Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

PowerChoice Residential Customer Response to TOU Rates

Research Into Action, Inc. and the Sacramento Municipal Utility District (SMUD) worked together to conduct research on the behaviors and energy use patterns of SMUD residential customers who voluntarily signed on to a Time-of-Use rate pilot launched under the PowerChoice label. The project was designed to consider the how and why of residential customers ability and willingness to engage in demand reduction behaviors, and to link social and behavioral factors to observed changes in demand. The research drew on a combination of load interval data and three successive surveys of participating households. Two experimental treatments were applied to test the effects of increased information on households ability to respond to the Time-of-Use rates. Survey results indicated that participants understood the purpose of the Time-of-Use rate and undertook substantial appropriate actions to shift load and conserve. Statistical tests revealed minor initial price effects and more marked, but still modest, adjustments to seasonal rate changes. Tests of the two information interventions indicated that neither made much difference to consumption patterns. Despite the lackluster statistical evidence for load shifting, the analysis points to key issues for critical analysis and development of residential Time-of-Use rates, especially pertinent as California sets the stage for demand response in more California residences.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of an in vitro test battery for assessing chemical effects on bovine germ cells under the ReProTect umbrella

Current European legislation for the registration and authorisation of chemicals (REACH) will require a dramatic increase in the use of animals for reproductive toxicity testing. Since one objective of REACH is to use vertebrates only as last resort, the development and validation of alternative methods is urgently needed. For this purpose ReProTect, an integrated research project funded by the European Union, joining together 33 partners with complementary expertise in reproductive toxicology, was designed. The study presented here describes a battery of two tests developed within ReProTect. The objective of these tests is the detection of chemical effects during the processes of oocyte maturation and fertilisation in a bovine model. The corresponding toxicological endpoints are the reaching of metaphase II and the formation of the pronuclei respectively. Fifteen chemicals have been tested (Benzo[a]pyrene, Busulfan, Butylparaben, Cadmium Chloride, Carbendazim, Cycloheximide, Diethylstilbestrol, Genistein, Ionomycin, Ketoconazole, Lindane, Methylacetoacetate, Mifepristone, Nocodazole and DMSO as solvent) demonstrating high intra-laboratory reproducibility of the tests. Furthermore, the responses obtained in both tests, for several substances, had a good correlation with the available in vivo and in vitro data. These tests therefore, could predictably become part of an integrated testing strategy that combines the bovine models with additional in vitro tests, in order to predict chemical hazards on mammalian fertility.

60 APPLIED LIFE SCIENCES↗

Resilient Transmission Hardening Planning in a High Renewable Penetration Erra

Hardening components in transmission systems is a practice to improve system resilience against possible disturbances caused by natural disasters. In a power system with a very high penetration of renewable energy, the system hardening will be further complicated by the uncertainty and variability of renewable energy. In this paper, we study the transmission line hardening planing problem in the context of probabilistic power flows injected by the high penetration of renewable energy. We assume that the probabilistic information of renewable energy is incomplete and ambiguous and propose a data-driven approach to approximate the renewable uncertainty sets. We then extend the N - 1 security criteria to multiple simultaneous contingencies and seek to prepare a hardening plan for the worst-case scenarios. A two-stage data-driven stochastic model is formulated by considering the joint worst-case wind output distribution and transmission line contingencies. Then, we apply the Column-and-Constraints generation method to solve the proposed model. To test the effectiveness of the proposed approach, we conduct experiments on 24-bus and 118-bus test systems. We numerically show that the data-driven approach can effectively address the uncertainty ambiguity and the proposed approach can produce effective hardening plans that improve the system resilience.

Column-and-Constraint generation↗

Tensile testing and fracture mechanism analysis of polyvinyl alcohol nanofibrous webs

Abstract A tensile properties testing study was conducted to understand the influence of thickness, cross‐head speed (speed of testing), gauge length (GL; specimen test length), and sample shape on important tensile properties of polyvinyl alcohol (PVA) nanofiber webs. The effects of each testing parameter on load at break, extension at break, Young's modulus, and tensile stress–strain curve of PVA nanofiber webs are analyzed. The Welch two sample t ‐tests show the significant difference among tested data. Using interaction plots, two‐way analysis of variance, and margin mean plots, the interaction effects among testing parameters have been analyzed. Of all the factors, cross‐head speed, the interaction among GL, and sample thickness (GL: Thickness) and the interaction among GL, testing speed and sample thickness (GL: Speed: Thickness) have significant influence on the tensile properties of PVA nanofiber webs. Moreover, the hypothesized model of mechanism of tensile strain–stress curve of PVA nanofiber webs has been proposed. Based on the model, the tensile strain–stress curve can be split into three stages: linear elastic, partial break up, and complete breakage. This study will provide a better understanding of tensile testing parameters' effects and their interaction effects on the tensile properties of nanowebs.

Lou, Lihua↗

Effect of GPS Manipulation to Traditional and Next Generation Relay Protection

This project’s objective is to test the effect of GPS timing variations on relay protection algorithms to determine vulnerabilities and the associated hazards to the electric grid. This will focus on differential protection which utilizes peer to peer communication between substations to determine if the current is not equivalent. This requires the use of GPS to sync the two substations and can be vulnerable to GPS manipulation. However, the effects of GPS manipulation are not a commonly known risk. Therefore, this LDRD will address the risks of GPS manipulation for such a widely implemented technology. For differential protection a GPS resilient architecture was implemented and tested for differential protective relays through a direct serial fiber connection between the two relays. This allows for one relay to be the master and provide synchronization outside of timestamp for differential protection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving Robustness of Spectrogram Classifiers with Neural Stochastic Differential Equations

Signal analysis and classification is fraught with high levels of noise and perturbation. Computer-vision-based deep learning models applied to spectrograms have proven useful in the field of signal classification and detection; however, these methods aren't designed to handle the low signal-to-noise ratios inherent within non-vision signal processing tasks. While they are powerful, they are currently not the method of choice in the inherently noisy and dynamic critical infrastructure domain, such as smart-grid sensing, anomaly detection, and non-intrusive load monitoring. Currently, these models can be brittle, which makes them susceptible to noisy input. This also means they have sub-optimal stability of explanation outputs. Experts and technicians using these models to make decisions in real world scenarios need assurance that a model is performing as it is supposed to. The classification or prediction outputs it generates should be sound and grounded, not likely to change in the presence of shifting noise landscapes. In this work, we explore the idea of Neural Stochastic Differential Equations (NSDE's) to improve the robustness of models trained to classify time series data and the effect of NSDE's on the explainability of outputs. We then test the effectiveness of these approaches by applying them to a non-intrusive load monitoring (NILM) dataset that consists of simulated harmonic signals injected into a real building.

Brogan, Joel↗

Open Heavy Flavor Production at Forward Angles in PHENIX

Measurement of the production of heavy quarks in heavy ion collisions can be used to probe the early stages of the created medium, study hot and cold nuclear matter effects, and test theoretical predictions concerning quark energy loss and initial-state effects. This is a current area of active research in the field and it is important to extend such measurements to the forward region. PHENIX can measure the production of open heavy flavor at forward angles with subsequent semi-leptonic decay of heavy flavor mesons into muons. We report the nuclear modification factor for the production of muon from heavy flavor decay in Cu+Cu collisions at s_NN = 200 GeV for three centrality intervals and compare to theoretical predictions concerning the suppression of heavy quark production which incorporate heavy quark energy loss and in-medium heavy meson disassociation. Additionally, we report the charm production cross section for p+p collisions at s = 200 GeV and compare results to Fixed Order plus Next-to-Leading Log predictions Research sponsored by the Office of Nuclear Physics, U.S. Department of Energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fuel hardware considerations for BWR PCI mitigation

Pellet-clad interaction (PCI) remains a potential cause of fuel failures and is a major consideration in the design of new BWR fuel assemblies. The design and material properties of both the pellet and the cladding have been investigated and optimized to mitigate the impact of PCI. The creep behavior of standard and ADOPT (Advanced Doped Pellet Technology) fuel pellets has been measured across a wide range of temperatures. Dopants have been found to increase the high temperature creep properties of the fuel and can explain the improved PCI resistance of ∼5 kW/m in ramp tests. Other effects, such as chemical trapping of fission products and modified crack patterns cannot be ruled out, but these are at an earlier stage of investigation. It is shown that the enhanced creep effect occurs at the high centerline fuel temperatures during a ramp test, but is not present during the much lower temperatures of commercial fuel operation. Thus low temperature PCI benefits in routine commercial operation are not expected. The development of cladding materials with liner provided a great improvement for PCI mitigation in BWRs. With the softer Westinghouse liner, stepwise ramp tests have shown a benefit of ca 15-20 kW/m. Differences between stepwise and single step ramp tests are discussed. Notably the benefit of the liner remains under all types of fuel operation and temperatures. It is also thought to provide significant benefit in the case of fuel relocation or pellet defects such as missing pellet chips. The results of post irradiation examination (PIE) of a commercial fuel rod that experienced fuel fragment relocation are presented in the paper. To provide the maximum PCI benefit in the next generation BWR fuel design, TRITON11, the proven benefits of both the liner and ADOPT pellets will be included. To reduce the hydrogen pickup, below that of Zircaloy-2, the outer cladding component will be made from HiFi. TRITON11, ADOPT and HiFi are registered trademarks of Westinghouse Electric Company LLC in the United States. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Prostaglandin potentiates 5-HT responses in stomach and ileum innervating visceral afferent sensory neurons

Highlights: • Prostaglandin E2 (PGE{sub 2}) effect was tested on visceral afferent neurons. • PGE{sub 2} did not evoke response but potentiated serotonin (5-HT) currents up to 167%. • PGE{sub 2}-induced potentiation was blocked by E-prostanoid type 4 receptors antagonist. • PGE{sub 2} effect on 5-HT response was also blocked by protein kinase A inhibitor KT5720. • Thus, PGE{sub 2} modulate visceral afferent neurons via synergistic signaling with 5-HT. - Abstract: Gastrointestinal disorder is a common symptom induced by diverse pathophysiological conditions that include food tolerance, chemotherapy, and irradiation for therapy. Prostaglandin E{sub 2} (PGE{sub 2}) level increase was often reported during gastrointestinal disorder and prostaglandin synthetase inhibitors has been used for ameliorate the symptoms. Exogenous administration of PGE{sub 2} induces gastrointestinal disorder, however, the mechanism of action is not known. Therefore, we tested PGE{sub 2} effect on visceral afferent sensory neurons of the rat. Interestingly, PGE{sub 2} itself did not evoked any response but enhanced serotonin (5-HT)-evoked currents up to 167% of the control level. The augmented 5-HT responses were completely inhibited by a 5-HT type 3 receptor antagonist, ondansetron. The PGE{sub 2}-induced potentiation were blocked by a selective E-prostanoid type4 (EP{sub 4}) receptors antagonist, L-161,982, but type1 and 2 receptor antagonist AH6809 has no effect. A membrane permeable protein kinase A (PKA) inhibitor, KT5720 also inhibited PGE{sub 2} effects. PGE{sub 2} induced 5-HT current augmentation was observed on 15% and 21% of the stomach and ileum projecting neurons, respectively. Current results suggest a synergistic signaling in visceral afferent neurons underlying gastrointestinal disorder involving PGE{sub 2} potentiation of 5-HT currents. Our findings may open a possibility for screen a new type drugs with lower side effects than currently using steroidal prostaglandin synthetase inhibitors by selectively targeting EP{sub 4} receptor/PKA pathway without interrupt prostaglandin synthesis.

60 APPLIED LIFE SCIENCES↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effectiveness of Rain Cleaning on Artificially Soiled PV Modules With and Without Anti-Soiling Coatings

A simple, inexpensive methodology for testing the effectiveness of rain cleaning on artificially soiled single-cell and multi-cell photovoltaic (PV) modules having anti-soiling coatings has been developed. Using an indoor soil deposition chamber and methodology as described in our previously published work, multiple layers of soil were deposited on to the glass surface of single-cell PV modules subjected to controlled temperature and humidity cycles. Three single-cell monocrystalline PV modules are reported in this study, two of which had different anti-soiling (AS) coatings applied to the surface and the third did not have any AS coating. The set-up and operation of a rain-simulator is described as well as the rain cleaning parameters the PV test modules were exposed to. The purpose of this work is to determine the effectiveness of anti-soiling coatings and cleaning techniques, so vendor claims can be quantitatively validated using an appropriately controlled soil deposition chamber and a rain simulating spray nozzle.

14 SOLAR ENERGY↗

Comment on “Test of the Stark-effect theory using photoionization microscopy”

An article by Zhao et al. [Phys. Rev. A 86, 053413 (2012)] tests the local frame transformation (LFT) theory by comparing it with benchmark coupled-channel calculations. The system under consideration is an alkali-metal atom that is two-photon ionized in the presence of a static external electric field. Zhao et al. state that the differential cross sections computed in the LFT theory disagree with their supposedly more accurate coupled-channel calculations. They went on to diagnose the discrepancy and claimed that it originates in an inaccurate correspondence between the irregular functions in spherical and parabolic-cylindrical coordinates, a correspondence that lies at the heart of LFT theory. We have repeated the same tests and find that our calculations rule out the discrepancies that were claimed in Zhao et al. [Phys. Rev. A 86, 053413 (2012)] to exist between the LFT approximation and the exact calculations. Lastly, this Comment thus helps to clarify the accuracy of the Harmin-Fano theory and demonstrates that it is in fact remarkably accurate not only for the total photoionization cross section in the Stark effect, but also for the differential cross section in photoionization microscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fluorinated Electrolytes for 5-V Li-Ion Chemistry: Probing Voltage Stability of Electrolytes with Electrochemical Floating Test

A series of electrolyte formulations containing fluorinated cyclic carbonates and fluorinated linear carbonates with LiPF6 has been evaluated as electrolyte solvents for high-voltage Li-ion batteries. The anodic stability of the new electrolytes on fully charged spinel LiNi0.5Mn1.5O4 (LNMO) cathode was examined by electrochemical floating tests. The effects of fluorine substitution on the cyclic and linear carbonate, ratio of cyclic vs. linear carbonate, and LiPF6 concentration on the electrolyte oxidation stability were investigated. Based on this study, the floating test proved to be an effective tool for identification of stable electrolyte materials.

5-V LiNi0.5Mn1.5O4 cathode↗

Data Collection Methods for Validation of Advanced Multi-Resolution Fast Reactor Simulations

In pool-type Sodium Fast Reactors (SFR) the regions most susceptible to thermal striping are the upper instrumentation structure (UIS) and the intermediate heat exchanger (IHX). This project experimentally and computationally (CFD) investigated the thermal mixing in the region exiting the reactor core to the UIS. The thermal mixing phenomenon was simulated using two vertical jets at different velocities and temperatures as prototypic of two adjacent channels out of the core. Thermal jet mixing of anticipated flows at different temperatures and velocities were investigated. Velocity profiles are measured throughout the flow region using Ultrasonic Doppler Velocimetry (UDV), and temperatures along the geometric centerline between the jets were recorded using a thermocouple array. CFD simulations, using COMSOL, were used to initially understand the flow, then to design the experimental apparatus and finally to compare simulation results and measurements characterizing the flows. The experimental results and CFD simulations show that the flow field is characterized into three regions with respective transitions, namely, convective mixing, (flow direction) transitional, and post-mixing. Both experiments and CFD simulations support this observation. For the anticipated SFR conditions the flow is momentum dominated and thus thermal mixing is limited due to the short flow length associated from the exit of the core to the bottom of the UIS. This means that there will be thermal striping at any surface where poorly mixed streams impinge; rather unless lateral mixing is ‘actively promoted out of the core, thermal striping will prevail. Furthermore we note that CFD can be considered a ‘separate effects (computational) test’ and is recommended as part of any integral analysis. To this effect, poorly mixed streams then have potential impact on the rest of the SFR design and scaling, especially placement of internal components, such as the IHX that may see poorly mixed streams. Finally, due to lack or infrastructural support for carrying out sodium experiments, only water experiments and CFD studies were realized in, an otherwise sodium approved facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Toward Wireless Smart Grid Communications: An Evaluation of Protocol Latencies in an Open-Source 5G Testbed

Fifth-generation networks promise wide availability of wireless communication with inherent security features. The 5G standards also outline access for different applications requiring low latency, machine-to-machine communication, or mobile broadband. These networks can be advantageous to numerous applications that require widespread and diverse communications. One such application is found in smart grids. Smart grid networks, and Operational Technology (OT) networks in general, utilize a variety of communication protocols for low-latency control, data monitoring, and reporting at every level. Transitioning these network communications from wired Wide Area Networks (WANs) to wireless communication through 5G can provide additional benefits to their security and network configurability. However, introducing these wireless capabilities may also result in a degradation of network latency. In this paper, we propose utilizing 5G for smart grid communications, and we evaluate the latency impacts of encapsulating GOOSE, Modbus, and DNP3 for transmission over a 5G network. The OpenAirInterface open-source library is utilized to deploy an in-lab 5G Core Network and gNB for testing with off-the-shelf User Equipment (UE). This creates an effective 5G test platform for experimenting with different OT protocols such as GOOSE. The results are validated by measuring two different Intelligent Electronic Devices’ contact closure times for each network configuration. These tests are also conducted for varying packet sizes in order to isolate different sources of network latency. Our study outlines the latency impact of communication over 5G for time-critical and non-critical applications regarding their transition toward private 5G-based OT network implementations. The conducted experiments illustrate that in the case of GOOSE packets, simple encapsulation may exceed the protocol’s time-critical nature, and, therefore, additional measures must be taken to ensure a viable transition of GOOSE to 5G services. However, non-critical applications are shown to be viable for migration to 5G.

42 ENGINEERING↗

Analysis of co-spatial UV-optical HST/STIS spectra of planetary nebula NGC 3242

This project sought to consider two important aspects of the planetary nebula NGC 3242 using new long-slit HST/STIS spectra. First, we investigated whether this object is chemically homogeneous by spatially dividing the slit into different regions and calculating the abundances of each region. The major result is that the elements of He, C, O, and Ne are chemically homogeneous within uncertainties across the regions probed, implying that the stellar outflow was well-mixed. Second, we constrained the stellar properties using photoionization models computed by CLOUDY and tested the effects of three different density profiles on these parameters. The three profiles tested were a constant density profile, a Gaussian density profile, and a Gaussian with a power-law density profile. The temperature and luminosity were not affected significantly by the choice of density structure. The values for the stellar temperature and luminosity from our best-fit model are 89.7{sub −4.7}{sup +7.3} kK and log(L/L {sub ⊙}) = 3.36{sub −0.22}{sup +0.28}, respectively. Comparing to evolutionary models on an HR diagram, this corresponds to an initial and final mass of 0.95{sub −0.09}{sup +0.35}M{sub ⊙} and 0.56{sub −0.01}{sup +0.01}M{sub ⊙}, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Crush Testing at Oak Ridge National Laboratory

The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be 'subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage.' Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL's experiences performing crush tests on several different Type B packages. ORNL has crush tested five different drum-type package designs, continuing its 60 year history of RAM package testing. A total of 26 crush tests have been performed in a wide variety of package orientations and crush plate CG alignments. In all cases, the deformation of the outer drum created by the crush test was significantly greater than the deformation damage caused by the 9 m drop test. The crush test is a highly effective means for testing structural soundness of smaller nondense Type B shipping package designs. Further regulatory guidance could alleviate the need to perform the crush test in a wide range of orientations and crush plate CG alignments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗