x S y /C Catalyst for the Hydrogen Oxidation and Hydrogen Evolution Reactions in HBr

Rhodium sulfide (Rh 2 S 3 ) on carbon support was synthesized by refluxing rhodium chloride with ammonium thiosulfate. Thermal treatment of Rh 2 S 3 at high temperatures (600°C to 850°C) in presence of argon resulted in the transformation of Rh 2 S 3 into Rh 3 S 4 , Rh 17 S 15 and Rh which were characterized by TGA/DTA, XRD, EDX, and deconvolved XPS analyses. The catalyst particle size distribution ranged from 3 to 12 nm. Cyclic voltammetry and rotating disk electrode measurements were used to evaluate the catalytic activity for hydrogen oxidation and evolution reactions in H 2 SO 4 and HBr solutions. The thermally treated catalysts show high activity for the hydrogen reactions. The exchange current densities (i o ) of the synthesized Rh x S y catalysts in H 2 -saturated 1M H 2 SO 4 and 1M HBr for HER and HOR were 0.9 mA/cm 2 to 1.0 mA/cm 2 and 0.8 to 0.9 mA/cm 2 , respectively. The lower i o values obtained in 1M HBr solution compared to in H 2 SO 4 might be due to the adsorption of Br - on the active surface. Stable electrochemical active surface area (ECSA) of Rh x S y catalyst was obtained for CV scan limits between 0 V and 0.65 V vs. RHE. Scans with upper voltage limit beyond 0.65 V led to decreased and unreproducible ECSA measurements.

25 ENERGY STORAGE↗