Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultrasonic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Improved Ultrasonic Transducer For Measuring Cryogenic Flow

Improved ultrasonic transducer used to measure flow of cryogenic fluid. Includes wedge made nonintrusive by machining it out of bulk material of duct carrying fluid. Skewed surfaces of wedge suppress standing waves, thus reducing ringing and increasing signal-to-noise ratio. Increases accuracy of measurements of times of arrival of ultrasonic pulses, from which times flow inferred.

Barkhoudarian, Sarkis↗

A physical model for the acousto-ultrasonic method

A basic physical explanation, a model, and comments on NDE application of the acousto-ultrasonic (AU) method for composite materials are presented. The basis of this work is a set of experiments where a sending and a receiving piezoelectric transducer were both oriented normal to the surface, at different points, on aluminum plates, various composite plates, and a tapered aluminum plate. The purpose and basic idea is introduced. Also, general comments on the AU method are offered. A literature review is offered for areas pertinent, such as composite materials, wave propagation, ultrasonics, and the AU. Special emphasis is given to theory which is used later on and past experimental results that are important to the physical understanding of the AU method. The experimental set-up, procedure, and the ensuing analysis are described. The experimental results are presented in both a quantitative and qualitative manner. A physical understanding of experimental results based on elasticity solution is furnished. Modeling and applications of the AU method is discussed for composite material and general conclusions are stated. The physical model of the AU method for composite materials is offered, something which has been much needed and sorely lacking. This physical understanding is possible due to the extensive set of experimental measurements, also reported.

Kiernan, Michael T.↗

NOVA 201 ultrasonic thickness gage (NOVA Gage)

The measurement integrity of the NOVA 201 digital ultrasonic thickness gage (NOVA gage) was demonstrated by comparing the NOVA gage measurements to the thickness gage measurements, and determining the bias and uncertainty of the NOVA gage when measuring redesigned solid rocket motor (RSRM) hardware per engineering test plans (ETP). The NOVA gage was tested by three different operators on steel and aluminum RSRM hardware for wall thickness. The results show that the measurement bias is not consistent. The uncertainty of the bias is caused by the heterogeneous material properties of the RSRM components that influence the time of flight of ultrasonic waves. The measurement uncertainty inherent to the design and operation of the NOVA gage is less in comparison to the uncertainty of the bias. The total measurement uncertainty cannot be substantially reduced by taking more than one measurement. There is no correlation between bias and the surface finish range of this test unless 3-in-One oil is used as a couplant, in which case there appears to be a slight trend. There is no correlation between uncertainty and the surface finish range. The measurement uncertainty of the NOVA gage can be reduced using 3-in-One oil as a couplant.

Garecht, Diane↗

Acousto-ultrasonic evaluation of ceramic matrix composite materials

Acousto-ultrasonic nondestructive evaluation of ceramic composite specimens with a lithium-alumino-silicate glass matrix reinforced with unidirectional silicon carbide (NICALON) fibers was conducted to evaluate their reserve of strength. Ceramic composite specimens with different amount of damage were prepared by four-point cyclic fatigue loading of the specimens at 500 C for a different number of cycles. The reserve of strength of the specimens was measured as the maximum bending stress recorded during four-pointed bending test with the load monotonically increased until failure occurs. It was observed that the reserve of strength did not correlate with the number of fatigue cycles. However, it was also observed that higher values of the stress wave factor measurements correspond to higher values of the reserve of strength test data. Therefore, these results show that the acousto-ultrasonic approach has the potential of being used to monitor damage and to estimate the reserve of strength of ceramic composites.

Dosreis, Henrique L. M.↗

Spatial variations in ac susceptibility and microstructure for the YBa2Cu3O(7-x) superconductor and their correlation with room-temperature ultrasonic measurements

The spatial (within-sample) uniformity of superconducting behavior and microstructure in YBa2Cu3O(7-x) specimens over the pore fraction range of 0.10 to 0.25 was examined. The viability of using a room-temperature, nondestructive characterization method (ultrasonic velocity imaging) to predict spatial variability was determined. Spatial variations in superconductor properties were observed for specimens containing 0.10 pore fraction. An ultrasonic velocity image constructed from measurements at 1 mm increments across one such specimen revealed microstructural variation between edge and center locations that correlated with variations in alternating-current shielding and loss behavior. Optical quantitative image analysis on sample cross-sections revealed pore fraction to be the varying microstructural feature.

Roth, Don J.↗

Ultrasonic imaging of textured alumina

Ultrasonic images representing the bulk attenuation and velocity of a set of alumina samples were obtained by a pulse-echo contact scanning technique. The samples were taken from larger bodies that were chemically similar but were processed by extrusion or isostatic processing. The crack growth resistance and fracture toughness of the larger bodies were found to vary with processing method and test orientation. The results presented here demonstrate that differences in texture that contribute to variations in structural performance can be revealed by analytic ultrasonic techniques.

Stang, D. B.↗

Acousto-ultrasonics - Retrospective exhortation with bibliography

Major research on the acousto-ultrasonic (AU) technique (also known as the stress-wave-factor technique) encompassing aspects of acoustic emission and ultrasonic materials characterization methodology is reviewed. AU deals primarily with such factors as the assessment of the integrated effects of diffuse defect states, thermomechanical degradation, and population of subcritical flaws that influence AU measurements correlating with mechanical property variations. AU is used to evaluate fiber-reinforced composites, adhesive bonds, lumber, paper and wood products, cable and rope, and human bone. The AU technique has been demonstrated to be sensitive to interlaminar and adhesive bond strength variations and has been shown to be useful in assessing microporosity and microcracking produced by fatigue cycling. An extensive bibliography ranging from 1985 to 1991 is presented.

Vary, Alex↗

Noncontact acousto-ultrasonics using laser generation and laser interferometric detection

A compact, portable fiber-optic heterodyne interferometer designed to detect out-of-plane motion on surfaces is described. The interferometer provides a linear output for displacements over a broad frequency range and can be used for ultrasonic, acoustic emission, and acousto-ultrasonic (AU) testing. The interferometer in conjunction with a compact pulsed Nd:YAG laser represents a noncontact testing system. This system was tested to determine its usefulness for the AU technique. The results obtained show that replacement of conventional piezoelectric transducers (PZT) with a laser generation/detection system make it possible to carry out noncontact AU measurements. The waveforms recorded were 5 MHZ PZT-generated ultrasound propagating through an aluminum block, detection of the acoustic emission event, and laser AU waveforms from graphite-epoxy laminates and a filament-wound composite.

Green, Robert E., Jr.↗

Constant frequency pulsed phase-locked-loop instrument for measurement of ultrasonic velocity

A new instrument based on a constant-frequency pulsed phase-locked-loop (CFPPLL) concept has been developed to accurately measure the ultrasonic wave velocity in liquids and changes in ultrasonic wave velocity in solids and liquids. An analysis of the system shows that it is immune to many of the frequency-dependent effects that plague other techniques. Measurements of the sound velocity in ultrapure water are used to confirm the analysis. The results are in excellent agreement with values from the literature, and establish that the CFPPLL provides a reliable, accurate way to measure velocities, as well as for monitoring small changes in velocity without the sensitivity to frequency-dependent phase shifts common to other measurement systems. The estimated sensitivity to phase changes is better than a few parts in 10 to the 7th.

Yost, William T.↗

Spatial variations in a.c. susceptibility and microstructure for the YBa2Cu3O(7-x) superconductor and their correlation with room-temperature ultrasonic measurements

The spatial (within-sample) uniformity of superconducting behavior and microstructure in YBa2Cu30(7-x) specimens over the pore fraction range of 0.10 to 0.25 was examined. The viability of using a room-temperature, nondestructive characterization method (ultrasonic velocity imaging) to predict spatial variability was determined. Spatial variations in superconductor properties were observed for specimens containing 0.10 pore fraction. An ultrasonic velocity image constructed from measurements at 1 mm increments across one such specimen revealed microstructural variation between edge and center locations that correlated with variations in alternating-current shielding and loss behavior. Optical quantitative image analysis on sample cross-sections revealed pore fraction to be the varying microstructural feature.

Roth, Don J.↗

Ultrasonic nondestructive evaluation of graphite epoxy composite laminates

Quantitative ultrasonic techniques are summarized with applications to the measurement of frequency-dependent attenuation and backscatter and to the NDE of composite laminates. Results are listed for the ultrasonic NDE of graphite-epoxy composite laminates including impact and fatigue damage as well as porosity. The methods reviewed include transmission measurements of attenuation, reconstructive tomography based on attenuation, estimating attenuation from backscattered ultrasound, and backscatter approaches. Phase-sensitive and -insensitive detection techniques are mentioned such as phase cancellation at piezoelectric receiving transducers and acoustoelectric effects. The techniques permit the NDE of the parameters listed in inhomogeneous media and provide both images from the transmission mode and in the reflection mode.

Miller, James G.↗

Gel-Filled Holders For Ultrasonic Transducers

In new technique, ultrasonic transducer embedded in rubbery, castable, low-loss gel to enable transducer to "look" into surface of test object or human body at any desired angle. Composed of solution of water and ethylene glycol in collagen matrix. Provides total contact of water bath, also used on bodies or objects too large for water baths, even if moving. Also provides look angles of poly(methyl methacrylate) angle block with potential of reduced acoustic impedance and refraction. Custom-tailored to task at hand, and gel sufficiently inexpensive to be discarded upon completion. Easy to couple ultrasound in and out of gel, minimizing losses and artifacts of other types of standoffs employed in ultrasonic testing.

Companion, John A.↗

Sparsely Sampled Phase-Insensitive Ultrasonic Transducer Arrays

Three methods of interpretation of outputs from sparsely sampled two-dimensional array of receiving ultrasonic transducers used in transmission experiments investigated. Methods are: description of sampled beam in terms of first few spatial moments of sampled distribution of energy; use of signal-dependent cutoff to limit extent of effective receiver aperture; and use of spatial interpolation to increase apparent density of sampling during computation. Methods reduce errors in computations of shapes of ultrasonic beams.

Patrick H. Johnston↗

Ultrasonic Detection Of Transverse Cracks In Composites

Conventional ultrasonic C scan used to detect flaws in graphite/epoxy composite panels modified to enhance sensitivity to transverse cracks. Modification involves reorientation and repositioning of ultrasonic transmitter and receiver to take advantage of mode-conversion phenomena at interfaces between liquid couplant and panel to be probed. Angle of incidence chosen so only shear waves propagate obliquely through panel. Although mode-conversion equations solved to take full advantage of technique somewhat complicated, they are straightforward, and technique implemented easily in practice.

Pereira, J. Michael↗

Review and statistical analysis of the use of ultrasonic velocity for estimating the porosity fraction in polycrystalline materials

A review and statistical analysis of the ultrasonic velocity method for estimating the porosity fraction in polycrystalline materials is presented. Initially, a semiempirical model is developed showing the origin of the linear relationship between ultrasonic velocity and porosity fraction. Then, from a compilation of data produced by many researchers, scatter plots of velocity versus percent porosity data are shown for Al2O3, MgO, porcelain-based ceramics, PZT, SiC, Si3N4, steel, tungsten, UO2,(U0.30Pu0.70)C, and YBa2Cu3O(7-x). Linear regression analysis produces predicted slope, intercept, correlation coefficient, level of significance, and confidence interval statistics for the data. Velocity values predicted from regression analysis of fully-dense materials are in good agreement with those calculated from elastic properties.

Roth, D. J.↗

Guided waves in a multilayered composite and ultrasonic nondestructive evaluation

Analysis of wave propagation in a laminated composite plate with many layers is made difficult by the anisotropy of the laminae, different lay-ups, many layers and defects in the fabricated plate. A good understanding of the wave field in such a plate without defects is a prerequisite for use of ultrasonic techniques to evaluate the various defects that can substantially reduce the strength and service life of this structure. Results of modeling studies of wave propagation and scattering in a multilayered composite plate are presented. The analysis technique combines the finite element discretization through the thickness with wave form representation along the plate in order to calculate the dispersive modes of propagation in the plate. To study scattering of these waves by a matrix crack that grows into delaminations, a hybrid finite element representation of the field near the crack and the modal representation of the scattered exterior field are used. Results are presented showing the dependence of the reflection and transmission coefficients on the size of the crack with delamination which can be used to size the defect using ultrasonic techniques.

Datta, S. K.↗

Ultrasonic time-of-flight monitoring of the position of the liquid/solid interface during the Bridgman growth of germanium

Ultrasound has been used to track the movement of the solid/liquid interface during the vertical Bridgman growth of germanium. Digitally processed data representing the received ultrasonic signal indicated a time lag prior to crystal growth, and showed a growth rate close to the pulling rate of the furnace. No effect of the ultrasonic energy on the growth of the crystal or on the formation of defects was observed. The interface was located to within 0.3 mm in the presence of substantial temperature gradients. An extension of the work presented could lead to a tomographic reconstruction of the interface shape.

Carter, John N.↗

Ultrasonic Inspection Of Thick Sections

Ultrasonics used to inspect large, relatively thick vessels for hidden defects. Report based on experiments in through-the-thickness transmission of ultrasonic waves in both steel and filament-wound composite cases of solid-fuel rocket motors.

Friant, C. L.↗