Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Advanced Manufactured Strain Sensors for Extreme Environments

Experimentation at irradiation test facilities are essential for reducing the innovation time of developmental fuels, fuel cladding, and structural materials employed in next-generation nuclear reactors. However, due to the harsh conditions generated in such reactors and limited instrumentation space, the evaluation of a material’s mechanical properties is often limited to characterization after the materials have been removed from reactor conditions, or post-irradiation examination. These experiments are costly, time-consuming, and fail to capture the critical time-evolving phenomena that occur during the irradiation experiments. Advanced manufactured digital image correlation patterns and strain sensor devices serve as two promising technologies that can be deployed in the confined and challenging orientations of these irradiation experiments while also providing key insight on salient materials phenomena (i.e., mechanical properties).To guide the development of the printed strain sensors prior to their deployment in critical experiments, the adhesion strength between the substrate and printed film interface is measured via tensile testing and a non-contact laser-induced spallation technique. The establishment of these process control steps helped guide the successful fabrication and testing of direct-write strain sensing devices discussed in this work. The fabrication process controls are necessary for enabling the sustained operation of these strain sensing device through experimentation and minimize the potential for premature failure.

36 - MATERIALS SCIENCE↗

Integrated Neutronics Modeling for Inertial Fusion Energy Systems: Development and Application to LD-FIRST

Lawrence Livermore National Laboratory (LLNL) is proposing a new Laser Driven Fusion Integration Research and Science Test Facility (LD-FIRST) with the goal of providing an experimental testbed for future Inertial Fusion Energy (IFE) systems. However, IFE systems require detailed and accurate multiphysics modeling to quantify material damage, thermal loading, and tritium breeding within complex chamber environments. This article presents the first step in an integrated multiphysics framework that couples meshed CAD-based geometry within Monte Carlo neutronic simulations to enable high-fidelity analysis of IFE chamber concepts, with future coupling to external codes. The neutronics workflow utilizes OpenMC and its third-party capability to use CAD-based geometries through DAGMC and tally on unstructured meshes with Libmesh to evaluate neutron transport behavior, geometric fidelity, and material performance under reactor-relevant conditions. The use of tailored tallies on unstructured meshes in this framework allows direct transfer without interpolating to CFD simulation tools. Two IFE chambers were evaluated, both conceived by LLNL: HYLIFE-II and Laser IFE (LIFE). This work produced high-fidelity conformal surface and volumetric meshes of the HYLIFE-II and LIFE chambers with mapped spatial insight into material damage, thermal loading, and tritium breeding. The HYLIFE-II model was built utilizing available resources and used as a test case to verify that the neutronics framework can handle complex geometries. The LIFE chamber CAD was provided by LLNL and was the main focus of this work. This work analyzes multiple ternary alloy breeding materials for the LIFE chamber, across different 6 Li enrichments to produce data relevant to the LD-FIRST project. This work also investigates the level of model fidelity for the LIFE chamber, and results show that inclusion of detailed first wall and coolant structures increased the predicted tritium breeding ratio (TBR) by ~30%, highlighting the sensitivity of tritium breeding and the need for a high-fidelity simulation framework for IFE chambers. These developments provide a scalable toolset for the design and optimization of next-generation IFE chambers, forming a solid foundation for future coupled multiphysics analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solid oxide electrolysis cell and stack testing best practices

Solid oxide electrolyzer (SOE) technology is an emerging method for hydrogen production, noted for its superior electrical efficiency. Despite the significant progress made in recent years, the broad development of SOE technology is often constrained by the necessary and extensive "skill of the craft" required to successfully test simple single cell test articles. This may be linked to the dearth of practical and pragmatic guidance within the literature for safe, reliable, and performant test equipment and test procedures. Researchers at the Idaho National Laboratory (INL) have been actively testing SOEs ranging from button cells to stacks up to 500 kW, in collaboration with industry and other national laboratories. Based on operational experience, INL has developed system design procedures that ensure safe and reliable operation of SOE systems with the level of support required for each test. This paper presents key aspects of SOE stack and system testing, including safe design procedures, balance of plant components design, and specific implementations at INL. Practical design details of reactants, heat, and power management are presented along with lessons learned from the SOE test facility operations at INL.

08 HYDROGEN↗

Magnetic Measurements of $\mathrm{HL-LHC AUP}$ Cryo-Assemblies at Fermilab

LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test facility. The ~10 m long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis location, and for variations in axis position and local field profiles. A multi-probe, PCB-based rotating coil and a Single Stretched Wire system are employed for these measurements. To accurately determine rotating coil location and angles within the cold mass, a laser tracker is utilized to record multiple targets at one end of the probe. Here this paper describes the measurements, probes/equipment, and techniques used to perform the necessary characterization of the cold mass.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated Vehicle Feasibility Study

This study collected automated vehicle (AV) performance data on public roadways in Athens, Ohio. The route for the study contained a combination of roads with different functional classifications, conditions, annual average daily traffic, and ownership responsibilities for maintenance and repair. Preparation for the public road deployment was done in a controlled environment at Transportation Research Center’s SMARTCenter, a dedicated AV test facility in East Liberty, Ohio. Researchers analyzed data and extracted insights relevant for both AV developers and infrastructure owners and operators. The study found that rural environments offer a unique set of roadway features such as hills and curves, which can challenge the driving behavior of an AV. Rural regions can also contain a large number of low-traffic gravel roads that lack pavement markings, which appear to be a crucial infrastructure element for operation of current generation AVs. Similarly, the presence of well-maintained lane lines along curves can influence the AV’s roadway departure tendencies. The study found that curvature-related behavior of an AV is also influenced by driving speed on the roadway segment. Such findings were consistent regardless of the time of day along the route or season of data collection. However, commentary about AV performance in active adverse weather cannot be made, as this is still an area of active research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

UHT-CAMANCHE: Ultra-High Temperature Ceramic Additively Manufactured Compact Heat Exchangers

The conceptual basis for this project is the convergence of advanced ultra-high temperature ceramic materials and additive manufacturing technologies to produce compact ceramic heat exchangers with complex internal flow path geometries. Task areas were broadly divided into materials and manufacturing development, heat exchanger design, component testing, and techno-economic analysis. Technical challenges included the design and commissioning of new test facilities, improving feature resolution and deposition rate of ceramic additive manufacturing techniques, establishing process-structure-property relationships in additively manufactured ultra-high temperature ceramics, and assessing high temperature materials compatibility in CO 2 environments. The primary candidate material evaluated in this work is a composite comprising zirconium diboride (ZrB2) with 30 vol. % silicon carbide (SiC) which was selected based on its desirable combination of high temperature mechanical properties, high thermal and electrical conductivities, and oxidation resistance. High solids loaded ZrB2-SiC pastes suitable for extrusion-based additive manufacturing were developed for the first time as part of this work. Materials compatibility studies indicate this material oxidizes in CO 2 to form a protective borosilicate scale which transforms to pure silica above 1000°C. Parts made by additive manufacturing displayed enlarged grain sizes produced by pressureless sintering as compared to hot-press sintering. Increases in microstructural coarseness have outsized effect on oxidation performance up to 1400°C due to incomplete oxidation of coarse large diameter SiC particles resulting in lower amounts of silica that apparently inhibit protective scale formation. Additive manufacturing as a forming technique did not appear to significantly affect thermal conductivity, hardness, or elastic modulus, though flexural strength was reduced by half or more as compared to traditionally hot-pressed materials. This effect was attributed to the presence of strength-limiting flaws (ca. 40 microns in size) originating from extrudate inhomogeneities that could potentially be eliminated with further process improvements. Attempts to attain economies of scale for production of multi-kilowatt scale heat exchangers by ceramic additive manufacturing proved difficult. Lack of automation and a modest extrusion rate while retaining fine feature resolution made the overall process labor intensive and limited experimental throughput. A number of full-scale components were taken through post-process heat treatments including drying, binder burnout, and sintering; however, none survived without significant flaws or cracks. Therefore, no operational data from a newly installed heat exchanger test loop were able to be obtained during the performance period. Continued research and development is recommended to improve economic feasibility of ceramic additive manufacturing by standardizing the use of advanced sensors, artificial intelligence, and automation tools to reduce associated labor costs and accelerate production rates. The materials and manufacturing techniques demonstrated in this work are likely to find applications in defense and energy applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Safe passage of American Eels through a novel hydropower turbine

Abstract Objective Study the effects of downstream passage through a novel turbine designed for fish safety, the Restoration Hydro Turbine (RHT), on American Eels Anguilla rostrata in a recirculating turbine test facility. Methods A 55‐cm‐diameter RHT was operated under 10 m of hydraulic head and 667 revolutions/min. In total, 131 eels were passed through the turbine and 43 eels were used as experimental controls (length = 33.9–65.5 cm). High‐speed video of passage through the runner region was captured for 89% of turbine‐passed eels, and injury and behavioral effects were recorded immediately before and after passage, as well as after a 48‐h holding period. A subset of 37 eels was additionally examined with X‐ray imaging for internal injuries. Result The 48‐h survival rate for both treatment and control groups was 100%, with no major internal or external injuries present after the holding period. Conclusion This is a substantial improvement over eel survival rates through conventional Kaplan and Francis turbines, which may range from 40% to 95%, and suggests that hydropower turbines designed for safe downstream fish passage could be implemented without major impacts to eels.

59 BASIC BIOLOGICAL SCIENCES↗

A digital twin platform for building performance monitoring and optimization: Performance simulation and case studies

Advancements in sensor technology, data analytics, affordable compute, and communication infrastructure have paved the way for Digital Twin technology in optimizing building operations and controls. This study presents the development of an open and interoperable web-based Digital Twin platform for integrating diverse data streams and facilitating effective user interactions. The platform utilizes modern technologies for the web framework and time-series data management, ensuring scalability and responsiveness. The backend supports seamless integration of diverse data sources and emulators, incorporating data from building sensors and meters, external weather Application Programming Interfaces, and advanced EnergyPlus simulation models of the building and its energy systems including the Distributed Energy Resources that are formulated in Functional Mockup Units. A simulation case study was conducted with FlexLab, a test facility on Lawrence Berkeley National Laboratory campus. The case study includes normal operations, Distributed Energy Resource integration, and power outage scenarios, to illustrate the Digital Twin’s ability to provide critical insights into energy performance and thermal resilience. The results demonstrated the platform’s potential as a decision-support tool for optimizing building energy performance and enhancing resilience against extreme weather events. Future work will focus on deploying the Digital Twin platform to a real building for field validation, extending its capabilities to cover more scenarios such as bidirectional Electric Vehicle interactions, and enhancing user engagement.

EnergyPlus↗

Impact of Grain Size on Performance Degradation of TREAT LEU

We argue that radiation damage induced degradation of thermal conductivity does not set a lower limit on fuel grain sizes for the low enriched uranium fuel design of the Transient Reactor Test Facility (TREAT). Earlier work reports that smaller grains cause a larger degradation of thermal conductivity than larger grains constraining the smallest feasible size of fuel grains. This work assesses TREAT’s transient performance in the presence of radiation damage. The difference between the two studies is in treating damaged and fresh graphite as serial (this work) or parallel (previous) heat resistors. We use a multiphysics model of TREAT fuel grains to compute the reduction in transient capability measured by the total deposited energy as a function of irradiation dose. We find that radiation damage has a negligible effect on energy deposition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of tritium effluent from Prototype Generation IV Sodium-cooled Fast Reactor

We report a tritium transport model for a pool-type sodium cooled fast reactor was developed for estimation of tritium effluents from the Prototype Generation IV Sodium-cooled Fast Reactor (PGSFR). For this purpose, the transport model developed for Experimental Breeder Reactor II and Fast Flux Test Facility was updated and validated. The tritium production rate from ternary fission and activations in PGSFR were calculated by the Argonne Reactor Computation (ARC) code suite for fast reactor analysis, and due to the potential uncertainties in source terms and variations of cold trap performance and material permeability during reactor operation, the tritium distributions and tritium effluents were estimated for several bounding cases. The upper bounding gaseous and liquid tritium release rates from PGSFR are similar to ~440.7 Ci/year and 14.7 Ci/year, respectively. The gaseous tritium effluent is about few orders of magnitude smaller than the regulatory constraint of the tritium concentration in the air. The peak tritium concentration in the steam-generator feedwater is similar to ~1.1x10 -3 mu Ci/g, which is required to be diluted prior to releasing as tritiated water. The accumulated tritium in the cold trap after five cycle operations is ~ 52,000 Ci. Because of significant conservatism in these upper bounding estimations, it is expected that the tritium effluent at the nominal case with plausible source terms would be about 2 orders of magnitude smaller than that of the upper bounding case.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A transfer learning approach to energy-efficient control of small and medium-sized commercial buildings

Model-free reinforcement learning (RL) provides a data-driven and adaptive approach to optimize building energy use while satisfying occupant comfort. This powerful tool does not need any prior knowledge about the environment and system it is optimizing and can adapt its policy based on the changes in captures. Like any other data-driven tool, it faces high training costs due to the extensive agent-environment interactions required to capture long-term building dynamics and user comfort. Transfer learning, particularly policy distillation, offers a promising way to accelerate training by leveraging pretrained RL agents in different building and system types. Here, this study investigates online student distillation, in which the student model updates its neural network weights using outputs from teacher models. The work introduces a student distillation strategy designed for efficient knowledge transfer, along with a teacher selection method that ensures high-quality guidance. The approach is validated using a highly calibrated whole building energy model for a small/medium commercial building test facility. Results show substantial reductions in training time and data requirements while surpassing the performance of ASHRAE Guideline 36, an advanced rule-based control strategy. The distilled RL model required 45% less data and achieved 20% higher cumulative rewards than a state-of-the-art RL model, with faster convergence and lower energy consumption. These outcomes demonstrate that effective transfer learning enables a scalable and data-efficient energy management solution for commercial buildings.

ASHRAE guideline 36↗

Demonstration of a multi-channel fluidized bed particle–supercritical carbon dioxide heat exchanger for concentrating solar applications

High-temperature thermal energy storage in oxide particles at temperatures above 600°C can couple concentrated solar energy with high-efficiency thermal power cycles to provide dispatchable solar-driven electricity. Challenges remain in developing cost-effective primary heat exchangers, which require expensive alloys, to extract the high-temperature thermal energy from the particles to power cycle fluids, such as supercritical CO 2 (sCO 2 ) in recuperated Brayton cycles. To explore one pathway for cost-effective, high-temperature particle heat exchangers, the current study demonstrates a shell-and-plate, particle–sCO 2 heat exchanger with narrow- channel fluidized beds coupled with micro-channel sCO 2 flows in the heat exchanger walls. This study evaluates the feasibility of multiple parallel, narrow-channel fluidized beds in shell-and-plate particle–sCO 2 HXs, to achieve high bed-wall heat fluxes at elevated temperatures. A reduced-order model simulates the narrow- channel, fluidized-bed particle–sCO 2 heat exchanger to design the fluidized bed geometry, in terms of depth, height, and number of channels,for a nominal 40-kWth heat exchanger at particle and sCO 2 inlet temperatures up to 600 °C and 400 °C respectively. The resulting shell-and-plate heat exchanger design operates with bubbling fluidization of the downward-flowing oxide particles to enhance bed-wall heat transfer. The heat exchanger core is fabricated with etched sCO 2 micro-channels in thin wall plates that are diffusion bonded to spacer frames to form the shell-and-plate structure with 12 parallel, fluidized bed channels, 10.4 mm deep. The heat exchanger is tested at the National Solar Thermal Test Facility at Sandia National Laboratories with CARBOBEAD HSP particles at design particle flow rates of 0.20 kg s –1 and inlet temperatures up to 525 °C. Results show that fluidization across multiple parallel channel beds can maintain uniform particle inventory with a common freeboard zone above the heat exchanger core. Bubbling fluidization improves particle–wall heat transfer coefficients but also increases axial dispersion of particle thermal energy, which lowers the log- mean temperature difference such that total heat transfer remains relatively constant to within ±10% over a broad range of fluidization gas velocities. The axial dispersion required particle and sCO 2 flow rates to be increased by 25% over model-designed conditions to achieve the targeted 40 kWth, which indicates the importance of incorporating axial dispersion into heat exchanger design models and of deploying bed structures to suppress it. Furthermore, this study demonstrates the feasibility and preferred fluidizing gas conditions for particle heat exchangers for releasing high-temperature thermal energy storage systems.

14 SOLAR ENERGY↗

Physics-informed hybrid modeling methodology for building infiltration

Infiltration is responsible for one-third to one-half of the space conditioning load of a typical residential home, but the modeling of infiltration for building energy modeling is either represented by over-simplified equations or dependent on over-generalized rules of thumb. Here, this paper develops a physics-informed data-driven methodology for modeling infiltration using building-specific empirical measurements. The developed hybrid methodology combines machine-learning categorization and grey-box sub-modeling to improve the accuracy and generalization of commonly used grey-box infiltration models. The developed methodology excels at predicting infiltration by improving the ability to predict infiltration under unseen environmental conditions using machine learning algorithms with physical significance. In a case study conducted using the iUnit, a modular studio apartment experimental test facility located at the National Renewable Energy Laboratory, we use empirical airtightness measurements to fit an infiltration model using the developed methodology. We find that the developed methodology can improve the overall model accuracy by 43% and improve extrapolation by 38%, compared with the model based on the common grey-box infiltration equation. We also notice that the selected features can improve the performance of a pure machine-learning model, indicating that our methodology identifies the features with the most physical significance to infiltration modeling.

97 MATHEMATICS AND COMPUTING↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

Sensor cost-effectiveness analysis for data-driven fault detection and diagnostics in commercial buildings

Data-driven building fault detection and diagnostics (FDD) is heavily dependent on sensors. However, common sensors from Building Automation Systems are not optimized to maximize accuracy in FDD. Installing additional sensors that provide more detailed building system information is key to maximizing the performance of FDD solutions. Here in this paper, we present a sensor cost analysis workflow to quantify the economic implications of installing new sensors for FDD using the concept of sensor threshold marginal cost (STMC). STMC does not represent actual sensor cost. Rather, it represents a target cost based on the economic benefit that would be realized through improved FDD performance and one or more specified economic criteria. We calculate STMCs for multiple possible fault types and use fault prevalence information to aggregate STMCs into a single dollar value to determine the cost-effectiveness of a potential sensor investment. We conducted a case study using Oak Ridge National Laboratory's Flexible Research Platform (FRP) test facility as a reference. The case study demonstrates the feasibility of the analysis and highlights the key cost considerations in sensor selection for FDD. The results also indicate that identifying and installing the few key sensor(s) is critical to cost-effectively improve FDD performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nuclear response of additive manufactured GRCop-84 copper for use in Lower hybrid launchers in a fusion environment

Recent advances in selective laser melting (SLM) 3D printing technology allow additive manufacture of lower hybrid current drive (LHCD) RF launchers from a new material, Glenn Research Copper 84 (GRCop-84), a Cr 2 Nb (8 at. % Cr, 4 at. % Nb) precipitation hardened alloy, in configurations unachievable with conventional machining. Tensile strength and thermal conductivity are compared to other competing high conductivity copper alloys for fusion use. Swelling and conductivity at 100 DPA when exposed to the Hanford Fast Flux Test Facility neutron spectrum is predicted in the 1–2 % and 65-70% IACS range, respectively, by comparison to copper alloys with similar precipitate and grain size. Finally, self-similar ion irradiation of a GRCop-84 target at 430 °C to 20 DPA resulted in no noticeable void formation in FIB cross sections or TEM lamella.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using optical fibers to examine thermal mixing of liquid sodium in a pool-type geometry

Sodium fast reactors (SFR) are poised to be a leading candidate for the next generation of commercial nuclear reactor deployment. Companies are commissioning designs for SFR increasing the need for experimental and computational analysis to improve the economics and safety of these reactors. Analysis of SFR behavior during reactor transients directly informs the understanding of reactor safety. Particularly, investigating the thermal transients associated with the reactor loss of flow transient allows for informed design decisions to be made regarding reactor safety. During loss of flow transients the flow rate of the coolant is significantly reduced, but not necessarily stopped. The reduction in flow rate results in coolant temperatures exiting the reactor core that can be drastically different than the coolant in upper pool. When these different temperature fluids interact, thermally stratified layers can form causing cyclic thermal fatigue on the reactor vessel potentially leading to pre-material failure. Past experimental studies have lacked high resolution temperature measurements. This research focuses on demonstrating the reliability of novel techniques for acquiring high resolution temperature measurements in a scaled liquid sodium facility. Tests are conducted that simulate postulated loss of flow transients and provide unprecedented spatial temperature distribution measurements.

42 ENGINEERING↗