Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time integrator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Differential laser absorption monitoring of the atmosphere

In the airborne detection system of atmospheric constituents and pollutants described, double-ended differential absorption measurement is accomplished by rapidly current tuning the wavelength of a PbSSe diode laser across a single line of the species under consideration. As the laser wavelength sweeps periodically across the absorption line, the laser beam is amplitude modulated and is then synchronously detected. With this technique, a minimum detectable differential transmission of 0.02 percent is obtained for a 1-sec integration time.

Rubin, B.↗

Modeling of radiative heating of base region of Jovian entry probe

The mechanism of radiative heating of the afterbody region of Jovian entry probe is analyzed. A theoretical model is derived to determine the average thermodynamic properties in the expanding region, recirculating region, recompression region, and neck region through application of one-dimensional conservation equations. Flow parameters are obtained from the shadowgraphs of a free-flight test. Radiative transfer is calculated using spectrally detailed computer codes accounting for nonequilibrium. The results show that the most severe heating occurs immediately behind the frustum, and that the recompression and neck regions are the major sources of radiation that heats the base stagnation point. The radiation flux to the base point is slightly stronger with ablation than without, its value being 0.11(43Pb/Ps)squared times that to the front stagnation point, where Pb/Ps is the ratio of base-to-front stagnation point pressures and its value is in the range 0.023-0.066. The time-integrated heat load to the base point is 18(43Pb/Ps)squared kJ/sq cm. Existing experimental data are shown to agree with the theoretical prediction.

Park, C.↗

Simultaneous radio and X-ray observations of the X-ray burst source MXB 1636-53

On June 17, 1977, the X-ray burst source MXB 1636-53 was simultaneously monitored for about 4 hr with the Parkes 64-m radio telescope at a frequency of 14.7 GHz and the SAS 3 X-ray satellite (1.3-12 keV). One X-ray burst was observed; an upper limit (2 sigmas) of 200 mJy is reported for any radio burst coincident with the X-ray event. During the X-ray burst the radio/X-ray time-integrated flux ratio was no more than 375 with a 90 percent confidence. An upper limit (2 sigmas) of 22 mJy was determined for any steady 14.7-GHz source coincident with the X-ray position.

Thomas, R. M.↗

Interplanetary phase scintillation and the search for very low frequency gravitational radiation

Observations of radio-wave phase scintillation are reported which used the Viking spacecraft having an earth-spacecraft link very similar to that which will be used in very low-frequency (VLF) gravitational-wave searches. The phase power-spectrum level varies by seven orders of magnitude as the sun-earth-spacecraft (elongation) angle changes from 1 to 175 deg. It is noteworthy that a broad minimum in the S-band (2.3 GHz) phase fluctuation occurs in the antisolar direction; the corresponding fractional frequency stability (square root Allan variance) is about 3 x 10 to the -14th for 1000-s integration times. A simultaneous two-frequency two-station observation indicates that the contribution to the phase fluctuation from the ionosphere is significant but dominated by the contribution from the interplanetary medium. Nondispersive tropospheric scintillation was not detected (upper limit to fractional frequency stability about 5 x 10 to the -14th). Evidently, even observations in the antisolar direction will require higher radio frequencies, phase scintillation calibration, and correlation techniques in the data processing, for detection of gravitational bursts at the anticipated strain amplitude levels of no more than 10 to the -15th.

Armstrong, J. W.↗

Finite element methodology for transient conduction/forced-convection thermal analysis

Finite element methodology for steady state thermal analysis of convectively cooled structures has been extended for transient analysis. The finite elements are based on representing the fluid passages by fluid bulk-temperature nodes and fluid-solid interface nodes. The formulation of the finite element equations for a typical flow passage is based on the weighted residual method with upwind weighting functions. Computer implementation of the convective finite element methodology using explicit and implicit time integration algorithms is described. Accuracy and efficiency of the methodology is evaluated by comparisons with analytical solutions and finite-difference lumped-parameter analyses. The comparative analyses demonstrate that finite element conduction/conduction methodology may be used to predict transient temperatures with an accuracy equal or superior to the lumped-parameter finite-difference method.

Thornton, E. A.↗

Ionospheric wave spectrum measurements

The local spectrum S(k, omega) of either potential or electron-density fluctuations can be used to determine macroscopic-plasma characteristics such as the local density and temperature, transport coefficients, and drift current. This local spectrum can be determined by measuring the cross-power spectrum. The paper examines the practicality of using the cross-power spectrum analyzer on the Space Shuttle to measure ionospheric parameters. Particular attention is given to investigating the integration time required to measure the cross-power spectral density to a desired accuracy.

Harker, K. J.↗

Bilinear tangent yaw guidance

This paper presents a parametric yaw steering law which has been used to provide closed-loop yaw guidance for the launch of the HEAO (High Energy Astronomy Observatory) satellite mission using the Atlas/Centaur launch vehicle. This bilinear tangent steering law provides near optimal yaw steering for maneuvers requiring insertion into orbits with a specified inclination and node. Bilinear tangent steering is shown to be optimal in both the pitch and yaw planes when a uniform gravitational field is assumed. The conditions under which the general bilinear tangent laws degenerate into linear tangent and constant attitude laws are presented. The flight computer implementation of these laws in a rotating coordinate system using real-time integration of the equations of motion is detailed. Explicit solution of the parametric guidance equations requires the inflight solution of (2x2) two-point boundary value problems in the pitch and yaw planes. Excellent results are obtained even for very large (greater than 50 deg) out-of-plane steering angles.

Brusch, R. G.↗

A dense plasma ultraviolet source

The intense ultraviolet emission from the NASA Hypocycloidal-Pinch (HCP) plasma is investigated. The HCP consists of three disk electrodes whose cross section has a configuration similar to the cross section of a Mather-type plasma focus. Plasma foci were produced in deuterium, helium, xenon, and krypton gases in order to compare their emission characteristics. Time-integrated spectra in the wavelength range from 200 nm to 350 nm and temporal variations of the uv emission were obtained with a uv spectrometer and a photomultiplier system. Modifications to enhance uv emission in the iodine-laser pump band (250 to 290 nm) and preliminary results produced by these modifications are presented. Finally, the advantages of the HCP as a uv over use of conventional xenon lamps with respect to power output limit, spectral range, and lifetime are discussed.

Lee, J. H.↗

The development of a stepped frequency microwave radiometer and its application to remote sensing of the Earth

The design, development, application, and capabilities of a variable frequency microwave radiometer are described. This radiometer demonstrated the versatility, accuracy, and stability required to provide contributions to the geophysical understanding of ocean and ice processes. A closed-loop feedback method was used, whereby noise pulses were added to the received electromagnetic radiation to achieve a null balance in a Dicke switched radiometer. Stability was achieved through the use of a constant temperature enclosure around the low loss microwave front end. The Dicke reference temperature was maintained to an absolute accuracy of 0.1 K using a closed-loop proportional temperature controller. A microprocessor based digital controller operates the radiometer and records the data on computer compatible tapes. This radiometer exhibits an absolute accuracy of better than 0.5 K when the sensitivity is 0.1 K. The sensitivity varies between 0.0125 K and 1.25 K depending upon the bandwidth and integration time selected by the digital controller. Remote sensing experiments were conducted from an aircraft platform and the first radiometeric mapping of an ocean polar front; exploratory experiments to measure the thickness of lake ice; first discrimination between first year and multiyear ice below 10 GHz; and the first known measurements of frequency sensitive characteristics of sea ice.

Harrington, R. F.↗

Sub mm laser local oscillators: Design criteria and results

Diagnostic results are given of the spectral features and the power conversion efficiency of submillimeter (SMM) laser local oscillators. Several criteria are obtained for the design of frequency stable and efficient smm lasers for local oscillator applications. Finally, a design is described and results on the power output and power and frequency stability are given. The mode pattern is very close to a Gaussian profile so that efficient coupling to a quasioptical mixer is possible. The laser provides sufficient output power at a large number of lines to drive the mixer into the low conversion loss regime. Radiometric integration times of several minutes with a spectral resolution of 1 MHz will be possible. With present state-of-the-art Schottky mixers and low noise preamplifiers a radiometric temperature resolution of a few K can be expected over a spectral range from 500to 900 GHz.

Koepf, G. A.↗

Design considerations for optical heterodyne receivers: A review

The current state of knowledge concerning optical heterodyne receivers is reviewed. Following a discussion of noise processes in the heterodyne receiver and the manner in which sensitivity is increased through time integration of the detected signal, an expression for the mean square signal current is derived by mixing a coherent local oscillator with a partially coherent, quasimonochromatic source. Then the manner in which the IF signal calculation can be transferred to any convenient plane in the optical front end of the receiver is demonstrated. Using these techniques, a relatively simple equation is obtained for the coherently detected signal from an extended incoherent source and applied to the heterodyne detection of an extended thermal source and to the backscatter lidar problem where the antenna patterns of both the transmitter beam and heterodyne receiver must be taken into account. Finally, the detection of a coherent source is considered and, in particular, a distant point source such as a star or laser transmitter in a long range heterodyne communications system is discussed.

Degnan, J. J.↗

Scaling characteristics of MPD propulsion

Experiments in which a high-power, quasi-steady MPD thruster is scaled down by a factor of two indicate that the key features of MPD thruster operation are replicated in the smaller version. Voltage-current data over a 24:1 mass flow range show that the ablation onset parameter is constant for each thruster, although the constant is not the same. Time-integrated photographs of the discharge radiance reveal strikingly similar features at scaled values of current and mass flow. The measured terminal properties of the half-scale thruster are similar to the full-scale thruster, but the regime of operation is smaller and generally less efficient, except within a restricted range of arc current and mass flow.

Mead, F. B., Jr.↗

Synthetic aperture radar imaging of moving ocean waves

A theory for the radar imaging of ocean waves is presented under the assumptions that a swell propagates through an ensemble of Bragg scatterers and that the integration time of the synthetic aperture radar (SAR) is small compared to the angular velocity of the swell. Results are presented which show image development and distortions caused by the radial velocities and accelerations of the swell. Neglecting small wave bunching and tilts due to the longer underlying waves, and considering only one-dimensional geometries, the mechanism of wave motions are considered and their efforts on the production of the usual intensity pattern representing the wave image are studied. The analysis shows that in certain situations a processed image can appear which has twice the spatial period of the actual long wave on the ocean, which can confuse the interpretation of ocean wave analysis.

Swift, C. T.↗

Pioneer Venus infrared radiometer - Design, implementation and preliminary results

The paper discusses the Pioneer Venus infrared radiometer design and operation. Its main function is to measure the thermal emission from the atmosphere at seven pressure levels above the Venus clouds, allowing a determination of the vertical temperature structure. In addition to the temperature sounding channels, there are two channels operating in the visible and near infrared to study the structure of the upper clouds, and a far infrared channel sensitive to water vapor in and above the clouds. The instrument can operate in four modes including a calibration sequence; by utilizing the spinning action of the spacecraft and short integration times, a substantial portion of the planet can be mapped within a 90 min data taking period centered about periapsis time. Temperature profiles retrieved during the course of the mission will clarify the dynamical processes in the upper atmosphere.

Martonchik, J. V.↗

Antenna pattern correction procedures for the Scanning Multichannel Microwave Radiometer /SMMR/

Procedures for correcting antenna temperature measurements and retrieving the true brightness temperatures are developed for the Scanning Multichannel Microwave Radiometer (SMMR) flown on the Seasat-A and Nimbus-G satellites. These procedures are necessary to meet the measurement accuracies required for deriving sea surface temperatures and wind speeds. It is shown that sidelobe contributions and polarization cross-coupling are major effects to be accounted for, in addition to some unique features of the SMMR instrument such as integration times and antenna scan characteristics. Methods are presented for data averaging and data reformatting, these are to be used with geophysical parameter retrieval algorithms.

Njoku, E. G.↗

Ionospheric wave measurements with satellite-borne cross-power spectrum analyzers

The paper studies the feasibility of using the cross-power spectrum analyzer on a satellite such as the Space Shuttle to measure the spectrum of potential and charged particle density fluctuations and macroscopic parameters in the ionosphere. The integration time required to make a measurement of a cross-power spectral density to a given accuracy, or its equivalent, the spatial resolution of a measurement to a given accuracy is examined.

Harker, K. J.↗

Integrated infrared detector arrays for low-background astronomy

Existing integrated infrared detector array technology is being evaluated under low-background conditions to determine its applicability in orbiting astronomical applications where extended integration times and photometric accuracy are of interest. Preliminary performance results of a 1 x 20 elements InSb CCD array under simulated astronomical conditions are presented. Using the findings of these tests, improved linear- and area-array technology will be developed for use in NASA programs such as the Shuttle Infrared Telescope Facility. For wavelengths less than 30 microns, extrinsic silicon and intrinsic arrays with CCD readout will be evaluated and improved as required, while multiplexed arrays of Ge:Ga for wavelengths in the range 30 to 120 microns will be developed as fundamental understanding of this material improves. Future efforts will include development of improved drive and readout circuitry, and consideration of alternate multiplexing schemes.

Mccreight, C. R.↗

Accuracy of the determination of mean anomalies and mean geoid undulations from a satellite gravity field mapping mission

Improved knowledge of the Earth's gravity field was obtained from new and improved satellite measurements such as satellite to satellite tracking and gradiometry. This improvement was examined by estimating the accuracy of the determination of mean anomalies and mean undulations in various size blocks based on an assumed mission. In this report the accuracy is considered through a commission error due to measurement noise propagation and a truncation error due to unobservable higher degree terms in the geopotential. To do this the spectrum of the measurement was related to the spectrum of the disturbing potential of the Earth's gravity field. Equations were derived for a low-low (radial or horizontal separation) mission and a gradiometer mission. For a low-low mission of six month's duration, at an altitude of 160 km, with a data noise of plus or minus 1 micrometers sec for a four second integration time, we would expect to determine 1 deg x 1 deg mean anomalies to an accuracy of plus or minus 2.3 mgals and 1 deg x 1 deg mean geoid undulations to plus or minus 4.3 cm. A very fast Fortran program is available to study various mission configurations and block sizes.

Jekeli, C.↗