Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Comparative study of x ray and microwave emissions during solar flares

The work supported by the grant consisted of two projects. The first project involved making detailed case studies of two flares using SMM data in conjunction with ground based observations. The first flare occurred at 1454 UT on June 20, 1989 and involved the eruption of a prominence near the limb. In the study we used data from many wavelength regimes including the radio, H-alpha, hard X-rays, and soft X-rays. We used a full gyrosynchrotron code to model the apparent presence of a 1.4 GHz source early in the flare that was in the form of a large coronal loop. The model results lead us to conclude that the initial acceleration occurs in small, dense loops which also produced the flare's hard X-ray emission. We also found evidence that a source at 1.4 GHz later in the event was due to second harmonic plasma emission. This source was adjacent to a leg of the prominence and comes from a dense column of material in the magnetic structure supporting the prominence. Finally, we investigated a source of microwaves and soft X-rays, occurring approximately 10 min after the hard X-ray peak, and calculate a lower limit for the density of the source. The second flare that was studied occurred at 2156 UT on June 20, 1989 and was observed with the VLA and the Owens Valley Radio Observatory (OVRO) Frequency Agile Array. We have developed a gyrosynchrotron model of the sources at flare peak using a new gyrosynchrotron approximation which is valid at very low harmonics of the gyrofrequency. We found that the accelerated particle densities of the sources decreased much more with radius from the source center than had been supposed in previous work, while the magnetic field varied less. We also used the available data to analyze a highly polarized source which appeared late in the flare. The second project involved compiling a statistical base for the relative timing of the hard X-ray peak, the turbulent and blue-shift velocities inferred from soft X-ray line emissions observed by SMM and the microwave peak as determined from ground-based observations. This timing was then used to aid the testing of newly developed global models for flares that incorporate the global magnetic topology as well as the electron dynamics that are responsible for the hard X-rays and microwaves.

Winglee, Robert M.↗

The Effect of Doppler Frequency Shift, Frequency Offset of the Local Oscillators, and Phase Noise on the Performance of Coherent OFDM Receivers

This paper first shows that the Doppler frequency shift affects the frequencies of the RF carrier, subcarriers, envelope, and symbol timing by the same percentage in an Orthogonal Frequency Division Multiplexing (OFDM) signal or any other modulated signals. Then the SNR degradation of an OFDM system due to Doppler frequency shift, frequency offset of the local oscillators and phase noise is analyzed. Expressions are given and values for 4-, 16-, 64-, and 256-QAM OFDM systems are calculated and plotted. The calculations show that the Doppler shift of the D3 project is about 305 kHz, and the degradation due to it is about 0.01 to 0.04 dB, which is negligible. The degradation due to frequency offset and phase noise of local oscillators will be the main source of degradation. To keep the SNR degradation under 0.1 dB, the relative frequency offset due to local oscillators must be below 0.01 for the 16 QAM-OFDM. This translates to an offset of 1.55 MHz (0.01 x 155 MHz) or a stability of 77.5 ppm (0.01 x 155 MHz/20 GHz) for the DI project. To keep the SNR degradation under 0.1 dB, the relative linewidth (0) due to phase noise of the local oscillators must be below 0.0004 for the 16 QAM-OFDM. This translates to a linewidth of 0.062 MHz (0.0004 x 155 MHz) of the 20 GHz RIF carrier. For a degradation of 1 dB, beta = 0.04, and the linewidth can be relaxed to 6.2 MHz.

Xiong, Fuqin↗

Frequency shifts in a rubidium frequency standard due to coupling to another standard

Highly reliable timing system, such as used on board satellites, may incorporate a hot standby atomic clock besides the active one. RF couplings between them may affect the performance of the active clock. The effect of such couplings between two rubidium atomic clocks was investigated, and it was found that they will add an oscillatory term to the Allan Variance of the active clock, degrading its frequency stability, and that under certain circumstances they may also shift the active clock's operating frequency. These two effects are discussed in detail, and the level of isolation required to render them negligible is established.

Jaduszliwer, Bernardo↗

Development of a Photoacoustic Formaldehyde Monitor

Key indoor air quality pollutant formaldehyde (H2CO) is tracked on International Space Station (ISS) using passive badges returned to the ground periodically for analysis. The process is time-consuming both in preparation and for analysis upon return 6-12 months later. Badges also require precious crew time for deploy, retrieval and stow. As NASA’s focus in space exploration shifts to the Moon and Mars, archival sample return becomes increasingly impractical, so the aim of this project is to develop a highly reliable real-time analyzer for H2CO at low concentrations with data downlinked. Potential sources of H2CO include materials off gassing, use of formalin as a tissue fixative in biological payloads and overheating of acetal polymers. The Spacecraft Maximum Allowable Concentration (SMAC) for H2CO is 100 ppb for exposures of 7 days or longer. ISS concentrations recently run only 10 - 30 ppb but have spiked as high as 60 ppb in the past. Gateway real time monitoring requirements call for a range of 8 - 140 ppb. For this project, a concentration range of 5 - 500 ppb H2CO is targeted. The core tunable diode laser spectroscopy (TDLS) technology was developed by Vista Photonics through the NASA and US Navy Small Business Innovation Research (SBIR) programs. Monitors based on this technology have been demonstrated on ISS, trialed on a nuclear submarine and are in production as Anomaly Gas Analyzers for both ISS and Orion. Initially, direct absorption TDLS was used exclusively in these monitors, however, the H2CO target concentration is much lower, and a longer wavelength required, so a photoacoustic spectroscopy (PAS) technique was adapted, where the laser excitation is detected by a sensitive microphone vs. a conventional photodetector. This paper will discuss the results of NASA-JSC laboratory testing of a prototype PAS based formaldehyde monitor and explore potential adaptations for Gateway missions and beyond.

Paul D Mudgett↗

Development of a Photoacoustic Formaldehyde Monitor

Key indoor air quality pollutant formaldehyde (H 2 CO) is tracked on International Space Station (ISS) using passive badges returned to the ground periodically for analysis. The process is time-consuming both in preparation and for analysis upon return 6-12 months later. Badges also require precious crew time for deploy, retrieval and stow. As NASA’s focus in space exploration shifts to the Moon and Mars, archival sample return becomes increasingly impractical, so the aim of this project is to develop a highly reliable real-time analyzer for H 2 CO at low concentrations with data downlinked. Potential sources of H 2 CO include materials off gassing, use of formalin as a tissue fixative in biological payloads and overheating of acetal polymers. The Spacecraft Maximum Allowable Concentration (SMAC) for H 2 CO in air is 100 ppb for exposures of 7 days or longer. ISS concentrations of H 2 CO are running only 10 - 30 ppb in the recent several years but have spiked as high as 60 ppb. Gateway real time monitoring requirements for H 2 CO call for a range of 8 - 138 ppb. For this project, a concentration range of 5 - 500 ppb H 2 CO is targeted. The core tunable diode laser spectroscopy (TDLS) technology used for this project was developed by Vista Photonics through the NASA and US Navy Small Business Innovation Research (SBIR) programs. Monitors based on TDLS have been demonstrated on ISS, trialed on a nuclear submarine and are being certified as portable Anomaly Gas Analyzers (AGA) for both ISS and Orion. Initially, direct absorption TDLS was used exclusively in these devices. The H 2 CO target concentration, however, is low ppb, and a longer wavelength is required, so a photoacoustic spectroscopy (PAS) technique was adapted, where the laser excitation is detected by a sensitive microphone vs. a conventional photodetector. This paper will discuss the results of NASA-JSC laboratory testing of a prototype PAS based formaldehyde in air monitor and briefly discuss next steps.

Photoacoustic Formaldehyde Monitor↗

Effects of Convective Transport of Solute and Impurities on Defect-Causing Kinetics Instabilities

For in-situ studies of the formation and evolution of step patterns during the growth of protein crystals, we have designed and assembled an experimental setup based on Michelson interferometry with the surface of the growing protein crystal as one of the reflective surfaces. The crystallization part of the device allows optical monitoring of a face of a crystal growing at temperature stable within 0.05 C in a developed solution flow of controlled direction and speed. The reference arm of the interferometer contains a liquid-crystal element that allows controlled shifts of the phase of the interferograms. We employ an image processing algorithm which combines five images with a pi/2 phase difference between each pair of images. The images are transferred to a computer by a camera capable of capturing 6-8 frames per second. The device allows data collection data regarding growth over a relatively large area (approximately .3 sq. mm) in-situ and in real time during growth. The estimated dept resolution of the phase shifting interferometry is about 100 A. The lateral resolution, depending on the zoom ratio, varies between 0.3 and 0.6 micrometers. We have now collected quantitative results on the onset, initial stages and development of instabilities in moving step trains on vicinal crystal surfaces at varying supersaturation, position on the facet, crystal size and temperature with the proteins ferritin, apoferritin and thaumatin. Comparisons with theory, especially with the AFM results on the molecular level processes, see below, allow tests of the rational for the effects of convective flows and, as a particular case, the lack thereof, on step bunching.

Vekilov, Peter G.↗

Virtual Reality as a Medium for Sensorimotor Adaptation Training and Spaceflight Countermeasures

Astronauts experience a profound sensorimotor adaptation during transition to and from the microgravity environment of space. With the upcoming shift to extra‐long duration missions (upwards of 1 year) aboard the International Space Station, the immediate risks to astronauts during these transitory periods become more important than ever to understand and prepare for. Recent advances in virtual reality technology enable everyday adoption of these tools for entertainment and use in training. Embedding an individual in a virtual environment (VE) allows the ability to change the perception of visual flow, elicit automatic motor behavior and produce sensorimotor adaptation, not unlike those required during long duration microgravity exposure. The overall goal of this study is to determine the feasibility of present head mounted display technology (HMD) to produce reliable visual flow information and the expected adaptation associated with virtual environment manipulation to be used in future sensorimotor adaptability countermeasures. To further understand the influence of visual flow on gait adaptation during treadmill walking, a series of discordant visual flow manipulations in a virtual environment are proposed. Six healthy participants (3 male and 3 female) will observe visual flow information via HMD (Oculus Rift DK2) while walking on an instrumented treadmill at their preferred walking speed. Participants will be immersed in a series of VE's resembling infinite hallways with different visual characteristics: an office hallway, a hallway with pillars and the hallway of a fictional spacecraft. Participants will perform three trials of 10 min. each, which include walking on the treadmill while receiving congruent or incongruent visual information via the HMD. In the first trial, participants will experience congruent visual information (baseline) where the hallway is perceived to move at the same rate as their walking speed. The final two trials will be randomized among participants where the hallway is perceived to move at either half (0.5x) or twice (2.0x) their preferred walking speed. Participants will remain on the treadmill between trials and will not be warned of the upcoming change to visual flow to minimize preparatory adjustments. Stride length, step frequency and dual‐support time will be quantified during each trial. We hypothesize that participants will experience a rapid modification in gait performance during periods of adaptive change, expressed as a decrease in step length, an increase in step frequency and an increase in dual‐support time, followed by a period of adaptation where these movement parameters will return to near‐baseline levels. As stride length, step frequency and dual support times return to baseline values, an adaptation time constant will be derived to establish individual time‐to‐adapt (TTA). HMD technology represents a paradigm shift in sensorimotor adaptation training where gait adaptability can be stressed using off‐the‐shelf consumer products and minimal experimental equipment, allowing for greater training flexibility in astronaut and terrestrial applications alike.

Madansingh, S.↗

Intracranial Fluid Redistribution During a Spaceflight Analog

The neural correlates of spaceflight-induced sensorimotor impairments are unknown. Head down-tilt bed rest (HDBR) serves as a microgravity analog because it mimics the headward fluid shift and limb unloading of spaceflight. We investigated focal brain white matter (WM) changes and fluid shifts during 70 days of 6 deg HDBR in 16 subjects who were assessed pre (2x), during (3x), and post-HDBR (2x). Changes over time were compared to those in control subjects (n=12) assessed four times over 90 days. Diffusion MRI was used to assess WM microstructure and fluid shifts. Free-Water Imaging, derived from diffusion MRI, was used to quantify the distribution of intracranial extracellular free water (FW). Additionally, we tested whether WM and FW changes correlated with changes in functional mobility and balance measures. HDBR resulted in FW increases in fronto-temporal regions and decreases in posterior-parietal regions that largely recovered by two weeks post-HDBR. WM microstructure was unaffected by HDBR. FW decreased in the post-central gyrus and precuneus. We previously reported that gray matter increases in these regions were associated with less HDBR-induced balance impairment, suggesting adaptive structural neuroplasticity. Future studies are warranted to determine causality and underlying mechanisms.

Koppelmans, Vincent↗

Selective video blanking technique

Adverse viewing effects caused by faulty photosensitive elements are eliminated. A linear maximal /or nonmaximal/ sequence generator gives a pseudorandom pulse train to selectively blank the display monitor during specified mosaic interrogation times. The outputs minimize the length of the required shift register generator.

Saboe, M. M.↗

Tests of general relativity using pulsars

The arrival times of the pulses from each pulsar are measured by a cesium clock. The observations are all made at a frequency of 2388 MHz (12.5 cm wavelength) on a 26 m dish antenna. The effect of interstellar charged particles is a random one that increases the noise level on the arrival time measurements. The variation in clock rate is shown consisting of two effects: the time dilation effect of special relativity and the red shift effect of general relativity.

Reichley, P. E.↗

Operational modes for a wave injection facility aboard spacelab and a sub-satellite

Various modes of operation are described for an orbiting wave injection facility planned to measure the properties of waves propagating in space plasma. Such a facility would cover a wide frequency range including MF and HF. Phase shift and Doppler shift measurements will yield more accurate measurements of echo time delay and the angle of arrival. Because Spacelab will involve some sub-satellites, some consideration is given to propagation between two vehicles both at HF and VHF.

Dyson, P. L.↗

Optimal use of electrophysiological indicators of muscular effort and fatigue

Electromyograms (EMG) from working muscles convey information on effort and fatigue. Their application, e.g., to assess the demands of vehicle control tasks, is complicated by the cooperative action of sets of muscles, by both intrinsic and imposed filtering, and by numerous other sources of variation. Fourier analyses of these noise like signals offer one approach to interpretation; downward spectral shifts accompany fatigue. Techniques are being sought (in both time and frequency domains) for further condensing the wideband EMG signals, while retaining essential information, into a concise 'state vector' usable in comparing control system designs.

Updike, O. L.↗

Study of fatigue durability of advanced composite materials under conditions of accelerated loading

The effect of temperature on the tension-tension fatigue life of the T300/5208 graphite/epoxy angle-ply laminate system was investigated in an effort to develop an acceptable and reliable method of accelerated loading. Typical S log sub 10 N curves were determined experimentally at 25 C, 75 C, and 115 C. The time-temperature superposition principle was employed to find the shift factors of uniaxial fatigue strength, and a general linear equation of S log sub 10 N for shifting purpose was established. The combined techniques of cyclic creep measurements and optical microscopy upon fatigue failure allow some assessment of the possible physical basis of S log 10 N curve shifting. Before fatigue, the laminates at all test temperatures and stress levels undergo a unique damage mechanism during fatigue loading. It is concluded that an accelerated loading method is feasible.

Shih, H. M.↗

An 8-DPSK TCM modem for MSAT-X

This paper describes the real-time digital implementation of an 8-differentiated phase-shift keying (DPSK) trellis-coded modulation (TCM) modem for operation on an L-band, 5 kHz wide, land mobile satellite (LMS) channel. The modem architecture as well as some of the signal processing techniques employed in the modem to combat the LMS channel impairments are described, and the modem performance over the fading channel is presented.

Jedrey, Thomas C.↗

Advantages of a round-body shuttle

A cylindrical fuselage cross-section SSTOV representing the design generation beyond the current NASA Space Shuttle has been projected capable of reducing the cost of payload delivery to orbit while increasing mission scope. Due to its intrinsically greater wetted-area and structural weight efficiencies, this cylindrical vehicle would carry 40 percent greater payload than the Space Shuttle system despite a 20-percent lower gross liftoff weight. A LOX/hydrocarbon fuel combination would be employed during the early portion of flight, thereupon shifting to LOX/hydrogen. The cylindrical SSTOV would have eight times the volume of the Space Shuttle Orbiter.

Arrington, James P.↗

RF/optical interference design for optical intersatellite links

A design approach for the RF/optical link interface for a data relay satellite is described. The flexibility of forward and return links in future data acquisition satellites in handling varying missions and data rates to 1 Gbit/s is considered. Attention is focused on requirements for the NASA Tracking and Data Acquisition System. System components are described including the return link multiplexer, the return link transmultiplexer, the forward link multiplexer, the forward link demultiplexer, and the frontside/backside switch. Ping-pong buffers, which provide rate buffering for each input data stream, are discussed and justification bits, which handle variations due to Doppler shift and local oscillator variation, are considered. The time-division multiplexed streams consist of a unique synchronization word for frame synchronization, and control words associated with each data burst to identify the presence or absence of a justification bit. Redundant data paths are described for both forward and return data streams.

Garlow, Ronald K.↗